Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Switching kinetics in ferroelectric zinc magnesium oxide thin films

The switching kinetics of RF-magnetron reactively sputtered ~200 nm thick Zn 1-x Mg x O (ZMO) ferroelectric thin films with x = 0.41 and x = 0.27 prepared on Pt/Ti/SiO 2 /Si substrates were studied at applied fields near the coercive fields, ranging from 3.4 to 5.1 MV cm -1 , and at temperatures ranging from room temperature to 100 °C. Polarization reversal in ZMO followss the Kolmogorov-Avrami-Ishibashi kinetics model for nucleation and growth at applied fields near the coercive field, and obeys an individual column switching (ICS) model at higher applied fields required to switch most of the spontaneous polarization. Switching in the high-applied field regime can be described using either the Gaussian or inverse gamma distribution functions depending on the mole fraction of magnesium in the film. The switching current transients of the high-Mg content ZMO film (x = 0.41) are always bi-modal, whereas the low Mg composition film (x = 0.27) is described by the Gaussian distribution initially following wake-up, and becomes bimodal with continued cycling. Rayleigh-like behavior of the dielectric constant revealed a simultaneous increase of the irreversible and decrease of the reversible contributions to the dielectric constant, which was ascribed to an increase in the density of mobile domain walls with cycling and resulted in faster switching.

30 DIRECT ENERGY CONVERSION↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New sulfur adsorbents derived from layered double hydroxides: II. DRIFTS study of COS and H 2 S adsorption

H 2 S and COS adsorption were studied on two calcined layered double hydroxides (LDHs), Mg 0.75 Al 0.25 (OH) 2 (CO 3 ) 0.125 and Mg 0.65 Al 0.35 (OH) 2 (CO 3 ) 0.175 , using Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) and a chemisorption apparatus. Both demonstrated the ability to irreversibly adsorb H 2 S, corresponding to uptakes of 1.54 and 1.76 mol/m 2 respectively, but Mg 0.75 Al 0.25 had a significantly larger capacity for COS, 1.62 mol/m 2 compared to 0.80 mol/m 2 for Mg 0.65 Al 0.35 . Analysis of the DRIFT spectra suggests the adsorption of H 2 S proceeds via the substitution of lattice oxygen with sulfur, resulting in the formation of H 2 O on the surface. COS adsorption is more complicated, although it appears that a similar substitution of lattice oxygen with sulfur occurs. This results in the formation of CO 2 and subsequently bicarbonates and carbonates. The formation of hydrogen thiocarbonate is also involved, although this form is generally only observed in the later stages of adsorption and appears to form at the expense of bicarbonate. Lastly, the Mg 0.75 Al 0.25 LDH retained its ability to adsorb COS in the presence of propene.

30 DIRECT ENERGY CONVERSION↗

Cobalt-polypyrrole-carbon black (Co-PPY-CB) Electrocatalysts for the Oxygen Reduction Reaction (ORR) in Fuel Cells: Composition and Kinetic Activity

Electrocatalysts consisting of polypyrrole (PPY) and Co deposited on carbon black (CB) at several compositions were prepared and tested for the oxygen reduction reaction (ORR) in a HClO4 buffer (pH = 1) using a rotating ring-disk electrode (RRDE). It was determined that the most favorable catalyst composition (prior to calcination) had a CB:PPY weight ratio of 2 and a pyrrole:Co (i.e., PY:Co) molar ratio of 4. This catalyst had an onset potential of 0.785 V (vs. RHE) and a mass activity of ca. 1 A/g{sub cata} at the fuel cell relevant voltage of 0.65 V. Furthermore, it was found that the number of electrons exchanged during the ORR with the catalyst was ca. 3.5 and resulted in 28% yield of H{sub 2}O{sub 2} at 0.65 V, which hints to an indirect 4e{sup -} reduction of O{sub 2} to H{sub 2}O, with H{sub 2}O{sub 2} as an intermdiate. From energy dispersive spectroscopy (EDS) and extended X-ray absorption fine structure (EXAFS) analysis, it is proposed that a PY:Co ratio of 4 favors the formation, prior to calcination, in the catalyst precursor of Co-N complexes in which Co is coordinated to 3 or 4 N atoms, resulting in strong Co-N interactions that limit the formation upon calcination of low ORR activity Co nanoparticles. These Co-N complexes give rise upon calcination to CoN{sub x-2} sites in which the coordination of Co could favor the adsorption on them of O{sub 2}, which would make those sites particularly active and selective. At the same mass acitivity of 1 A/g{sub cata}, the voltage yielded by the catalyst was 200 mV lower than that for a state-of-the-art Pt (10 wt.%) catalyst, whoch H{sub 2}O{sub 2} output at 0.85 V was 39% and involves the exchange of 3.2 e{sup -}, overall making our material an attractive substitute to noble metal ORR electrocatalysts.

