Study of Triple Ar Gas Puff Z-Pinches on 0.9-MA, 200-ns COBRA

Ar gas puff z-pinch experiments were conducted on the 0.9 MA, 200 ns COBRA generator at Cornell University. In the experiments, a triple-nozzle gas valve was used to produce the zpinch load with concentric outer and inner gas puffs and a central gas jet. We used Planer Laser Induced Fluorescence (PLIF) to measure the initial gas profile of the load, two 4-frame 4-ns gated XUV cameras to image the imploding plasma, and filtered Photo- Conducting Diamond Detectors (PCDs) to measure the x-ray output. We have observed shock heating and/or photoionization of the dense center jet by the imploding plasma. With an outer to inner plenum pressure ratio of 1:3, de-acceleration of the imploding plasma occurred when the outer plasma shell imploded on the inner shell resulting in a stable implosion. By varying the plenum pressure for the center jet, the x-ray emission was optimized. In conclusion, an Ar K-shell x-ray (3-4 keV) yield of 77±17 J was produced at a current level of 0.87±0.2 MA and an implosion time of 200-ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-driven deconvolution for large eddy simulations of Kraichnan turbulence

In this article, we demonstrate the use of artificial neural networks as optimal maps which are utilized for convolution and deconvolution of coarse-grained fields to account for sub-grid scale turbulence effects. Here, we demonstrate that an effective eddy-viscosity is predicted by our purely data-driven large eddy simulation framework without explicit utilization of phenomenological arguments. In addition, our data-driven framework precludes the knowledge of true sub-grid stress information during the training phase due to its focus on estimating an effective filter and its inverse so that grid-resolved variables may be related to direct numerical simulation data statistically. The proposed predictive framework is also combined with a statistical truncation mechanism for ensuring numerical realizability in an explicit formulation. Through this, we seek to unite structural and functional modeling strategies for modeling non-linear partial differential equations using reduced degrees of freedom. Both a priori and a posteriori results are shown for a two-dimensional decaying turbulence case in addition to a detailed description of validation and testing. A hyperparameter sensitivity study also shows that the proposed dual network framework simplifies learning complexity and is viable with exceedingly simple network architectures. Our findings indicate that the proposed framework approximates a robust and stable sub-grid closure which compares favorably to the Smagorinsky and Leith hypotheses for capturing the theoretical k -3 scaling in Kraichnan turbulence.

42 ENGINEERING↗

12W laser amplification at 1427nm on the 4 F 3/2 to 4 I 13/2 spectral line in an Nd 3+ doped fused silica optical fiber

A 9.3dB improvement in optical gain and a 100x improvement in total optical power over prior published experimental results from the 4 F 3/2 to 4 I 13/2 transition in an Nd 3+ doped fused silica optical fiber is demonstrated. This is enabled via an optical fiber waveguide design that creates high spectral attenuation in the 1050-1120nm-wavelength range, a continuous spectral filter for the primary 4 F 3/2 to 4 I 11/2 optical transition. A maximum output power at 1427nm of 1.2W was attained for 43mW coupled seed laser power and 22.2W of coupled pump diode laser power at 880nm a net optical gain of 14.5dB. Reducing the coupled seed laser power to 2.5mW enabled the system to attain 19.3dB of gain for 16.5W of coupled pump power. Four issues limited results; non-optimal seed laser wavelength, amplified spontaneous emission on the 4 F 3/2 to 4 I 9/2 optical transition, low absorption of pump light from the cladding and high spectral attenuation in the 1350-1450nm range. Lastly, future fibers that mitigate these issues should lead to significant improvements in the efficiency of the laser amplifier, though the shorter wavelength region of the transition from 1310nm to >1350nm is still expected to be limited by excited state absorption.

42 ENGINEERING↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing disk registration algorithms for nanobeam electron diffraction strain mapping

Scanning nanobeam electron diffraction strain mapping is a technique by which the positions of diffracted disks sampled at the nanoscale over a crystalline sample can be used to reconstruct a strain map over a large area. However, it is important that the disk positions are measured accurately, as their positions relative to a reference are directly used to calculate strain. Here in this study, we compare several correlation methods using both simulated and experimental data in order to directly probe susceptibility to measurement error due to non-uniform diffracted disk illumination structure. We found that prefiltering the diffraction patterns with a Sobel filter before performing cross correlation or performing a square-root magnitude weighted phase correlation returned the best results when inner disk structure was present. Lastly, we have tested these methods both on simulated datasets, and experimental data from unstrained silicon as well as a twin grain boundary in 304 stainless steel.

