Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Differences in elasticity of vinculin-deficient F9 cells measured by magnetometry and atomic force microscopy

We have investigated a mouse F9 embryonic carcinoma cell line, in which both vinculin genes were inactivated by homologous recombination, that exhibits defective adhesion and spreading [Coll et al. (1995) Proc. Natl. Acad. Sci. USA 92, 9161-9165]. Using a magnetometer and RGD-coated magnetic microbeads, we measured the local effect of loss and replacement of vinculin on mechanical force transfer across integrins. Vinculin-deficient F9Vin(-/-) cells showed a 21% difference in relative stiffness compared to wild-type cells. This was restored to near wild-type levels after transfection and constitutive expression of increasing amounts of vinculin into F9Vin(-/-) cells. In contrast, the transfection of vinculin constructs deficient in amino acids 1-288 (containing the talin- and alpha-actinin-binding site) or substituting tyrosine for phenylalanine (phosphorylation site, amino acid 822) in F9Vin(-/-) cells resulted in partial restoration of stiffness. Using atomic force microscopy to map the relative elasticity of entire F9 cells by 128 x 128 (n = 16,384) force scans, we observed a correlation with magnetometer measurements. These findings suggest that vinculin may promote cell adhesions and spreading by stabilizing focal adhesions and transferring mechanical stresses that drive cytoskeletal remodeling, thereby affecting the elastic properties of the cell.

Non-NASA Center↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

(abstract) Transmission Electron Microscopy of Al(sub x)Ga(sub 1-x)N/SiC Multilayer Structures

The potential of wide-band-gap III-V nitrides as solar-blind ultraviolet sensors and light emitters has prompted an increasing amount of work recently, including the fabrication of the first UV sensors from as-deposited single crystal GaN. We have used high resolution transmission electron microscopy (TEM) to study the microstructure of two novel developments of wide-band-gap III-V nitrides: the growth of ultra-short period GaN/AlN super lattices (digital alloys); and the incorporation of SiC layers into Al(sub x)Ga(sub 1-x)N structures. By varying the relative periods in a GaN/AlN superlattice, it should be possible to tailor the band gap of the composite to lie between the elemental values of 365 nm for GaN and 200 nm for AlN. The group IV semiconductor, SiC, has a close lattice match (< 3%) to Al(sub x)Ga(sub 1-x)N for growth on the basal plane. Demonstration of epitaxial growth for Al(sub x)Ga(sub 1-x)N/SiC multilayers could enable an extension of direct band-gap material towards the visible.

microscopy GaN AlN semiconductor SiC↗

Light Microscopy Module (LMM)-Emulator

The Light Microscopy Module (LMM) is a microscope facility developed at Glenn Research Center (GRC) that provides researchers with powerful imaging capability onboard the International Space Station (ISS). LMM has the ability to have its hardware recongured on-orbit to accommodate a wide variety of investigations, with the capability of remotely acquiring and downloading digital images across multiple levels of magnication.

LMM Emulator↗

Light Microscopy Module: International Space Station Premier Automated Microscope

The Light Microscopy Module (LMM) was launched to the International Space Station (ISS) in 2009 and began hardware operations in 2010. It continues to support Physical and Biological scientific research on ISS. During 2016, if all goes as planned, three experiments will be completed: [1] Advanced Colloids Experiments with Heated base-2 (ACE-H2) and [2] Advanced Colloids Experiments with Temperature control (ACE-T1). Preliminary results, along with an overview of present and future LMM capabilities will be presented; this includes details on the planned data imaging processing and storage system, along with the confocal upgrade to the core microscope. [1] a consortium of universities from the State of Kentucky working through the Experimental Program to Stimulate Competitive Research (EPSCoR): Stuart Williams, Gerold Willing, Hemali Rathnayake, et al. and [2] from Chungnam National University, Daejeon, S. Korea: Chang-Soo Lee, et al.

Microgravity Biology Research↗

Using the Light Microscopy Module (LMM) on the International Space Station (ISS), The Advanced Colloids Experiment (ACE) and MacroMolecular Biophysics (MMB)

The Light Microscopy Module (LMM) was launched to the International Space Station (ISS) in 2009 and began science operations in 2010. It continues to support Physical and Biological scientific research on ISS. During 2016, if all goes as planned, three experiments will be completed: [1] Advanced Colloids Experiments with Heated base-2 (ACE-H2) and [2] Advanced Colloids Experiments with Temperature control (ACE-T1). Preliminary results, along with an overview of present and future LMM capabilities will be presented; this includes details on the planned data imaging processing and storage system, along with the confocal upgrade to the core microscope. [1] a consortium of universities from the State of Kentucky working through the Experimental Program to Stimulate Competitive Research (EPSCoR): Stuart Williams, Gerold Willing, Hemali Rathnayake, et al. and [2] from Chungnam National University, Daejeon, S. Korea: Chang-Soo Lee, et al.

