Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Analysis of electrolyte imbibition through lithium-ion battery electrodes

A quantitative measurement of wettability between the porous electrode and the electrolyte in lithium-ion batteries can greatly improve our understanding of wetting behavior. Although the wetting balance method is widely used to measure the electrolyte transport rate in the porous electrodes, it suffers from several drawbacks and has limited accuracy. We here presented a combined experimental and theoretical investigation of the dynamics of electrolyte imbibition through electrodes. We suggested a novel method to accurately measure the electrolyte imbibition rate. Excellent agreement between the experimental data and the developed analytical model is obtained. The coefficient of penetrance (COP) and the solid permeability coefficient (SPC) are identified as important parameters, i.e., the electrolyte with higher COP value wets faster into an electrode, whereas for an electrolyte, the electrode with higher SPC value is more amenable to be impregnated. The effect of electrolyte salt concentration and electrolyte solvent has been studied in detail. The result implies that increasing salt concentration adversely influences electrolyte wetting rate, whereas switching from EC-DEC system to EC-EMC system improves electrolyte wetting rate. Moreover, for the electrolytes tested in this study, the imbibition into the uncalendered graphite anode is much faster than that into the uncalendered NMC532 cathode.

25 ENERGY STORAGE↗

Control of the Plasma-Material Interface for Long Pulse Optimization in the Experimental Advanced Superconducting Tokamak (EAST) (Final Report)

This project involved a collaborative effort, led by Dr. Rajesh Maingi of Princeton Plasma Physics Laboratory, to understand and control the plasma-material interface to improve long pulse discharge control and performance in the EAST devices. The focus is on long pulse recycling control and optimization, which can be challenging because of their broad range of materials used for plasma-facing components (PFC) and wall conditioning techniques. The purpose of the EAST device is to demonstrate long-pulse, stable, high performance plasma operation, providing a test-bed for key physics and technology issues for next step devices. As part of these tests, EAST has deployed carbon for the lower divertor PFC, tungsten for the upper divertor, and molybdenum for the main wall. In addition wall coatings are deployed for long pulse recycling control: lithium (Li) via several delivery tools, boronization, and recently also siliconization; for example, in 2013, a layer of SiC was deposited on all of the graphite tiles. Oxygen is also present at trace levels, making for a complex mix of materials and plasma-materials interactions (PMI). This mix of materials and the limited durability of wall coatings, coupled to partially optimized cryo-pumping, lead to evolution of the recycling off the PFCs, which restricts the duration of stationary, high performance, long pulse discharges. Comparing the wall conditioning techniques, Li enables the highest energy confinement and lowest recycling for the longest duration, while also suppressing ELMs in certain discharges. More specifically, research activities at the University of Tennessee focused on heat flux profile measurements in EAST, modeling the surface response, including the bonding energetics and chemical interactions between Li with carbon, tungsten, hydrogen and impurities, in addition to post situ experimental characterization and analysis of the divertor plasma facing components in EAST. This final report describes the overall progress within each of these tasks at the University of Tennessee within the project.

36 MATERIALS SCIENCE↗

Water vapor oxidation behaviors of nuclear graphite IG-110 for a postulated accident scenario in high temperature gas-cooled reactors

Water leakage in accidental conditions of high temperature gas-cooled reactors is one of the most critical problems that can compromise the integrity of different nuclear components. In this study, oxidation behaviors of nuclear graphite IG-110 in water ingress accidental conditions were investigated. Mass loss and oxidation rates were evaluated after oxidation tests at temperatures up to 1400 °C in an Ar-20 vol% H 2 O mixed atmosphere. The activation energy decreased from 318.6 to 148.9 kJ/mol with temperature, indicating two different oxidation regimes. The cross-sections of the oxidized samples were systematically characterized. The corresponding logarithmic porosity profiles showed a temperature dependency. Pore formation moved toward near-surface regions with increasing temperature and preferential binder oxidation, with filler particle degradation. Furthermore, oxidant concentration profiles and oxidation depths were estimated using a theoretical model and compared with the experimental results. This work provides important benchmark data and safety analysis guidance for the accident scenario in high temperature gas-cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical Fier Based System for Multiple Thermophysical Properties for Glove Box, Hot Cell and In-Pile Application

