Search NASA⌕ Search

SEARCH · Search NASA

Results for “Behavioral Health”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Reactions and Surface Transformations of a Bone-Bioactive Material in a Simulated Microgravity Environment

A comprehensive program to investigate the expeditious in vitro formation of three-dimensional bone-like tissue is currently underway at the University of Pennsylvania. The study reported here forms a part of that program. Three-dimensional bone-like tissue structures may be grown under the simulated microgravity conditions of NASA designed Rotating Wall Bioreactor Vessels (RWV's). Such tissue growth will have wide clinical applications. In addition, an understanding of the fundamental changes that occur to bone cells under simulated microgravity would yield important information that will help in preventing or minimizing astronaut bone loss, a major health issue with travel or stay in space over long periods of time. The growth of three-dimensional bone-like tissue structures in RWV's is facilitated by the use of microcarriers which provide structural support. If the microcarrier material additionally promotes bone cell growth, then it is particularly advantageous to employ such microcarriers. We have found that reactive, bone-bioactive glass (BBG) is an attractive candidate for use as microcarrier material. Specifically, it has been found that BBG containing Ca- and P- oxides upregulates osteoprogenitor cells to osteoblasts. This effect on cells is preceded by BBG reactions in solution which result in the formation of a Ca-P surface layer. This surface further transforms to a bone-like mineral (i.e., carbonated crystalline hydroxyapatite (c-HA)). At normal gravity, time-dependent, immersion-induced BBG reactions and transformations are greatly affected both by variations in the composition of the milieu in which the glass is immersed and on the immersion conditions. However, the nature of BBG reactions and phase transformations under the simulated microgravity conditions of RWV's are unknown, and must be understood in order to successfully use BBG as microcarrier material in RWV'S. In this paper, we report some of our recent findings in this regard using experimental and numerical methods. BBG composition 45S5, the most reactive among known bone-bioactive glasses, was chosen for the study. BBG 45S5 behavior in physiological solutions was tested in simulated microgravity and compared with that at normal gravity. On the basis of our numerical study, we have chosen the BBG granule size to be in the range 40-70 microns, and a RWV rotational speed of 10 rpm. Our numerical study has shown that these parameters enable the microcarrier to remain suspended in the medium without experiencing collisions with the wall of the vessel. Immersion-induced changes in the solution composition and the material surface were analyzed after immersion.

Radin, S.↗

Closing the Certification Gaps in Adaptive Flight Control Software

Over the last five decades, extensive research has been performed to design and develop adaptive control systems for aerospace systems and other applications where the capability to change controller behavior at different operating conditions is highly desirable. Although adaptive flight control has been partially implemented through the use of gain-scheduled control, truly adaptive control systems using learning algorithms and on-line system identification methods have not seen commercial deployment. The reason is that the certification process for adaptive flight control software for use in national air space has not yet been decided. The purpose of this paper is to examine the gaps between the state-of-the-art methodologies used to certify conventional (i.e., non-adaptive) flight control system software and what will likely to be needed to satisfy FAA airworthiness requirements. These gaps include the lack of a certification plan or process guide, the need to develop verification and validation tools and methodologies to analyze adaptive controller stability and convergence, as well as the development of metrics to evaluate adaptive controller performance at off-nominal flight conditions. This paper presents the major certification gap areas, a description of the current state of the verification methodologies, and what further research efforts will likely be needed to close the gaps remaining in current certification practices. It is envisioned that closing the gap will require certain advances in simulation methods, comprehensive methods to determine learning algorithm stability and convergence rates, the development of performance metrics for adaptive controllers, the application of formal software assurance methods, the application of on-line software monitoring tools for adaptive controller health assessment, and the development of a certification case for adaptive system safety of flight.

