Search NASA⌕ Search

SEARCH · Search NASA

Results for “OSCILLATION FREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Particle-fluid interaction corrections for flow measurements with a laser Doppler flowmeter

A discussion is given of particle lags in mean flows, acoustic oscillations at single frequencies and in turbulent flows. Some simplified cases lead to exact solutions. For turbulent flows linearization of the equation of motion after assuming the fluid and particle streamlines coincide also leads to a solution. The results show that particle lags are a function of particle size and frequency of oscillation. Additional studies are necessary to evaluate the effect of turbulence when a major portion of the energy is concentrated in small eddies.

Berman, N. S.↗

Evaluation of single crystal LaB6 cathodes for use in a high frequency backward wave oscillator tube

The results of thermionic emission and evaporation studies of single crystal LaB6 cathodes are given. A comparison between the (100), (210) and (310) crystal planes shows the (310) and (210) planes to possess a work function approx 0.2 eV lower than (100). This translates into a significant increase in current density, J, at a specified temperature. Comparison with a state-of-the-art impregnated dispenser cathode shows that LaB6 (310) is a superior cathode in nearly all respects except operating temperature at j 10 A/sq cm. The 1600 K thermionic and room temperature retarding potential work functions for LaB6 (310) are 2.42 and 2.50 respectively.

Swanson, L. W.↗

A new kind of oscillation in the persistent emission of the Rapid Burster

We present a study of a new kind of oscillation found in the persistent emission after some type II bursts from the Rapid Burster observed during 1985 August with EXOSAT. All 95 bursts observed were longer than 30 s. Ten of them were followed by these oscillations. The frequency of the oscillations ranged from 39 to 56 mHz. A period decrease (by 30-50 percent) over a time-scale of about 100 s was observed in seven cases. The fractional rms variation of the oscillations ranged from 5 to 15 percent. In eight cases, about 4-Hz quasi-periodic oscillations with fractional rms values from 6 to 19 percent were observed simultaneously with the new oscillations. There is a high probability that the two forms of oscillation are related to one another.

Lubin, Lori M.↗

Bleed Roughness Mechanism

Suction applied through wall bleed is expected to reduce boundary-layer thickness and lead to a profile that can resist separation. However, experiments with rows of suction holes or slots have shown that the benefits of suction are not realized under certain circumstances. Lee, Sloan and Paynter attributed this to a 'bleed roughness', and modeled the phenomena using a modified inner-length scale with convective lag for the eddy viscosity. Test information was required to determine the roughness values at each Mach number and bleed rate. The present work used numerical calculation, subsonic and supersonic experimentation, and physical modeling were used to explore bleed roughness. It was found that the phenomena can exist in the absence of bleed, that it is a function of geometry and Mach number, and that it does not appear in low subsonic flow. The inner-length scale/convective lag approach was found to be inconsistent with recent physical observation. Alternate steady models for the roughness effect disagreed with mass flux trends and the choked flow limit, and suggested that non-steady mechanisms are present. While new supersonic experiments did exhibit low-frequency plenum oscillations, high-frequency unsteadiness associated with the orifice flow scale appears to be the cause of bleed roughness. In fact, boundary-layer calculations with an oscillatory orifice flow produced the same effect in the time-averaged downstream profile for incompressibile flow. A new empirical turbulence-model was proposed which increased the eddy viscosity throughout the entire boundary-layer by a constant which was calibrated using the zero-bleed profile. Preliminary calculations agreed with the experimental data. The model significantly reduced the test information required to determine roughness values for turbulence modeling, and provided prediction capability for supersonic bleed flows. An abstract of a thesis entitled 'Boundary-Layer Bleed Roughness' is included.

Russell, David A.↗

Synergistic smart fuel for in-pile nuclear reactor measurements

The thermo-acoustic fuel rod sensor developed in this research has demonstrated a novel technique for monitoring the temperature within the core of a nuclear reactor or the temperature of the surrounding heat-transfer fluid. It uses the heat from the nuclear fuel to generate sustained acoustic oscillations whose frequency will be indicative of the temperature. Converting a nuclear fuel rod into this type of thermo-acoustic sensor simply requires the insertion of a porous material (stack). This sensor has demonstrated a synergy with the elevated temperatures that exist within the nuclear reactor using materials that have only minimal susceptibility to high-energy particle fluxes. When the sensor is in operation, the sound waves radiated from the fuel rod resonator will propagate through the surrounding cooling fluid. The frequency of these oscillations is directly correlated with an effective temperature within the fuel rod resonator. This device is self-powered and is operational even in case of total loss of power of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents viewgraphs on the low frequency high amplitude temperature oscillations observed in loop heat pipe operations. The topics include: 1) Proposed Theory; 2) Test Loop and Test Results; and 3) Effects of Various Parameters. The author also presents a short summary on the conditiions that must be met in order to sustain a low frequency high amplitude temperature oscillation.

