Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A DEEP 1.2 mm MAP OF THE LOCKMAN HOLE NORTH FIELD

We present deep 1.2 mm continuum mapping of a 566 arcmin{sup 2} area within the Lockman Hole North (LHN) field, previously a target of the Spitzer Wide-Area Infrared Extragalactic survey and extremely deep 20 cm mapping with the Very Large Array, which we have obtained using the Max-Planck millimeter bolometer (MAMBO) array on the IRAM 30 m telescope. After filtering, our full map has an rms sensitivity ranging from 0.45 to 1.5 mJy beam{sup -1}, with an average of 0.75 mJy beam{sup -1}. Using the pixel flux distribution (PFD) in a map made from our best data, we determine the shape, normalization, and approximate flux density cutoff for 1.2 mm number counts well below our nominal sensitivity and confusion limits. After validating our full data set through comparison with this map, we successfully detect 41 1.2 mm sources with signal-to-noise ratio (S/N) > 4.0 and S{sub 1.2{sub mm}} {approx_equal} 2-5 mJy. We use the most significant of these detections to directly determine the integral number counts down to 1.8 mJy, which are consistent with the results of the PFD analysis. Ninety-three percent of our 41 individual detections have 20 cm counterparts, 49% have Spitzer/MIPS 24 {mu}m counterparts, and one may have a significant Chandra X-ray counterpart. We resolve {approx_equal} 3% of the cosmic infrared background (CIB) at 1.2 mm into significant detections and directly estimate a 0.05 mJy faint-end cutoff for the counts that is consistent with the full intensity of the 1.2 mm CIB. The median redshift of our 17 detections with spectroscopic or robust photometric redshifts is z{sub median} = 2.3, and rises to z{sub median} = 2.9 when we include redshifts estimated from the radio/far-infrared spectral index. By using a nearest neighbor and angular correlation function analysis, we find evidence that our S/N > 4.0 detections are clustered at the 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-distance helioseismology of two realistic sunspot simulations

Linear time-distance helioseismic inversions are carried out using several filtering schemes to determine vector flow velocities within two ∼100{sup 2} Mm{sup 2} × 20 Mm realistic magnetohydrodynamic sunspot simulations of 25 hr. One simulation domain contains a model of a full sunspot (i.e., one with both an umbra and penumbra), while the other contains a pore (i.e., a spot without a penumbra). The goal is to test current helioseismic methods using these state-of-the-art simulations of magnetic structures. We find that horizontal flow correlations between inversion and simulation flow maps are reasonably high (∼0.5-0.8) in the upper 3 Mm at distances exceeding 25-30 Mm from spot center, but are substantially lower at smaller distances and larger depths. Inversions of forward-modeled travel times consistently outperform those of our measured travel times in terms of horizontal flow correlations, suggesting that our inability to recover flow structure near these active regions is largely due to the fact that we are unable to accurately measure travel times near strong magnetic features. In many cases the velocity amplitudes from the inversions underestimate those of the simulations by up to 50%, possibly indicating nonlinearity of the forward problem. In every case, we find that our inversions are unable to recover the vertical flow structure of the simulations at any depth.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A NEW STATISTIC FOR ANALYZING BARYON ACOUSTIC OSCILLATIONS

We introduce a new statistic {omega}{sub l}(r{sub s}) for measuring and analyzing large-scale structure and particularly the baryon acoustic oscillations. {omega}{sub l}(r{sub s}) is a band-filtered, configuration space statistic that is easily implemented and has advantages over the traditional power spectrum and correlation function estimators. Unlike these estimators, {omega}{sub l}(r{sub s}) can localize most of the acoustic information into a single dip at the acoustic scale while avoiding sensitivity to the poorly constrained large-scale power (i.e., the integral constraint) through the use of a localized and compensated filter. It is also sensitive to anisotropic clustering through pair counting and does not require any binning of data. We measure the shift in the acoustic peak due to nonlinear effects using the monopole {omega}{sub 0}(r{sub s}) derived from subsampled dark matter (DM) catalogs as well as from mock galaxy catalogs created via halo occupation distribution modeling. All of these are drawn from 44 realizations of 1024{sup 3} particle DM simulations in a 1 h {sup -1} Gpc box at z = 1. We compare these shifts with those obtained from the power spectrum and conclude that the results agree. We therefore expect that distance measurements obtained from {omega}{sub 0}(r{sub s}) and P(k) will be consistent with each other. We also show that it is possible to extract the same amount of acoustic information by fitting over a finite range using either {omega}{sub 0}(r{sub s}) or P(k) derived from equal volume surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fukushima Daiichi reactor source term attribution using cesium isotope ratios from contaminated environmental samples