Jacklin, Stephen A.↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthetic method of analogues for emerging infectious disease forecasting

The Method of Analogues (MOA) has gained popularity in the past decade for infectious disease forecasting due to its non-parametric nature. In MOA, the local behavior observed in a time series is matched to the local behaviors of several historical time series. The known values that directly follow the historical time series that best match the observed time series are used to calculate a forecast. This non-parametric approach leverages historical trends to produce forecasts without extensive parameterization, making it highly adaptable. However, MOA is limited in scenarios where historical data is sparse. This limitation was particularly evident during the early stages of the COVID-19 pandemic, where the emerging global epidemic had little-to-no historical data. In this work, we propose a new method inspired by MOA, called the Synthetic Method of Analogues (sMOA). sMOA replaces historical disease data with a library of synthetic data that describe a broad range of possible disease trends. This model circumvents the need to estimate explicit parameter values by instead matching segments of ongoing time series data to a comprehensive library of synthetically generated segments of time series data. We demonstrate that sMOA has competitive performance with state-of-the-art infectious disease forecasting models, out-performing 78% of models from the COVID-19 Forecasting Hub in terms of averaged Mean Absolute Error and 76% of models from the COVID-19 Forecasting Hub in terms of averaged Weighted Interval Score. Additionally, we introduce a novel uncertainty quantification methodology designed for the onset of emerging epidemics. Developing versatile approaches that do not rely on historical data and can maintain high accuracy in the face of novel pandemics is critical for enhancing public health decision-making and strengthening preparedness for future outbreaks.

97 MATHEMATICS AND COMPUTING↗

Effects of exposure to 56Fe particles or protons on fixed-ratio operant responding in rats

On long-duration trips outside of the magnetosphere, astronauts will be exposed to protons and to heavy particles which can affect their performance of required tasks. It is essential to determine the range of behaviors that might be affected by exposure to these types of radiation in order to understand the nature of behavioral deficits and to develop effective countermeasures. The present experiment examined the ability of rats to make an operant response following exposure to protons (250 MeV, 4 Gy) or 56Fe particles (1 GeV/n, 1 or 2 Gy). Following irradiation, rats were trained to press a lever in order to obtain food reinforcement. They were then placed on an ascending fixed-ratio schedule from FR-1 (each lever press rewarded with a food pellet) through FR-35 (35 lever presses required for 1 food pellet). Rats exposed to 4 Gy of protons or 1 Gy of 56Fe particles responded similarly to controls, increasing their rate of responding as the ratio increased. However, rats exposed to 2 Gy of 56Fe particles failed to increase their rate of responding at ratios greater than FR-20, indicating that rats exposed to 2 Gy of 56Fe particles cannot respond appropriately to increasing work requirements.

Non-NASA Center↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Exposure to airborne metals and particulate matter and risk for youth adjudicated for criminal activity

Antisocial behavior is a product of multiple interacting sociohereditary variables, yet there is increasing evidence that metal exposure, particularly, manganese and lead, play a role in its epigenesis. Other metals, such as arsenic, cadmium, chromium, and mercury, and exposure to traffic-related air pollution, such as fine particulate matter ({<=}2.5 {mu}m) have been associated with neurological deficits, yet largely unexplored with respect to their relationship with delinquent behavior. The purpose of this study is to evaluate the ecological relationship between county-wide reported airborne emissions of air metals, particulate matter, and youth adjudicated for criminal activity. Metal exposure data were collected from the Environmental Protection Agency AirData. Population statistics were obtained from the United States Census 2000 and adjudication data was obtained from the Courts of Common Pleases from each Ohio County. Simple correlations were calculated with the percentage of adjudications, all covariates, and estimated metal air emissions. Separate negative binomial regression models for each pollutant were used to provide an estimated risk ratio of pollutant emissions on the risk of adjudication for all Ohio counties adjusting for urban-rural residence, percentage of African Americans, median family income, percentage of family below poverty, percentage of high school graduation in 25 years and older populations, and population density. Metal emissions and PM in 1999 were all correlated with adjudication rate (2003-2005 average). Metal emissions were associated with slightly higher risk of adjudication, with about 3-4% increased risk per natural log unit of metal emission except chromium. The associations achieved statistical significance for manganese and mercury. The particulate matter {<=}2.5 and {<=}10 {mu}m emissions had a higher risk estimate, with 12% and 19% increase per natural log unit emission, respectively, and also achieved statistical significance. In summary, airborne exposure to manganese, mercury, and particulate matter are associated with increased risk of adjudication. Causality cannot be proven in observational studies such as this one, but the association warrants further examination in other research studies. Comprehensive epidemiologic investigations of metal exposure in pediatric populations should include social health outcomes, including measures of delinquent or criminal activity. Furthermore, the influence of metals on the neurotoxic pathway leading to delinquent activity should be further explored. - Highlights: Black-Right-Pointing-Pointer We evaluate the relationship between air pollutants and adjudication. Black-Right-Pointing-Pointer Manganese, mercury, and particulate matter are associated with risk of adjudication. Black-Right-Pointing-Pointer Further research of metal exposure should include social health outcomes.

