Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Improve Replication of In-service Mechanical Environments

Structural dynamic testing is a common method for determining if the design of a component of a system will mechanically fail when deployed into its field environment. To satisfy the test's goal, the mechanical stresses must be replicated. Structural dynamic testing is commonly executed on a shaker table or a shock apparatus such as a drop table or a resonant plate. These apparatus impart a force or load on the component through a test fixture that connects the unit under test to the apparatus. Because the test fixture is directly connected to the unit under test, the fixture modifies the structural dynamics of the system, thus varying the locations and relative levels of stress on the unit under test. This may lead to a false positive or negative indication if the unit under test will fail in its field environment depending on the environment and the test fixture. This body of research utilizes topology optimization using the Plato software to design a test fixture that attaches to the unit under test that matches the dynamic impedance of the next level of assembly. The optimization's objective function is the difference between the field configuration and the laboratory configuration's frequency response functions. It was found that this objective function had many local minima and posed difficulties in converging to an acceptable solution. A case study is presented that uses this objective function and although the results are not perfect, they are quantifiably better than the current method of using a sufficiently stiff fixture.

42 ENGINEERING↗

DOE Hanford Network Upgrades and Disaster Recovery Exercise Support the Cleanup Mission Now and into the Future

In 2013, the U.S. Department of Energy's (DOE) Hanford Site, located in Washington State, funded an update to the critical network infrastructure supporting the Hanford Federal Cloud (HFC). The project, called ET-50, was the final step in a plan that was initiated five years ago called "Hanford's IT Vision, 2015 and Beyond." The ET-50 project upgraded Hanford's core data center switches and routers along with a majority of the distribution layer switches. The upgrades allowed HFC the network intelligence to provide Hanford with a more reliable and resilient network architecture. The culmination of the five year plan improved network intelligence and high performance computing as well as helped to provide 10 Gbps capable links between core backbone devices (10 times the previous bandwidth). These improvements allow Hanford the ability to further support bandwidth intense applications, such as video teleconferencing. The ET-50 switch upgrade, along with other upgrades implemented from the five year plan, have prepared Hanford's network for the next evolution of technology in voice, video, and data. Hand-in-hand with ET-50's major data center outage, Mission Support Alliance's (MSA) Information Management (IM) organization executed a disaster recovery (DR) exercise to perform a true integration test and capability study. The DR scope was planned within the constraints of ET-50's 14 hour datacenter outage window. This DR exercise tested Hanford's Continuity of Operations (COOP) capability and failover plans for safety and business critical Hanford Federal Cloud applications. The planned suite of services to be tested was identified prior to the outage and plans were prepared to test the services ability to failover from the primary Hanford data center to the backup data center. The services tested were: Core Network (backbone, firewall, load balancers); Voicemail; Voice over IP (VoIP); Emergency Notification; Virtual desktops; and, Select set of production applications and data. The primary objective of the exercise was to test COOP around the emergency operations at Hanford to provide information on capabilities and dependencies of the current system to insure improved focus of emergency, safety and security capacity in a disaster situation. The integration of the DR test into the ET-50 project allowed the testing of COOP at Hanford and allowed the lessons learned to be defined. These lessons learned have helped improve the understanding of Hanford's COOP capabilities and will be critical for future planning. With the completion of the Hanford Federal Cloud network upgrades and the disaster recovery exercise, the MSA has a clearer path forward for future technology implementations as well as network improvements to help shape the usability and reliability of the Hanford network in support of the cleanup mission.

97 MATHEMATICS AND COMPUTING↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible under Hydrodynamic Loading: Preprint

The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal of this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.

17 WIND ENERGY↗

Energy-saving opportunities of direct-DC loads in buildings

Despite the recent interest in direct current (DC) power distribution in buildings, the market for DC-ready loads remains small. The existing DC loads in various products or research test beds are not always designed to efficiently leverage the benefits of DC. This work addresses a pressing need for a study into the development of efficient DC loads. In particular, it focuses on documenting and demonstrating how to best leverage a DC input to eliminate or improve conversion stages in a load's power converter. This work identifies how typical building loads can benefit from DC input, including bath fans, refrigerators, wall adapters, task lights, and zone lighting. It then details the development of several prototypes that demonstrate efficiency savings with DC. The most efficient direct-DC loads are explicitly designed for DC from the ground up, rather than from an AC modification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RH Packaging Program Guidance

The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package (also known as the "RH-TRU 72-B cask") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using a Three-Column System with Crystalline Silicotitanate and Hanford Tank Waste 241-AP-107

