Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE-Night

The Lunar Surface Electromagnetics Explorer - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio quiet farside of the Moon. The LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50MHz band. The engineering model (EM) of the four-channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE-Night. Three mitigation techniques have been implemented and verified to suppress self-induced electromagnetic interference (EMI). The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024

47 OTHER INSTRUMENTATION↗

Particle beam and crabbing and deflecting structure

A new type of structure for the deflection and crabbing of particle bunches in particle accelerators comprising a number of parallel transverse electromagnetic (TEM)-resonant) lines operating in opposite phase from each other. Such a structure is significantly more compact than conventional crabbing cavities operating the transverse magnetic TM mode, thus allowing low frequency designs.

47 OTHER INSTRUMENTATION↗

Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

A single-crystal silicon carbide (SiC) detector was used for measurements of soft x rays, electrons, and ion emission from laser-generated plasma obtained with the use of the Prague Asterix Laser System (PALS) at intensities of the order of 10{sup 16} W/cm{sup 2} and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the nature of the irradiated target. The spectra obtained by using the SiC detector show not only the photopeak due to UV and soft x-ray detection, but also various peaks due to the detection of energetic charged particles. Time-of-flight technique was employed to determine the ion kinetic energy of particles emitted from the plasma and to perform a comparison between SiC and traditional ion collectors. The detector was also employed by inserting absorber films of different thickness in front of the SiC surface in order to determine, as a first approximation, the mean energy of the soft x-ray emission from the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Progress in Cell Marking for Synchrotron X-ray Computed Tomography

Recently there has been an increase in research activity into finding ways of marking cells in live animals for pre-clinical trials. Development of certain drugs and other therapies crucially depend on tracking particular cells or cell types in living systems. Therefore cell marking techniques are required which will enable longitudinal studies, where individuals can be examined several times over the course of a therapy or study. The benefits of being able to study both disease and therapy progression in individuals, rather than cohorts are clear. The need for high contrast 3-D imaging, without harming or altering the biological system requires a non-invasive yet penetrating imaging technique. The technique will also have to provide an appropriate spatial and contrast resolution. X-ray computed tomography offers rapid acquisition of 3-D images and is set to become one of the principal imaging techniques in this area. Work by our group over the last few years has shown that marking cells with gold nano-particles (GNP) is an effective means of visualising marked cells in-vivo using x-ray CT. Here we report the latest results from these studies. Synchrotron X-ray CT images of brain lesions in rats taken using the SYRMEP facility at the Elettra synchrotron in 2009 have been compared with histological examination of the tissues. Some deductions are drawn about the visibility of the gold loaded cells in both light microscopy and x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pierre Auger Project and Enhancements

The current status of the scientific results of the Auger Observatory will be discussed which include spectrum, anisotropy in arrival directions, chemical composition analyses, and limits on neutrino and photon fluxes. A review of the Observatory detection systems will be presented. Auger has started the construction of its second phase which encompasses antennae for radio detection of cosmic rays, high-elevation telescopes, and surface plus muon detectors. Details will be presented on the latter, AMIGA (Auger Muons and Infill for the Ground Array), an Auger project consisting of 85 detector pairs each one composed of a surface water-Cherenkov detector and a buried muon counter. The detector pairs are arranged in an array with spacings of 433 and 750 m in order to perform a detailed study of the 10{sup 17} eV to 10{sup 19} eV spectrum region. Preliminary results on the performance of the 750 m array of surface detectors and the first muon counter prototype will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study on ion-irradiation-induced ferromagnetism in FeRh intermetallic compound by means of magnetic Compton scattering

The magnetic Compton profiles of Fe-50 at. % Rh intermetallic compound were measured to study the ferromagnetism induced by 200 MeV Xe ion irradiation. The magnetic effect at 50 K increases with increasing the ion-fluence. The analysis of the experimental result revealed that the values of spin moment induced by the irradiation were close to the values of magnetization obtained by a superconducting quantum interference device magnetometer, suggesting that the ion irradiation mainly induces the spin magnetic moment. The difference in magnetic Compton profiles between the irradiation-induced ferromagnetism and the intrinsic ferromagnetism in pure Fe is also discussed.

