Search NASA⌕ Search

SEARCH · Search NASA

Results for “pattern detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Portable Electronic Nose For Toxic Vapor Detection, Identification, and Quantification

A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to identify and quantify many vapors of interest to the Space Program at their minimum required concentrations for both single vapors and two-component vapor mixtures, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

Linnell, B. R.↗

A Portable Electronic Nose for Toxic Vapor Detection, Identification, and Quantification

The Space Program and military use large quantities of hydrazine and monomethyl hydrazine as rocket propellant, which are very toxic and suspected human carcinogens. Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect these compounds at the minimum required concentrations and are prone to false positives, making them unacceptable for many operations. In addition, post-mission analyses of grab bag air samples from the Shuttle have confirmed the occasional presence of on-board volatile organic contaminants, which also need to be monitored to ensure crew safety. A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to qualify (identify) and quantify many of these vapors at their minimum required concentrations, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

Linnell, B. R.↗

Nulling interferometers: the importance of systematic errors and the X-Array configuration

The nulling interferometers proposed for planet detection are arrays of collector telescopes whose amplitudes and phases are carefully controlled to generate a null response at the star. Perturbations in the amplitude and phase response of the instrument lead to time-dependent fluctuations in the stellar leakage that can mimic a planet signal. Understanding these non-linear systematic errors is important, since they drive most of the instrument requirements for missions such as the Terrestrial Planet Finder and Darwin. We show that 'amplitude-phase' errors are the dominant source of instrument noise. They are unaffected by the technique of phase chopping, increase rapidly at short wavelengths, are largely independent of the size and transmission efficiency of the collector optics, and depend only weakly on the nulling configuration and distance to the target system. Detection of an Earth around a G-type star like the sun requires -1.5 nm of path control and -0.1% control of the amplitude, integrated over all frequencies, including DC. This paper also introduces the X-Array - a new nulling configuration with 4 collectors and a central combiner arranged in an X pattern. This has a number of advantages over the standard dual Bracewell layout, and over other configurations that have been proposed

Dubovitsky, Serge↗

STANSORT - Stanford Remote Sensing Laboratory pattern recognition and classification system

The principal barrier to routine use of the ERTS multispectral scanner computer compatible tapes, rather than photointerpretation examination of the images, has been the high computing costs involved due to the large quantity of information (4 Mbytes) contained in a scene. STANSORT, the interactive program package developed at Stanford Remote Sensing Laboratories alleviates this problem, providing an extremely rapid, flexible and low cost tool for data reduction, scene classification, species searches and edge detection. The primary classification procedure, utilizing a search with variable gate widths, for similarities in the normalized, digitized spectra is described along with associated procedures for data refinement and extraction of information. The more rigorous statistical classification procedures are also explained.

Honey, F. R.↗

Automated Recognition of 3D Features in GPIR Images

A method of automated recognition of three-dimensional (3D) features in images generated by ground-penetrating imaging radar (GPIR) is undergoing development. GPIR 3D images can be analyzed to detect and identify such subsurface features as pipes and other utility conduits. Until now, much of the analysis of GPIR images has been performed manually by expert operators who must visually identify and track each feature. The present method is intended to satisfy a need for more efficient and accurate analysis by means of algorithms that can automatically identify and track subsurface features, with minimal supervision by human operators. In this method, data from multiple sources (for example, data on different features extracted by different algorithms) are fused together for identifying subsurface objects. The algorithms of this method can be classified in several different ways. In one classification, the algorithms fall into three classes: (1) image-processing algorithms, (2) feature- extraction algorithms, and (3) a multiaxis data-fusion/pattern-recognition algorithm that includes a combination of machine-learning, pattern-recognition, and object-linking algorithms. The image-processing class includes preprocessing algorithms for reducing noise and enhancing target features for pattern recognition. The feature-extraction algorithms operate on preprocessed data to extract such specific features in images as two-dimensional (2D) slices of a pipe. Then the multiaxis data-fusion/ pattern-recognition algorithm identifies, classifies, and reconstructs 3D objects from the extracted features. In this process, multiple 2D features extracted by use of different algorithms and representing views along different directions are used to identify and reconstruct 3D objects. In object linking, which is an essential part of this process, features identified in successive 2D slices and located within a threshold radius of identical features in adjacent slices are linked in a directed-graph data structure. Relative to past approaches, this multiaxis approach offers the advantages of more reliable detections, better discrimination of objects, and provision of redundant information, which can be helpful in filling gaps in feature recognition by one of the component algorithms. The image-processing class also includes postprocessing algorithms that enhance identified features to prepare them for further scrutiny by human analysts (see figure). Enhancement of images as a postprocessing step is a significant departure from traditional practice, in which enhancement of images is a preprocessing step.