Washington River Protection Solutions (WRPS) is working to support early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which in effect filters tank waste supernate and processes it through a cesium ion exchange medium to remove 137Cs. The 137Cs-depleted product is sent to the WTP for vitrification. Rovira et al. (2018) reported the successful Cs removal from Hanford tank 241-AP-107 waste (hereafter called AP-107) using crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B, Batch 2081000057) in a lead-lag column system. Since that testing, WRPS has changed the column design to a three-column system. WRPS requested a repeated study with AP-107 tank waste using a different batch of IONSIVTM R9140-B, Lot 2002009604, in a three-column format. A small-scale test platform was constructed to demonstrate solids filtration, Cs removal, and LAW vitrification and installed at Pacific Northwest National Laboratory. This report describes the small-scale ion exchange testing system component of the test platform and the processing of approximately 8.55 L of filtered AP-107 supernate using CST, Lot 8056262-999, that passed through a 25-mesh filter. This report also describes the Cs ion exchange batch contact testing to determine the Cs distribution coefficient and the maximum Cs loading capacity in the AP-107 tank waste matrix. Batch contact testing helps to evaluate CST performance on tank waste supernate and is often used prior to processing tank waste through ion exchange columns to assess some performance metrics (e.g., 50% Cs breakthrough). Batch contact tests were performed with the filtered AP-107 tank waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass). The distribution coefficient (K d ) at the equilibrium condition of 9.2 µg Cs/mL (AP-107 feed condition) was determined to be 806 mL AP 107/g CST. With a CST bed density of 1.01 g/mL (<25 mesh CST), this K d corresponded to a predicted 50% Cs breakthrough of 814 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 8.3 mg Cs/g dry CST. The three-column format testing was prototypic to the intended TSCR operations, albeit on a small scale with 10-mL CST beds. Flowrate was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) flow rate. The feed was processed downflow through the lead column, then through the middle column, and then through the polish column. Loading continued at an average of 1.88 BV/h (1.83 to 2.04 BV/h range) until the entire available AP-107 feed was processed. The Cs-decontaminated product will be provided for vitrification testing. The lead column only reached 45% Cs breakthrough after processing 855 BVs of feed. The 50% Cs breakthrough was extrapolated to occur at ~900 BVs. This extrapolated 50% Cs breakthrough value differed from the batch contact estimate (814 BVs) by 13%. The waste acceptance criteria (WAC) or contract limit for the WTP LAW vitrification facility is 3.18E-5 Ci 137 Cs per mole Na. For the AP-107 tank waste, only 0.127% of the influent 137 Cs concentration may be delivered to the WTP; this required a Cs decontamination factor of 787. The Cs effluent from the middle column reached the WAC after processing 590 BVs. Cs breakthrough from the polish column began at 590 BVs, reaching 6.3E-3 µCi/mL or 4.3E-3% Cs breakthrough after processing 844 BVs of feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drop Analysis of a Department of Energy Standard Canister Containing Fort Saint Vrain SNF

DOE manages over 300 types of SNF, many of which are located at the INL site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage (RRDS) is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in on-site storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale RRDS program at the INL site. One critical aspect of RRDS is the ability to certify the DOE Standard Canister and its associated transportation package in accordance with 10 CFR 71 for offsite transportation. Depending on the SNF type and transportation strategy, DOE Standard Canisters may be required to maintain structural integrity under hypothetical accident scenarios (e.g., drop events). The DOE Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs; however, no analysis has yet been completed in support of the recently initiated Road-Ready Demonstration. This paper presents preliminary results from a finite element analysis of the Ø45.7 cm × 4.6 m (Ø18 in. × 15 ft) DOE Standard Canister under the 9 m drop at 80 degrees off-vertical drop scenario considered in previous INL tests and analyses. It considers the Fort St. Vrain spent nuclear fuel loading configuration proposed for the Road-Ready Demonstration, uses updated material properties, and applies the strain-based acceptance criteria established in ASME Boiler and Pressure Vessel Code’s Section III, Division 3 rules for storage and transportation spent nuclear fuel containments. This updated analysis is compared to previous DOE Standard Canister drop analyses. Preliminary results from the updated analysis show that certain regions of the containment exceed the allowable limits during the accidental drop event. However, these regions are limited to components performing a non-structural function. While further work on this analysis will be pursued, this analysis serves as the foundation for formal calculations used to support applicable certification efforts of the RRDS system at INL.

