Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Design, assembly and operation of a Cosmic Ray Tagger based on scintillators and SiPMs

The Mu2e experiment at Fermilab aims to search for the SM forbidden μ – → e – conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and a crystal calorimeter, made of two annular disks. Here, in order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5 x 1.5 x 160 cm 3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of the data acquisition, trigger, and slow control systems of the Mu2e experiment at Fermilab

The Mu2e experiment at the Fermilab will search for a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. In this work, the Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq framework as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several framework components — an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface to its components through a web browser. Data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read out data from the Mu2e Cosmic Ray Veto system. Foundation of the Mu2e DCS, EPICS – an Experimental Physics and Industrial Control System – is an open-source platform for monitoring, controlling, alarming, and archiving. A prototype of the TDAQ and the DCS systems has been built and tested over the last three years at Fermilab’s Feynman Computing Center, and now the production system installation is underway. This work presents their status and focus on the installation plans and procedures for racks, workstations, network switches, gateway computers, DAQ hardware, slow controls implementation, and testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-assisted optimization of the ECCE tracking system at the Electron Ion Collider

The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the “glue” that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5 T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Herein our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Digitizer ReAdout Controller (DiRAC): characterization and radiation hardness

The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.

43 PARTICLE ACCELERATORS↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

A MAPS Based Micro-Vertex Detector for the STAR Experiment

For the 2014 heavy ion run of RHIC a new micro-vertex detector called the Heavy Flavor Tracker (HFT) was installed in the STAR experiment. The HFT consists of three detector subsystems with various silicon technologies arranged in 4 approximately concentric cylinders close to the STAR interaction point designed to improve the STAR detector’s vertex resolution and extend its measurement capabilities in the heavy flavor domain. The two innermost HFT layers are placed at radii of 2.8 cm and 8 cm from the beam line. These layers are constructed with 400 high resolution sensors based on CMOS Monolithic Active Pixel Sensor (MAPS) technology arranged in 10-sensor ladders mounted on 10 thin carbon fiber sectors to cover a total silicon area of 0.16 m 2 . Each sensor of this PiXeL (“PXL”) sub-detector combines a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch together with front-end electronics and zero-suppression circuitry in one silicon die providing a sensitive area of ~3.8 cm 2 . This sensor architecture features 185.6 μs readout time and 170 mW/cm 2 power dissipation. This low power dissipation allows the PXL detector to be air-cooled, and with the sensors thinned down to 50 μm results in a global material budget of only 0.4% radiation length per layer. A novel mechanical approach to detector insertion allows us to effectively install and integrate the PXL sub-detector within a 12 hour period during an on-going multi-month data taking period. The detector requirements, architecture and design, as well as the performance after installation, are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of the potential array output charge in the performance analysis of stand-alone photovoltaic systems without MPPT (Case study: Mediterranean climate)

The potential array output energy, E{sub P}, stated by the Joint Research Centre (JRC) in their European Guidelines for the Assessment of Photovoltaic Plants and the IEC Standard 61724 does not estimate properly the potential array output of stand-alone photovoltaic (SAPV) systems without maximum power point tracker (MPPT) as it is the case for SAPV systems with MPPT and grid connected systems. In this way, the main purpose of this paper is to validate an expression that compromises simplicity and accuracy when estimating the potential array output of SAPV systems without MPPT. This issue can be of high interest to photovoltaic (PV) practitioners and experts as it can improve the analysis performance of this type of systems, helping to discriminate better the different losses in this kind of systems. Furthermore, a study of the array potential estimation through different expressions will be developed in order to evaluate which matches better the array potential output in SAPV system without MPPT. Although the analysis will be focused especially in Mediterranean climates, it will be derived some general conclusions that can be considered in other climates. (author)

14 SOLAR ENERGY↗

Optofluidic solar concentrators using electrowetting tracking: Concept, design, and characterization

