Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution System State Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Water-Energy Considerations in California’s Agricultural Sector and Opportunities to Provide Flexibility to California’s Grid

Water and energy use on farms are deeply linked, and trends changing the way water is used on farms have implications for the electrical grid, and vice versa. In 2014, California’s agricultural sector accounted for approximately 80% of the state’s water consumption and 5% of its electricity use. The majority of the electricity was for surface conveyance and groundwater pumping. Diminishing surface water availability and increasing reliance on groundwater pumping are likely to increase future energy demand. These trends are coincident with farms embracing new precision irrigation technologies that increase water productivity and crop yield, but may have the potential of other collateral effects, such as increasing energy intensity of irrigation and total electricity use, and thus demand on the grid. The impacts of these technologies and their loads on the electrical grid have been explored only to a limited degree, and the potential grid benefits afforded by these technologies have been studied even less. For example, studies show that California’s increasing adoption of renewable electricity may result in excess generation during certain periods of the day, and that responsive load management (i.e. demand response) may be a cost-effective method to shift loads to utilize this excess generation. The degree to which farms in California do or can provide responsive loads has not been explored. In this paper, we explore whether farms that are adopting technologies and automation for irrigation management can provide co-benefits to the grower and the electrical grid. To do so, we define the characteristics of future grid needs specifically related to responsive load management, explore existing market mechanisms and policies for proving those resources, estimate the temporal distribution of energy use for irrigation in California, and develop scenarios of how irrigation loads might meet these needs. We conclude by exploring potential ancillary service benefits and associated revenues that California’s agricultural industry may provide. Ancillary services include using loads to dynamically adjust demand on the system to alleviate short-run ramps and disturbances at timescales ranging from seconds up to an hour. With higher penetrations of renewable resources, larger quantities of ancillary services will be necessary and may become more valuable to the grid than traditional demand response. Ancillary services from agricultural loads is a nascent topic, and no such analysis has been conducted to quantify its benefits to our knowledge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The effect of dry and wet deposition of condensable vapors on secondary organic aerosols concentrations over the continental US

The effect of dry and wet deposition of semi-volatile organic compounds (SVOCs) in the gas phase on the concentrations of secondary organic aerosol (SOA) is reassessed using recently derived water solubility information. The water solubility of SVOCs was implemented as a function of their volatility distribution within the WRF-Chem regional chemistry transport model, and simulations were carried out over the continental United States for the year 2010. Results show that including dry and wet removal of gas-phase SVOCs reduces annual average surface concentrations of anthropogenic and biogenic SOA by 48 and 63% respectively over the continental US. Dry deposition of gas-phase SVOCs is found to be more effective than wet deposition in reducing SOA concentrations (−40 vs. −8% for anthropogenics, and −52 vs. −11% for biogenics). Reductions for biogenic SOA are found to be higher due to the higher water solubility of biogenic SVOCs. The majority of the total mass of SVOC + SOA is actually deposited via the gas phase (61% for anthropogenics and 76% for biogenics). Results are sensitive to assumptions made in the dry deposition scheme, but gas-phase deposition of SVOCs remains crucial even under conservative estimates. Considering reactivity of gas-phase SVOCs in the dry deposition scheme was found to be negligible. Further sensitivity studies where we reduce the volatility of organic matter show that consideration of gas-phase SVOC removal still reduces average SOA concentrations by 31% on average. We consider this a lower bound for the effect of gas-phase SVOC removal on SOA concentrations. A saturation effect is observed for Henry's law constants above 10 8 M atm −1 , suggesting an upper bound of reductions in surface level SOA concentrations by 60% through removal of gas-phase SVOCs. Other models that do not consider dry and wet removal of gas-phase SVOCs would hence overestimate SOA concentrations by roughly 50%. Assumptions about the water solubility of SVOCs made in some current modeling systems ( H * = H * (CH 3 COOH); H * = 10 5 M atm −1 ; H * = H * (HNO 3 )) still lead to an overestimation of 35%/25%/10% compared to our best estimate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seminar 13 - Advanced Methods for Grid Integration of High-Performance Residential Communities

