Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

2D and 3D X-Ray Structural Microscopy Using Submicron-Resolution Laue Microdiffraction

We have developed a scanning, polychromatic x-ray microscopy technique with submicron spatial resolution at the Advanced Photon Source. In this technique, white undulator radiation is focused to submicron diameter using elliptical mirrors. Laue diffraction patterns scattered from the sample are collected with an area detector and then analyzed to obtain the local crystal structure, lattice orientation, and strain tensor. These new microdiffraction capabilities have enabled both 2D and 3D structural studies of materials on mesoscopic length-scales of tenths-to-hundreds of microns. For thin samples such as deposited films, 2D structural maps are obtained by step-scanning the area of interest. For example, 2D x-ray microscopy has been applied in studies of the epitaxial growth of oxide films. For bulk samples, a 3D differential-aperture x-ray microscopy technique has been developed that yields the full diffraction information from each submicron volume element. The capabilities of 3D x-ray microscopy are demonstrated here with measurements of grain orientations and grain boundary motion in polycrystalline aluminum during 3D thermal grain growth. X-ray microscopy provides the needed, direct link between the experimentally measured 3D microstructural evolution and the results of theory and modeling of materials processes on mesoscopic length scales.

36 MATERIALS SCIENCE↗

Imaging mechanism for hyperspectral scanning probe microscopy via Gaussian process modelling

We investigate the ability to reconstruct and derive spatial structure from sparsely sampled 3D piezoresponse force microcopy data, captured using the band-excitation (BE) technique, via Gaussian Process (GP) methods. Even for weakly informative priors, GP methods allow unambiguous determination of the characteristic length scales of the imaging process both in spatial and frequency domains. We further show that BE data set tends to be oversampled in the spatial domains, with ~30% of original data set sufficient for high-quality reconstruction, potentially enabling faster BE imaging. At the same time, reliable reconstruction along the frequency domain requires the resonance peak to be within the measured band. This behavior suggests the optimal strategy for the BE imaging on unknown samples. Finally, we discuss how GP can be used for automated experimentation in SPM, by combining GP regression with non-rectangular scans.

47 OTHER INSTRUMENTATION↗

Combined Application of QEM-SEM and Hard X-ray Microscopy to Determine Mineralogical Associations and Chemcial Speciation of Trace Metals

We describe the application of quantitative evaluation of mineralogy by scanning electron microscopy in combination with techniques commonly available at hard X-ray microprobes to define the mineralogical environment of a bauxite residue core segment with the more specific aim of determining the speciation of trace metals (e.g., Ti, V, Cr, and Mn) within the mineral matrix. Successful trace metal speciation in heterogeneous matrices, such as those encountered in soils or mineral residues, relies on a combination of techniques including spectroscopy, microscopy, diffraction, and wet chemical and physical experiments. Of substantial interest is the ability to define the mineralogy of a sample to infer redox behavior, pH buffering, and mineral-water interfaces that are likely to interact with trace metals through adsorption, coprecipitation, dissolution, or electron transfer reactions. Quantitative evaluation of mineralogy by scanning electron microscopy coupled with micro-focused X-ray diffraction, micro-X-ray fluorescence, and micro-X-ray absorption near edge structure (mXANES) spectroscopy provided detailed insights into the composition of mineral assemblages and their effect on trace metal speciation during this investigation. In the sample investigated, titanium occurs as poorly ordered ilmenite, as rutile, and is substituted in iron oxides. Manganese's spatial correlation to Ti is closely linked to ilmenite, where it appears to substitute for Fe and Ti in the ilmenite structure based on its mXANES signature. Vanadium is associated with ilmenite and goethite but always assumes the +4 oxidation state, whereas chromium is predominantly in the +3 oxidation state and solely associated with iron oxides (goethite and hematite) and appears to substitute for Fe in the goethite structure.

54 ENVIRONMENTAL SCIENCES↗

Molecular self-assembled designing and characterization of TiO2 NPs-CdS QDs-dye composite for photoanode materials