36 MATERIALS SCIENCE↗

Results from the High Resolution Fly's Eye Experiment

The High Resolution Fly's Eye (HiRes) Experiment operated two fluorescence detector sites in the western Utah desert between 1997 and 2006. The HiRes results on the cosmic ray spectrum are consistent with the GZK Suppression predicted at 10{sup 19.8} eV and observe an ankle structure at 10{sup 18.5} eV. These spectral features are consistent with a proton-dominated composition for cosmic rays at the highest energies. The HiRes composition studies of both the mean and the variance of the shower maximum depth (X{sub max}) also give results that are completely consistent with a predominately protonic composition, and inconsistent with heavy nuclei such as iron. We also report on the result of anisotropy studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CIRCULAR POLARIZATION OF PULSAR WIND NEBULAE AND THE COSMIC-RAY POSITRON EXCESS

Recent observations by the PAMELA and AMS-02 telescopes have uncovered an anomalous rise in the positron fraction at energies above 10 GeV. One possible explanation for this excess is the production of primary electron/positron pairs through electromagnetic cascades in pulsar magnetospheres. This process results in a high multiplicity of electron/positron pairs within the wind-termination shock of pulsar wind nebulae (PWNe). A consequence of this scenario is that no circular polarization should be observed within PWNe, since the contributions from electrons and positrons exactly cancel. Here we note that current radio instruments are capable of setting meaningful limits on the circular polarization of synchrotron radiation in PWNe, which observationally test the model for pulsar production of the local positron excess. The observation of a PWN with detectable circular polarization would cast strong doubt on pulsar interpretations of the positron excess, while observations setting strong limits on the circular polarization of PWNe would lend credence to these models. Finally, we indicate which PWNe are likely to provide the best targets for observational tests of the AMS-02 excess.

79 ASTRONOMY AND ASTROPHYSICS↗

Global analysis of data on the spin-orbit-coupled A {sup 1{Sigma}}{sub u}{sup +} and b {sup 3{Pi}}{sub u} states of Cs{sub 2}

We present experimentally derived potential curves and spin-orbit interaction functions for the strongly perturbed A {sup 1{Sigma}}{sub u}{sup +} and b {sup 3{Pi}}{sub u} states of the cesium dimer. The results are based on data from several sources. Laser-induced fluorescence Fourier transform spectroscopy (LIF FTS) was used some time ago in the Laboratoire Aime Cotton primarily to study the X {sup 1{Sigma}}{sub g}{sup +} state. More recent work at Tsinghua University provides information from moderate resolution spectroscopy on the lowest levels of the b {sup 3{Pi}}{sub 0u}{sup {+-}} state as well as additional high-resolution data. From Innsbruck University, we have precision data obtained with cold Cs{sub 2} molecules. Recent data from Temple University was obtained using the optical-optical double resonance polarization spectroscopy technique, and finally, a group at the University of Latvia has added additional LIF FTS data. In the Hamiltonian matrix, we have used analytic potentials (the expanded Morse oscillator form) with both finite-difference (FD) coupled-channel and discrete variable representation (DVR) calculations of the term values. Fitted diagonal and off-diagonal spin-orbit functions are obtained and compared with ab initio results from Temple and Moscow State universities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

{gamma}-ray spectroscopy of {sub 17}{sup 38}Cl using grazing reactions

Excited states of {sub 17}{sup 38}Cl{sub 21} were populated in binary grazing reactions during the interaction of a beam of {sub 16}{sup 36}S{sub 20} ions of energy 215 MeV with a {sub 82}{sup 208}Pb{sub 126} target. The combination of the PRISMA magnetic spectrometer and the CLARA {gamma}-ray detector array was used to identify the reaction fragments and to detect their decay via {gamma}-ray emission. A level scheme for {sup 38}Cl is presented and discussed within the context of the systematics of neighboring nuclei and is compared with the results of state-of-the-art shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of K{sup -}p radiative capture to gammaLAMBDA and gammaSIGMA{sup 0} for p{sub K}{sup -} between 514 and 750 MeV/c

Differential cross sections for K{sup -} radiative capture in flight on the proton, leading to the gammaLAMBDA and gammaSIGMA{sup 0} final states, have been measured at eight K{sup -} momenta between 514 and 750 MeV/c. The data were obtained with the Crystal Ball multiphoton spectrometer installed at the separated K/pi beam line C6 of the BNL Alternating Gradient Synchrotron. The results substantially improve the existing experimental data available for studying radiative decays of excited hyperon states. An exploratory theoretical analysis is performed within the Regge-plus-resonance approach. According to this analysis, the gammaSIGMA{sup 0} final state is dominated by hyperon-resonance exchange and hints at an important role for a resonance in the mass region of 1700 MeV. In the gammaLAMBDA final state, in contrast, the resonant contributions account for only half the strength, and the data suggest the importance of a resonance in the mass region of 1550 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of the {gamma}p{yields}{eta}p reaction with the Crystal Ball detector at the Mainz Microtron (MAMI-C)