04 OIL SHALES AND TAR SANDS↗

Elucidation of Fe-N-C electrocatalyst active site functionality via in-situ X-ray absorption and operando determination of oxygen reduction reaction kinetics in a PEFC

In the past decade the notable effort placed on improving intrinsic electrochemical kinetics of platinum group metal (PGM)-free electrocatalysts for the oxygen reduction reaction (ORR) has led to a significant improvement in both performance and understanding of this class of electrocatalysts. However, a limited amount of this development and understanding has been undertaken using operando electrochemical diagnostics at the membrane electrode assembly (MEA) level. In this work, the operando ORR kinetics on an atomically dispersed iron-nitrogen-carbon ((AD)Fe-N-C) PGM-free electrocatalyst have been examined to extract the reaction order and the activation energy of the ORR. The experiments were carefully designed to ensure the stability/predictability of the electrocatalyst during the data collection process and thus validate the relevance of the values obtained for the aforementioned parameters. A kinetic model that considers a potential-dependent availability of active sites (θ) is proposed. Active site availability is shown to be a function of both the change in the oxidation state (nR) and the redox potential at which the metal center transitions from a higher oxidation state to a lower one (). The resulting model fitting parameters for nR and (0.71 and 0.788 V, respectively) obtained from the analysis of operando data correlate well with those from in situ X-ray absorption near edge structure measurements (nR=0.57) and in situ cyclic voltammetry measurements (0.75 V < <0.8 V) in the MEA environment. The resulting model provides an excellent fit of MEA performance across the range of pressures, temperatures, and potentials under which the data were collected.

Activation energy↗

A highly oxygen reduction reaction active and CO 2 durable high-entropy cathode for solid oxide fuel cells

One big obstacle for the oxygen reduction reaction (ORR) electrode in solid oxide fuel cells (SOFCs) is the poor reaction activity and fast degradations caused by CO 2 poisoning. Here, in this study, we report our design of an active A-site Ca-rich high-entropy Pr 0.1875 Ba 0.1875 Sr 0.1875 La 0.1875 Ca 0.25 CoO 3-δ (PBSLC 25 C) electrode, guided by the O p-band theory. Here, when applied as a cathode in solid oxide fuel cells (SOFCs), it demonstrates high ORR activity and excellent CO 2 tolerance under realistic operating conditions. Ni-YSZ-based anode-supported cells with PBSLC 25 C cathodes demonstrate excellent peak power densities of 1.14 W cm -2 , 1.04 W cm -2 , and 0.77 W cm -2 in the air with 1%, 5%, and 10% CO 2 , respectively, at 750 °C. The engineered high-entropy PBSLC 25 C effectively diminishes the CO 2 poisoning effect and maintains active surfaces for fast oxygen exchange, as confirmed by the cell durability test in air containing CO 2 (5 and 10 vol%), Raman spectroscopy, and density functional theory calculations.