Thermal diffusivity of materials is of interest in nuclear applications at temperatures in excess of 2000°C. Commercial laser flash apparatus (LFA) that heats samples with a furnace typically do not reach these elevated temperatures nor are they easily adapted to a glove-box or hot cell environment. In this research, we performed work on an experimental technique using single laser surface heating, i.e. heating the disk sample only at its front surface with the continuous wave (CW) laser, to allow measurement of thermal diffusivity at very high temperatures within a small chamber. Thermal diffusivity is measured using a separate pulsed laser on the front side and IR detector on the rear side. The new way of heating provides easy operation in comparison to other heating methods. The measurement of sample reference temperature is needed for the measured thermal diffusivity. A theoretical model was developed to describe transient heat transfer across the sample due to the laser pulse, starting from the steady state temperature of the sample heated by the CW laser. The experimental setup was established with a 500W CW laser and maximum 50 Joule pulse laser irradiated at the front surface of the sample. The induced temperature rise at the rear surface, along with the steady-state temperature at the front surface, was recorded for the determination of thermal diffusivity and the sample temperature. Three samples were tested in vacuum over a wide temperature range of 500°C to 2100°C, including graphite, Inconel 600 and tungsten. The latter two samples were coated with sprayed graphite on their front surfaces in order to achieve surface absorption/emission needs, i.e. high absorptivity of the front surface against relatively low emissivity of the rear surface. Thermal diffusivity of graphite determined by our system are within a 5% difference of the commercial LFA data at temperatures below 1300°C and agree well with its trend at higher temperatures. Good agreement would also exist for Inconel 600 and tungsten. Despite large uncertainty of measuringthe sample temperature, the uncertainties of thermal diffusivity are less than 6% for all samples at elevated temperatures. The results indicate that single laser surface heating could be convenient and practical for the application of the LFA measurements without extra uncertainty, as temperature dependence of thermal diffusivity is usually negligible in the sample. Moreover, it is concluded that unequal surface treatment, i.e., high absorption on the front side and low emission on the rear side, greatly improves the measurement in serval aspects: less power requirement of the CW laser, less uncertainty of measured thermal diffusivity, and more uniform temperature distribution in the sample. The result of this research can be used as a general guideline for the design of this type of measurement system for nuclear applications. It can also be used directly to design and build a system similar to the one implemented in this project.

36 MATERIALS SCIENCE↗

Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions between the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very effective in removing decay heat. By removing the limit on the decay heat removal capability due to the limited available surface area as in a RVACS, the reactor power and power density can be significantly increased, without losing the passive heat removal feature. This paper will introduce the concept of using DRACS to enhance VHTR passive safety and economics. Three design options will be discussed, depending on the cooling pipe locations. Analysis results from a lumped volume based model and CFD simulations will be presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A tale of three galaxies: Deciphering THE infrared emission of the spectroscopically anomalous galaxies IRAS F10398+1455, IRAS F21013–0739, and SDSS J0808+3948

The Spitzer/Infrared Spectrograph spectra of three spectroscopically anomalous galaxies (IRAS F10398+1455, IRAS F21013–0739, and SDSS J0808+3948) are modeled in terms of a mixture of warm and cold silicate dust, and warm and cold carbon dust. Their unique infrared (IR) emission spectra are characterized by a steep ∼5–8 μm emission continuum, strong emission bands from polycyclic aromatic hydrocarbon (PAH) molecules, and prominent silicate emission. The steep ∼5–8 μm emission continuum and strong PAH emission features suggest the dominance of starbursts, while the silicate emission is indicative of significant heating from active galactic nuclei (AGNs). With warm and cold silicate dust of various compositions (“astronomical silicate,” amorphous olivine, or amorphous pyroxene) combined with warm and cold carbon dust (amorphous carbon, or graphite), we are able to closely reproduce the observed IR emission of these galaxies. We find that the dust temperature is the primary cause in regulating the steep ∼5–8 μm continuum and silicate emission, insensitive to the exact silicate or carbon dust mineralogy and grain size a as long as a≲1 μm. More specifically, the temperature of the ∼5–8 μm continuum emitter (which is essentially carbon dust) of these galaxies is ∼250–400 K, much lower than that of typical quasars, which is ∼640 K. Moreover, it appears that larger dust grains are preferred in quasars. The lower dust temperature and smaller grain sizes inferred for these three galaxies compared with that of quasars could be due to the fact that they may harbor a young/weak AGNs that is not maturely developed yet.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Testing Options for the NTR at the INL (Final Report)