Highlights: • Initially TiO{sub 2} NPs were synthesized by sol-gel method and CdS QDs by one pot synthesis method. • The connectivity between TiO{sub 2} NPs and CdS QDs was well revealed by zeta potential and FTIR techniques. • This binary system was sensitized with N719 dye molecule for better photoanode material. • Ternary TiO{sub 2} NPs-CdS QDs-N719 dye photoanode showed higher conversion efficiency than its binary photoanode devices. - Abstract: Ternary based photoanodes have been prepared by using titanium dioxide (TiO{sub 2}) nanoparticles (NPs), cadmium sulfide (CdS) quantum dots (QDs) and N719 dye. Initially, CdS QDs and TiO{sub 2} NPs were synthesized by one pot synthesis and sol-gel method, respectively. CdS QDs were connected electrostatically to the surfaces of TiO{sub 2} NPs, and after that, this binary hybrid further self-assembled with N719 dye to form the composites. The NPs, QDs and the resultant composites are characterized by using different techniques. The connectivity of these anatase TiO{sub 2} NPs with cubic CdS QDs are confirmed by FTIR; while the broad coverage of these materials is studied through UV–Visible diffuse reflectance spectroscopy (DRS). The surface topology and the cross-sectional morphology of thin films are studied by high resolution transmission electron microscopy (HR-TEM) and field emission scanning electron microscopy (FE-SEM) techniques; while the structural properties of NPs and QDs are studied by X-ray diffractometer (XRD). The synergetic co-sensitization of CdS and N719 dye significantly enhancing the overall power conversion efficiency (η) of TiO{sub 2} up to 2.37% (J{sub sc} = 10.31 mA/cm{sup 2} and V{sub oc} of 550 mV) (100 mW/cm{sup 2}). The J{sub sc}, V{sub oc}, and η values along with Incident photon to current conversion efficiency (IPCE) value of ternary photoelectrode-based solar devices, is almost double to that of either binary TiO{sub 2} NPs-CdS QDs or binary TiO{sub 2} NPs-N719 binary systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-17: Evaluation of Commercially Available Extension Plates for the ACR CT Accreditation Phantom

Purpose: To evaluate the impact of commercially available extension plates on Hounsfield Unit (HU) values in the ACR CT accreditation phantom (Model 464, Gammex Inc., Middleton, Wi). The extension plates are intended to improve water HU values in scanners where the traditional solution involves scanning the phantom with an adjacent water or CTDI phantom. Methods: The Model 464 phantom was scanned on 9 different CT scanners at 8 separate sites representing 16 and 64 slice MDCT technology from four CT manufacturers. The phantom was scanned with and without the extension plates (Gammex 464 EXTPLT-KIT) in helical and axial modes. A water phantom was also scanned to verify water HU calibration. Technique was 120 kV tube potential, 350 mAs, and 210 mm display field of view. Slice thickness and reconstruction algorithm were based on site clinical protocols. The widest available beam collimation was used. Regions of interest were drawn on the HU test objects in Module 1 of the phantom and mean values recorded. Results: For all axial mode scans, water HU values were within limits with or without the extension plates. For two scanners (both Lightspeed VCT, GE Medical Systems, Waukesha WI), axial mode bone HU values were above the specified range both with and without the extension plates though they were closer to the specified range with the plates installed. In helical scan mode, two scanners (both GE Lightspeed VCT) had water HU values above the specified range without the plates installed. With the plates installed, the water HU values were within range for all scanners in all scan modes. Conclusion: Using the plates, the Lightspeed VCT scanners passed the water HU test when scanning in helical mode. The benefit of the extension plates was evident in helical mode scanning with GE scanners using a nominal 4 cm beam. Disclosure: The extension plates evaluated in this work were provided free of charge to the authors. The authors have no other financial interest in Gammex Inc.

60 APPLIED LIFE SCIENCES↗

X-ray nanotomography and focused-ion-beam sectioning for quantitative three-dimensional analysis of nanocomposites

Knowing the relationship between three-dimensional structure and properties is paramount for complete understanding of material behavior. In this work, the internal nanostructure of micrometer-size (~10 µm) composite Ni/Al particles was analyzed using two different approaches. The first technique, synchrotron-based X-ray nanotomography, is a nondestructive method that can attain resolutions of tens of nanometers. The second is a destructive technique with sub-nanometer resolution utilizing scanning electron microscopy combined with an ion beam and `slice and view' analysis, where the sample is repeatedly milled and imaged. The obtained results suggest that both techniques allow for an accurate characterization of the larger-scale structures, while differences exist in the characterization of the smallest features. Using the Monte Carlo method, the effective resolution of the X-ray nanotomography technique was determined to be ~48 nm, while focused-ion-beam sectioning with `slice and view' analysis was ~5 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Mining of Polymer Phase Transitions upon Temperature Changes by Small and Wide-Angle X-ray Scattering Combined with Raman Spectroscopy