60 APPLIED LIFE SCIENCES↗

Managing Through Continuous Improvement: If it doesn’t challenge you, it won’t change you

The past 24 months has been one of non-stop continuous improvement – every month, every week, every day, and every hour. It has been filled with continuously re-examining and challenging business systems, work processes, and legacy culture. The journey was difficult, but well worth it. It began by examining the existing conditions in each organization and building the case for change. When we stepped back and looked at our processes, systems, tools, and performance objectively, we realized we were struggling with frequent organizational, resource, and schedule conflicts, work processes that were not well-defined or expert based, project delays were common, management methods were predominantly reactive, advanced planning was limited to the near-term, no integration in scheduling across organizations, limited to no performance metrics to measure and manage performance, and internal and external customers did not feel like we were meeting their quality and performance expectations. It was a wake-up call. Change began at the top with a change leadership with where a new vision, expectations, and commitment were established. Leaving no stone left unturned, every aspect of the business was challenged which opened up communication and exposed the gaps. This was done in a ‘safe’ environment allowing for honest and solution-oriented discussion and action. The leadership team committed to managing through continuous improvement. The organizational structure was realigned to better align scope, responsibilities, execution, and customer focus. Visibility and transparency became the norm as higher levels of leadership and supporting organizations were invited to be part of regular strategy meetings and partnership discussion, effectively opening up the dialogue. This required a tremendous amount of trust and faith in a short period of time. Health assessments were conducted on each organization with specific lines of inquiry. These self-assessments helped to identify better define the scope of the organization and where targeted improvements were needed. Frequent organizational reviews were implemented to answer three fundamental questions: 1) What is your organization paid to do (scope)?, 2) How does your organization, or you, demonstrate that you are doing the job effectively?, and 3) What are you doing to improve your performance? To answer the first question, leaders defined the scope of the organization. Leaders were required to provide a path forward, with specific actions, where performance was not at expected levels internally at first and then from the stakeholders. Where business processes were not clearly understood, process maps were developed to provide this clarity for both those performing the work and those utilizing the process – the customers. To help answer the second question, numerous automated or semi-automated real-time, dynamic performance metrics were developed and implement to help leaders gain the visibility and demonstrate performance in six areas of operational excellence: safety, security, quality, effectiveness, productivity, and sustainability. Analysis of the performance provided windows of transparency and trends of work performance, work delays, cycle times, utilization, and much more that revealed many areas of improvement that were either not visible or desired to be visible. At the same time, they provided real-time progress which generated initial performance improvements by just beginning to measure. To address the third question, where systems did not support effectiveness of an existing or new process, then systems and tools were developed and implemented to drive the right behaviors and reinforce the processes. Tools and metrics were one of the major catalysts for culture shift and change. Risk assessments were leveraged into continuous improvement strategies, plans, and schedules. Targeted initiatives were identified and performed. Change and improvement was not, and is not, without significant and common challenges including limited/fixed budgets, resource availability, data access, natural resistance to change, and numerous other reasons or excuses – we called them ‘off-ramps’ and began to close them one-by-one. The results and outputs were significant and impactful in each organization and across the business with increased productivity, efficiency, visibility, accountability, management, and performance. Stakeholder satisfaction also increased. Cost and time savings allowed to more continuous improvement efforts to be performed. The effort clearly provided clear and measurable return on investment and value. Efforts that once seemed impossible, not feasible, or not achievable were performed. Decades-long issues were solved. ‘Impossible things are simply those which so far have never been done’ said Elbert Hubbard. So what will the next year be for you and your organization? Are you satisfied with the ‘same ‘ol, same ‘ol?’ Will you fall into the complacency trap and believe that change is too difficult, too expensive, and not necessary (or any number of possible excuses) or will you make this year your year or continuous improvement (and every year thereafter…)? Remember – what you do today can improve all your tomorrows’ (Ralph Marston).