We introduce a novel optofluidic solar concentration system based on electrowetting tracking. With two immiscible fluids in a transparent cell, we can actively control the orientation of fluid fluid interface via electrowetting. The naturally-formed meniscus between the two liquids can function as a dynamic optical prism for solar tracking and sunlight steering. An integrated optofluidic solar concentrator can be constructed from the liquid prism tracker in combination with a fixed and static optical condenser (Fresnel lens). Therefore, the liquid prisms can adaptively focus sunlight on a concentrating photovoltaic (CPV) cell sitting on the focus of the Fresnel lens as the sun moves. Because of the unique design, electrowetting tracking allows the concentrator to adaptively track both the daily and seasonal changes of the sun's orbit (dual-axis tracking) without bulky, expensive and inefficient mechanical moving parts. This approach can potentially reduce capital costs for CPV and increases operational efficiency by eliminating the power consumption of mechanical tracking. Importantly, the elimination of bulky tracking hardware and quiet operation will allow extensive residential deployment of concentrated solar power. In comparison with traditional silicon-based photovoltaic (PV) solar cells, the electrowetting-based self-tracking technology will generate,similar to 70% more green energy with a 50% cost reduction. (C) 2013 Elsevier Ltd. All rights reserved.

Cheng, JT↗

Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Solar irradiance computations compared with observations at the Baseline Surface Radiation Network Payerne site

Radiative transfer model calculations of solar fluxes during cloud free periods often show considerable discrepancies with surface radiation observations. Many efforts have been undertaken to explain the differences between modeled and observed shortwave downward radiation (SDR). In this study, MODTRAN4v3r1TM (designed later simply as MODTRANTM) was used for model simulations and compared with high quality radiation observations of the Baseline Surface Radiation Network (BSRN) site at Payerne, Switzerland. Results are presented for cloud free shortwave downward radiation calculations. The median differences of modeled minus observed global SDR are small (< 1%) and within the instrumental error. The differences of modeled and observed direct and diffuse SDR show larger discrepancies of -1.8% and 5.2% respectively. The diffuse SDR is generally overestimated by the model and more important, the model to observation linear regression slope and zero-intercept differs significantly from their ideal values of 1 and 0. Possible reasons for the discrepancies are presented and discussed and some modifications are investigated for decreasing such differences between modeled and observed diffuse SDR. However, we could not resolve all the discrepancies. The best agreement is obtained when comparing model simulations whose 550nm aerosol optical depth input is inferred from observations using nine spectral channels, and using BSRN observations performed with a new and more precise shading disk and sun tracker system. In this case, the median bias between model simulations and observed diffuse SDR is -0.4 Wm-2 (< 1%).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of regional CO2 mole fractions in the ECMWF CAMS real-time atmospheric analysis and NOAA CarbonTracker Near-Real Time reanalysis with airborne observations from ACT-America field campaigns

This study systematically examines the regional uncertainties and biases in carbon dioxide (CO2) mole fractions from two of the state-of-the-art global analysis products, namely the Copernicus Atmosphere Monitoring Service (CAMS) real-time atmospheric analysis from the European Centre for Medium-Range Weather Forecasts and the Carbon- Tracker Near-Real Time (CT-NRT) reanalysis from the National Oceanic and Atmospheric Administration, by evaluation against hundreds of hours of airborne in situ measurements from the summer 2016 and winter 2017 Atmospheric Carbon and Transport (ACT) { America eld campaigns. Both the CAMS and CT-NRT analyses agree reasonably well with the independent ACT-America airborne CO2 measurements in the free troposphere, with root-mean-square deviations (RMSDs) between analyses and observations generally between 1{2 ppm, but show considerably larger uncertainties in the atmospheric boundary layer where the RMSDs are as large as 10 ppm in the lowermost 500 m of the boundary layer. There are strong variations in accuracy and bias between seasons, and across three different sub-regions in the United States (Mid-Atlantic, Midwest and South), with the largest uncertainties in the Mid-Atlantic region in summer. Overall, the RMSDs of the CAMS and CT-NRT analyses against airborne data are comparable to each other, and grossly consistent with the difference between the two analyses. The current study provides uncertainty estimates for both analysis products over North America and suggests that these two independent estimates can be used to approximate regional CO2 analysis uncertainties. Both statistics are important in future studies in quantifying the uncertainties in regional CO2 mole fraction and flux estimates.

Chen, Hans↗