Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTENING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The Unique Role of Anchoring Penta-coordinated Al3+ Sites in the Sintering of γ Al2O3-supported Pt Catalysts

In this communication, we report on the specific role of the Alp sites in Pt sintering over γ-Al2O3 support. On the basis of HR-STEM and EXAFS results that showed a bimodal distribution of Pt clusters on γ-Al2O3 during Pt sintering under high-temperature calcination conditions, high-level density functional theory (DFT) calculations were performed to investigate the interactions of atomic Pt and PtO on γ-Al2O3 at different coverages. In agreement with experimental observations, DFT calculations indicate that the sintering processes are both thermodynamically and kinetically hindered by strong interactions of atomic Pt and PtO with the Alp sites on the γ-Al2O3 support. Therefore, increasing the quantity of (100) facets of γ-Al2O3, on which the Alp sites reside, may provide a way to control the sintering of γ-Al2O3-supported Pt catalysts. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fatigue strength of a single lap joint SPR-bonded

In the last years, hybrid joints, meaning with this the joints which consist in combining a traditional mechanical joint to a layer of adhesive, are gradually attracting the attention of various sectors of the construction of vehicles and transportation industries, for their better performance compared to just mechanical joints (self-piercing riveting SPR, riveting, and so on) or just to bonded joints.The paper investigates the fatigue behavior of a single lap joint self-piercing riveted (SPR) and bonded throughout fatigue tests. The considered geometric configuration allowed the use of two rivets placed longitudinally; an epoxy resin was used as adhesive. In the first part of the work static characterization of the joints was carried out through tensile tests. Then fatigue tests were made with the application of different levels of load. The fatigue curves were also obtained at the varying the distance between the two rivets in order to better assess the joint strength for a given length of overlap.

36 MATERIALS SCIENCE↗

Mechanical joining with self piercing solid-rivets at elevated tool velocities

In the present paper the influence of a higher setting velocity in the joining process of self piercing solid-rivets is shown. In the conventional process tool velocities well below 1 m/s are common. The present research results show the potential of increasing them in the range of about 5 m/s. The results are especially relevant for joining high-strength steels. These steel sheets often cause problems in the process of riveting mixed materials, e. g. aluminium-steel compound. The high strength of the steel sometimes leads to undesirable material flow in the joining process or unwanted burr development. These effects, which are described in detail in the article, can be reduced significantly for the investigated cases by the use of higher tool velocities. Using a high speed camera and a load cell, a test setup based on a drop tower was realized. It was used to time the force signals and the motion profile of the high speed riveting process. The results of the force analysis show an oscillating force progression. Within a numerical research the principal effects influencing the results of the riveting process can be shown. It was found that the pulse-like force transmission between riveting machine and punch, results in various vibrations especially of long and thin tool parts. Hence the rivet penetrates the sheet metal with non-uniform velocities. As a result the early indentation of die into the lower sheet metal at the beginning of the process is reduced, so that the final process step provides a sufficient material flow into the circular rivet groove. A strain-rate dependent process model with elastic tool properties and consideration of inertia effects is presented.

36 MATERIALS SCIENCE↗

Identification and Structural Characterization of the ALIX-Binding Late Domains of Simian Immunodeficiency Virus SIV mac239 and SIV agmTan-1

Retroviral Gag proteins contain short late-domain motifs that recruit cellular ESCRT pathway proteins to facilitate virus budding. ALIX-binding late domains often contain the core consensus sequence YPX{sub n}L (where X{sub n} can vary in sequence and length). However, some simian immunodeficiency virus (SIV) Gag proteins lack this consensus sequence, yet still bind ALIX. We mapped divergent, ALIX-binding late domains within the p6{sup Gag} proteins of SIV{sub MAC239} ({sub 40}SREK{und P}YKE{und VT}ED{und L}LHLNSLF{sub 59}) and SIV{sub agmTan-1} ({sub 24}AAG{und A}YDP{und AR}KL{und L}EQYAKK{sub 41}). Crystal structures revealed that anchoring tyrosines (in lightface) and nearby hydrophobic residues (underlined) contact the ALIX V domain, revealing how lentiviruses employ a diverse family of late-domain sequences to bind ALIX and promote virus budding.