42 ENGINEERING↗

Toward engineering lattice structures with the material point method (MPM)

This study examines the potential of two variants of the material point method—the generalized interpolation material point (GIMP) and dual domain material point (DDMP) methods—in developing a robust computational framework for engineering lattice structures under different loading conditions. The study begins with assessing the ability of the two methods in predicting elastic buckling phenomena using column geometries with and without initial geometric imperfections. The results indicate that both methods effectively capture buckling phenomena when initial geometric imperfections are introduced. After this verification step, we create several models of tetrahedral lattice structures with varying strut diameter and orientation and subject them to quasi-static loading. We then validate the numerical results using laboratory test results. The results show that, while both methods accurately predict load–displacement curves in the pre-buckling regime, their predictive capabilities diminish in the post-buckling regime. Through visual comparison between the numerical and experimental deformed shapes, it appears that the discrepancies between model and experimental results are attributed to initial geometric imperfections in the lattices that occurred during 3D printing. We then establish a second set of lattice models where different types of initial geometric imperfections are considered. The results from these models show that imperfections have a negligible influence in the pre-buckling regime but affect the behavior considerably in the post-buckling regime. As a final step in this work, we subject the lattice models to impact loading and employ hypothetical soft and stiff materials. These results show that the lattice stiffness, which depends on material stiffness, strut diameter, and orientation, significantly influences the ability of a lattice structure to resist impact. In particular, we find that a stiffer lattice (i.e., one made with a stiff material and thicker struts) is capable of absorbing more energy than a softer one during impact. Although material nonlinearities, inelasticity, and detailed contact formulations are not considered in this study, the findings obtained herein lay the groundwork for engineering lattice structures under extreme loading conditions through a simulation-driven framework based on particle-based methods.

97 MATHEMATICS AND COMPUTING↗

Simulation-based Testing of Control Software

It is impossible to adequately test complex software by examining its operation in a physical prototype of the system monitored. Adequate test coverage can require millions of test cases, and the cost of equipment prototypes combined with the real-time constraints of testing with them makes it infeasible to sample more than a small number of these tests. Model based testing seeks to avoid this problem by allowing for large numbers of relatively inexpensive virtual prototypes that operate in simulation time at a speed limited only by the available computing resources. In this report, we describe how a computer system emulator can be used as part of a model based testing environment; specifically, we show that a complete software stack including operating system and application software - can be deployed within a simulated environment, and that these simulations can proceed as fast as possible. To illustrate this approach to model based testing, we describe how it is being used to test several building control systems that act to coordinate air conditioning loads for the purpose of reducing peak demand. These tests involve the use of ADEVS (A Discrete Event System Simulator) and QEMU (Quick Emulator) to host the operational software within the simulation, and a building model developed with the MODELICA programming language using Buildings Library and packaged as an FMU (Functional Mock-up Unit) that serves as the virtual test environment.

97 MATHEMATICS AND COMPUTING↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

High Performance PEFC Electrode Structures

Raytheon Technologies Research Center (RTRC) in collaboration with Ion Power Inc. and the University of Arkansas at Little Rock and the FC-PAD consortium executed a project that: (1) developed comprehensive models of oxygen and proton transport in cathode catalyst layers that provided new insights about losses associated with reducing platinum loading to 0.1 mg/cm 2 , (2) designed, fabricated, characterized, and tested cells featuring carbon-supported catalyst layers with low platinum loadings that met efficiency and power density targets set forth by the Hydrogen and Fuel Cells Technology Office, and (3) designed, fabricated, characterized, and tested novel catalyst structures. The modeling efforts produced eight scientific publications that shared new descriptions of oxygen and proton transport in catalyst layers with the broader technical community. The key physical insights from the models are expressed in straightforward algebraic expressions, facilitating easy adoption by other researchers. The models developed during the project explain why resistance to oxygen transport is inversely proportional to interfacial area of platinum – an observation that eluded quantitative explanation for a decade. The models quantitatively predict polarization when measured morphological parameters and transport properties are input. Membrane-electrode assemblies made during the project met stated goals for current at high voltage and power density at rated voltage for transportation fuel cells at the end of budget period 2. High performance was achieved by developing a diffusion layer with low resistance to oxygen transport and a PtCo/C cathode catalyst layer capable of supporting rapid proton and oxygen transport. The project was subsequently directed to curtail experimental work and focus on modeling during budget period 3. Ion Power Inc. developed new expertise in fabricating catalyst layers containing platinum-cobalt catalysts, and processing very thin membranes. The University of Arkansas at Little Rock developed novel nanocolumnar self-supported thin film electrocatalysts that can be grown on carbon supports using a simple high pressure sputter deposition method. The nanocolumnar microstructure provides adequate surface-to-volume ratio for efficient platinum utilization, and the conformal platinum shell with larger crystal grain sizes covering the carbon support surface may eliminate durability issues associated with catalyst dissolution, agglomeration, and carbon corrosion.