36 MATERIALS SCIENCE↗

Dose optimization in pediatric cardiac x-ray imaging

Purpose: The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated. Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat-panel receptor based x-ray imaging system. Tin was used to simulate iodine-based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose, which evaluated the dose efficiency of the x-ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed. Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x-ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom. Conclusions: For pediatric patients, using 0.25-0.9 mm Cu filtration in the x-ray beam while maintaining 50-55 kVp, depending on patient size, provided optimal x-ray image quality to dose ratios. These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x-ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.

60 APPLIED LIFE SCIENCES↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data assimilation in a solar dynamo model using Ensemble Kalman Filters: sensitivity and robustness in reconstruction of meridional flow speed

We implement an Ensemble Kalman Filter procedure using the Data Assimilation Research Testbed for assimilating “synthetic” meridional flow-speed data in a Babcock–Leighton-type flux-transport solar dynamo model. By performing several “observing system simulation experiments,” we reconstruct time variation in meridional flow speed and analyze sensitivity and robustness of reconstruction. Using 192 ensemble members including 10 observations, each with 4% error, we find that flow speed is reconstructed best if observations of near-surface poloidal fields from low latitudes and tachocline toroidal fields from midlatitudes are assimilated. If observations include a mixture of poloidal and toroidal fields from different latitude locations, reconstruction is reasonably good for ⩽40% error in low-latitude data, even if observational error in polar region data becomes 200%, but deteriorates when observational error increases in low- and midlatitude data. Solar polar region observations are known to contain larger errors than those in low latitudes; our forward operator (a flux-transport dynamo model here) can sustain larger errors in polar region data, but is more sensitive to errors in low-latitude data. An optimal reconstruction is obtained if an assimilation interval of 15 days is used; 10- and 20-day assimilation intervals also give reasonably good results. Assimilation intervals <5 days do not produce faithful reconstructions of flow speed, because the system requires a minimum time to develop dynamics to respond to flow variations. Reconstruction also deteriorates if an assimilation interval >45 days is used, because the system’s inherent memory interferes with its short-term dynamics during a substantially long run without updating.

79 ASTRONOMY AND ASTROPHYSICS↗

Injectable platelet rich fibrin facilitates hair follicle regeneration by promoting human dermal papilla cell proliferation, migration, and trichogenic inductivity

Hair follicle regeneration has been successful in mice but failed in human being for years. Dermal papilla cells, a specialized mesenchymal stem cell derived from dermal papilla within hair follicles, is considered the key cells for hair follicle regeneration function as both regeneration initiator and regulator. Injectable platelet rich fibrin (i-PRF), a novel biomaterial rich in a variety of growth factors and three-dimensional scaffolds, has shown promising effects on tissue regeneration. In this study, we aimed to evaluate the application of i-PRF in human hair follicle regeneration by examining the biological effects of i-PRF on human dermal papilla cells (hDPCs). Biomaterial compatibility, cell viability, proliferation, migration, alkaline phosphatase activity and trichogenic inductivity were assessed after exposing hDPCs to different concentrations of i-PRF extracts. In addition, we investigated the ultrastructure of i-PRF with all cell components filtered. The results revealed that i-PRF possessing excellent biocompatibility and could significantly promote hDPCs proliferation, migration, and trichogenic inductivity. Furthermore, the concentration of i-PRF is able to remarkably influence hDPCs behavior in a dose-dependent pattern. Different concentrations exhibited differential effects on hDPCs behavior. In general, lower concentration promotes cell proliferation better than higher concentration, while higher concentration promotes cell function better reversely. Best concentration for hDPCs in vitro expending is 1% concentration. 20% concentration is optimal for hair follicle regeneration. In summary, our findings concluded that i-PRF facilitates hair follicle regeneration by promoting human dermal papilla cell proliferation, migration, and trichogenic inductivity.

60 APPLIED LIFE SCIENCES↗

Multiple aspects maintenance ontology-based intelligent maintenance optimization framework for safety-critical systems

Abstract Maintenance optimization is a process for improving the efficiency of maintenance strategies and activities, considering various aspects of the target system and components, such as the probabilities of system failures and the cost of repair and replacement of a failed component. The improvement of maintenance optimization algorithms generally requires information from various data sources. For example, it may require the system risk information derived from risk analysis tools or the residual lifetime of a component from fault prognosis tools. The requirements of data acquisition (DAQ) and aggregation pose new challenges for maintenance management systems (MMSs) that implement and use these maintenance optimization algorithms. This paper proposes a multiple aspects maintenance ontology-based framework to facilitate DAQ from MMSs, online monitoring systems, fault detection and discrimination tools, risk assessment tools, decision-making tools, and component identification tools, and accelerate the implementation and verification of contemporary maintenance optimization models and algorithms. The proposed framework consists of a multi-aspect maintenance ontology with critical information for maintenance optimization and application interfaces for collecting information from various data sources, such as fault prognosis tools, online monitoring tools, risk assessment tools, and decision-making algorithms. In addition, this paper proposes a heuristic method for integrating concepts and properties from other existing ontologies into the proposed framework when the existing ontology is not fully compatible with the ontology under construction. Finally, the paper verifies the proposed ontology framework using a feedwater system designed for nuclear power plants with valves and filters as the components under maintenance.