59 BASIC BIOLOGICAL SCIENCES↗

Improving Rivet Performance by Ultrasonic Shock Treatment

The reliability of rivets is improved if the residual compressive stress is uniformly distributed over the joint thickness, with simultaneous decrease in the riveting forces required. The possibility of improving rivet performance by ultrasonic shock treatment is considered. On that basis, a riveting method is proposed. Its effectiveness is analyzed.

42 ENGINEERING↗

Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor

The bolt tensile and joint separation loads are directly influenced by the locations at which the external loads enter the clamped members of a preloaded bolted joint (PBJ) and the associated load-paths through the joint. This physical load introduction mechanism affecting the bolt tensile loading is typically represented in the bolt tensile load equation, in part, by a load introduction factor (LIF), which was shown by H.M. Lee of Marshall Spaceflight Center to be a natural product of the bolt tensile load equation using a linear spring stiffness model. This LIF, being a function of load-path stiffness, has subsequently been denoted as the stiffness-based LIF (SBLIF), providing a framework to calculate the LIF using whatever load-path stiffness approximations are appropriate. Expanding upon the work of Lee, it is shown that the SBLIF and the joint stiffness factor are functions of the stiffnesses of the same load-paths and regions within a PBJ, and thus they should not be treated as independent variables. Mathematical expressions for the SBLIF are presented. Comparisons are shown between the analytically calculated SBLIF, the analytically calculated geometric LIF (GLIF), which is a simple clamped-member thickness ratio, the experimentally derived LIF, and the LIF determined by finite element analysis (FEA). Using experiment and FEA as a benchmark, the SBLIF, using traditional load-path stiffness approximations, enables a more accurate prediction of bolt tensile loading than the GLIF, although it can be unconservative near joint separation. The GLIF generally attributes more of the externally applied tensile load to the bolt than does the SBLIF, potentially resulting in heavier and/or more costly bolted joints. Mathematical relationships between the SBLIF and the GLIF are developed. Supplemental material is provided in the appendixes where the historical practice of using the joint compressive stiffness in place of the joint tensile stiffness is evaluated. The appendixes include step-by-step examples demonstrating the calculation of the SBLIF using traditional stiffness approximations and conclude with the development of the joint diagram in terms of the SBLIF, culminating into formulas for the key features of a joint diagram, which is useful for programming.

Load Path↗

Structures of Domains I and IV from YbbR are Representative of a Widely Distributed Protein Family

YbbR domains are widespread throughout Eubacteria and are expressed as monomeric units, linked in tandem repeats or cotranslated with other domains. Although the precise role of these domains remains undefined, the location of the multiple YbbR domain-encoding ybbR gene in the Bacillus subtilis glmM operon and its previous identification as a substrate for a surfactin-type phosphopantetheinyl transferase suggests a role in cell growth, division, and virulence. To further characterize the YbbR domains, structures of two of the four domains (I and IV) from the YbbR-like protein of Desulfitobacterium hafniense Y51 were solved by solution nuclear magnetic resonance and X-ray crystallography. The structures show the domains to have nearly identical topologies despite a low amino acid identity (23%). The topology is dominated by {beta}-strands, roughly following a 'figure 8' pattern with some strands coiling around the domain perimeter and others crossing the center. A similar topology is found in the C-terminal domain of two stress-responsive bacterial ribosomal proteins, TL5 and L25. Based on these models, a structurally guided amino acid alignment identifies features of the YbbR domains that are not evident from naive amino acid sequence alignments. A structurally conserved cis-proline (cis-Pro) residue was identified in both domains, though the local structure in the immediate vicinities surrounding this residue differed between the two models. The conservation and location of this cis-Pro, plus anchoring Val residues, suggest this motif may be significant to protein function.