One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issues in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $\$$3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $\$$250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]↗

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

High-temperature gas-cooled reactors (HTGRs) are a relatively mature advanced reactor concept that are of interest to industry and government for near-term deployment. These systems feature passive safety through low power density, coated particle fuels, and large graphite volumes that lead to slow heatup. In loss of flow transients, cooldown is achieved through conduction and radiation heat transfer. In prismatic block-type reactors, such as the mHTGR-350, the presence of coolant holes and fuel compacts alters the flow of heat through the blocks. To capture this effect in systems codes like RELAP5-3D, relationships for effective thermal conductivity (ETC) must be used to appropriately degrade the thermal conductivity. This work presents an assessment of the impact of ETC on performance of block-type gas-cooled reactors in a pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients. Models for PCC and DCC with bulk material thermal conductivity and ETC were run for both the mHTGR-350 and the High-Temperature Test Facility (HTTF) to determine the impact of ETC on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]↗

Molecular dynamics simulations reveal that water diffusion between graphene oxide layers is slow

Membranes made of stacked layers of graphene oxide (GO) hold the tantalizing promise of revolutionizing desalination and water filtration if selective transport of molecules can be controlled. We present the findings of a molecular dynamics simulation study of water intercalated between GO layers that have a C/O ratio of 4. We simulated a range of hydration levels from 1 wt.% to 23.3 wt.% water. The interlayer spacing increased upon hydration from 0.8 nm to 1.1 nm. We also synthesized GO membranes that showed an increase in spacing from about 0.7 nm to 0.8 nm and an increase in mass of about 14% on hydration. Water diffusion through GO layers is an order of magnitude slower than that in bulk water, because of strong hydrogen bonded interactions. Most of the water molecules are bound to OH groups even at the highest hydration level. We observed large water clusters that could span graphitic regions, oxidized regions and holes that have been experimentally observed in GO. As a result, slow interlayer diffusion can be consistent with experimentally observed water transport in GO if holes lead to a shorter path length than previously assumed and sorption serves as a key rate-limiting step.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-IPR C{sub 60} solids

Films comprising predominantly novel isomers of C{sub 60} [=C{sub 60}(nIPR)] have been generated by low energy ion beam deposition of vibronically excited C{sub 60}{sup +} onto graphite followed by selective sublimation of C{sub 60}(I{sub h}) from the deposited isomer mixture. The incident ions were generated by electron impact ionization/fragmentation of sublimed C{sub 70}. Images of the C{sub 60}(nIPR) films obtained by applying atomic force microscopy show aggregates, which we attribute to covalently interlinked C{sub 60}(nIPR) units. The covalent bonds are inferred from the significantly higher thermal stability of the C{sub 60}(nIPR) films compared to the C{sub 60}(I{sub h}) van der Waals solid-as measured by thermal desorption with mass spectrometric detection of the C{sub 60} mass channel (the only desorbable species). In contrast to the characteristic doublet structure of the occupied valence band in the ultraviolet photoelectron spectrum of pure C{sub 60}(I{sub h}), the valence band of C{sub 60}(nIPR) films exhibits a triplet feature with the additional peak occurring at a binding energy of {approx}2.6 eV. This is an indicator of the electronic modifications induced by intermolecular bonding. C{sub 60}(nIPR) films exhibit a narrower band gap than found for C{sub 60}(I{sub h}). They also have significantly different chemical reactivity toward incorporation of thermal energy deuterium atoms. In order to model the experimental photoelectron spectra, various covalently linked oligomers of {sup 1809}C{sub 60}(C{sub 2v}), the second most stable conventional 60-atom fullerene cage, were calculated by means of the density functional theory. These spectral predictions together with analogous previous observations on related fullerene solids such as C{sub 58} lead us to infer that C{sub 60}(nIPR) films consist of fullerene cage isomers containing one or more adjacent pentagon pairs, which mediate covalent cage-cage interconnection.