Ku, Jentung↗

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.↗

MAXIMUM LIKELIHOOD FITTING OF X-RAY POWER DENSITY SPECTRA: APPLICATION TO HIGH-FREQUENCY QUASI-PERIODIC OSCILLATIONS FROM THE NEUTRON STAR X-RAY BINARY 4U1608-522

High-frequency quasi-periodic oscillations (QPOs) from weakly magnetized neutron stars display rapid frequency variability (second timescales) and high coherence with quality factors up to at least 200 at frequencies about 800-850 Hz. Their parameters have been estimated so far from standard min({chi}{sup 2}) fitting techniques, after combining a large number of power density spectra (PDS), to have the powers normally distributed (the so-called Gaussian regime). Before combining PDS, different methods to minimize the effects of the frequency drift to the estimates of the QPO parameters have been proposed, but none of them relied on fitting the individual PDS. Accounting for the statistical properties of PDS, we apply a maximum likelihood method to derive the QPO parameters in the non-Gaussian regime. The method presented is general, easy to implement, and can be applied to fitting individual PDS, several PDS simultaneously, or their average, and is obviously not specific to the analysis of kHz QPO data. It applies to the analysis of any PDS optimized in frequency resolution and for low-frequency variability or PDS containing features whose parameters vary on short timescales, as is the case for kHz QPOs. It is equivalent to the standard {chi}{sup 2} minimization fitting when the number of PDS fitted is large. The accuracy, reliability, and superiority of the method is demonstrated with simulations of synthetic PDS, containing Lorentzian QPOs of known parameters. Accounting for the broadening of the QPO profile, due to the leakage of power inherent to windowed Fourier transforms, the maximum likelihood estimates of the QPO parameters are asymptotically unbiased and have negligible bias when the QPO is reasonably well detected. By contrast, we show that the standard min({chi}{sup 2}) fitting method gives biased parameters with larger uncertainties. The maximum likelihood fitting method is applied to a subset of archival Rossi X-ray Timing Explorer data of the neutron star X-ray binary 4U1608-522, for which we show that the lower kHz QPO parameters can be measured on timescales as short as 8 s. To demonstrate the potential use of the results of the maximum likelihood method, we show that in the observation analyzed the time evolution of the frequency is consistent with a random walk. We then show that the broadening of the QPO due to the frequency drift scales as {radical}T, as expected from a random walk (T is the integration time of the PDS). This enables us to estimate the intrinsic quality factor of the QPO to be {approx}260, whereas previous analysis indicated a maximum value around 200.

79 ASTRONOMY AND ASTROPHYSICS↗

The role of photospheric magnetic fields in the variation of solar oscillation eigenfrequencies

The frequencies of solar oscillations have been found to be higher at the peak of the solar cycle, their variation being consistent with that expected from a change in the solar structure confined to the Sun's outer layers. In this work, a technique is introduced for estimating the effect of the highly inhomogeneous photospheric magnetic field on solar oscillation eigenfrequencies, and its results are compared with the solar data. It is found that the observed steep rise in frequency shift at low frequency and the leveling of or decline at high frequency are well reproduced by the model. The correct order of magnitude for the frequency changes is also reproduced, at least at low frequency. The model implies a particular functional form for the variation of the frequency changes with order and degree, and it is suggested that future advances in observation and theory will therefore allow this model to be confirmed or refuted.

Rosenthal, C. S.↗

Ion beam oscillation due to fluctuation of a hot filament driven magnetized plasma

Ion beam current extracted from a modified Bernas type ion source occasionally exhibits an oscillation at a frequency of several 100 kHz. Increase in the strength of a linear magnetic field induced to the ion source has either decreased or increased the frequency of this oscillation. The frequency showed an increase in proportion to the ion extraction voltage when the frequency decreased with increasing magnetic field. The change of extraction voltage did not affect the frequency when the frequency increased with the increasing magnetic field. Mechanisms causing these oscillations of an ion beam had been investigated.