59 BASIC BIOLOGICAL SCIENCES↗

Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thoracic Aortic Stent-Graft Placement for Safe Removal of a Malpositioned Pedicle Screw

We describe a case of percutaneous placement of a thoracic aortic stent-graft for safe removal of a malpositioned pedicle screw in a 52-year-old man. The patient had undergone posterior thoracic spinal instrumentation for pyogenic spondylitis and spinal deformity 8 months previously. Follow-up CT images showed a malpositioned pedicle screw which was abutting the thoracic aorta at the T5 level. After percutaneous stent-graft placement, the malpositioned pedicle screw was safely and successfully removed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advantages and Disadvantages of the Amplatzer Vascular Plug IV in Visceral Embolization: Report of 50 Placements

Purpose: We describe our initial clinical experience in artificial embolization with the Amplatzer Vascular Plug IV (VP IV), a further development of the Vascular Plug family already in routine use. Methods: Results from 50 embolization procedures conducted with the VP IV in 44 patients are summarized. Results: All 50 embolizations were successful, although two required the technique to be modified because of problems with jamming of the screw thread and thus with disconnection of the plug. This was associated with large branching angles. Conclusions: With experience, the VP IV can be used safely and effectively, and it expands the spectrum of possible embolizations in interventional radiology. Its greatest disadvantage is its relatively poor positional controllability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Posterior Wall Capture and Femoral Artery Stenosis Following Use of StarClose Closing Device: Diagnosis and Therapy

A case of femoral artery obstruction following application of a StarClose type arterial puncture closing device (APCD) is presented. Ultrasonographic and angiographic imaging of this complication was obtained. The posterior wall of the vessel was accidentally caught in the anchoring element of the nitinol clip. This complication was successfully resolved by endovascular treatment and the implantation of a stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural basis for executioner caspase recognition of P5 position in substrates

Caspase-3, -6 and -7 cleave many proteins at specific sites to induce apoptosis. Their recognition of the P5 position in substrates has been investigated by kinetics, modeling and crystallography. Caspase-3 and -6 recognize P5 in pentapeptides as shown by enzyme activity data and interactions observed in the crystal structure of caspase-3/LDESD and in a model for caspase-6. In caspase-3 the P5 main-chain was anchored by interactions with Ser209 in loop-3 and the P5 Leu side-chain interacted with Phe250 and Phe252 in loop-4 consistent with 50% increased hydrolysis of LDEVD relative to DEVD. Caspase-6 formed similar interactions and showed a preference for polar P5 in QDEVD likely due to interactions with polar Lys265 and hydrophobic Phe263 in loop-4. Caspase-7 exhibited no preference for P5 residue in agreement with the absence of P5 interactions in the caspase-7/LDESD crystal structure. Initiator caspase-8, with Pro in the P5-anchoring position and no loop-4, had only 20% activity on tested pentapeptides relative to DEVD. Therefore, caspases-3 and -6 bind P5 using critical loop-3 anchoring Ser/Thr and loop-4 side-chain interactions, while caspase-7 and -8 lack P5-binding residues.

36 MATERIALS SCIENCE↗

Friction Hydro-Pillar Processing of a High Carbon Steel: Joint Structure and Properties

A coupled experimental and theoretical study is reported here on friction hydro-pillar processing of AISI 4140 steel, which is a novel solid-state joining technique to repair and fill crack holes in thick-walled components by an external stud. The stud is rotated and forced to fill a crack hole by plastic flow. During the process, frictional heating occurs along the interface of the stud and the wall of crack hole leading to thermal softening of the stud that eases its plastic deformation. The effect of the stud force, its rotational speed and the total processing time on the rate of heat generation and resulting transient temperature field is therefore examined to correlate the processing variables with the joint structure and properties in a systematic and quantitative manner, which is currently scarce in the published literature. The results show that a gentler stud force rate and greater processing time can promote proper filling of the crack hole and facilitate a defect-free joint between the stud and original component.

