Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Boron doped simulated graphene field effect transistor model

Graphene based electronic devices due to its unique properties has transformed electronics. A Graphene Field Effect Transistor (GNRFET) model is simulated in Virtual Nano Lab (VNL) and the calculations are based on density functional theory (DFT). Simulations were performed on this pristine GNRFET model and the transmission spectrum was observed. The graph obtained showed a uniform energy gap of +1 to −1eV and the highest transmission peak at −1.75 eV. To this pristine model of GNRFET, doping was introduced and its effect was seen on the Fermi level obtained in the transmission spectrum. Boron as a dopant was used which showed variations in both the transmission peaks and the energy gap. In this model, first the single boron was substituted in place of carbon and Fermi level showed an energy gap of 1.5 to −0.5eV with the highest transmission peak at −1.3 eV. In another variation in the model, two carbon atoms were replaced by two boron atoms and Fermi level shifted from 2 to 0.25eV. In this observation, the highest transmission peak was observed at −1(approx.). The use of nanoelectronic devices have opened many areas of applications as GFET is an excellent building block for electronic circuits, and is being used in applications such as high-performance frequency doublers and mixers, digital modulators, phase detectors, optoelectronics and spintronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient charge to spin conversion in iridium oxide thin films

Many 5d transition metal oxides have a unique electronic structure, where the density of states near the Fermi level is dominated by only 5d electrons with strong spin–orbit coupling. IrO 2 , a Dirac nodal line semi-metal, is the simplest of these oxides. The presence of 5d electrons and gap opening of Dirac nodal lines via strong spin–orbit coupling allows for the hybridization of the 5d electrons of the oxide with the itinerant d electrons of a ferromagnet, while simultaneously increasing the intrinsic spin Hall effect. We report large charge-to-spin conversion in thin films of this material using spin-torque ferromagnetic resonance experiments. Finally, by independently performing line shape analysis and linewidth modulation experiments, we conclusively determine the spin Hall angle of optimized IrO 2 films to be ∼8 times larger than that of Pt.

Ferromagnetic materials↗

Demonstration of GaInP2/Si Voltage Matched Tandem Solar Cells

Mechanically-stacked tandem solar cells combining existing photovoltaic technologies present a straightforward path toward higher conversion efficiencies. Voltage-matched configurations have been proposed as a simplified approach for fabricating two terminal modules, but they are subject to performance losses compared to four terminal configurations if voltage-matching conditions are not met. Here, we demonstrate a two terminal voltage-matched GaInP 2 /Si tandem with 23% efficiency. Through a combination of experimental measurement and simulation, we explore the impact of voltage and fill factor mismatches between the top and bottom sub-cell strings. Our results show that efficiency losses are minimized when voltage-mismatches are accommodated by designing the bottom strings to have a higher voltage. Fill factor mismatches due to differences in series resistance also lead to changes in the optimal ratio of the number of cells in the top and bottom sub-cell strings.

14 SOLAR ENERGY↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-01: Multi-Centre Collaborative Quality Assurance Program for IMRT Planning and Delivery: Year 3 Results

Purpose: A multi-centre quality assurance program was developed to enable quality improvement by coupling measurement of intensity modulated radiotherapy (IMRT) planning and delivery performance for site-specific planning exercises with diagnostic testing. The third year of the program specifically assessed the quality of spine stereotactic body radiotherapy (SBRT) planning and delivery amongst the participating centres. Methods: A spine SBRT planning exercise (24 Gy in 2 fractions) was created and completed by participants prior to an on-site visit. The delivery portion of the on-site visit included spine SBRT plan delivery and diagnostic testing, which included portal image acquisition for quantification of phantom positioning error and multi-leaf collimator (MLC) calibration accuracy. The measured dose was compared to that calculated in the treatment planning system (TPS) using 3%/2mm composite analysis and 3%/3mm gamma analysis. Results: Fourteen institutions participated, creating 17 spine SBRT plans (15 VMAT and 2 IMRT). Three different TPS, two beam energies (6 MV and 6 MV FFF), and four MLC designs from two linac vendors were tested. Large variation in total monitor units (MU) per plan (2494–6462 MU) and dose-volume parameters was observed. The maximum point dose in the plans ranged from 116–149% and was dependent upon the TPS used. Pass rates for measured to planned dose comparison ranged from 89.4–100% and 97.3–100% for 3%/2mm and 3%/3mm criteria respectively. The largest measured MLC error did Result in one of the poorer pass rates. No direct correlation between phantom positioning error and pass rates overall. Conclusion: Significant differences were observed in the planning exercise for some plan and dose-volume parameters based on the TPS used. Standard evaluation criteria showed good agreement between planned and measured dose for all participants, however on an individual plan basis, diagnostic tests were able to identify contributing factors for poorer results, when using more stringent evaluation criteria. Funding from Cancer Care Ontario is acknowledged.