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial temporal cluster analysis to enhance awareness of disease re-emergence on a global scale

ObjectiveThe application of spatial analysis to improve the awareness and use of surveillance data.IntroductionThe re-emergence of an infectious disease is dependent on social, political, behavioral, and disease-specific factors. Global disease surveillance is a requisite of early detection that facilitates coordinated interventions to these events. Novel informatics tools developed from publicly available data are constantly evolving with the incorporation of new data streams. Re-emerging Infectious Disease (RED) Alert is an open-source tool designed to help analysts develop a contextual framework when planning for future events, given what has occurred in the past. Geospatial methods assist researchers in making informed decisions by incorporating the power of place to better explain the relationships between variables.MethodsDisease incidence and indicator data derived for the RED Alert project were analyzed for spatial associations. Using aggregate country-level data, spatial and spatiotemporal clusters were identified in ArcMap 10.5.1. The identified clusters were then used as the outcome for a series of binary logistic regression models to determine significant covariates that help explain global hotspots. These methods will continue to evolve and be incorporated into the RED Alert decision support ecosystem to provide analysts with a global perspective on potential re-emergence.ResultsHotspots of high disease incidence in relation to neighboring countries were identified for measles, cholera, dengue, and yellow fever between 2000 and 2014. Disease-specific predictors were identified using aggregate estimates from World Bank indicator dataset. Data was imputed where possible to enhance the validity of the Gi * statistic for clustering. In the future, as data streams become more readily available, hotspot modeling at a finer resolution will help to improve the precision of spatial epidemiology.ConclusionsSpatial methods enhance the capability of understanding complex population and disease relationships, which in turn improves surveillance and the ability to predict re-emergence. With tools like RED Alert, public health analysts can better prepare to respond rapidly to future re-emerging disease threats.

Altherr, Forest M.↗

Behavioral Makers to Assess During Selection for Active and Non-Active Astronauts

INTRODUCTION: NASA and our international partners seek to stay ahead of the evolving nature of the astronaut role. Spaceflight comes with various risks to team and individual. NASA has worked with its international partners in developing selection guidelines for minimal behavioral competencies needed upon selection. Training should be provided on the remaining behavioral competencies required for spaceflight. We will provide an overview of the process of identifying competencies important to assess as part of a multi-method selection program for active and non-active astronauts. TOPIC: NASA, ESA, CSA, and JAXA agency representatives used their vast combined knowledge and experience to develop competency requirement standards that future selection programs should assess when selecting astronauts. The astronaut role is expanding to include astronauts whose purposes are quite varied. NASA and its international partners identified the need to identify what competencies are required for anyone who will be experiencing the incredible demands, risks, and unique circumstances associated with spaceflight. Competencies include those required for individual and team functioning within the isolated, confined, and extreme environment. This need grew out of greater commercialization of spaceflight and other budding spaceflight prospects. 1. Each agency rated previously defined spaceflight required competencies (not important 0, somewhat important .5, or extremely important 1) to assess during selection. We did this for short duration (<14 days) and for long duration (<14 days) missions as some competencies appear to become of greater importance with longer duration missions. 2. We rated competencies for non-active crew and revisited previous ratings for active crew. 3. We compared agency ratings for non-active/active and short-duration/long-duration requirements and discussed in ratings until consensus was reached. We will use ratings to compile selection standards for active and non-active astronauts. APPLICATION: Our working group has vast operational experience and knowledge of the risk factors present during spaceflight that can disrupt individual and team functioning. Selection is one of the most important countermeasures for mitigating risk to individual and team health and performance. Our work should inform future programs for selecting crewmembers for short- and long-duration spaceflight among active and non-active crews.