43 PARTICLE ACCELERATORS↗

Water Flow Testing and Unsteady Pressure Analysis of a Two-Bladed Liquid Oxidizer Pump Inducer

The unsteady fluid dynamic performance of a cavitating two-bladed oxidizer turbopump inducer was characterized through sub-scale water flow testing. While testing a novel inlet duct design that included a cavitation suppression groove, unusual high-frequency pressure oscillations were observed. With potential implications for inducer blade loads, these high-frequency components were analyzed extensively in order to understand their origins and impacts to blade loading. Water flow testing provides a technique to determine pump performance without the costs and hazards associated with handling cryogenic propellants. Water has a similar density and Reynolds number to liquid oxygen. In a 70%-scale water flow test, the inducer-only pump performance was evaluated. Over a range of flow rates, the pump inlet pressure was gradually reduced, causing the flow to cavitate near the pump inducer. A nominal, smooth inducer inlet was tested, followed by an inlet duct with a circumferential groove designed to suppress cavitation. A subsequent 52%-scale water flow test in another facility evaluated the combined inducer-impeller pump performance. With the nominal inlet design, the inducer showed traditional cavitation and surge characteristics. Significant bearing loads were created by large side loads on the inducer during synchronous cavitation. The grooved inlet successfully mitigated these loads by greatly reducing synchronous cavitation, however high-frequency pressure oscillations were observed over a range of frequencies. Analytical signal processing techniques showed these oscillations to be created by a rotating, multi-celled train of pressure pulses, and subsequent CFD analysis suggested that such pulses could be created by the interaction of rotating inducer blades with fluid trapped in a cavitation suppression groove. Despite their relatively low amplitude, these high-frequency pressure oscillations posed a design concern due to their sensitivity to flow conditions and test scale. The amplitude and frequency of oscillations varied considerably over the pump s operating space, making it difficult to predict blade loads.

Schwarz, Jordan B.↗

The 2.2 GHz Surface Acoustic Wave (SAW) oscillator development Ku-band frequency source development

Two 2.2 GHz SAW oscillators using aluminum nitride on sapphire (AlN/Al2O3) delay lines were fabricated. The oscillators were electronically temperature compensated and characterized. One of the oscillators was used as the frequency reference for the Ku band source; the second oscillator is available for continued evaluation. A 15 GHz frequency source was designed and fabricated. The 15 GHz source consists of a Ku band FET oscillator which is phase locked to the frequency multiplied (X7) output of the 2.2 GHz SAW reference source. The Ku band source was built using microstrip circuit designs, which are hybrid compatible. Two wafer runs of 2.2 GHz TED devices were fabricated and evaluated. The devices were mounted on microstrip test substrates and evaluated as 15 GHz divide by 7 circuits. The device evaluation indicated that in their present form the TED is not a practical circuit element.

Source record↗

Semiconductor Reference Oscillator Development for Coherent Detection Optical Remote Sensing Applications

The NASA Earth Science Enterprise Advanced Technology Initiatives Program is supporting a program for the development of semiconductor laser reference oscillators for application to coherent optical remote sensing from Earth orbit. Local oscillators provide the frequency reference required for active spaceborne optical remote sensing concepts that involve heterodyne (coherent) detection. Two recent examples of such schemes are Doppler wind lidar and tropospheric carbon dioxide measurement by laser absorption spectrometry, both of which are being proposed at a wavelength of 2.05 microns. Frequency-agile local oscillator technology is important to such applications because of the need to compensate for large platform-induced Doppler components that would otherwise interfere with data interpretation. Development of frequency-agile local oscillator approaches has heretofore utilized the same laser material as the transmitter laser (Tm,Ho:YLF in the case of the 2.05-micron wavelength mentioned above). However, a semiconductor laser-based frequency-agile local oscillator offers considerable scope for reduced mechanical complexity and improved frequency agility over equivalent crystal laser devices, while their potentially faster tuning capability suggest the potential for greater scanning versatility. The program we report on here is specifically tasked with the development of prototype novel architecture semiconductor lasers with the power, tunability, and spectral characteristics required for coherent Doppler lidar. The baseline approach for this work is the distributed feedback (DFB) laser, in which gratings are etched into the semiconductor waveguide structures along the entire length of the laser cavity. However, typical DFB lasers at the wavelength of interest have linewidths that exhibit unacceptable growth when driven at the high currents and powers that are required for the Doppler lidar application. Suppression of this behavior by means of corrugation pitch-modulation (using a detuned central section to prevent intensity peaking in the center of the cavity) is currently under investigation to achieve the required performance goals.

distributed feedback (DFB) laser↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