High-performance residential communities such as net-zero energy (NZE) and NZE-ready communities are emerging across the United States as many cities and states have committed to achieve ambitious energy efficiency and renewable energy goals between now and 2050. The achievement of these goals will transform the nation's communities into the holistic paradigms consisting of pervasive solar photovoltaics (PVs) and other renewable distributed energy resources, energy storage and flexible loads. However, integrating residential communities with high PV penetration may bring many challenges to the grid. For example, during many hours of the year, electric power is flowing out of PV-enabled homes and back into the grid. When this happens simultaneously in many nearby homes, distribution feeder voltage can be raised significantly. Intermittent solar power can also cause voltage flickers, leading to potential damages on both distribution feeder and home appliances. Existing solutions, such as PV curtailment, battery storage, and direct load control, are not able to address all the challenges in a cost-effective way. Better understanding is needed on how to deploy rooftop PV, how to predict building loads, and how to coordinate the homes in a community to enhance grid reliability. This seminar consists of four integral presentations that cover different aspects of a solution to these challenges. First, we will present an automated method to identify the best surfaces to deploy PV and size PV according to the PV penetration goals in a community. Second, we will present a streamlined way to create gray-box building models that are suitable for large-scale building-grid co-simulation. Next, we will present a data-driven method to estimate the end-use energy consumption to better coordinate the behind-the-meter resources to reduce utility cost, provide grid services, and improve renewable energy integration. Lastly, we will present a hierarchical control system that integrates the building models and the estimated non-dispatchable loads into the decision-making process to enhance the reliability and resilience of the residential community. Simulation results from an NZE-ready community in Fort Collins, Colorado will be presented in all four presentations and the guidelines on better grid integration of residential communities will be provided.

14 SOLAR ENERGY↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, Volt/VAr optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder-head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure (AMI)↗

Physics-based hybrid machine learning for critical heat flux prediction with uncertainty quantification

Critical heat flux (CHF) is a key quantity in nuclear system modeling due to its impact on heat transfer, safety margins, and reactor performance. This study develops and validates an uncertainty-aware hybrid modeling approach that combines machine learning with physics-based models to predict CHF in cases of dryout. The Biasi and Bowring empirical correlations were paired with three ML uncertainty quantification (UQ) techniques: deep neural network (DNN) ensembles, Bayesian neural networks (BNNs), and deep Gaussian processes (DGPs). A pure ML model without a base model was evaluated for comparison. Model performance was assessed under plentiful (7,350 points) and limited (9 points) training data scenarios using parity, uncertainty distributions, and calibration curves. Results show that the Biasi hybrid DNN ensemble achieved the best overall performance, with a mean absolute relative error of 1.846%, and well-calibrated uncertainty estimates. The BNN-based hybrids showed slightly higher error (2.14%) but superior uncertainty calibration. DGP models underperformed, with over 6% error and poor uncertainty calibration. All hybrid models outperformed pure machine learning configurations, demonstrating resistance against data scarcity. These findings indicate that hybrid modeling significantly improves predictive accuracy, interpretability, and resilience to data scarcity. The integration of uncertainty awareness provides actionable confidence in CHF predictions, which is vital for safety-critical decisions in nuclear applications. This hybrid approach offers a viable pathway for deploying ML models in reactor analysis tools while preserving domain knowledge and physical consistency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dual-precipitates enhance fatigue resistance in an additively manufactured high-entropy alloy

To accomplish the intense desire of high-strength materials for enhanced energy-efficiency, recent research applies a combined strategy of additive-manufacturing and precipitation-strengthening in high entropy alloys. In a context, Al 0.2 Co 1.5 CrFeNi 1.5 Ti 0.3 nanoprecipitation-strengthened system was developed, demonstrating very convincing strength and toughness. Moreover, additive-manufacturing facilitated additional strength by well-decorated cell-boundaries with blocky L2 1 precipitates and homogeneously distributed L1 2 precipitates. However, fatigue research of this alloy remained unexplored despite being the main precursor for structural applications. In this study low-cycle fatigue behavior of this alloy in both as-built and precipitation-strengthened (aged) conditions has been explored, combined with in-situ neutron diffraction investigation. Findings revealed a substantial cyclic-stress profile and a notable fatigue-life below ±0.50% strain-amplitude, exceeding 10 5 cycles at ±0.30% strain-amplitude. These demonstrate the potential to carry higher payloads with marked engineering-reliability. Residual-stress estimation revealed strain-compatibility between the matrix and L1 2 precipitate, indicating a crack-initiation immune interface. A comparative examination of dislocation character revealed shifting towards pure edge-character in aged alloy indicates precipitates promoted planar-slip during deformation.