Alexa Baxley↗

Human in vitro metabolism of an environmental mixture of polycyclic aromatic hydrocarbons (PAH) found at the Portland Harbor Superfund Site

Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental contaminants that pose health risks to humans. Toxicity testing approaches of PAHs have evolved from traditional rodent models to New Approach Methodologies (NAMs), such as high-throughput screening in zebrafish, enabling rapid evaluation of chemical hazards. However, translating toxicity findings from laboratory systems to humans remains difficult due to complexity and species-specific differences. Chemical dosimetry modeling offers a quantitative framework to bridge this gap, but its accuracy depends on robust knowledge of PAH metabolism. The objective of this study was to measure human metabolism rates of Supermix-10, the ten most abundant PAHs found at the Portland Harbor Superfund Site, to support development of human pharmacokinetic models. We incubated individual PAHs from Supermix-10 in pooled human liver microsomes and quantified parent PAH disappearance using high-performance liquid chromatography (HPLC) with UV and florescent detection. To assess the potential of mixture interactions, we also measured metabolism of all 10 compounds in an equimolar mixture and compared rates of parent disappearance to those observed for individual PAHs. All Supermix-10 PAHs demonstrated rapid parent compound disappearance in human hepatic microsomes. PAHs grouped into three metabolism patterns: high metabolism rates and capacity (2-methylnaphthalene, acenaphthylene, fluorene, naphthalene), high affinity metabolism that rapidly achieves low-level saturation (benzo[a]anthracene, chrysene), and moderate metabolism rates and capacity (fluoranthene, pyrene, retene, phenanthrene). Smaller PAHs exhibited faster metabolism, and higher metabolism rates correlated inversely with molecular weight. When incubated in an equimolar mixture, Supermix-10 demonstrated significantly slower metabolism (47–89 %) compared to metabolism of individual PAHs at the same concentration. These findings enhance our understanding of PAH metabolism in humans and demonstrate significant mixture interactions under the conditions tested. Furthermore, our findings offer insights into the metabolic behavior of Supermix-10 and provide critical metabolism rate data to support the development of physiological based pharmacokinetic (PBPK) models. Dosimetry models can translate PAH chemical dosimetry from high-throughput testing platforms, like zebrafish and cellular system assays, to human exposures enhancing the accuracy and reliability of PAH risk assessments.

2-methylnaphthalene↗

Inductive System Monitors Tasks

The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of the actual failure event. In the Aeronautics Research Mission Directorate, IMS successfully performed real-time engine health analysis. IMS was able to detect simulated failures and actual engine anomalies in an F/A-18 aircraft during the course of 25 test flights. IMS is also being used in colla

Source record↗

The impact of adjusting for hysterectomy prevalence on cervical cancer incidence rates and trends among women aged 30 years or older—United States, 2001-2019