Microgravity Biology Research↗

The Light Microscopy Module A Facility Overview-History and Science

We will share a brief history and provide a science overview of the many accomplishments of the Light Microscopy Module (LMM), a microscope that has been operating in the microgravity environment of the International Space Station (ISS) since 2010. It will be removed in October 2021. It was initially outfitted for the Constrained Vapor Bubble – Wickless Heat Pipe experiment. It was later reconfigured and upgraded many times to support a broad portfolio of Physical science and Biological experiments including: Complex Fluids, Colloids, Macro-Molecular Biophysics, Protein Crystals, and Plant Biology. The LMM has enabled many significant studies and discoveries and has seen its fair share of pleasant surprises. These include recording order arising out of disorder, e.g., systems of colloids that were glasses on Earth crystallizing to form large defect-free crystals, nematic ordering of elliptical colloids, and colloidal-polymer systems crystallizing. The LMM science teams have also seen how to improve product stabilizers once the effects of sedimentation on Earth were removed; they were able to see which tagged genes express in plants when gravity is removed, telling them which genes are essential for growing plants in space; they’ve tested protein crystal growth models; checked models for creating bijel electrodes that turn batteries into fast-charging supercapacitors; tested many forms of colloidal self-assembly: including those using depletion attraction, magnetic fields, and critical Casimir forces; they’ve observed explosive bubble nucleation in a wickless heat pipe, and much more. This work has been supported by the NASA Biological and Physical Sciences (BPS) Division and the ISS Program Office, Johnson Space Center Code OZ and Code OB, the Center for the Advancement of Science in Space (CASIS) / ISS National Lab, EPSCoR, and ISS international partners from ESA – the Netherlands and Italy, CSA, JAXA and S. Korea, and by Space Act Agreements with Procter and Gamble (P&G).

Colloids↗

Comparison of In-situ Near Infrared Melt Pool Imagery to Optical Microscopy Measurements

Additive manufacturing (AM) is a rapidly growing technology. An area of major importance is the integrity and repeatability of AM parts. The goal is to reduce obstacles to certify AM built parts to allow for use in critical aerospace applications. In-situ nondestructive evaluation sensors can be used for build assessment and can potentially play a key role in certifying AM parts. For example, melt pool features are understood to have a strong correlation to microstructural defects and the use of a near infrared (NIR) camera can be used to record the melt pool, cooling areas, and temperature gradients during the build. This work explores the use of a low cost NIR camera to obtain single line track imagery of the Ti-6Al-4V melt pools for various processing parameters. The NIR camera is radiometrically calibrated and configured in-line with the laser source to obtain high resolution imagery of the melt pool shape and dynamics. The challenge to measure melt pool shapes is to identify the transition points between the metal solid to liquid phase. Factors for melt pool measurements such as thermal camera pixel resolution, surface emissivity, and blurring due to the laser beam movement are discussed. Lastly, the melt pool imagery are compared to optical microscopy measurements for validation.

additive manufacturing↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Characterizing Dislocation Defects in Dark Field X-ray Microscopy Images of Bulk Aluminum

Material defects play a large role in material response under shock loading, yet the process of how these defects initiate, propagate, and annihilate is not well understood. Using a newly developed diagnostic, dark field X-ray microscopy (DFXM), we can now visualize the behavior of dislocation defects in materials at the mesoscale under varying conditions. Using data from the European Synchrotron Radiation Facility, we apply a variety of image processing techniques to capture relevant features to locate and characterize size and orientation of dislocation defects in bulk aluminum DFXM images. Beyond simple visualization, this analysis drives statistical characterization of the defects and their dynamic response to further improve the relevant physics models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining Bioethanol-Producing Ultrastructures with Electron Microscopy and Molecular Dynamics

A longstanding goal in the biofuel sector is to increase the efficiency of the circularization of the use of materials (1). One such instance is the degradation of plant material, such as cellulose, and converting it to biofuel via bacterial digestion (2). The bifunctional aldehyde-alcohol dehydrogenase (AdhE) from the anaerobic thermophile C. thermocellum seems to be vital for the production and cellular tolerance of bioethanol; however, it lacks the efficiency to produce ethanol at industry standards (3). Therefore, to understand how C. thermocellum AdhE functions, we used cryo-electron microscopy (cryo-EM) to obtain a 3.2 A structure of the AdhE complex. When compared to previously published structures from E. coli (4-6), we identified potential regions that control the native conformation of the ultrastructure, as well as located channels that isolate the intermediate aldehyde from the cellular milieu. This high-resolution structure, in combination with molecular dynamics simulations, provides insight into one example of substrate channeling and establishes a basis for future mutagenesis studies.

AdhE↗

Leveraging Super High Optical Resolution Microscopy to Probe the Interaction Zone Between Clostridium thermocellum and Biomass

This poster, part of the Pacific Northwest National Laboratory-sponsored Integration 2020: Visualizing the Proteome virtual conference, discusses super high optical resolution microscopy to probe the interaction zone between Clostritium thermocellum and biomass. Clostridium thermocellum is one of the most efficient microorganisms for the deconstruction of biomass. To achieve this high level of cellulolytic activity, C. thermocellum uses large multienzyme complexes known as cellulosomes to sugars in 4-5 break down polysaccharides found in plant cell walls. The attachment of bacterial switchgrass 70% cells to the nearby substrate via the cellulosome has been hypothesized to be the reason for this high efficiency. The region lying between the cell and the substrate has shown great variation and dynamics that are affected by the growth stage of cells and the substrate used for growth.

bacteria↗

Initial results from electron microscopy from AGR 5/6/7 Capsule 1 fuel and

Initial results from electron microscopy from AGR 5/6/7 Capsule 1 fuel and applications of other microanalysis techniques to irradiated TRISO fuel. Includes detail on characterization of particles from AGR 5/6/7 Capsule 1, which include background and motivation, x-ray computed tomography on four particles from compact 1-7-9, SEM/EDS of particles from compacts 1-7-9 and 1-7-4, and Summary. Local thermal conductivity measurement on AGR-2 particles also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