Search NASA⌕ Search

SEARCH · Search NASA

Results for “References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A reduced chemical kinetic model for IC engine combustion simulations with primary reference fuels

A reduced chemical kinetic mechanism for the oxidation of primary reference fuel (PRF) has been developed and applied to model internal combustion engines. Starting from an existing reduced reaction mechanism for n-heptane oxidation, a new reduced n-heptane mechanism was generated by including an additional five species and their relevant reactions, by updating the reaction rate constants of several reactions pertaining to oxidation of carbon monoxide and hydrogen, and by optimizing reaction rate constants of selected reactions. Using a similar approach, a reduced mechanism for iso-octane oxidation was built and combined with the n-heptane mechanism to form a PRF mechanism. The final version of the PRF mechanism consists of 41 species and 130 reactions. Validation of the present PRF mechanism was performed with measurements from shock tube tests, and HCCI and direct injection engine experiments available in the literature. The results show that the present PRF mechanism gives reliable performance for combustion predictions, as well as computational efficiency improvements for multidimensional CFD simulations. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

Application of the hybrid approach to the benchmark dose of urinary cadmium as the reference level for renal effects in cadmium polluted and non-polluted areas in Japan

Objectives: The aim of this study was to evaluate the reference level of urinary cadmium (Cd) that caused renal effects. An updated hybrid approach was used to estimate the benchmark doses (BMDs) and their 95% lower confidence limits (BMDL) in subjects with a wide range of exposure to Cd. Methods: The total number of subjects was 1509 (650 men and 859 women) in non-polluted areas and 3103 (1397 men and 1706 women) in the environmentally exposed Kakehashi river basin. We measured urinary cadmium (U-Cd) as a marker of long-term exposure, and {beta}2-microglobulin ({beta}2-MG) as a marker of renal effects. The BMD and BMDL that corresponded to an additional risk (BMR) of 5% were calculated with background risk at zero exposure set at 5%. Results: The U-Cd BMDL for {beta}2-MG was 3.5 {mu}g/g creatinine in men and 3.7 {mu}g/g creatinine in women. Conclusions: The BMDL values for a wide range of U-Cd were generally within the range of values measured in non-polluted areas in Japan. This indicated that the hybrid approach is a robust method for different ranges of cadmium exposure. The present results may contribute further to recent discussions on health risk assessment of Cd exposure.

60 APPLIED LIFE SCIENCES↗

A predictive 0-D HCCI combustion model for ethanol, natural gas, gasoline, and primary reference fuel blends

Homogeneous Charge Compression Ignition (HCCI) is a promising advanced combustion concept with high thermal efficiency and low exhaust emissions. This work purposes a computationally-efficient, zero-dimensional (0-D) HCCI combustion model that does not need to solve any differential equations. To develop the burn rate correlations, experimental HCCI data of ethanol, natural gas, E10-gasoline, and Primary Reference Fuel (PRF) blends was collected on a CFR engine. The burn rate model is built based on the individual cycle mass fraction burned (MFB) curves calculated from the experimental data. CA0 can be predicted from an ignition delay correlation. Once CA0 is known, CA50 and CA90 can be predicted based on CA0 and the charge-mass equivalence ratio Φ'. Then, with CA0, 50 and 90 known, a Wiebe function can be constructed to represent the MFB curve and burn rate. For PRF blends, low-temperature and high-temperature heat releases (LTHR and HTHR) are modeled by two Wiebe functions with Φ' and PRF number dependence. The fitted model has high accuracy compared to the experimental data with R 2 values generally greater than 0.97. Finally, various ignition delay correlations from the literature are also tested against the experimentally collected data and some modifications to the correlations are suggested.

42 ENGINEERING↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography

We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with the expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.