The {gamma}p{yields}{eta}p reaction has been measured with the Crystal Ball and TAPS multiphoton spectrometers in the energy range from the production threshold of 707 MeV to 1.4 GeV (1.49{<=}W{<=}1.87 GeV). Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz Microtron MAMI-C and momentum analyzed by the Glasgow tagging spectrometer were used for the {eta}-meson production. Our accumulation of 3.8x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events allows a detailed study of the reaction dynamics. The {gamma}p{yields}{eta}p differential cross sections were determined for 120 energy bins and the full range of the production angles. Our data show a dip near W=1680 MeV in the total cross section caused by a substantial dip in {eta} production at forward angles. The data are compared to predictions of previous SAID and MAID partial-wave analyses and to the latest SAID and MAID fits that included our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Revisit the radiative decays of J/{psi} and {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '})

With the new measurements of J/{psi} and {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}) from the CLEO and BES-III collaboration, we reinvestigate the intermediate meson loop (IML) contributions to these radiative decays in association with the quark model M1 transitions in an effective Lagrangian approach. It shows that the ''unquenched'' effects due to the intermediate hadron loops can be better quantified by the new data for J/{psi}{yields}{gamma}{eta}{sub c}. Although the IML contributions are relatively small in J/{psi}{yields}{gamma}{eta}{sub c}, they play a crucial role in {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}). A prediction for the IML contributions to {psi}(3770){yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}) is made. Such unquenched effects allow us to reach a coherent description of those three radiative transitions, and gain some insights into the underlying dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theory, observations, and simulations of kinetic entropy in a magnetotail electron diffusion region

In this work, we examine velocity-space kinetic entropy, a spatially local measure of entropy for systems out of thermal equilibrium, during an encounter of an electron diffusion region at a magnetic reconnection site in Earth’s magnetotail by the Magnetospheric Multiscale (MMS) mission. We start by generalizing the theory of kinetic entropy to the case of non-uniform velocity space grids and transforming the equations into spheri- cal energy coordinates useful to experimental plasma detectors. The theory is then applied to MMS data and compared to particle-in-cell simulations of reconnection. We demonstrate that the entropy-based non-Maxwellianity measure from the MMS data is of sufficiently high precision to reliably identify non-Maxwellian distributions and therefore the measurements when kinetic effects are most significant. By comparing two different non-Maxwellian measures, we show that total entropy density suffers from “information loss” because it lacks a dependence on the velocity space grid, and so has lost information about how well a distribution function is resolved. Local velocity-space kinetic entropy density recovers this information. We quantify information loss and argue that the considerations needed to minimize it are crucial for instruments designed to measure distribution functions in situ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the radiation energy in the radio signal of extensive air showers as a universal estimator of cosmic-ray energy

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 ± 0.7 (stat) ± 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

47 OTHER INSTRUMENTATION↗

Single-crystal sapphire tubes as economical probes for optical pyrometry in harsh environments

One-end-sealed single-crystal sapphire tubes are presented as a simple, robust, and economical alternative for bulky lightpipe probes. Thermal radiation from a blackbody cavity created at the inner surface of the sealed end is gathered by a simple lens-based collecting system and transmitted via optical fiber to the remote detection unit. Simplicity and applicability of the concept are demonstrated by the combination of commercially available sapphire tubes with a common optical pyrometer. Radiation thermometers with sapphire tubes as invasive probes can be useful for applications requiring immunity to electromagnetic interference, resistance to harsh environments, simple replacement in the case of failure, and enhanced mechanical firmness, enabling wider range probe positioning inside the medium of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Electromagnetic Scattering From a Dihedral Cut Into a Sphere Using Vector Spherical Harmonics

Proper calibration or verification of the calibration of fully - polarimetric radar requires more than a simple specular target, such as a conducting sphere or corner reflector. The dihedral reflector is a useful radar - scattering target for calibrating the polarization response of a radar system, because it possesses the ability to change the direction of the scattered electric - field vector in a special way, while a sphere or trihedral target does not. However, the scattered electromagnetic field of a sphere can be computed with arbitrary precision using the well - known Mie series, which is obtained by expanding the scattered field as a series of vector spherical harmonics. In contrast, the computation of the scattered electromagnetic field of dihedral reflectors typically relies on numerical methods or various approximate solutions of Maxwell's equations. Precision calibration of wide - bandwidth polarimetric radar has not been adequately achieved for some applications using this approach. This report describes a method for computing the scattered electromagnetic field of a specially shaped dihedral, derived through the application of a series expansion in vector spherical harmonics, with the goal of achieving the same precision that is available for the sphere.

47 OTHER INSTRUMENTATION↗