36 MATERIALS SCIENCE↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Security Enhancement of Network Constraint Grid-Edge Energy Management System

Network constrained grid edge energy management system (EMS) provides economic solution for active and reactive power dispatch of distributed energy resources (DERs) at the grid edge level. Grid edge EMS ensures secure interconnection of a circuit segment to the distribution system by maintaining grid code requirements (e.g. IEEE 1547–2018). Grid edge EMS is dependent on communication to receive load measurement, which brings a risk of unobservable false data injection attacks (FDIAs). To mitigate the risk, this paper proposes a framework to enhance resilient operation of grid edge EMS by detecting the unobservable FDIAs on loads and replacing them with forecasted values. In this work, a two-step detection algorithm is proposed. In first step, conventional residual based algorithm is deployed. Autoencoder (AE) based data driven mechanism is included in second step to detect the presence of unobservable FDIAs. After ensuring the presence of FDIA, its specific location is detected by checking the maximum residue values till the predefined threshold value is reached. Detected false data injected loads are then replaced with forecasted load values following long-short term memory (LSTM) based forecast to ensure resilient performance of grid edge EMS in the presence of attacks. This proposed security enhancement framework for grid edge EMS is evaluated in IEEE 13 bus system with three integrated DERs. Numerical simulation shows the validation of the proposed framework by reducing voltage violation in real operation of grid edge EMS.

cyber attack detection↗

Weak-lensing Analysis of X-Ray-selected XXL Galaxy Groups and Clusters with Subaru HSC Data

We present a weak-lensing analysis of X-ray galaxy groups and clusters selected from the XMM-XXL survey using the first-year data from the Hyper Suprime-Cam (HSC) Subaru Strategic Program. Our joint weaklensing and X-ray analysis focuses on 136 spectroscopically confirmed X-ray-selected systems at 0.031 6 z 6 1.033 detected in the 25 deg2 XXL-N region, which largely overlaps with the HSC-XMM field. With high-quality HSC weak-lensing data, we characterize the mass distributions of individual clusters and establish the concentration–mass (c–M) relation for the XXL sample, by accounting for selection bias and statistical effects and marginalizing over the remaining mass calibration uncertainty. We find the mass-trend parameter of the c–M relation to be β = -0.07 ± 0.28 and the normalization to be c200 = 4.8 ± 1.0 (stat) ± 0.8 (syst) at M 200 = 1014h -1M and z = 0.3. We find no statistical evidence for redshift evolution. Our weaklensing results are in excellent agreement with dark-matter-only c–M relations calibrated for recent ΛCDM cosmologies. The level of intrinsic scatter in c200 is constrained as σ(ln c 200 ) < 24% (99.7% CL), which is smaller than predicted for the full population of ΛCDM halos. This is likely caused in part by the X-ray selection bias in terms of the cool-core or relaxation state. We determine the temperature–mass (TX–M 500 ) relation for a subset of 105 XXL clusters that have both measured HSC lensing masses and X-ray temperatures. The resulting TX–M 500 relation is consistent with the self-similar prediction. Our TX–M 500 relation agrees with the XXL DR1 results at group scales but has a slightly steeper mass trend, implying a smaller mass scale in the cluster regime. The overall offset in the TX–M 500 relation is at the ~ 1.5σ level, corresponding to a mean mass offset of (34 ± 20)%. We also provide bias-corrected, weak-lensing-calibrated M 200 and M 500 mass estimates of individual XXL clusters based on their measured X-ray temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Enabling probabilistic learning on manifolds through double diffusion maps

Here, we present a generative learning framework for probabilistic sampling that extends Probabilistic Learning on Manifolds (PLoM), which is designed to generate statistically consistent realizations of a random vector in a finite-dimensional Euclidean space, informed by a (representative) set of observations. In its original form, PLoM constructs a reduced-order probabilistic model by combining three main components: (a) kernel density estimation to approximate the underlying probability measure, (b) Diffusion Maps to characterize the manifold of the data, and (c) a reduced-order Itô Stochastic Differential Equation (ISDE) to sample from the learned distribution. However, its sampling dynamics are posed in the ambient space and the retained number of reduced coordinates is chosen by projection-reconstruction error. In practice, this often (i) requires more coordinates than the data’s intrinsic dimension to achieve stable sampling and (ii) lacks a smooth, basis-independent lifting back to the data domain; moreover, standard Diffusion Maps emphasize harmonic eigenfunctions and can miss non-harmonic latent structure. We address these limitations by decoupling geometry learning from sampling: a first Diffusion Maps pass identifies non-harmonic coordinates on which we formulate a full-order ISDE directly in the latent space, while Double Diffusion Maps captures multiscale geometric features and Geometric Harmonics (GH) learns a smooth lifting map to the ambient variables that is independent of the particular diffusion basis. This hybrid design preserves the system’s dynamical richness with a compact geometric representation and enables principled out-of-sample inference. The effectiveness and robustness of the proposed method are illustrated through two numerical studies: one based on data generated from two-dimensional Hermite polynomial functions and another based on high-fidelity simulations of a detonation wave in a reactive flow.