Park, Han↗

Landsat thematic mapper (TM) soil variability analysis over Webster County, Iowa

Thematic mapper simulator (TMS) data acquired June 7, June 23, and July 31, 1982, and Landsat thematic mapper (TM) data acquired August 2, September 3, and October 21, 1982, over Webster County, Iowa, were examined for within-field soil effects on corn and soybean spectral signatures. It was found that patterns displayed on various computer-generated map products were in close agreement with the detailed soil survey of the area. The difference in spectral values appears to be due to a combination of subtle soil properties and crop growth patterns resulting from the different soil properties. Bands 4 (0.76-.90 micron), 5 (1.55-1.75 micron), and 7 (2.08-2.35 micron) were found to be responding to the within-field soil variability even with increasing ground cover. While these results are preliminary, they do indicate that the soil influence on the vegetation is being detected by TM and should provide improved information relating to crop and soil properties.

Thompson, D. R.↗

Electronic heterodyne readout of fringes in moire deflectometry

An electronic heterodyne technique is described for the readout of fringes in moire deflectometry. The technique is based on phase measurements of signals generated by a photodetector observing the light transmitted through a traveling moire fringe pattern. The phase of the signal is proportional to the fringe deviation and thus to the deflection angle of the light ray. The phase is measured on line by a standard phase meter with an accuracy of 1 deg or 1:360 of a fringe. The technique, which is precise and sensitive, is demonstrated by detecting and measuring a fringe shift of 0.15 mm corresponding to 0.029 of a fringe.

Stricker, J.↗

Resistive synaptic interconnects for electronic neural networks

The use of the alpha-Ge(1-x):Al(x) and alpha-Ge(1-x):Cu(x) alloys and Pt/Al2O3 cermet thin films as resistive interconnects for binary synaptic memory arrays is evaluated. The fabrication of the 10-20 microns long, 10 microns wide, and 0.1 micron thick interconnects from the alloys and cermet is described. The current-voltage and switching characteristics of the as-deposited films and the patterned test structure are studied. The resistivity, uniformity, stability, and compatibility of the interconnects are examined. It is observed that alpha-Ge(1-x):Cu(x) alloys have a wide resistivity range and low temperature coefficients of resistance; however, their long-term stability is limited due to their low crystallization temperature. It is detected that the alpha-Ge(1-x):Al(x) alloys have higher crystallization temperatures and their resistivity is not greatly affected by large changes in metal content. The Pt/Al2O3 samples display excellent stability, easy fabrication, and control of resistivity with metal content.

Lamb, J. L.↗

Growth and characterization of large YBa2Cu3O(7-x) single crystals

Centimeter-sized crystal plates of YBa2Cu3O(7-x) have been obtained using a bulk composition and method described by Schneemeyer at al. (1987) modified for growth in a pure oxygen atmosphere. A porous MgO crucible and long soak time promote large crystals. Mg was not detectable in the crystals. Electron microbeam analysis using a 60 A monochromator crystal for the oxygen determination gave the composition Y(1.05)Ba(2.02)Cu(2.94)O(6.52 + or - 0.06). As-grown crystals from the melt surface exhibit a fairly sharp Tc with zero resistance at 80 K, and show complex twinning and crack patterns. Optical micrographs of a lightly polished surface normal to the c-axis of a 3-mm crystal delineate twinning and fine scale microcracking; this crystal surface now has a zero resistance at 68 K. Microhardness measurements and microfracture observations indicate intrinsic properties that may inhibit or impede large scale manufacture of electronic ceramics.