Atom Probe Tomography↗

Insights from incorporating reference electrodes in symmetric lithium-ion cells with layered oxide or graphite electrodes

Symmetric cells provide complementary means to probe electrochemical processes in lithium-ion batteries. Here, positive and negative electrodes harvested from conventional oxide/graphite cells are cross-paired, and the assembled reference-electrode-bearing symmetric cells are cycled/aged. For graphite symmetric cells, the electrode potentials and impedances remain nearly constant during calendar aging and the parasitic currents are typically small. However, at higher cell voltages when the “positive” graphite potential exceeds 1.0 V vs. Li/Li + , the capacity loss is higher, indicating that even a mild (but prolonged) overdischarge can damage the SEI. For the layered-oxide symmetric cells there are strong parasitic currents and a persistent slide of the electrode potential over time during calendar aging. Significant cell impedance rise, especially at higher hold voltages, is also observed. Curiously, the impedance rise in the “negative” oxide electrode, which experiences potentials below 4.0 V vs. Li/Li + , is greater than in the “positive” oxide electrode that experiences much higher potentials. We postulate that electrolyte oxidation is responsible for the behavior of these oxide symmetric cells, as it supplies electrons (that bind more Li + into the cathode, causing the potential slide) and protons (that contribute to impedance rise). Furthermore, these insights can guide the development of future lithium-ion cell chemistries.

25 ENERGY STORAGE↗

Electrophoretic deposition for improved trace element homogeneity in silica reference materials

Spatially-resolved analysis requires homogeneous reference materials (RMs) to make reliable quantitative measurements. Here we previously developed an electrophoretic deposition (EPD) method for fabrication of glassy microanalytical RMs with superior platinum-group element homogeneity **[1], and now include further dopants. For 39 trace elements, we analyzed dopant homogeneity in sintered silica (SiO 2 ) samples consolidated either mechanically by die-pressing (DP) or by EPD. A set of EPD and DP samples was made from each of two nanoparticle feedstocks produced by variations of the Stöber process **[2]. Spatially-resolved dopant distribution was characterized in all samples by laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS). In both sample sets, homogeneity of most trace elements was substantially improved by EPD relative to their DP counterpart.

36 MATERIALS SCIENCE↗

Development of a Reference Database for Beta-Delayed Neutron Emission

Beta-delayed neutron emission is important for nuclear structure and astrophysics as well as for reactor applications. Significant advances in nuclear experimental techniques in the past two decades have led to a wealth of new measurements that remain to be incorporated in the databases. In this work, we report on a coordinated effort to compile and evaluate all the available β-delayed neutron emission data. The different measurement techniques have been assessed and the data have been compared with semi-microscopic and microscopic-macroscopic models. The new microscopic database has been tested against aggregate total delayed neutron yields, time-dependent group parameters in 6-and 8-group re-presentation, and aggregate delayed neutron spectra. New recommendations of macroscopic delayed-neutron data for fissile materials of interest to applications are also presented. The new Reference Database for Beta-Delayed Neutron Emission Data is available online.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of the AC orbit bump method of local kick factor measurement using reference bunches

Here we have improved the AC orbit bump technique of local kick factor measurement. This technique, developed at NSLS-II a few years ago, is based on local sine-wave excitation of the electron beam by four fast correctors adjacent to the impedance location. By implementing reference bunches and the time gate function of beam position monitors, we are now able to measure the AC orbits of bunches with different intensities simultaneously. This improvement allows us to obtain the impedance-driven orbit distortion in a single measurement, significantly improving the measurement accuracy and reducing the measurement time.

36 MATERIALS SCIENCE↗

The IAEA coordinated research programme on HTGR uncertainty analysis: Phase I status and Ex. I-1 prismatic reference results