The complex physical transformations of polymers upon external thermodynamic changes are related to the molecular length of the polymer and its associated multifaceted energetic balance. The understanding of subtle transitions or multistep phase transformation requires real-time phenomenological studies using a multi-technique approach that covers several length-scales and chemical states. A combination of X-ray scattering techniques with Raman spectroscopy and Differential Scanning Calorimetry was conducted to correlate the structural changes from the conformational chain to the polymer crystal and mesoscale organization. Current research applications and the experimental combination of Raman spectroscopy with simultaneous SAXS/WAXS measurements coupled to a DSC is discussed. In particular, we show that in order to obtain the maximum benefit from simultaneously obtained high-quality data sets from different techniques, one should look beyond traditional analysis techniques and instead apply multivariate analysis. Data mining strategies can be applied to develop methods to control polymer processing in an industrial context. Crystallization studies of a PVDF blend with a fluoroelastomer, known to feature complex phase transitions, were used to validate the combined approach and further analyzed by MVA.

36 MATERIALS SCIENCE↗

Spatial filter based light-sheet laser interference technique for three-dimensional nanolithography

We propose a laser interference technique for the fabrication of 3D nano-structures. This is possible with the introduction of specialized spatial filter in a 2π cylindrical lens system (consists of two opposing cylindrical lens sharing a common geometrical focus). The spatial filter at the back-aperture of a cylindrical lens gives rise to multiple light-sheet patterns. Two such interfering counter-propagating light-sheet pattern result in periodic 3D nano-pillar structure. This technique overcomes the existing slow point-by-point scanning, and has the ability to pattern selectively over a large volume. The proposed technique allows large-scale fabrication of periodic structures. Computational study shows a field-of-view (patterning volume) of approximately 12.2 mm{sup 3} with the pillar-size of 80 nm and inter-pillar separation of 180 nm. Applications are in nano-waveguides, 3D nano-electronics, photonic crystals, and optical microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CT-Guided Radiofrequency Ablation in Patients with Hepatic Metastases from Breast Cancer

The purpose of this study was to evaluate technical success, technique effectiveness, and survival following radiofrequency ablation for breast cancer liver metastases and to determine prognostic factors. Forty-three patients with 111 breast cancer liver metastases underwent CT-guided percutaneous radiofrequency (RF) ablation. Technical success and technique effectiveness was evaluated by performing serial CT scans. We assessed the prognostic value of hormone receptor status, overexpression of human epidermal growth factor receptor 2 (HER2), and presence of extrahepatic tumor spread. Survival rates were calculated using the Kaplan-Meier method. Technical success was achieved in 107 metastases (96%). Primary technique effectiveness was 96%. During follow-up local tumor progression was observed in 15 metastases, representing a secondary technique effectiveness of 86.5%. The overall time to progression to the liver was 10.5 months. The estimated overall median survival was 58.6 months. There was no significant difference in terms of survival probability with respect to hormone receptor status, HER2 overexpression, and presence of isolated bone metastases. Survival was significantly lower among patients with extrahepatic disease, with the exception of skeletal metastases. We conclude that CT-guided RF ablation of liver metastases from breast cancer can be performed with a high degree of technical success and technique effectiveness, providing promising survival rates in patients with no visceral extrahepatic disease. Solitary bone metastases did not negatively affect survival probability after RF ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-BRA-01: SCIENCE COUNCIL JUNIOR INVESTIGATOR COMPETITION WINNER: Acceleration of a Limited-Angle Intrafraction Verification (LIVE) System Using Adaptive Prior Knowledge Based Image Estimation

Purpose: To develop an adaptive prior knowledge based image estimation method to reduce the scan angle needed in the LIVE system to reconstruct 4D-CBCT for intrafraction verification. Methods: The LIVE system has been previously proposed to reconstructs 4D volumetric images on-the-fly during arc treatment for intrafraction target verification and dose calculation. This system uses limited-angle beam’s eye view (BEV) MV cine images acquired from the treatment beam together with the orthogonally acquired limited-angle kV projections to reconstruct 4D-CBCT images for target verification during treatment. In this study, we developed an adaptive constrained free-form deformation reconstruction technique in LIVE to further reduce the scanning angle needed to reconstruct the CBCT images. This technique uses free form deformation with energy minimization to deform prior images to estimate 4D-CBCT based on projections acquired in limited angle (orthogonal 6°) during the treatment. Note that the prior images are adaptively updated using the latest CBCT images reconstructed by LIVE during treatment to utilize the continuity of patient motion.The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of this technique with LIVE system. A lung patient was simulated with different scenario, including baseline drifts, amplitude change and phase shift. Limited-angle orthogonal kV and beam’s eye view (BEV) MV projections were generated for each scenario. The CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate the reconstruction accuracy. Results: Using orthogonal-view of 6° kV and BEV- MV projections, the VPD/COMS values were 12.7±4.0%/0.7±0.5 mm, 13.0±5.1%/0.8±0.5 mm, and 11.4±5.4%/0.5±0.3 mm for the three scenarios, respectively. Conclusion: The technique enables LIVE to accurately reconstruct 4D-CBCT images using only orthogonal 6° angle, which greatly improves the efficiency and reduces dose of LIVE for intrafraction verification.