08 HYDROGEN↗

Effects of fabric architectures on mechanical and damage behaviors in carbon/epoxy woven composites under multiaxial stress states

The mechanical properties and damage evolutions of carbon/epoxy woven fabric composites with three different fabric architectures, including one plain weave and two twill weave patterns, are experimentally investigated under multiaxial stress states. In particular, the effects of weave patterns are investigated by monotonic and cyclic off-axis tension tests. Both elastic modulus and strength degrade remarkably with increasing off-axis loading angle, while Poisson's ratio is much higher than that measured from on-axis tests and increases with loading strain gradually. Different fabric architectures show limited effects on the modulus and strength under multiaxial stress states, and they are well predicted by transformation equation and Tsai-Wu failure criteria, respectively. However, significantly different failure behaviors are observed in three fabric composites, and microstructure observation shows that fabric architecture affects the stress concentration and the damage development. Smaller crimp ratio and compacted structure postpone the damage development but result in more abrupt failure under multiaxial stress states.

36 MATERIALS SCIENCE↗

Differentially Private K -Means Clustering Applied to Meter Data Analysis and Synthesis

The proliferation of smart meters has resulted in a large amount of data being generated. It is increasingly apparent that methods are required for allowing a variety of stakeholders to leverage the data in a manner that preserves the privacy of the consumers. The sector is scrambling to define policies, such as the so called ‘15/15 rule’, to respond to the need. However, the current policies fail to adequately guarantee privacy. Here, in this paper, we address the problem of allowing third parties to apply K-means clustering, obtaining customer labels and centroids for a set of load time series by applying the framework of differential privacy. We leverage the method to design an algorithm that generates differentially private synthetic load data consistent with the labeled data. We test our algorithm’s utility by answering summary statistics such as average daily load profiles for a 2-dimensional synthetic dataset and a real-world power load dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration of CDM-Based Creep Constitutive Model Using Accelerated Creep Test (ACT) Data

In conventional creep testing (CCT) a specimen is subject to constant load and temperature for a long-duration until creep rupture occurs. Conventional testing can be costly when considering the number of experiments needed to characterize the creep response of a material over a range of stress and temperature. To predict long-term creep-rupture properties, the time-temperature-stress superposition principle (TTSSP) approach has been employed where stress and/or temperature is applied at an elevated level; the result of which are extrapolated down to low stress and/or temperature conditions. These methods have been successful in predicting minimum-creep-strain-rate (MCSR) and stress-rupture (SR) but suffer from an inability to predict the creep deformation curve or account for changes in deformation mechanisms or aging that occurs at long-duration. An accelerated technique, termed the Stepped isostress method (SSM) allows the accelerated testing of materials to determine their creep deformation response. Unlike TTSSP tests, the SSM test employs a single specimen where the stress is periodically step increased until rupture. The SSM creep deformation curve is processed (time and strain shifted) to produce an accelerated creep deformation curve that represent the creep deformation curve at the initial stress level in SSM. A processing procedure for metals has yet to be developed. The research objective of this study is to develop a processing procedure for SSM test data using a creep-damage constitutive model. Triplicate SSM tests were conducted on Ni-based superalloy Inconel 718 at 650°C with stress being periodically increased until rupture. Triplicate CCT tests were conducted at the initial stress level of the SSM tests. The Sine-hyperbolic (Sinh) creep-damage model was employed in this study. The Sinh creep-damage constitutive model is based on coupled creep strain rate and damage evolution equations; where both rates are dependent on the current state of damage. Calibration is two-step: analytical and numerical optimization. Each stepped creep deformation curve is tackled quasi-analytically to determine MCSR and SR related material constants and accumulated damage. The damage accumulated at the end of each step was then passed onto subsequent steps to calibrate the MCSR, rupture prediction, and damage evolution. Numerical optimization was applied to optimize model constants involved in the creep strain constitutive equations in order to generate best-fitted Sinh creep deformation curves. The Sinh model predictions were compared to the SSM and CCT data. The Sinh model satisfactorily predicts the SSM data and thus the calibrated material constants provides a good estimate of rupture found in the CCT data. Calibration using SSM data reduces the number of tests needed to calibrate a model; significantly reducing costs. A single SSM test replaces numerous creep tests at different stresses.