60 APPLIED LIFE SCIENCES↗

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

Modeling and designing multilayer 2D perovskite / silicon bifacial tandem photovoltaics for high efficiencies and long-term stability

A key challenge in photovoltaics today is to develop cell technologies with both higher efficiencies and lower fabrication costs than incumbent crystalline silicon (c-Si) singlejunction cells. While tandem cells have higher efficiencies than c-Si alone, it is generally challenging to find a low-cost, high-performance material to pair with c-Si. However, the recent emergence of 22% efficient perovskite photovoltaics has created a tremendous opportunity for high-performance, low-cost perovskite / crystalline silicon tandem photovoltaic cells. Nonetheless, two key challenges remain. First, integrating perovskites into tandem structures has not yet been demonstrated to yield performance exceeding commercially available crystalline silicon modules. Second, the stability of perovskites is inconsistent with the needs of most end-users, who install photovoltaic modules to produce power for 25 years or more. Making these cells viable thus requires innovation in materials processing, device design, fabrication, and yield. We will address these two gaps in the photovoltaic literature by investigating new types of 2D perovskite materials with n-butylammonium spacer layers, and integrating these materials into bifacial tandem solar cells providing at least 30% normalized power production. We find that an optimized 2D perovskite ((BA) 2 (MA) 3 (Sn 0.6 Pb 0.4 ) 4 I 13 )/silicon bifacial tandem cell, given a globally average albedo of 30%, yields a normalized power production of 30.31%, which should be stable for extended time periods without further change in materials or encapsulation.

14 SOLAR ENERGY↗

Defect localization, characterization and reliability assessment in emerging photovoltaic devices.

Microsystems-enabled photovoltaics (MEPV) can potentially meet increasing demands for light-weight, portable, photovoltaic solutions with high power density and efficiency. The study in this report examines failure analysis techniques to perform defect localization and evaluate MEPV modules. CMOS failure analysis techniques, including electroluminescence, light-induced voltage alteration, thermally-induced voltage alteration, optical beam induced current, and Seabeck effect imaging were successfully adapted to characterize MEPV modules. The relative advantages of each approach are reported. In addition, the effects of exposure to reverse bias and light stress are explored. MEPV was found to have good resistance to both kinds of stressors. The results form a basis for further development of failure analysis techniques for MEPVs of different materials systems or multijunction MEPVs. The incorporation of additional stress factors could be used to develop a reliability model to generate lifetime predictions for MEPVs as well as uncover opportunities for future design improvements.

14 SOLAR ENERGY↗

Three-dimensional fuel pin model validation by prediction of hydrogen distribution in cladding and comparison with experiment

To correctly describe and predict this hydrogen distribution there is a need for multi-physics coupling to provide accurate three-dimensional azimuthal, radial, and axial temperature distributions in the cladding. Coupled high-fidelity reactor-physics codes with a sub-channel code as well as with a computational fluid dynamics (CFD) tool have been used to calculate detailed temperature distributions. These high-fidelity coupled neutronics/thermal-hydraulics code systems are coupled further with the fuel-performance BISON code with a kernel (module) for hydrogen. Both hydrogen migration and precipitation/dissolution are included in the model. Results from this multi-physics analysis is validated utilizing calculations of hydrogen distribution using models informed by data from hydrogen experiments and PIE data.

36 MATERIALS SCIENCE↗

Photonic Memory Controller Module (P-MCM)

In this Program, a team of industry and academic experts in optical interconnect design have come together to develop optical components and network architectures for the next generation high-bandwidth memory modules for DOE relevant high-performance computing applications.

97 MATHEMATICS AND COMPUTING↗

High Flux Isotope Reactor Low Enriched Uranium U-10Mo Fuel Design Parameters

Activities to convert the HFIR from HEU to LEU are ongoing as part of the US Department of Energy (DOE) National Nuclear Security Administration (NNSA) nuclear nonproliferation mission. Design activities to study the conversion of HFIR from HEU to LEU fuel explored different fuel design features and shapes with a uranium-molybdenum (U-10Mo) monolithic alloy fuel. This high-density alloy contains 90 wt % uranium and 10 wt % molybdenum and has a uranium density of 15.318gU/cm 3 . The goal of these studies is to generate several candidate HFIR LEU fuel designs of varying fuel fabrication complexity that meet the current HEU performance metrics and safety requirements. Recent advancements in modeling and simulation tools and design methods enabled a thorough analysis of the available design space with U-10Mo fuel. A surrogate model used this analysis as training data to quickly determine the performance of a design given specific design parameters. An optimization module used this surrogate model to quickly search this multidimensional search space given specific desired performance characteristics. This approach was made possible by the large available design space with U-10Mo fuel. Shift, a Monte Carlo tool optimized for high-performance computing (HPC) architectures, was used for faster calculation and better data management for reactor physics simulations. Once most of these design studies were complete, a new suite called the Python HFIR Analysis and Measurement Engine (PHAME) was developed to connect all fuel design analysis steps, making design studies more efficient and reproducible. The post-processing capabilities of these new tools are leveraged for the information provided herein. Leveraging these tools, several candidate fuel designs were selected with varying levels of feature complexity and reactor performance. This report provides design feature details for four selected HFIR LEU U-10Mo fuel designs and their corresponding performance and safety metrics. Nominal best-estimate design parameters and irradiation conditions, including fission rate densities, power densities, heat fluxes, and cumulative fission densities, are provided. Simulations show that the high uranium density of U-10Mo fuel provides a large potential design space that enables various LEU designs to meet HEU core performance metrics and safety requirements with a power increase from 85 MW (HEU) to 95 MW or 100 MW (LEU).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model Validation and Uncertainty Quantification on the KRUSTY Microreactor Design Using GRIFFIN Neutron Transport Code [Poster]