Abstract Hysterectomy protects against cervical cancer when the cervix is removed. However, measures of cervical cancer incidence often fail to exclude women with a hysterectomy from the population-at-risk denominator, underestimating and distorting disease burden. In this study, we estimated hysterectomy prevalence from the Behavioral Risk Factor Surveillance System surveys to remove the women who were not at risk of cervical cancer from the denominator and combined these estimates with the US Cancer Statistics data. From these data, we calculated age-specific and age-standardized incidence rates for women aged >30 years from 2001-2019, adjusted for hysterectomy prevalence. We calculated the difference between unadjusted and adjusted incidence rates and examined trends by histology, age, race and ethnicity, and geographic region using joinpoint regression. The hysterectomy-adjusted cervical cancer incidence rate from 2001-2019 was 16.7 per 100 000 women—34.6% higher than the unadjusted rate. After adjustment, incidence rates were higher by approximately 55% among Black women, 56% among those living in the East South Central division, and 90% among women aged 70-79 and ≥80 years. These findings underscore the importance of adjusting for hysterectomy prevalence to avoid underestimating cervical cancer incidence rates and masking disparities by age, race, and geographic region. This article is part of a Special Collection on Gynecological Cancers.

Public, Environmental & Occupational Health↗

Effect of meteorological parameters on fine and coarse particulate matter mass concentration in a coal-mining area in Zonguldak, Turkey

In this work, the effect of meteorological parameters and local topography on mass concentrations of fine (PM2.5) and coarse (PM2.5-10) particles and their seasonal behavior was investigated. A total of 236 pairs of samplers were collected using an Anderson Dichotomous sampler between December 2004 and October 2005. The average mass concentrations of PM2.5, PM2.5-10, and particulate matter less than 10 m in aerodynamic diameter (PM10) were found to be 29.38, 23.85, and 53.23 {mu}g/m{sup 3}, respectively. The concentrations of PM2.5 and PM10 were found to be higher in heating seasons (December to May) than in summer. The increase of relative humidity, cloudiness, and lower temperature was found to be highly related to the increase of particulate matter (PM) episodic events. During non-rainy days, the episodic events for PM2.5 and PM10 were increased by 30 and 10.7%, respectively. This is a result of the extensive use of fuel during winter for heating purposes and also because of stagnant air masses formed because of low temperature and low wind speed over the study area. 54 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Drilling, Completion, and Data Collection Plans An Assessment of Geological Carbon Sequestration Options in the Illinois Basin: Phase III