Source term attribution of environmental contamination following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster is complicated by a large number of possible similar emission source terms (e.g. FDNPP reactor cores 1–3 and spent fuel ponds 1–4). Cesium isotopic analyses can be utilized to discriminate between environmental contamination from different FDNPP source terms and, if samples are sufficiently temporally resolved, potentially provide insights into the extent of reactor core damage at a given time. In this work, rice, soil, mushroom, and soybean samples taken 100–250 km from the FDNPP site were dissolved using microwave digestion. Radiocesium was extracted and purified using two sequential ammonium molybdophosphate-polyacrylonitrile columns, following which 135 Cs/ 137 Cs isotope ratios were measured using thermal ionization mass spectrometry (TIMS). Results were compared with data reported previously from locations to the northwest of FDNPP and 30 km to the south of FDNPP. 135 Cs/ 137 Cs isotope ratios from samples 100–250 km to the southwest of the FDNPP site show a consistent value of 0.376 ± 0.008. 135 Cs/ 137 Cs versus 134 Cs/ 137 Cs correlation plots suggest that radiocesium to the southwest is derived from a mixture of FDNPP reactor cores 1, 2, and 3. Conclusions from the cesium isotopic data are in agreement with those derived independently based upon the event chronology combined with meteorological conditions at the time of the disaster. In conclusion, cesium isotopic analyses provide a powerful tool for source term discrimination of environmental radiocesium contamination at the FDNPP site. For higher precision source term attribution and forensic determination of the FDNPP core conditions based upon cesium, analyses of a larger number of samples from locations to the north and south of the FDNPP site (particularly time-resolved air filter samples) are needed. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A DETAILED STUDY OF PHOTOMETRIC REDSHIFTS FOR GOODS-SOUTH GALAXIES

We use the deepest and the most comprehensive photometric data currently available for GOODS-South (GOODS-S) galaxies to measure their photometric redshifts. The photometry includes VLT/VIMOS (U band), HST/ACS (F435W, F606W, F775W, and F850LP bands), VLT/ISAAC (J, H, and K{sub s} bands), and four Spitzer/IRAC channels (3.6, 4.5, 5.8, and 8.0 {mu}m). The catalog is selected in the z band (F850LP) and photometry in each band is carried out using the recently completed TFIT algorithm, which performs point-spread function (PSF) matched photometry uniformly across different instruments and filters, despite large variations in PSFs and pixel scales. Photometric redshifts are derived using the GOODZ code, which is based on the template fitting method using priors. The code also implements 'training' of the template spectral energy distribution (SED) set, using available spectroscopic redshifts in order to minimize systematic differences between the templates and the SEDs of the observed galaxies. Our final catalog covers an area of 153 arcmin{sup 2} and includes photometric redshifts for a total of 32,505 objects. The scatter between our estimated photometric and spectroscopic redshifts is {sigma} = 0.040 with 3.7% outliers to the full z-band depth of our catalog, decreasing to {sigma} = 0.039 and 2.1% outliers at a magnitude limit m{sub z} < 24.5. This is consistent with the best results previously published for GOODS-S galaxies, however, the present catalog is the deepest yet available and provides photometric redshifts for significantly more objects to deeper flux limits and higher redshifts than earlier works. Furthermore, we show that the photometric redshifts estimated here for galaxies selected as dropouts are consistent with those expected based on the Lyman break technique.

79 ASTRONOMY AND ASTROPHYSICS↗

A new architecture as transparent electrodes for solar and IR applications based on photonic structures via soft lithography

Transparent conducting electrodes with the combination of high optical transmission and good electrical conductivity are essential for solar energy harvesting and electric lighting devices. Currently, indium tin oxide (ITO) is used because ITO offers relatively high transparency (>80%) to visible light and low sheet resistance (R s = 10 ohms/square (Ω /2)) for electrical conduction. However, ITO is costly due to limited indium reserves, and it is brittle. These disadvantages have motivated the search for other conducting electrodes with similar or better properties. There has been research on a variety of electrode structures involving carbon nanotube networks, graphene films, nanowire and nanopatterned meshes and grids. Due to their novel characteristics in light manipulation and collection, photonic crystal structures show promise for further improvement. Here, we report on a new architecture consisting of nanoscale high aspect ratio metallic photonic structures as transparent electrodes fabricated via a combination of processes. For (Au) and silver (Ag) structures, the visible light transmission can reach as high as 80%, and the sheet resistance of the structure can be as low as 3.2Ω /2. The optical transparency of the high aspect ratio metal structures at visible wavelength range is comparable to that of ITO glass, while their sheet resistance is more than 3 times lower, which indicates a much higher electrical conductivity of the metal structures. Furthermore, the high aspect ratio metal structures have very high infrared (IR) reflection (90%) for the transverse magnetic (TM) mode, which can lead to the development of fabrication of metallic structures as IR filters for heat control applications. Investigations of interdigitated structures based on the high aspect ratio metal electrodes are ongoing to study the feasibility in smart window applications in light transmission modulation.