36 MATERIALS SCIENCE↗

Simulation Analysis and Performance Study of CoCrMo Porous Structure Manufactured by Selective Laser Melting

To fabricate porous implants with improved biocompatibility and mechanical properties that are matched to their application using selective laser melting (SLM), flow within the mold and compressive properties and performance of the porous structures must be comprehensively studied. Parametric modeling was used to build 3D models of octahedron and hexahedron structures. Finite element analysis was used to evaluate the mold flow and compressive properties of the parametric porous structures. A DiMetal-100 SLM molding apparatus was used to manufacture the porous structures and the results evaluated by light microscopy. The results showed that parametric modeling can produce robust models. Square structures caused higher blood cell adhesion than cylindrical structures. “Vortex” flow in square structures resulted in chaotic distribution of blood elements, whereas they were mostly distributed around the connecting parts in the cylindrical structures. No significant difference in elastic moduli or compressive strength was observed in square and cylindrical porous structures of identical characteristics. Hexahedron, square and cylindrical porous structures had the same stress–strain properties. For octahedron porous structures, cylindrical structures had higher stress–strain properties. Using these modeling and molding results, an important basis for designing and the direct manufacture of fixed biological implants is provided.

36 MATERIALS SCIENCE↗

Raman Strain Sensing and Interfacial Stress Transfer of Hierarchical CNT-Coated Carbon Fibers

Hierarchical reinforcements of carbon fibers (CFs) coated with carbon nanotubes (CNTs) were produced via two different methodologies, namely chemical vapor deposition (CVD) and wet chemical treatment. These advanced smart structural materials are possible candidates for inherent strain sensing and improved interfacial properties when incorporated in the volume of structural fiber-reinforced polymer composites. The morphology and wetting properties of the hierarchical CFs were evaluated via SEM and contact angle measurements. Enhanced values in the strain-induced Raman sensing ability of the hierarchical reinforcement produced via CVD in comparison with the uncoated fibers were measured at single fiber level. The residual stress transfer profiles of both the hierarchical and the uncoated carbon fibers were also evaluated using the Raman spectroscopy in order to evaluate the phase interaction in the hierarchical structure. Compressive residual stresses in the order of 1.5 GPa were found to act on the CF surfaces, while tensile residual stresses were measured for both the CNT-coated systems. The effects of the preparation process of the CNT coatings on the residual stress profiles were also prominent, with the CVD-grown coatings resulting in higher tensile residual stresses, 1.76 GPa instead of 1.22 GPa for the coatings produced via wet chemical treatment. The change in the residual stress profiles established the interaction between the CFs and the CNTs via an anchoring mechanism which significantly altered the stress field at the vicinity of the interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Determination of Residual Stress in Quenched and Cold-Compressed 7050 Aluminum Alloy T-Section Forgings by the Contour Method and Neutron Diffraction

Residual stresses were determined through the thickness of quenched and quenched followed by cold compression 7050 aluminum alloy T-section forgings using the contour method and neutron diffraction. 7050 T-section forgings are used for the manufacture of the connecting joints of wing and fuselage. Inevitably high residual stresses are introduced during the quenching process of 7050 T-section forgings, which could be reduced by cold compression to overcome the effect of residual stress on machining deformation. The longitudinal residual stresses obtained by the two techniques achieved good agreement in both trend and magnitude in both the quenched and quenched followed by cold compression 7050 T-section forgings. The stress-free lattice spacing of Al(311), the Bragg reflection used for the neutron measurements, was obtained from a 5-mm slice using the plane-stress condition, and its variation through the thickness is insignificant in both the quenched specimen and quenched followed by cold compression specimen. A comparison of the residual stresses in the quenched specimen and quenched followed by cold compression specimen showed significant changes in range of residual stresses from (− 304, 262 MPa) induced by quenching process to (− 125, 142 MPa) due to 3% cold compression. The percentage reduction in residual stress in the quenched specimen due to 3% cold compression was (46, 59%).

36 MATERIALS SCIENCE↗