60 APPLIED LIFE SCIENCES↗

Towards Low-Temperature CVD Synthesis and Characterization of Mono- or Few-Layer Molybdenum Disulfide

Molybdenum disulfide (MoS 2 ) transistors are a promising alternative for the semiconductor industry due to their large on/off current ratio (>10 10 ), immunity to short-channel effects, and unique switching characteristics. MoS 2 has drawn considerable interest due to its intriguing electrical, optical, sensing, and catalytic properties. Monolayer MoS 2 is a semiconducting material with a direct band gap of ~1.9 eV, which can be tuned. Commercially, the aim of synthesizing a novel material is to grow high-quality samples over a large area and at a low cost. Although chemical vapor deposition (CVD) growth techniques are associated with a low-cost pathway and large-area material growth, a drawback concerns meeting the high crystalline quality required for nanoelectronic and optoelectronic applications. This research presents a lower-temperature CVD for the repeatable synthesis of large-size mono- or few-layer MoS 2 using the direct vapor phase sulfurization of MoO 3 . The samples grown on Si/SiO 2 substrates demonstrate a uniform single-crystalline quality in Raman spectroscopy, photoluminescence (PL), scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and scanning transmission electron microscopy. These characterization techniques were targeted to confirm the uniform thickness, stoichiometry, and lattice spacing of the MoS 2 layers. The MoS 2 crystals were deposited over the entire surface of the sample substrate. With a detailed discussion of the CVD setup and an explanation of the process parameters that influence nucleation and growth, this work opens a new platform for the repeatable synthesis of highly crystalline mono- or few-layer MoS 2 suitable for optoelectronic application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing the Frontiers in Nanocatalysis, Biointerfaces, and Renewable Energy Conversion by Innovations of Surface Techniques

The challenge of chemistry in the 21st century is to achieve 100% selectivity of the desired product molecule in multipath reactions ('green chemistry') and develop renewable energy based processes. Surface chemistry and catalysis play key roles in this enterprise. Development of in situ surface techniques such as high-pressure scanning tunneling microscopy, sum frequency generation (SFG) vibrational spectroscopy, time-resolved Fourier transform infrared methods, and ambient pressure X-ray photoelectron spectroscopy enabled the rapid advancement of three fields: nanocatalysts, biointerfaces, and renewable energy conversion chemistry. In materials nanoscience, synthetic methods have been developed to produce monodisperse metal and oxide nanoparticles (NPs) in the 0.8-10 nm range with controlled shape, oxidation states, and composition; these NPs can be used as selective catalysts since chemical selectivity appears to be dependent on all of these experimental parameters. New spectroscopic and microscopic techniques have been developed that operate under reaction conditions and reveal the dynamic change of molecular structure of catalysts and adsorbed molecules as the reactions proceed with changes in reaction intermediates, catalyst composition, and oxidation states. SFG vibrational spectroscopy detects amino acids, peptides, and proteins adsorbed at hydrophobic and hydrophilic interfaces and monitors the change of surface structure and interactions with coadsorbed water. Exothermic reactions and photons generate hot electrons in metal NPs that may be utilized in chemical energy conversion. The photosplitting of water and carbon dioxide, an important research direction in renewable energy conversion, is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation and Prediction of the Effect of Respiratory Motion on Whole Breast Radiation Therapy Dose Distributions