The quantification of uncertainties in design and safety analysis of reactors is today not only broadly accepted, but in many cases became the preferred way to replace traditional conservative analysis for safety and licensing analysis. The use of a more fundamental methodology is also consistent with the reliable high fidelity physics models and robust, efficient, and accurate codes available today. To facilitate uncertainty analysis applications a comprehensive approach and methodology must be developed and applied, in contrast to the historical approach where sensitivity analysis were performed and uncertainties then determined by a simplified statistical combination of a few important input parameters. New methodologies are currently under development in the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity. High Temperature Gas-cooled Reactor (HTGR) designs require specific treatment of the double heterogeneous fuel design and large graphite quantities at high temperatures. The IAEA has therefore launched a Coordinated Research Project (CRP) on HTGR Uncertainty Analysis in Modelling (UAM) in 2013 to study uncertainty propagation specifically in the HTGR analysis chain. Two benchmark problems are defined, with the prismatic design represented by the General Atomics (GA) MHTGR-350 and a 250 MW modular pebble bed design similar to the Chinese HTR-PM. Work has started on the first phase and the current CRP status is reported in the paper. A comparison of the Serpent and SCALE/KENO-VI reference Monte Carlo results for Ex. I-1 of the MHTGR-350 design is also included. It was observed that the SCALE/KENO-VI Continuous Energy (CE) k ∞ values were 395 pcm (Ex. I-1a) to 803 pcm (Ex. I-1b) higher than the respective Serpent lattice calculations, and that within the set of the SCALE results, the KENO-VI 238 Multi-Group (MG) k ∞ values were up to 800 pcm lower than the KENO-VI CE values. The use of the latest ENDF-B-VII.1 cross section library in Serpent lead to ~180 pcm lower k ∞ values compared to the older ENDF-B-VII.0 dataset, caused by the modified graphite neutron capture cross section. Furthermore, the fourth beta release of SCALE 6.2 likewise produced lower CE k∞ values when compared to SCALE 6.1, and the improved performance of the new 252-group library available in SCALE 6.2 is especially noteworthy. A SCALE/TSUNAMI uncertainty analysis of the Hot Full Power variant for Ex. I-1a furthermore concluded that the 238 U(n,γ) (capture) and 235 U(View the MathML source) cross-section covariance matrices contributed the most to the total k ∞ uncertainty of 0.58%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Comment on “STM study of the (111) and (100) surfaces of PdAg, Surf. Sci. 417 (1998) 292–300" and references therein

Investigation of isolated, single atoms on the surfaces of alloys is of great interest in the field of heterogeneous catalysis. Prior studies by Nieuwenhuys, etal. [Surf. Sci. 417 (1998) 292–300 and references therein] showed that annealing the (111) surface of a PdAg bulk alloy yielded a surface with ~5% Pd, predominantly in the form of single atoms, rendering it an ideal model for investigating the reactivity of single Pd atoms. Herein, new evidence is reported that establishes the bulk composition of the PdAg(111) alloy studied previously is 67 % Ag and 33 % Pd, whereas it was reported to be 33 % Ag and 67 % Pd in the prior studies. Furthermore, the bulk composition of a crystal derived from the same PdAg alloy boule used previously was determined using energy-dispersive X-ray spectroscopy (EDS)—a bulk sensitive technique. Surface-sensitive measurements, including X-ray photoelectron spectroscopy, were also performed and are in good agreement with the prior studies by Nieuwenhuys, etal.

36 MATERIALS SCIENCE↗

Crystal structure and synchrotron X-ray powder reference pattern for the porous pillared cyanonickelate, Ni(3-amino-4,4′-bipyridine)[Ni(CN) 4 ]

The structure of Ni(3-amino-4,4′-bipyridine)[Ni(CN) 4 ] (or known as Ni-BpyNH 2 ) in powder form was determined using synchrotron X-ray diffraction and refined using the Rietveld refinement technique (R = 8.8%). The orthorhombic (Cmca) cell parameters were determined to be a = 14.7218(3) Å, b = 22.6615(3) Å, c = 12.3833(3) Å, V = 4131.29(9) Å 3 , and Z = 8. Ni-BpyNH 2 forms a 3-D network, with a 2-D Ni(CN) 4 net connecting to each other via the BpyNH 2 ligands. Further, there are two independent Ni sites on the net. The 2-D nets are connected to each other via the bonding of the pyridine “N” atom to Ni2. The Ni2 site is of six-fold coordination to N with relatively long Ni2–N distances (average of 2.118 Å) as compared to the four-fold coordinated Ni1–C distances (average of 1.850 Å). The Ni(CN) 4 net is arranged in a wave-like fashion. The functional group, –NH 2 , is disordered and was found to be in the m-position relative to the N atom of the pyridine ring. Instead of having a unique position, N has ¼ site occupancy in each of the four m-positions. The powder reference diffraction pattern for Ni-BpyNH 2 was prepared and submitted to the Powder Diffraction File (PDF) at the International Centre of Diffraction Data (ICDD).