Diao, Xiaoxu (ORCID:0000000346726352)↗

Physics-informed machine learning analysis for nanoscale grain mapping by synchrotron Laue microdiffraction

Understanding the grain morphology, orientation distribution and crystal structure of nanocrystals is essential for optimizing the mechanical and physical properties of functional materials. Synchrotron X-ray Laue microdiffraction is a powerful technique for characterizing crystal structures and orientation mapping using focused X-rays. However, when the grain sizes are smaller than the beam size, mixed peaks in the Laue pattern from neighboring grains limit the resolution of grain morphology mapping. We propose a physics-informed machine learning (PIML) approach that combines a convolutional neural network feature extractor with a physics-informed filtering algorithm to overcome the spatial resolution limits of X-rays, achieving nanoscale resolution for grain mapping. Our PIML method successfully resolves the grain size, orientation distribution and morphology of Au nanocrystals through synchrotron microdiffraction scans, showing good agreement with electron backscatter diffraction results. This PIML-assisted synchrotron microdiffraction analysis can be generalized to other diffraction-based probes, enabling the characterization of nanosized structures with micrometre-sized probes.

X-ray crystallography↗

NCAR Contribution to A U.S. National Multi-Model Ensemble (NMME) ISI Prediction System

NCAR brought the latest version of the Community Earth System Model (version 1, CESM1) into the mix of models in the NMME effort. This new version uses our newest atmospheric model CAM5 and produces a coupled climate and ENSO that are generally as good or better than those of the Community Climate System Model version 4 (CCSM4). Compared to CCSM4, the new coupled model has a superior climate response with respect to low clouds in both the subtropical stratus regimes and the Arctic. However, CESM1 has been run to date using a prognostic aerosol model that more than doubles its computational cost. We are currently evaluating a version of the new model using prescribed aerosols and expect it will be ready for integrations in summer 2012. Because of this NCAR has not been able to complete the hindcast integrations using the NCAR loosely-coupled ensemble Kalman filter assimilation method nor has it contributed to the current (Stage I) NMME operational utilization. The expectation is that this model will be included in the NMME in late 2012 or early 2013. The initialization method will utilize the Ensemble Kalman Filter Assimilation methods developed at NCAR using the Data Assimilation Research Testbed (DART) in conjunction with Jeff Anderson’s team in CISL. This methodology has been used in our decadal prediction contributions to CMIP5. During the course of this project, NCAR has setup and performed all the needed hindcast and forecast simulations and provide the requested fields to our collaborators. In addition, NCAR researchers have participated fully in research themes (i) and (ii). Specifically, i) we have begun to evaluate and optimize our system in hindcast mode, focusing on the optimal number of ensemble members, methodologies to recalibrate individual dynamical models, and accessing our forecasts across multiple time scales, i.e., beyond two weeks, and ii) we have begun investigation of the role of different ocean initial conditions in seasonal forecasts. The completion of the calibration hindcasts for Seasonal to Interannual (SI) predictions and the maintenance of the data archive associated with the NCAR portion of this effort has been the responsibility of the Project Scientist I (Alicia Karspeck) that was partially supported on this project.

54 ENVIRONMENTAL SCIENCES↗

The FRIB Decay Station: New Horizons with Rare Isotopes

In May 2022, the Facility for Rare Isotope Beams (FRIB), located on the campus of Michigan State University (MSU), began delivering exotic isotopes to an international community of scientists. New discoveries are now being reported from radioactive decay of neutron-rich nuclei near N = 20 and N = 28.FRIB is expected to produce roughly 80% of the unstable or radioactive isotopes predicted to exist up to uranium (Z = 92). The new user facility is supported by the U.S. Department of Energy, and it is operated by MSU. A high-power superconducting linear accelerator, shaped like a paper-clip, drives the production of these rare isotopes by colliding stable nuclei moving at half the speed of light with a rotating, water-cooled graphite tar-get. These collisions cause the primary stable beam to fragment into a wide variety of unstable nuclei, which can be subsequently filtered through a multistage magnetic separator, the Advanced Rare Isotope Separator, and transported to one of several experimental stations. The FRIB Decay Station initiator (FDSi) (see Figure 1) was developed to enable comprehensive radio-active decay studies of the exotic nuclei produced by FRIB and it was used in the first two experiments in 2022. Further, the FDSi is a highly reconfigurable multidetector system with two focal planes (FP1 for discrete spectroscopy and FP2 for total absorption spectroscopy) that can be optimized for the specific science goals of each experiment. It is designed, built, and operated by a community of users with the sup-port of U.S. funding agencies, including the Department of Energy and National Science Foundation.