The standard treatment technique used for whole-breast irradiation can result in undesirable dose distributions in the treatment site, leading to skin reaction/fibrosis and pulmonary and cardiac toxicities. Hence, the technique has evolved from conventional wedged technique (CWT) to segment intensity-modulated radiation therapy (SIMRT) and beamlet IMRT (IMRT). However, these newer techniques feature more highly modulated dose distributions that may be affected by respiration. The purpose of this work was to conduct a simple study of the clinical impact of respiratory motion on breast radiotherapy dose distributions for the three treatment planning techniques. The ultimate goal was to determine which patients would benefit most from the use of motion management. Eight patients with early-stage breast cancer underwent a free-breathing (FB) computed tomography (CT) simulation, with medial and lateral markers placed on the skin. Two additional CT scans were obtained at the end of inspiration (EI) and the end of expiration (EE). The FB-CT scan was used to develop treatment plans using each technique. Each plan was then applied to EI and EE-CT scans. Compared with the FB CT scan, the medial markers moved up to 1.8 cm in the anterior-superior direction at the end of inspiration (EI-scan), and on average 8 mm. The CWT and SIMRT techniques were not 'sensitive' to respiratory motion, because the % clinical target volume (CTV) receiving 95% of the prescription dose (V{sub 95%}) remained constant for both techniques. For patients that had large respiratory motion indicated by marker movement >0.6 cm, differences in coverage of the CTV at the V100% between FB and EI for beamlet IMRT plans were on the order of >10% and up to 18%. A linear model was developed to relate the dosimetric coverage difference introduced by respiration with the motion information. With this model, the dosimetric coverage difference introduced by respiratory motion could be evaluated during patient CT simulation. An appropriate treatment method can be chosen after the simulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

Tailoring oxidation of aluminum nanoparticles reinforced with carbon nanotubes

In this report, the oxidation temperature and reaction enthalpy of Aluminum (Al) nanoparticles has been controlled by reinforcing with carbon nanotubes. The physical mixing method with ultrasonication was employed to synthesize CNT/Al nanocomposite powders. The micro-morphology of nanoconmposite powders has been analysed by scanning electron microscopy, energy dispersive spectroscopy, Raman spectroscopy and X-ray diffraction techniques. The oxidation behavior of nanocomposite powders analyzed by thermogravimetry/differential scanning calorimertry showed improvement in the exothermic enthalpy. Largest exothermic enthalpy of-1251J/g was observed for CNT (4 wt%)/Al nanocomposite.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stimulated Emission of Signal Photons from Dark Matter Waves

The manipulation of quantum states of light has resulted in significant advancements in both dark matter searches and gravitational wave detectors. Current dark matter searches operating in the microwave frequency range use nearly quantum-limited amplifiers. Future high frequency searches will use photon counting techniques to evade the standard quantum limit. We present a signal enhancement technique that utilizes a superconducting qubit to prepare a superconducting microwave cavity in a nonclassical Fock state and stimulate the emission of a photon from a dark matter wave. By initializing the cavity in an | n = 4 ⟩ Fock state, we demonstrate a quantum enhancement technique that increases the signal photon rate and hence also the dark matter scan rate each by a factor of 2.78. Using this technique, we conduct a dark photon search in a band around 5.965 GHz ( 24.67 μ eV ), where the kinetic mixing angle ε ≥ 4.35 × 10 − 13 is excluded at the 90% confidence level. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field-Flow Fractionation of Carbon Nanotubes and Related Materials

During the grant period, we carried out FFF studies of carbonaceous soot, single-walled and multi-walled carbon nanotubes, carbon nano-onions and polyoxometallates. FFF alone does not provide enough information to fully characterize samples, so our suite of characterization techniques grew to include light scattering (especially Photon Correlation Spectroscopy), scanning and transmission electron microscopy, thermogravimetric analysis and spectroscopic methods. We developed convenient techniques to deposit and examine minute FFF fractions by electron microscopy. In collaboration with Arthur Cammers (University of Kentucky), we used Flow Field-Flow Fractionation (Fl-FFF) to monitor the solution-phase growth of keplerates, a class of polyoxometallate (POM) nanoparticles. We monitored the evolution of Mo-POM nanostructures over the course of weeks by by using flow field-flow fractionation and corroborated the nanoparticle structures by using transmission electron microscopy (TEM). Total molybdenum in the solution and precipitate phases was monitored by using inductively coupled plasma analyses, and total Mo-POM concentration by following the UV-visible spectra of the solution phase. We observe crystallization-driven formation of (Mo132) keplerate and solution phase-driven evolution of structurally related nanoscopic species (3-60 nm). FFF analyses of other classes of materials were less successful. Attempts to analyze platelets of layered materials, including exfoliated graphite (graphene) and TaS2 and MoS2, were disappointing. We were not able to optimize flow conditions for the layered materials. The metal sulfides react with the aqueous carrier liquid and settle out of suspension quickly because of their high density.

36 MATERIALS SCIENCE↗