Argonne National Laboratory (ANL) and INL have developed a GRIFFIN steady state neutronics model for the multiphysics simulations of the Kilopower Reactor Using Sterling TechnologY (KRUSTY) microreactor in the Multiphysics Object Oriented Simulation Environment (MOOSE). The reliability of such deterministic neutronics models can be validated by comparing with computations from Monte Carlo codes (e.g. MCNP, SERPENT, OpenMC, Shift, etc). Furthermore, potential modeling/design improvements can be identified by incorporating uncertainty quantification (UQ), which can be performed by MOOSE’s Stochastic Tools Module (STM). KRUSTY is a prototype for a 5-kW thermal nuclear-powered space reactor. Its primary components consist of nuclear fuel, heat pipes, a control rod, a reflector, and the shielding. The fuel consists of 3 stacked U-7.65Mo cylinders with a hole in the center for the control rod. 8 liquid sodium heat pipes transfer fission energy from the solid fuel block to the Sterling power conversion system where the energy is extracted, and the cooled sodium flows back to the core via capillary action . The movable Boron Carbide control rod regulates the neutron population during startup or when a reactor temperature boost is needed . The beryllium oxide reflector is in 3 places in the reactor; it surrounds the core axially, it lies beneath the core on a platen, and it is present in the shim. The axial and lower reflectors rest on an adjustable stainless-steel platen that moves upward to cover the fuel and help the reactor reach criticality. Lastly, radial stainless steel surrounds the core offering protection from radiation exposure .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser driven inertial fusion energy technology development

The future of Laser-Based Inertial fusion energy requires the development of efficient diode-pumped laser drivers that can be scaled to megajoule class output operating at ≥ 10-Hz repetition rate. ARPA-E requested a study of the range of possibilities for a 100kJ/10-Hz laser system with >15% wall-plug efficiency operating below 360 nm. The conceptual design of a compact, 1 kJ class module is presented and analyzed for performance relative to the objectives along with a roadmap to demonstrate the technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TRANSIENT GALACTIC COSMIC-RAY MODULATION DURING SOLAR CYCLE 24: A COMPARATIVE STUDY OF TWO PROMINENT FORBUSH DECREASE EVENTS

Forbush decrease (FD) events are of great interest for transient galactic cosmic-ray (GCR) modulation study. In this study, we perform comparative analysis of two prominent Forbush events during cycle 24, occurring on 2012 March 8 (Event 1) and 2015 June 22 (Event 2), utilizing the measurements from the worldwide neutron monitor (NM) network. Despite their comparable magnitudes, the two Forbush events are distinctly different in terms of evolving GCR energy spectrum and energy dependence of the recovery time. The recovery time of Event 1 is strongly dependent on the median energy, compared to the nearly constant recovery time of Event 2 over the studied energy range. Additionally, while the evolutions of the energy spectra during the two FD events exhibit similar variation patterns, the spectrum of Event 2 is significantly harder, especially at the time of deepest depression. These difference are essentially related to their associated solar wind disturbances. Event 1 is associated with a complicated shock-associated interplanetary coronal mass ejection (ICME) disturbance with large radial extent, probably formed by the merging of multiple shocks and transient flows, and which delivered a glancing blow to Earth. Conversely, Event 2 is accompanied by a relatively simple halo ICME with small radial extent that hit Earth more head-on.

79 ASTRONOMY AND ASTROPHYSICS↗

Bifacial Tracking Testbed at NREL

Bifacial demonstration plant with 10 rows of single-axis trackers. Each row is independently monitored and grid tied. This project continues our work on bifacial photovoltaic modeling, field evaluation and standards development.

14 SOLAR ENERGY↗

Examining Light-Induced Degradation with Combined-Accelerated Stress Testing

While further understanding is sought, the results suggest that a module can show no degradation in performance through a qualification test light soak, (IEC 61215: 2021 MQT 19.1 requirement of 10 kW minimum on one side). Yet, such cells may degrade significantly by LID under conditions within the statistical extremes of the natural environment applied in combined-accelerated stress testing (CAST).

combined-accelerated stress testing↗