Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Two-way coherent Doppler error due to solar corona

Two-way coherent Doppler errors resulting from phase scintillations induced on the uplink by the solar corona are considered. It is shown that this error can be estimated by taking statistics on the differential Doppler measurements. Typical estimates for the error are given for four Sun-Earth-probe angles and for integration times ranging from 1 second to 1 minute. These results are based on data collected during the 1985 Voyager 2 conjunction.

Kinman, P. W.↗

SU-E-T-399: Determination of the Radiobiological Parameters That Describe the Dose-Response Relations of Xerostomia and Disgeusia From Head and Neck Radiotherapy

Purpose: To estimate the radiobiological parameters that describe the doseresponse relations of xerostomia and disgeusia from head and neck cancer radiotherapy. To identify the organs that are best correlated with the manifestation of those clinical endpoints. Finally, to evaluate the goodnessof- fit by comparing the model predictions against the actual clinical results. Methods: In this study, 349 head and neck cancer patients were included. For each patient the dose volume histograms (DVH) of parotids (separate and combined), mandible, submandibular glands (separate and combined) and salivary glands were calculated. The follow-up of those patients was recorded at different times after the completion of the treatment (7 weeks, 3, 7, 12, 18 and 24 months). Acute and late xerostomia and acute disgeusia were the clinical endpoints examined. A maximum likelihood fitting was performed to calculate the best estimates of the parameters used by the relative seriality model. The statistical methods of the error distribution, the receiver operating characteristic (ROC) curve, the Pearson's test and the Akaike's information criterion were utilized to assess the goodness-of-fit and the agreement between the pattern of the radiobiological predictions with that of the clinical records. Results: The estimated values of the radiobiological parameters of salivary glands are D50 = 25.2 Gy, γ = 0.52, s = 0.001. The statistical analysis confirmed the clinical validity of those parameters (area under the ROC curve = 0.65 and AIC = 38.3). Conclusion: The analysis proved that the treatment outcome pattern of the patient material can be reproduced by the relative seriality model and the estimated radiobiological parameters. Salivary glands were found to have strong volume dependence (low relative seriality). Diminishing the biologically effective uniform dose to salivary glands below 30 Gy may significantly reduce the risk of complications to the patients irradiated for prostate cancer.

60 APPLIED LIFE SCIENCES↗

Experimental consistency in parton distribution fitting

The recently developed 'data set diagonalization' method is applied to measure compatibility of the data sets that are used to determine parton distribution functions. Discrepancies among the experiments are found to be somewhat larger than is predicted by propagating the published experimental errors according to Gaussian statistics. The results support a tolerance criterion of {Delta}{chi}{sup 2{approx_equal}}10 to estimate the 90% confidence range for parton distribution function uncertainties. No basis is found in the data sets for the larger {Delta}{chi}{sup 2} values that are in current use, though it may be necessary to retain those larger values until improved methods can be developed to take account of systematic errors in applying the theory, including the effect of parametrization dependence. The data set diagonalization method also measures how much influence each experiment has on the global fit and identifies experiments that show significant tension with respect to the others. The method is used to explore the contribution from muon scattering experiments, which are found to exhibit the largest discrepancies in the current fit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PULSAR TIMING ERRORS FROM ASYNCHRONOUS MULTI-FREQUENCY SAMPLING OF DISPERSION MEASURE VARIATIONS

Free electrons in the interstellar medium cause frequency-dependent delays in pulse arrival times due to both scattering and dispersion. Multi-frequency measurements are used to estimate and remove dispersion delays. In this paper, we focus on the effect of any non-simultaneity of multi-frequency observations on dispersive delay estimation and removal. Interstellar density variations combined with changes in the line of sight from pulsar and observer motions cause dispersion measure (DM) variations with an approximately power-law power spectrum, augmented in some cases by linear trends. We simulate time series, estimate the magnitude and statistical properties of timing errors that result from non-simultaneous observations, and derive prescriptions for data acquisition that are needed in order to achieve a specified timing precision. For nearby, highly stable pulsars, measurements need to be simultaneous to within about one day in order for the timing error from asynchronous DM correction to be less than about 10 ns. We discuss how timing precision improves when increasing the number of dual-frequency observations used in DM estimation for a given epoch. For a Kolmogorov wavenumber spectrum, we find about a factor of two improvement in precision timing when increasing from two to three observations but diminishing returns thereafter.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic research of Lambda hypernuclei up to medium-heavy mass region with the (e,e'K + ) reaction