07 ISOTOPE AND RADIATION SOURCES↗

Structure Discovery in Large Semantic Graphs Using Extant Ontological Scaling and Descriptive Statistics

As semantic datasets grow to be very large and divergent, there is a need to identify and exploit their inherent semantic structure for discovery and optimization. Towards that end, we present here a novel methodology to identify the semantic structures inherent in an arbitrary semantic graph dataset. We first present the concept of an extant ontology as a statistical description of the semantic relations present amongst the typed entities modeled in the graph. This serves as a model of the underlying semantic structure to aid in discovery and visualization. We then describe a method of ontological scaling in which the ontology is employed as a hierarchical scaling filter to infer different resolution levels at which the graph structures are to be viewed or analyzed. We illustrate these methods on three large and publicly available semantic datasets containing more than one billion edges each. Keywords-Semantic Web; Visualization; Ontology; Multi-resolution Data Mining;

Multiresolution Data Mining↗

BLOC Site - ASSIST Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Radiances are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Systems and methods for determining optimal parameters for dynamic quantum clustering analyses

In the present work, quantum clustering is extended to provide a dynamical approach for data clustering using a time-dependent Schrodinger equation. To expedite computations, we can approximate the time-dependent Hamiltonian formalism by a truncated calculation within a set of Gaussian wave-functions (coherent states) centered around the original points. This allows for analytic evaluation of the time evolution of all such states, opening up the possibility of exploration of relationships among data points through observation of varying dynamical-distances among points and convergence of points into clusters. This formalism may be further supplemented by preprocessing, such as dimensional reduction through singular value decomposition and/or feature filtering. Additionally, the parameters of the analysis can be modified in order to improve the efficiency of the dynamic quantum clustering processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit

Purpose: The purpose of this work is to characterize the x-ray volume imager (XVI), the cone-beam computed tomography (CBCT) unit mounted on the Elekta Synergy linac, with F1 bowtie filter and to calculate the three-dimensional dose delivered to patients using volumetric acquisition. Methods: The XVI is modeled in detail using a new Monte Carlo (MC) code, BEAMPP, under development at the National Research Council Canada. In this investigation, a new component module is developed to accurately model the unit's bowtie filter used in conjunction with the available beam collimators at the clinical energy of 120 kV. The modeling is compared against percentage depth dose (PDD) and profile measurements. Kilovoltage radiation beams' phase space files are also analyzed. The authors also describe a method for the absolute dose calibration of the MC model of the CBCT unit when used in a clinical volumetric acquisition mode. Finally, they calculate three-dimensional patient dose from CBCT image acquisition in three clinical cases of interest: Pelvis, lung, and head and neck. Results: The agreement between measurement and MC is shown to be very good: Within {+-}2% for the PDD and within {+-}3.5% inside the radiation field for all the collimators with the F1 bowtie filter. A full account of the absolute calibration method is given and dose calculation is validated against ion chamber measurements in different locations of a plastic phantom. Calculations and experiments agree within {+-}2% or better in both at the center and the periphery of the phantom, with worst agreement of 4.5% at the surface of the phantom and for one specific combination of collimator and filter. Patient dose from CBCT scan reveals that dose to tissue is between 2 and 2.5 cGy for a pelvis or a lung full acquisition. For H and N dose to tissue is 5 cGy, with the unit presets used in this work. Dose to bony structures can be two to three times higher than dose to tissue. Conclusions: The XVI CBCT unit has been fully modeled including the F1 bowtie filter. Absolute dose distribution from the unit has been successfully validated. Full MC patient dose calculation has shown that the three-dimensional dose distribution from CBCT is complex. Patient dose from CBCT exposure cannot be completely accounted for by using a numerical factor as an estimate of the dose at the center of the body. Furthermore, additional dose to bone should be taken into account when adopting any IGRT strategy and weighed vs the unquestionable benefits of the technique in order to optimize treatment. Full three-dimensional dose calculation is recommended if patient dose from CBCT is to be integrated in any adaptive planning strategy.