Double diffusion maps↗

Evaluation of UKESM aerosol size and composition using ATom measurements indicates missing marine aerosol formation mechanisms

Atmospheric aerosols influence climate through their interactions with radiation and clouds, yet large uncertainties remain in their simulation by global models. This study evaluates the United Kingdom Earth System Model version 1.1 (UKESM1.1) using global-scale aircraft observations from the Atmospheric Tomography (ATom) mission, focusing on aerosol lifecycle processes in the remote marine atmosphere. We assess model performance in simulating aerosol precursor vapours, number size distributions, chemical composition, and environmental conditions. Several process improvements are tested, including sulfuric acid-ammonia nucleation, ammonium nitrate scheme, methanesulfonic acid condensation, and low-temperature isoprene-derived secondary organic aerosol formation. Model biases differ significantly between the upper troposphere (UT) and the marine boundary layer (MBL). In the UT, UKESM1.1 overestimates nucleation and Aitken mode particles while underestimating accumulation mode, indicating insufficient growth. In the MBL, the model overestimates primary aerosols (e.g. seasalt) and precursor gases but underestimates nucleation and Aitken mode particles, even after incorporating updated nucleation and ammonium nitrate scheme. The persistence of low aerosol number concentrations, despite overestimated precursors, suggests missing formation pathways likely involving other species such as iodine, amines, and organic vapours. These limitations result in an unbalanced cloud condensation nuclei budget that over-relies on primary emissions. Sensitivity tests reveal that model outputs are strongly influenced by dimethyl sulfide emissions and vapour condensation schemes. Our results highlight the need for future model development to prioritise mechanistic representation of currently missing aerosol sources, rather than relying on empirical tuning, to improve aerosol-climate interaction estimates.

He, Xu-Cheng [Univ. of Cambridge (United Kingdom);↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast magnetic response in gigahertz-band for columnar-structured Fe nanoparticle assembly

High density Fe-based ferromagnetic nanoparticle (NP) assembly is expected to have unique magnetic properties, such as superferromagnetism and super-spin-glass, different from magnetically isolated NP systems due to strong dipole interactions among the NPs. A high dipole interaction field, H{sub dip}, of ∼3.5 kOe can result in a high effective internal field to the magnetic moment of the NP, expecting for ultra-fast magnetic response, that is, a high magnetic resonance frequency, f{sub r}, of ∼10 GHz. However, for a simply molded Fe NP assembly, a low f{sub r} was observed due to inhomogeneous distribution of the internal field, implying the necessity of a unidirectional state of H{sub dip} for higher f{sub r}. In this study, we fabricated a columnar Fe NP assembly for realizing the unidirectional state of H{sub dip} by applying our uniquely developed external field-induced agglomeration method for monodispersed Fe NPs (13 nm in average size) as a function of the field (0–30 kOe) and volume fraction of the Fe NPs (0.5%–51%) in a polymer matrix with dimensions of 4 mm × 4 mm × 0.7 mm{sup t}. A columnar-structured Fe NP assembly was successfully achieved along an in-plane direction (defined as the x-axis) under optimized conditions. From static magnetization curves, induced uniaxial magnetic anisotropy was observed according to the shape of the columnar structure of the Fe NP assembly, where easy and hard axes of magnetization were realized along the parallel (x-axis) and normal directions (in-plane y-axis and z-axis in the thickness direction) to the external field during the process, respectively. Interestingly, this fabricated columnar-structured Fe NP assembly exhibited very high f{sub r} in the range from 3 to 11 GHz judging from the complex susceptibility spectra obtained. The f{sub r} values were well-scaled by a modified Snoek's-limit-law using demagnetization factors quantitatively estimated from the static magnetization curves. Thus, shape-induced anisotropy originating from the unidirectional state of H{sub dip} in the columnar structure of the Fe NP assembly plays an important role for high frequency magnetic response in the GHz-band.

36 MATERIALS SCIENCE↗

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