14 SOLAR ENERGY↗

Is ""predictability"" in computational sciences a myth?

Within the last two decades, Modeling and Simulation (M&S) has become the tool of choice to investigate the behavior of complex phenomena. Successes encountered in 'hard' sciences are prompting interest to apply a similar approach to Computational Social Sciences in support, for example, of national security applications faced by the Intelligence Community (IC). This manuscript attempts to contribute to the debate on the relevance of M&S to IC problems by offering an overview of what it takes to reach 'predictability' in computational sciences. Even though models developed in 'soft' and 'hard' sciences are different, useful analogies can be drawn. The starting point is to view numerical simulations as 'filters' capable to represent information only within specific length, time or energy bandwidths. This simplified view leads to the discussion of resolving versus modeling which motivates the need for sub-scale modeling. The role that modeling assumptions play in 'hiding' our lack-of-knowledge about sub-scale phenomena is explained which leads to discussing uncertainty in simulations. It is argued that the uncertainty caused by resolution and modeling assumptions should be dealt with differently than uncertainty due to randomness or variability. The corollary is that a predictive capability cannot be defined solely as accuracy, or ability of predictions to match the available physical observations. We propose that 'predictability' is the demonstration that predictions from a class of 'equivalent' models are as consistent as possible. Equivalency stems from defining models that share a minimum requirement of accuracy, while being equally robust to the sources of lack-of-knowledge in the problem. Examples in computational physics and engineering are given to illustrate the discussion.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Interplay between experiments and calculations for organometallic clusters and caged clusters

Clusters consisting of 10-1000 atoms exhibit size-dependent electronic and geometric properties. In particular, composite clusters consisting of several elements and/or components provide a promising way for a bottom-up approach for designing functional advanced materials, because the functionality of the composite clusters can be optimized not only by the cluster size but also by their compositions. In the formation of composite clusters, their geometric symmetry and dimensionality are emphasized to control the physical and chemical properties, because selective and anisotropic enhancements for optical, chemical, and magnetic properties can be expected. Organometallic clusters and caged clusters are demonstrated as a representative example of designing the functionality of the composite clusters. Organometallic vanadium-benzene forms a one dimensional sandwich structure showing ferromagnetic behaviors and anomalously large HOMO-LUMO gap differences of two spin orbitals, which can be regarded as spin-filter components for cluster-based spintronic devices. Caged clusters of aluminum (Al) are well stabilized both geometrically and electronically at Al{sub 12}X, behaving as a “superatom”.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of entangled-photons by a quantum dot cascade source in polarized cavities: Using cavity resonances to boost signals and preserve the entanglements

Motivated by recent advances in the development of single photon emitters for quantum information sciences, here we design and formulate a quantum cascade model that describes cascade emission by a quantum dot (QD) in a cavity structure while preserving entanglement that stores information needed for single photon emission. The theoretical approach is based on a photonic structure that consists of two orthogonal cavities in which resonance with either the first or second of the two emitted photons is possible, leading to amplification and rerouting of the entangled light. The cavity–QD scheme uses a four-level cascade emitter that involves three levels for each polarization, leading to two spatially entangled photons for each polarization. By solving the Schrodinger equation, we identify the characteristic properties of the system, which can be used in conjunction with optimization techniques to achieve the “best” design relative to a set of prioritized criteria or constraints in our optical system. The theoretical investigations include an analysis of emission spectra in addition to the joint spectral density profile, and the results demonstrate the ability of the cavities to act as frequency filters for the photons that make up the entanglements and to modify entanglement properties. The results provide new opportunities for the experimental design and engineering of on-demand single photon sources.

Chemistry↗

Fermi Bubble Edges: Spectrum and Diffusion Function

Current measurements of the γ-ray Fermi bubbles (FB) are based on model-dependent tracers, carry substantial systematic uncertainties, and contain some discrepancies between each other. We show that gradient filters pick out the FB edges, which are found to smoothly connect to the bipolar X-ray structure emanating from the Galactic center, thus supporting the interpretation of the FBs as a Galactic-scale phenomenon. The sharp edges facilitate a direct, model-free measurement of the peripheral FB spectrum. The result is strikingly similar to the full FB-integrated spectrum, softened by a power law of index η ≃ (0.2–0.3). This is naturally explained, in both hadronic and leptonic models, if cosmic rays are injected at the edge, and diffuse away preferentially at higher energies E. The inferred, averaged diffusion function in the (more plausible) leptonic model, D(E)≃10{sup 29.5}(E/10GeV){sup 0.48±0.02} cm{sup 2} s{sup −1}, is consistent with estimates for Kraichnan-like turbulence. Our results, in particular the minute spatial variations in η, indicate that the FB edge is a strong, Mach ≳5, forward shock.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Physics-Informed Neural Network Performance for Seismic Discrimination between Earthquakes and Explosions