In 2009 (August-November), the E05-115 experiment was carried out at JLab to investigate L hypernuclei in the wide mass region up to A = 52 ($7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V) with the (e,e'K + ) reaction. This is the first attempt to investigate a medium heavy L hypernucleus with the (e,e'K + ) reaction. Experimentally, it is difficult to measure heavier L hypernuclei as background rates of particles which originate from electromagnetic processes are roughly in proportion to Z2 (Z: target proton number) in the (e,e'K + ) experiment. To perform the experiment, many experimental techniques have been developed and introduced such as optimization of the electron spectrometer configuration (tilt method), clean kaon identification, particle tracking under high multiplicity environment, precise energy scale calibration and so on. In the present thesis, experimental results of the elementary process of p(e,e'K + )L, L hypernuclei of $7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V are shown. Elementary processes of the electroproduction of L and Σ 0 , p(e,e'K + )L, Σ 0 were used for the absolute energy scale calibration of our spectrometer systems. A careful Monte Carlo simulation shows that the binding energy can be obtained with a systematic error of 0.11 MeV with our energy scale calibration method. A study of the elementary process of L is important to understand L hypernuclei as it is essential for theoretical calculations of L hypernuclei. The differential cross section of the p(e,e'K + )L reaction at the small K + scattering angle (theta-CM/gamma-K approx. 15.5°), the small Q 2 (approx 0.01 [GeV/c] 2 ) and the total energy of W = 1.92 GeV, where no experimental data exists was obtained to be 235 ± 13$+28\atop{-24}$ nb/sr. The ground state (1/2 + ) binding energy of $7\atop{Λ}$He was already measured in JLab E01-011 (2005). In the present work, the binding energy of 1/2 + state was determined to be B Λ = 5.55 ± 0.10 ±0.11 MeV with five times more statistic and smaller systematic errors than those of the previous experiment. The ground state binding energy is important to test the phe- nomenologically introduced CSB (Charge Symmetry Breaking) LN interaction for A = 7, T = 1 hypernuclear systems. In addition, a peak which is interpreted as 3/2 + and 5/2 + states was measured to be B Λ = 3.65 ± 0.20 ±0.11 MeV with sufficient statistic for the first time. Only three events of the ground state of $10\atop{Λ}$ Be had been observed in the emulsion experiments. The present experiment is the first spectroscopic measurement of 10/L-Be, and the detailed structures have been successfully measured for the first time. About three times better energy resolution was achieved in the present experiment (0.78 MeV in FWHM) than that of the mirror L hy- pernucleus, $10\atop{Λ}$B (2.2 MeV in FWHM) which was measured in the (π + ,K + ) experiment at KEK. The result of the ground state binding energy was obtained to be B Λ = 8.55 ± 0.07 ± 0.11 MeV which serves also to discuss about the CSB effect in the LN interaction. $12\atop{Λ}$B has been measured with the world best energy resolution of 0:5 MeV (FWHM) among the reaction spectroscopy of L hypernuclei. The results of $12\atop{Λ}$B are compared with the experimental results in the previous experiments to confirm the consistency. Furthermore, the obtained ground state binding energies of $12\atop{Λ}$B (B Λ = 11.38 ± 0.02 ± 0.11 MeV) and $52\atop{Λ}$V (B Λ = 21.88 ± 0.59 ± 0.11 MeV) indicate that the reported value of 12/L-C which has been used as a reference of binding energy measurements for the (π + ,K + ) experiments would be shallower by ~ 0.5 MeV. A pilot study for investigation in the medium-heavy mass region with the (e,e'K + ) experiment was performed by measuring $52\atop{Λ}$V. The ground state binding energy of $52\atop{Λ}$V has been measured, overcoming high multiplicity environment. The results are discussed with the ex- perimental results of 51/L-V measured at KEK. The present result is the first measurement of L's binding energy of the ground state without the emulsion reference in the medium-heavy mass region, which could be a substantial improvement in the information needed for understanding the single particle potential of L. In the present experiment, L hypernuclear measurement with a small systematic error of ~ 0.1 MeV by the (e,e'K + ) reaction has been established. Moreover, the present work opened a door to the heavier L hypernuclear measurement with the (e,e'K + ) reaction in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inherent Conservatism in Deterministic Quasi-Static Structural Analysis

The cause of the long-suspected excessive conservatism in the prevailing structural deterministic safety factor has been identified as an inherent violation of the error propagation laws when reducing statistical data to deterministic values and then combining them algebraically through successive structural computational processes. These errors are restricted to the applied stress computations, and because mean and variations of the tolerance limit format are added, the errors are positive, serially cumulative, and excessively conservative. Reliability methods circumvent these errors and provide more efficient and uniform safe structures. The document is a tutorial on the deficiencies and nature of the current safety factor and of its improvement and transition to absolute reliability.