Keester, Kenneth L.↗

Data compression in digitized lines

The problem of data compression is very important in digital photogrammetry, computer assisted cartography, and GIS/LIS. In addition, it is also applicable in many other fields such as computer vision, image processing, pattern recognition, and artificial intelligence. Consequently, there are many algorithms available to solve this problem but none of them are considered to be satisfactory. In this paper, a new method of finding critical points in a digitized curve is explained. This technique, based on the normalized symmetric scattered matrix, is good for both critical points detection and data compression. In addition, the critical points detected by this algorithm are compared with those by zero-crossings.

Thapa, Khagendra↗

The dielectric-filled parabola - A new millimeter/submillimeter wavelength receiver/transmitter front end

A design is presented for a semi-integrated millimeter/submillimeter wavelength receiver/transmitter front end incorporating a planar antenna and a solid-state device in an efficient feed structure which can be matched directly to high f-number optical systems. The feed system combines the simplicity and robustness of a dielectric substrate lens with the high gain of a parabolic reflector in a single structure that is termed a dielectric-filled parabola. The same fundamental unit can be configured as either a heterodyne or direct detection mode receiver, a power transmitter or a frequency multiplier by changing out the solid-state device and/or the integrated antenna. The structure can also be used with a small integrated antenna array in a multibeam or imaging arrangement. Design and fabrication details for the feed system are given. These are followed by beam pattern and impedance measurements taken on a microwave model when dipole, bow-tie, log-periodic, and log-spiral antennas are used as the integrated feed elements.

Siegel, Peter H.↗

Relationship of Topside Ionospheric Ion Outflows to Auroral Forms and Precipitation, Plasma Waves, and Convection Observed by Polar

The POLAR satellite often observes upflowing ionospheric ions (UFIs) in and near the aurora] oval on southern perigee (approx. 5000 km altitude) passes. We present the UFI features observed by the thermal ion dynamics experiment (TIDE) and the toroidal imaging mass angle spectrograph (TIMAS) in the dusk-dawn sector under two different geomagnetic activity conditions in order to elicit their relationships with auroral forms, wave emissions, and convection pattern from additional POLAR instruments. During the active interval, the ultraviolet imager (UVI) observed a bright discrete aurora on the duskside after the substorm onset and then observed a small isolated aurora form and diffuse auroras on the dawnside during the recovery phase. The UFIs showed clear conic distributions when the plasma wave instrument (PWI) detected strong broadband wave emissions below approx. 10 kHz, while no significant auroral activities were observed by UVI. At higher latitudes, the low-energy UFI conics gradually changed to the polar wind component with decreasing intensity of the broadband emissions. V-shaped auroral kilometric radiation (AKR) signatures observed above -200 kHz by PWI coincided with the region where the discrete aurora and the UFI beams were detected. The latitude of these features was lower than that of the UFI conics. During the observations of the UFI beams and conics, the lower-frequency fluctuations observed by the electric field instrument were also enhanced, and the convection directions exhibited large fluctuations. It is evident that large electrostatic potential drops produced the precipitating electrons and discrete auroras, the UFI beams, and the AKR, which is also supported by the energetic plasma data from HYDRA. Since the intense broadband emissions were also observed with the UFIs, the ionospheric ions could be energized transversely before or during the parallel acceleration due to the potential drops.

Hirahara, M.↗

Twenty Years of NASA-EOS Multi-Sensor Satellite Observations at Kīlauea Volcano (2000–2019)

Recent eruptions of Kīlauea volcano, on the Island of Hawai'i, represent an ideal test location for studying volcanic plumes, due to its remote location and minimal anthropogenic pollution. Within this work we exploit the over 20-year data record from NASA EOS satellites to investigate the degree to which space-borne observations can detect shifts in known eruption dynamics at Kīlauea. Through the combined analysis of remotely sensed plume heights, plume particle microphysical properties, lava flow thermal tracking and high resolution SO2 mapping, we provide interpretations of the satellite signals in a volcanic context and link them to ground-based eruption reports for validation. We establish common patterns of plume dispersion and particle evolution and identify when significant shifts in activity occur. We also determine where ambient conditions influence the output retrieved from the space-borne sensors. By comparing the inferences derived from remote-sensing with the extensive record of suborbital observations at Kīlauea, we assess the strengths and limitations of the satellite-based volcanic assessment techniques. The work presented here highlights the capabilities of these techniques, allowing us to more confidently interpret volcanic activity observed from space globally, particularly in cases where ground observations are limited or entirely lacking.