Executive Summary The Illinois Basin – Decatur Project (IBDP) is managed by the Midwest Geological Sequestration Consortium (MGSC) and is led by the Illinois State Geological Survey (ISGS) at the University of Illinois. The project site is located on the Archer Daniels Midland Company (ADM) property in Decatur, Illinois, and is a fully integrated carbon capture and storage (CCS) project that uses CO₂ captured from the ethanol-producing fermentation process at the ADM corn-processing plant (Finley et. al., 2013). IBDP has a goal of injecting one million tonnes of CO₂ into the basal sands of the Mt. Simon Sandstone over a three-year period. This is a multifaceted project, and this report details the planning and results of the drilling, completions, well testing, log data acquisition, and the Health, Safety, and Environment (HSE) aspects of the project. Three deep wells were planned for the IBDP: • The injection well: Injection Well #1 (CCS1); • The monitoring well (both in-zone and above seal): Verification Well #1 (VW1); and • The geophone monitoring well: Geophysical Monitoring Well #1 (GM1). The detailed plans for these wells are attached to the appendices of this document. The wells were drilled successfully with little deviation from the original plans. The biggest change from the plan to execution was the need to adjust for larger-than-expected loss of circulation in the Potosi section of the Knox Formation. The completions reports also attached to this document detail the well constructions as they were actually built. Injectivity testing was carried out, and the perforating plans were adjusted based on the results. Additional perforations and acidizing were performed as a result of the injectivity testing. The testing plans are detailed in this report along with the actual testing results. The injectivity testing results were used in the modeling and simulation efforts. Detailed HSE plans were developed and implemented during the planning and execution phases of the project. The implementation included an HSE Bridging Document, which served to unify the HSE policies of the project partners and key subcontractors. The HSE plan and actual HSE results are presented in this document. There were no recordable HSE incidents during the project. A detailed logging program was developed based on project needs. The log data were acquired in accordance with the plan, and both the plan and log results are presented in this report. Log data were heavily utilized by the research staff, modelers, reservoir engineers, and for technical and permitting efforts. 5 Several key lessons were learned during the project: • Safety in operations and execution is paramount and is only achieved through proper planning and behavior control. The certainty of this was reinforced through implementation of this lesson and the resultant flawless HSE performance during the project. • Losses of drilling fluid circulation were larger than anticipated within the Potosi Formation. Circulation was only recovered through cementing the loss zones. • When possible, minimizing complexity in permit requirements and well designs is preferable. • The size of the wells were outside of the standard experience and expertise typical within the basin, and therefore required substantial planning and ramp-up of contractors and partners to meet project objectives. • With multiple stakeholders and research partners, establishing objectives and requirements early and adhering to change request procedures throughout the project are critical to manage competing data and sampling objectives that may be detrimental to overall progress. The well construction and completion operations were successfully executed, with all wells built in a manner that achieved excellent wellbore integrity. Log planning involved a number of stakeholders and technical specialists. Data collection from logging, coring, and testing was excellent. Time and effort spent with the associated contractors and suppliers to develop a well plan beyond normal scope proved highly successful, resulting in a well-construction and completion project that surpassed expectations. The world-class HSE results also demonstrate the commitment of all stakeholders in the project. The details follow in the body of this document

01 COAL, LIGNITE, AND PEAT↗

Standard measures in Analogs of Spaceflight

Standard measures are defined as research measures (physiological, performance, or otherwise) that quantify the subject’s health and performance before, during, and after a spaceflight or a spaceflight analog mission. The Standard Measures Cross-Cutting Project (SMCCP) collects and analyzes standard measures that support assessment and quantification of health risks and efficacy of countermeasures and technologies required to prevent or mitigate adverse outcomes from exposure to the spaceflight environment. SMCCP uses the following spaceflight analogs: - Human Exploration Research Analog (HERA) in Houston, TX: 4-person isolation/confinement; nominal mission duration of 45 days; run by the Human Research Program (HRP). SMCCP uses weekly questionnaires to gather data on the crewmembers’ emotional and mental state and collects blood samples biweekly to measure crewmembers’ serum cortisol levels at the start, middle, and end of the mission. - Institute for Biomedical Problems (IBMP) Ground-Based Experimental Complex, called NEK, in Moscow, Russia: 6-person isolation/confinement; duration of 8 months; run by IBMP. Standard measures data collected during NEK are the same as for HERA above. - :envihab in Cologne, Germany: 12-person bed rest facility; closed environment; 30 to 60-day campaigns; run by the German Aerospace Center (DLR). For bedrest studies, SMCCP uses the international standard measures as documented in the International Academy of Astronautics publication titled Guidelines for Standardization of Bed Rest Studies in the Spaceflight Context (June 2014). These international standard measures evaluate potential changes in bone, muscle, cardiovascular, and visual systems, as well as changes in psychology and nutrition. The international standard measures complement those collected during studies by individual investigators and allow comparison of responses across different bed rest and countermeasures durations. In this presentation, we will review available SMCCP data collected during the recent isolation studies in HERA (C6) and NEK (SIRIUS-21), and during the SANS (SM1, SM2) bed rest studies in :envihab. These standard measures datasets are made available to concurrent investigators in the given mission or campaign via data sharing agreements and/or data sharing plans and to other investigators that have been granted retrospective access to the data (researchers with IRB approved protocols, risk custodians) to advance understanding of physiological and behavioral risks associated with these spaceflight analogs.

Standard Measures↗