30 DIRECT ENERGY CONVERSION↗

Realizing efficient operations of Ni-cermet-based fuel cells on hydrocarbons via an in situ self-assembled metal/oxide nano-heterostructured catalyst

Operating Ni-cermet-based fuel cells on hydrocarbons is charming by largely hindered by poor coking tolerance and severe deterioration. Here, in this study, we report an effective metal/oxide nano-heterostructured catalyst with a nominal composition of Pr 0.95 Ru 0.05 O 2-δ (PRO), which is in situ self-assembled to a Pr 0.95 Ru 0.05-x O 2-δ oxide frame coated with Ru metallic nanoparticles (denoted as Ru/PRO) under the operation condition. When applied to the Ni-cermet (Ni-YSZ) anodes, the cells achieve decent peak power densities of 1.784 and 1.870 W cm -2 on CH 4 and C 3 H 8 with only 3% H 2 O at 750 °C, respectively. Moreover, the cells with Ru/PRO-coated anode demonstrate excellent durability when operated on CH 4 for ~ 220 h and C 3 H 8 for ~115 h. It is demonstrated that the Ru/PRO generates hydroxyl species that react with carbon species, followed by the formation of COH intermediates on Ni anode surfaces for removing the coking, as confirmed by experiments and computations.

30 DIRECT ENERGY CONVERSION↗

Exsolution of NiCo alloys over Ruddlesden-Popper perovskite for mild electrochemical synthesis of ammonia on protonic ceramic electrochemical cells

Ammonia synthesis from renewable energies on protonic ceramic electrochemical cells (PCECs) shows great potential. The primary challenges in ammonia synthesis on PCECs include sluggish catalytic activity, competition from the hydrogen evolution reaction, and unsatisfactory durability of the cathode, which is the active site of ammonia generation. Here, in this study, we report an elaborate design of the cathode with an intended formula of Pr 4 Ni 1.79 Co 1.2R u 0.01 O 10-δ , where NiCo alloy nanoparticles are exsolved from Ruddlesden-Popper perovskite substrates after the reduction in 5 % H 2 /Ar at 400 °C for 1 h, for electrocatalysis of the nitrogen reduction reaction to ammonia. The host material Pr 4 Ni 1.8 Co 1.2 O 10-δ with embeddable layered structure and stability was deliberately chosen to fix the Ru cation and maximize the catalytic activity of NiCo. Also, density functional theory calculations suggest that Ru doping provides an optimal balance between structural stability and redox activity, facilitating the controlled exsolution of NiCo nanoparticles and enhancing catalytic performance. As a result, the composite electrode with exsolved NiCo alloy and abundant oxygen vacancies on fuel-electrode-supported PCECs achieves a superior electrochemical activity towards ammonia synthesis: a peak ammonia formation rate of 27.84 μg h −1 cm −2 and excellent Faradaic efficiencies of 62.6 % at 350 °C.

30 DIRECT ENERGY CONVERSION↗

Heterostructured nano-catalysts with efficient metal-oxide interfaces unlock high-performance direct methanol protonic ceramic fuel cells

Direct methanol protonic ceramic fuel cells (PCFCs) are attractive due to their low cost, convenient storage, and high volumetric energy density, as well as their suitability for transportation. However, the poor coking tolerance of conventional nickel-based anodes leads to their susceptibility to severe carbon deposition and significant deactivation after long-term exposure to hydrocarbons. Herein, we report a nano-catalyst of Ce 0.6 Ni 0.2 Cu 0.2 O 2 with a heterogeneous structure that is spontaneously reduced into a Ce 0.6 Ni 0.2-x Cu 0.2-x O 2-δ (CeNCO) oxide framework interfaced with a nano NiCu alloy (denoted as NC/CeNCO) under operating conditions, as confirmed by analyses of X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy. A Ni-BaCe 0.7 Y 0.06 Yb 0.06 Zr 0.06 Hf 0.06 Gd 0.06 O 3-δ anode-supported PCFC employing the NC/CeNCO metal-oxide catalyst achieved a peak power density of 1.11 W cm −2 and operational stability of about 100 h at 700 °C when fueled by 35 % CH 3 OH-15 % H 2 O-50 % N 2 . In conclusion, the enhanced performance and coking resistance are attributed to the efficient interfaces of Ni, Cu, and ceria-based oxide in NC/CeNCO for CH 3 OH reforming, as confirmed by analyses of electrochemical performance and Raman spectroscopy with density functional theory calculations, revealing that these interfaces can enhance CH 3 OH activation and promote efficient OH-mediated carbon removal via COH intermediates.