volcano remote sensing↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗

Mitigating Satellite-Based Fire Sampling Limitations in Deriving Biomass Burning Emission Rates: Application to WRF-Chem Model over the Northern sub-Saharan African Region

Largely used in several independent estimates of fire emissions, fire products based on MODIS sensors aboard the Terra and Aqua polar-orbiting satellites have a number of inherent limitations, including (a) inability to detect fires below clouds, (b) significant decrease of detection sensitivity at the edge of scan where pixel sizes are much larger than at nadir, and (c) gaps between adjacent swaths in tropical regions. To remedy these limitations, an empirical method is developed here and applied to correct fire emission estimates based on MODIS pixel level fire radiative power measurements and emission coefficients from the Fire Energetics and Emissions Research (FEER) biomass burning emission inventory. The analysis was performed for January 2010 over the northern sub-Saharan African region. Simulations from WRF-Chem model using original and adjusted emissions are compared with the aerosol optical depth (AOD) products from MODIS and AERONET as well as aerosol vertical profile from CALIOP data. The comparison confirmed an 30-50% improvement in the model simulation performance (in terms of correlation, bias, and spatial pattern of AOD with respect to observations) by the adjusted emissions that not only increases the original emission amount by a factor of two but also results in the spatially continuous estimates of instantaneous fire emissions at daily time scales. Such improvement cannot be achieved by simply scaling the original emission across the study domain. Even with this improvement, a factor of two underestimations still exists in the modeled AOD, which is within the current global fire emissions uncertainty envelope. Plain Language Summary Polar-orbiting satellites sensors, such as MODIS, have limitations in detecting fires under clouds or when viewing angles are large or in the gaps among satellites' different ground swaths. Here we developed an empirical method to mitigate the effect of these limitations in fire emission estimate. The method is applied to a fire emission inventory (FEER) based on MODIS. We show that, with our method, the adjusted emission inventory improves WRF-Chem simulation of smoke transport and distribution.

emissions properties↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

The detection of 'intermediate' size magnetic anomalies in Cosmos 49 and OGO 2, 4, 6 data.

Benkova, Dolginov and Simonenko have recently reported the presence of intermediate size magnetic anomalies from Cosmos 49 data and hypothesized a crustal and/or upper mantle origin for these. We have examined the spherical harmonic models of the internal potential function, based on the OGO 2, 4 and 6 data and verified the locations and amplitudes of those anomalies with wavelengths of approximately 4000 km. The patterns of delta-F so computed were then compared with the IZMIRAN maps and also were analyzed statistically, in both the spatial and frequency domains, using residuals computed from the raw Cosmos 49 data. The two sets of data were thus derived from completely independent sets of observations and field references. The two patterns are shown to agree very well over the whole earth surface up to the 50 deg latitude limit of Cosmos 49.

Regan, R. D.↗

Trace gas emissions to the atmosphere by biomass burning in the west African savannas

Savanna fires and atmospheric carbon dioxide (CO2) detection and estimating burned area using Advanced Very High Resolution Radiometer_(AVHRR) reflectance data are investigated in this two part research project. The first part involves carbon dioxide flux estimates and a three-dimensional transport model to quantify the effect of north African savanna fires on atmospheric CO2 concentration, including CO2 spatial and temporal variability patterns and their significance to global emissions. The second article describes two methods used to determine burned area from AVHRR data. The article discusses the relationship between the percentage of burned area and AVHRR channel 2 reflectance (the linear method) and Normalized Difference Vegetation Index (NDVI) (the nonlinear method). A comparative performance analysis of each method is described.

Frouin, Robert J.↗