Verderaime, V.↗

A Phenomenon-Based Decomposition of Model-Based Estimates of Boreal Winter ENSO Variability

Climate models are now routinely being used to simulate and predict climate variability on time scales ranging from sub-seasonal to seasonal and longer. As such, there are now long histories of such simulations and predictions spanning multiple decades and multiple ensemble members, both of which are crucial for separating climate signal from climate noise. A key focus of such runs has been the El Niño-Southern Oscillation (ENSO), spurred by recent improvements in our ability to predict such events, though questions remain as to how well climate models do beyond simply always predicting the “canonical” atmospheric response to an ENSO event—something simple statistical models already do reasonably well. This is a critical issue that needs addressing, given the importance of event-to-event differences for predicting regional impacts of ENSO teleconnections, and the need to justify the expense of running sophisticated climate models. Unfortunately, current diagnostic tools are not well suited for quantifying the different sources of variability associated with specific phenomena such as ENSO. More generally, while much effort has focused on addressing model bias, less has been done to address errors in second moment statistics—an issue whose importance is gaining increased attention particularly as we build climate prediction systems capable of taking advantage of forecasts of opportunity—a capability that requires reliable estimates of forecast uncertainty. In this report, we outline a phenomenon-based statistical decomposition of climate variance(in essence a detailed variance budget)that is specifically tailored to address the above questions by separating the variability (both the signal and noise) into that tied to the long-term average impact of a particular phenomenon(the composite mean) and the event-to-event(E2E) variability about the composite mean. In addition, we provide related decompositions of the correlations that allow us to quantify how much of the agreement with observations (the skill) comes from the composite mean as opposed to from the E2Evariability. As an example, we present the results of such a decomposition for ENSO based on simulations with the GEOS atmospheric general circulation model (AGCM), with a focus on the monthly mean impacts over North America during boreal winter(December –March). Here we take advantage of existing GEOS AGCM simulations that were produced as companion simulations to MERRA-2for the period 1980-2016. Comparisons are made throughout with MERRA-2.

ENSO↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Closed-Loop Analysis of Soft Decisions for Serial Links

We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

Lansdowne, Chatwin A.↗

Soft Decision Analyzer

We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

Lansdowne, Chatwin↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

Satellite Sampling and Retrieval Errors in Regional Monthly Rain Estimates from TMI AMSR-E, SSM/I, AMSU-B and the TRMM PR

Passive and active microwave rain sensors onboard earth-orbiting satellites estimate monthly rainfall from the instantaneous rain statistics collected during satellite overpasses. It is well known that climate-scale rain estimates from meteorological satellites incur sampling errors resulting from the process of discrete temporal sampling and statistical averaging. Sampling and retrieval errors ultimately become entangled in the estimation of the mean monthly rain rate. The sampling component of the error budget effectively introduces statistical noise into climate-scale rain estimates that obscure the error component associated with the instantaneous rain retrieval. Estimating the accuracy of the retrievals on monthly scales therefore necessitates a decomposition of the total error budget into sampling and retrieval error quantities. This paper presents results from a statistical evaluation of the sampling and retrieval errors for five different space-borne rain sensors on board nine orbiting satellites. Using an error decomposition methodology developed by one of the authors, sampling and retrieval errors were estimated at 0.25 resolution within 150 km of ground-based weather radars located at Kwajalein, Marshall Islands and Melbourne, Florida. Error and bias statistics were calculated according to the land, ocean and coast classifications of the surface terrain mask developed for the Goddard Profiling (GPROF) rain algorithm. Variations in the comparative error statistics are attributed to various factors related to differences in the swath geometry of each rain sensor, the orbital and instrument characteristics of the satellite and the regional climatology. The most significant result from this study found that each of the satellites incurred negative longterm oceanic retrieval biases of 10 to 30%.