36 MATERIALS SCIENCE↗

Toward Machine Learning-Driven Mass Spectrometric Identification of Trichothecenes in the Absence of Standard Reference Materials

While a significant body of work exists on the detection of commonly known trichothecene toxins, biological, environmental, and other transformational processes can generate many under-characterized and unknown modified trichothecenes. Lacking both analytical reference standards and associated mass spectral databases, identification of these modified compounds reflects both a challenge and a critical gap from forensic and public health perspectives. Here we report here the application of machine learning (ML) techniques toward identification of discriminative fragment ions from mass spectrometric data that can be exploited to detect evidence of type A and B trichothecenes. The goal of this work is to establish a new method for the identification of unknown, though structurally similar trichothecenes, by leveraging objective ML techniques. Discriminative fragments derived from a series of gradient-boosted machine learners are then used to develop ML-driven precursor ion scan (PIS) methods on a triple quadrupole mass spectrometer (QQQ) for screening of “unknown unknown” trichothecenes. Specifically, we apply the PIS method to a laboratory-synthesized trichothecene, a first step in demonstrating the power of alternative, machine learning-driven mass spectrometric methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗

Comprehensive Chemical Characterization of Hydrocarbons in NIST Standard Reference Material 2779 Gulf of Mexico Crude Oil

Comprehensive chemical information is needed to understand the environmental fate and impact of hydrocarbons released during oil spills. However, chemical information remains incomplete because of the limitations of current analytical techniques and the inherent chemical complexity of crude oils. In this study, gas chromatography (GC)-amenable C 9 -C 33 hydrocarbons were comprehensively characterized from the National Institute of Standards and Technology Standard Reference Material (NIST SRM) 2779 Gulf of Mexico crude oil by GC coupled to vacuum ultraviolet photoionization mass spectrometry (GC/VUV-MS), with a mass balance of 68 ± 22%. This technique overcomes one important limitation faced by traditional GC and even comprehensive 2D gas chromatography (GC×GC): the necessity for individual compounds to be chromatographically resolved from one another in order to be characterized. VUV photoionization minimizes fragmentation of the molecular ions, facilitating the characterization of the observed hydrocarbons as a function of molecular weight (carbon number, N C ), structure (number of double bond equivalents, N DBE ), and mass fraction (mg kg -1 ), which represent important metrics for understanding their fate and environmental impacts. Linear alkanes (8 ± 1%), bran ched alkanes (11 ± 2%), and cycloalkanes (37 ± 12%) dominated the mass with the largest contribution from cycloalkanes containing one or two rings and one or more alkyl side chains (27 ± 9%). Linearity and good agreement with previous work for a subset of >100 components and for the sum of compound classes provided confidence in our measurements and represents the first independent assessment of our analytical approach and calibration methodology. Another crude oil collected from the Marlin platform (35 km northeast of the Macondo well) was shown to be chemically identical within experimental errors to NIST SRM 2779, demonstrating that Marlin crude is an appropriate surrogate oil for researchers conducting laboratory research into impacts of the DeepWater Horizon disaster.

02 PETROLEUM↗

Accelerating Ab Initio Simulation via Nested Monte Carlo and Machine Learned Reference Potentials

As a corollary of the rapid advances in computing, ab initio simulation is playing an increasingly important role in modeling materials at the atomic scale. Two strategies are possible, ab initio Monte Carlo (AIMC) and molecular dynamics (AIMD) simulation. The former benefits from exact sampling from the correct thermodynamic distribution, while the latter is typically more efficient with its collective all-atom coordinate updates. In this study, using a relatively simple test model comprised of helium and argon, we show that AIMC can be brought up to, and even above, the performance levels of AIMD via a hybrid nested sampling/machine learning (ML) strategy. Here, ML provides an accurate classical reference potential (up to three-body explicit interactions) that can pilot long collective Monte Carlo moves that are accepted or rejected in toto à la nested Monte Carlo (NMC); this is in contrast to the single move nature of a naive implementation. Our proposed method only requires a small up front expense from evaluating the ab initio energies and forces of (100) random configurations for training. Importantly, our method does not totally rely on the trained, assuredly imperfect, interaction. We show that high performance and exact sampling at the desired level of theory can be realized even when the trained interaction has appreciable differences from the ab initio potential. Remarkably, at the highest levels of performance realized via our approach, a pair of statistically uncorrelated atomic configurations can be generated with (1) ab initio calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