36 MATERIALS SCIENCE↗

Effect of recycled fibers and shredded intermediates variation on the mechanical properties and energy absorption of fiber‐reinforced composite panels

Abstract The global composite industry generates large quantities of waste which mostly ends up in landfills due to a lack of established end‐use applications for multiple waste streams. The scrap from end‐of‐life (EoL) includes manufacturing waste such as dry chopped fiber tows, loose fibers, shredded fibers from fabric textile operations, cured/semi‐cured prepregs, and fully cured composite structure waste from aircraft, automobiles, wind blades, boats, and pressure vessels. In this work, different composite waste streams were reduced to shredded intermediates, followed by simple blending, and subjected to wet compression molding to produce composite panels. The panels/plaques were tested for mechanical properties (flexure and impact), fiber‐matrix wet‐out, and property bounds. It was found that wet‐compression molding was a viable and scale‐able approach to produce recycled panels from EoL composites shredded scrap. Furthermore, full‐scale size panels for use in truck bodies and intermodal shipping container flooring were manufactured and their impact resistance was tested using a drop weight impact test. They were tested both for high‐ and low‐velocity load. In the case of high‐velocity load, the average impact load was 14,673 N; the average absorbed energy was 101.6 J; the average elastic energy was 11.7 J and the impact resistance was 1065 J/m. In the case of the low‐velocity drop weight impact test, it was found that the average impact load was 7877.358 N; the average absorbed energy was 9.718 J; the average elastic energy was 9.14 J, and the impact resistance was 184.1 J/m. The shredded composite was shown to be a candidate material for the manufacture of truck bodies and intermodal containers’ flooring panels. Highlights By using shredded intermediates from different composite waste streams, it is possible to manufacture composite panels. Wet–compression process is an appropriate technique for manufacturing recycled fiber composite panels. Regardless of the source of scrap, the mechanical properties of the produced composite panels were improved. The recycling process technology can be transformed to commercial scale to produce full‐size transportation flooring panels. A product pathway is established in consideration of lower cost and improved recyclability.

Vaidya, Uday↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

Brazil disc Testing of LX-17-1

When considering alternate test methods for assessing the tensile performance of insensitive plastic bonded explosive (PBX) materials, Brazil disc tensile testing is attractive from several standpoints. First, compared to the traditional dog-bone shaped specimen normally used in the direct tensile test, the Brazil test specimen is considerably easier to produce. Second, the Brazil specimen is compact, with a low aspect ratio that allows it to be machined from a wide variety of pressed geometries. Assuming test results are consistent and interpretable, the method could open up possibilities for rapid assessment of ultimate tensile strengths, and might be especially attractive when a large number of samples are to be tested. The trade-off for specimen simplicity is, however, that interpretation of the results from Brazil tests is inherently far less intuitive, and more difficult, than is the case with traditional tensile testing, since the method involves complex stress loading. As a result, the derivation of what one hopes are equivalent tensile failure stresses from Brazil testing necessitates some fairly involved calculations, requiring parameters that are not always readily obtained. In addition to some significant uncertainties, the specimen geometry does not lend itself easily to the accommodation of traditional strain measurement devices such as extensometers. As a consequence, optical techniques such as digital image correlation (DIC) are preferred when stress-strain curves are needed. In this test series we performed a sequence of experiments using Brazil discs made from LX-17-1. Tests were performed on samples at two different scaled sizes: discs that were 0.5 inches in diameter and 0.25 inch thick, and discs that were 1 inch in diameter and a 0.5 inch thick. Each of the specimen sets was tested using matching, equivalently scaled test fixtures, each with anvils whose radii were 0.25% greater than their respective specimen radii. All specimens tested were machined from billet pressed material made from Holston #851009 (LLNL tag #C-329) LX-17-1 molding powder. Tests were performed at two temperatures, +23 °C and +50 °C, with three each test redundancies at each condition. Based on data from this set of experiments we hoped to provide preliminary answers to a number of questions, including: 1) Roughly, what is the level of scatter in the data? 2) Are results scale independent, at least within the limited range of specimen sizes tested? 3) Using a consistent set of parameters, can we use the equations given by Sato and Awaji1 to calculate peak tensile stresses that are nearly equivalent to those measured using traditional dog-bone tensile testing methods.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