Fisher, Brad↗

A STATISTICAL STUDY OF THE SOLAR WIND TURBULENCE AT ION KINETIC SCALES USING THE K-FILTERING TECHNIQUE AND CLUSTER DATA

Plasma turbulence at ion kinetic scales in the solar wind is investigated using the multi-point magnetometer data from the Cluster spacecraft. By applying the k-filtering method, we are able to estimate the full three-dimensional power spectral density P(ω{sub sc}, k) at a certain spacecraft frequency ω{sub sc} in wavevector (k) space. By using the wavevector at the maximum power in P(ω{sub sc}, k) at each sampling frequency ω{sub sc} and the Doppler shifted frequency ω{sub pla} in the solar wind frame, the dispersion plot ω{sub pla} = ω{sub pla}(k) is found. Previous studies have been limited to very few intervals and have been hampered by large errors, which motivates a statistical study of 52 intervals of solar wind. We find that the turbulence is predominantly highly oblique to the magnetic field k >> k {sub ∥}, and propagates slowly in the plasma frame with most points having frequencies smaller than the proton gyrofrequency ω{sub pla} < Ω{sub p}. Weak agreement is found that turbulence at the ion kinetic scales consists of kinetic Alfvén waves and coherent structures advected with plasma bulk velocity plus some minor more compressible components. The results suggest that anti-sunward and sunward propagating magnetic fluctuations are of similar nature in both the fast and slow solar wind at ion kinetic scales. The fast wind has significantly more anti-sunward flux than sunward flux and the slow wind appears to be more balanced.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Statistical Maneuver Analysis for A Low-Thrust NRHO to DRO Transfer

To understand practical implications of implementing transfers that leverage multibody dynamics, a statistical analysis is performed on an Earth-Moon Near Rectilinear Halo Orbit (NRHO) to distant retrograde orbit (DRO) transfer using solar electric propulsion. The statistical analysis includes perturbations due to maneu- ver execution and orbit determination error to understand operational character- istics of the transfer such as statistical ∆V and statistical state targeting errors at the final DRO. We explore the need for low-thrust trajectory correction maneuver (TCM) opportunities as well as the delivery accuracy to the final target. Finally, we explore options for long-term-stable target DROs.

low thrust↗

Multi Optical Transition Radiation System for ATF2

In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.

43 PARTICLE ACCELERATORS↗

Impact of Satellite Viewing-Swath Width on Global and Regional Aerosol Optical Thickness Statistics and Trends

We use the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite aerosol optical thickness (AOT) product to assess the impact of reduced swath width on global and regional AOT statistics and trends. Alongtrack and across-track sampling strategies are employed, in which the full MODIS data set is sub-sampled with various narrow-swath (approximately 400-800 km) and single pixel width (approximately 10 km) configurations. Although view-angle artifacts in the MODIS AOT retrieval confound direct comparisons between averages derived from different sub-samples, careful analysis shows that with many portions of the Earth essentially unobserved, spatial sampling introduces uncertainty in the derived seasonal-regional mean AOT. These AOT spatial sampling artifacts comprise up to 60%of the full-swath AOT value under moderate aerosol loading, and can be as large as 0.1 in some regions under high aerosol loading. Compared to full-swath observations, narrower swath and single pixel width sampling exhibits a reduced ability to detect AOT trends with statistical significance. On the other hand, estimates of the global, annual mean AOT do not vary significantly from the full-swath values as spatial sampling is reduced. Aggregation of the MODIS data at coarse grid scales (10 deg) shows consistency in the aerosol trends across sampling strategies, with increased statistical confidence, but quantitative errors in the derived trends are found even for the full-swath data when compared to high spatial resolution (0.5 deg) aggregations. Using results of a model-derived aerosol reanalysis, we find consistency in our conclusions about a seasonal-regional spatial sampling artifact in AOT Furthermore, the model shows that reduced spatial sampling can amount to uncertainty in computed shortwave top-ofatmosphere aerosol radiative forcing of 2-3 W m(sup−2). These artifacts are lower bounds, as possibly other unconsidered sampling strategies would perform less well. These results suggest that future aerosol satellite missions having significantly less than full-swath viewing are unlikely to sample the true AOT distribution well enough to obtain the statistics needed to reduce uncertainty in aerosol direct forcing of climate.

remote sensing↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