In this article, we evaluate adding a weak physics constraint, that is, a physics‐based empirical relationship, to the loss function with a physics‐informed manner in local distance explosion discrimination in the hope of improving the generalization capability of the machine learning (ML) model. We compare the proposed model with the two‐branch model we previously developed, as well as with a pure data‐driven model. Unexpectedly, the proposed model did not consistently outperform the pure data‐driven model. By varying the level of inconsistency in the training data, we find this approach is modulated by the strength of the physics relationship. In conclusion, this result has important implications for how to best incorporate physical constraints in ML models.

58 GEOSCIENCES↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

THE RELATION BETWEEN BLACK HOLE MASS AND HOST SPHEROID STELLAR MASS OUT TO z {approx} 2

We combine Hubble Space Telescope images from the Great Observatories Origins Deep Survey with archival Very Large Telescope and Keck spectra of a sample of 11 X-ray-selected broad-line active galactic nuclei in the redshift range 1 < z < 2 to study the black-hole-mass-stellar-mass relation out to a look-back time of 10 Gyr. Stellar masses of the spheroidal component (M{sub sph,*}) are derived from multi-filter surface photometry. Black hole masses (M{sub BH}) are estimated from the width of the broad Mg II emission line and the 3000 A nuclear luminosity. Comparing with a uniformly measured local sample and taking into account selection effects, we find evolution in the form M{sub BH}/M{sub sph,*}{proportional_to}(1 + z){sup 1.96{+-}}0{sup .55}, in agreement with our earlier studies based on spheroid luminosity. However, this result is more accurate because it does not require a correction for luminosity evolution and therefore avoids the related and dominant systematic uncertainty. We also measure total stellar masses (M{sub host,*}). Combining our sample with data from the literature, we find M{sub BH}/M{sub host,*}{proportional_to}(1 + z){sup 1.15{+-}0.15}, consistent with the hypothesis that black holes (in the range M{sub BH} {approx} 10{sup 8-9} M{sub Sun }) pre-date the formation of their host galaxies. Roughly, one-third of our objects reside in spiral galaxies; none of the host galaxies reveal signs of interaction or major merger activity. Combined with the slower evolution in host stellar masses compared to spheroid stellar masses, our results indicate that secular evolution or minor mergers play a non-negligible role in growing both BHs and spheroids.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring scale-dependent shape anisotropy by coarse-graining: Application to inhomogeneous Rayleigh-Taylor turbulence

Here, we generalize the “filtering spectrum” to probe scales along different directions by spatial coarse-graining. This multidimensional filtering spectrum quantifies the spectral content of flows that are not necessarily homogeneous. From multidimensional spectral information, we propose a simple metric for shape anisotropy at various scales. The method is applied to simulations of two-dimensional (2D) and 3D Rayleigh-Taylor (RT) turbulence, which is inhomogeneous and anisotropic. We show that 3D RT has clear shape anisotropy at large scales with approximately 4:3 vertical to horizontal aspect ratio but tends toward isotropy at small scales as expected. In sharp contrast, we find that RT in 2D simulations, which are still the main modeling framework for many applications, is isotropic at large scales and its shape anisotropy increases at smaller scales where structures tend to be horizontally elongated. While this may be surprising, it is consistent with recent results that large-scale isotropy in 2D RT is due to the generation of a large-scale overturning circulation via an upscale cascade, while small-scale anisotropy is due to the stable stratification resultant from such overturning and the inefficient mixing in 2D.

42 ENGINEERING↗

A semiempirical linear model of indirect, flat-panel x-ray detectors

Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r{sup 2} of signal mean to kV: 0.91, 0.93, 0.86, and 0.99 for 0.1-mm Sn, 0.2-mm Cu, 1.5-mm Al, and 0.05-mm Ag, respectively; r{sup 2} of signal variance to kV: 0.99 for all four filters). The comparison of the signal and noise (mean, variance, and NPS) between the simulated and measured air scan images suggested that this model was reasonable in predicting accurate signal statistics of air scan images using absolute percent error. Overall, the model was found to be accurate in estimating signal statistics and spatial correlation between the detector elements of the images acquired with indirect, flat-panel x-ray detectors. Conclusions: The semiempirical linear model of the indirect, flat-panel x-ray detectors was described and validated with images of air scans. The model was found to be a useful tool in understanding the signal and noise transfer within indirect, flat-panel x-ray detector systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tradeoffs in Prameter Values for Optional Performance

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively, In general, continuous operation of most commercial ultrasonic transducers above 50°C is challenging because of transducer material incompatibility with high temperature. High-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150⁰C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