30 DIRECT ENERGY CONVERSION↗

A new predictive multi-zone model for HCCI engine combustion

Here, this work introduces a new predictive multi-zone model for the description of combustion in Homogeneous Charge Compression Ignition (HCCI) engines. The model exploits the existing OpenSMOKE++ computational suite to handle detailed kinetic mechanisms, providing reliable predictions of the in-cylinder auto-ignition processes. All the elements with a significant impact on the combustion performances and emissions, like turbulence, heat and mass exchanges, crevices, residual burned gases, thermal and feed stratification are taken into account. Compared to other computational approaches, this model improves the description of mixture stratification phenomena by coupling a wall heat transfer model derived from CFD application with a proper turbulence model. Furthermore, the calibration of this multi-zone model requires only three parameters, which can be derived from a non-reactive CFD simulation: these adaptive variables depend only on the engine geometry and remain fixed across a wide range of operating conditions, allowing the prediction of auto-ignition, pressure traces and pollutants. This computational framework enables the use of detail kinetic mechanisms, as well as Rate of Production Analysis (RoPA) and Sensitivity Analysis (SA) to investigate the complex chemistry involved in the auto-ignition and the pollutants formation processes. In the final sections of the paper, these capabilities are demonstrated through the comparison with experimental data.

30 DIRECT ENERGY CONVERSION↗

Hydrogen desorption using honeycomb finned heat exchangers integrated in adsorbent storage systems

One of the main technical hurdles associated with adsorbent based hydrogen storage systems is relative to their ability to discharge hydrogen effectively, as dictated by fuel cell requirements. In this study, a new honeycomb finned heat exchanger concept was examined to evaluate its potential as a heat transfer system for hydrogen desorption. A bench scale 0.5 L vessel was equipped with the proposed heat exchanger, filled with MOF-5® adsorbent material. The heating power, required to desorb hydrogen, was provided by a 100 W electric heater placed in the center of the honeycomb structure. Two desorption tests, at room temperature and under cryogenic temperatures, were carried out to evaluate the hydrogen desorption performance of the proposed system under different operating conditions. The bench scale vessel performance was verified from both an experimental and a modeling point of view, demonstrating the ability to desorb about 45% of the adsorbed hydrogen in reduced time and applying low heating power. Further modeling analyses were also carried out showing the potential of the proposed system to reach high hydrogen discharging rates at cryogenic temperature conditions and operating pressures between 100 bar and 5 bar. The proposed adsorption system also demonstrated to be able to discharge all the available hydrogen in less than 500 s operating at cryogenic conditions and with a nominal heating power of 100 W.

25 ENERGY STORAGE↗

Techno-economic analysis of high-efficiency natural-gas generators for residential combined heat and power

Residential combined heat and power (CHP) systems produce electricity onsite while utilizing waste heat to supplement home heating requirements, which can lead to significant reductions in CO 2 emissions and primary energy consumption. However, the current deployment of such CHP systems in the U.S. residential sector is extremely low primarily due to their high cost, short system life, and low system efficiency. Based on an analysis of average energy consumption of representative single-family homes in 10 U.S. cities across 7 different climate zones, it is concluded that there is no one-size-fits-all residential CHP system, but that a range of products are more likely to reflect consumer preferences. It is further identified via a systematic techno-economic analysis (TEA) that high-efficiency (e.g., 30% - 40% fuel to electricity), long-life (e.g., 15 years), low-cost (preferably less than U.S. $2,500 installed price), and low emissions are key requirements to enable widespread deployment of CHP systems in the U.S. residential sector. This article analyzes how the payback period would change for each city by varying nearly a dozen parameters and concludes with an evaluation on maximum market penetration based on a given set of parameters, and the resulting energy and emissions savings that can be practically achieved in some scenarios.

03 NATURAL GAS↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