36 MATERIALS SCIENCE↗

Enhancement of Thermal Conductivity of Bentonite Buffer Materials with Copper Wires/Meshes for High-Level Radioactive Waste Disposal

In high-level radioactive waste disposal, a heat-generating waste canister is generally encased with a layer of bentonite-based buffer material acting as an engineered barrier to limit water percolation and radionuclide release. The low thermal conductivity of bentonite (~0.5 W/m∙K) combined with a high thermal loading waste package may result in a high surface temperature on the package that can potentially impact the structural integrity of the package itself as well as the surrounding buffer material. We show in this paper that the thermal conductivity of bentonite can be effectively enhanced by embedding copper wires/meshes across the buffer layer to form fully connected high heat conduction pathways. A simple calculation based on Rayleigh’s model shows that a required thermal conductivity of 5 W/m∙K for effective heat dissipation can be achieved simply by adding ~1 vol % of copper wires/meshes into bentonite. As a result, the peak surface temperature on a large waste package such as a dual-purpose canister can be reduced by up to 300°C, leading to a significant reduction in the surface storage time for waste cooling and therefore the overall cost for direct disposal of such waste packages. Because of the ensured full thermal percolation across the buffer layer, copper wires/meshes turn out to be much more effective than any other materials currently suggested (such as graphene or graphite) in enhancing the thermal conductivity of buffer material. Furthermore, the embedded copper wires/meshes can help reinforce the mechanical strength of the buffer material, thus preventing the material from a potential erosion by a possible intrusion of dilute groundwater.

36 MATERIALS SCIENCE↗

Determination of positive anode sheath in anodic carbon arc for synthesis of nanomaterials

In the atmospheric pressure anodic carbon arc, ablation of the anode serves as a feedstock of carbon for production of nanomaterials. It is known that the ablation of the graphite anode in this arc can have two distinctive modes with low and high ablation rates. The transition between these modes is governed by the power deposition at the arc attachment to the anode and depends on the gap between the anode and the cathode electrodes. Probe measurements combined with optical emission spectroscopy are used to analyze the voltage drop between the arc electrodes. These measurements corroborated previous predictions of a positive anode sheath (i.e. electron attracting sheath) in this arc, which appears in both low and high ablation modes. However, the positive anode sheath was determined to be ~3–8 V, significantly larger than ~0.5 V predicted by previous models. Thus, there are apparently other physical mechanisms not considered by these models that force the anode sheath to be electron attracting in both ablation regimes. Another key result is a relatively low electron temperature (~0.6 eV) obtained from OES using a collisional radiative model. This result partially explains a higher arc voltage (~20 V) required to sustain the arc current of 50–70 A than predicted by existing simulations of this discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Characterization of Dendrite Deposition and Growth in Li-Surface by Electrochemical Impedance Spectroscopy

The evolution of dendrite formation is characterized by DC and AC electrochemical techniques. Interfacial mechanisms for lithium deposition are described and quantified by electrochemical impedance spectroscopy (EIS) between a lithium electrode and a graphite electrode. The initiation and growth of dendrites in the lithium surface due to the cathodic polarization conditions following anodic dissolution emulate long term cycling process occurring in the lithium electrodes. The dendrite initiation at the lithium/organic electrolyte interface is proposed to be performed through a combination of layering and interfacial reactions during different cathodic conditions. The growth is proposed to be performed by surface geometrical deposition. In this work, we use EIS in galvanostatic mode to assess the initiation and growth stages of dendrites by the accumulation of precipitates formed under different current conditions. The lithium/organic solvent experimental system using frequency domain techniques is validated by the theoretical approach using a deterministic model that accounts for the faradaic processes at the interface assuming a coverage fraction of the electrodic surface affected by the dendritic growth. (C) 2015 The Electrochemical Society. All rights reserved.

Hernandez-Maya, R↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Study of Air Ingress Across the Duct During the Accident Conditions

The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bypass flow computations on the LOFA transient in a VHTR

Bypass flow in the prismatic gas-cooled very high temperature reactor (VHTR) is not intentionally designed to occur, but is present in the gaps between graphite blocks. Previous studies of the bypass flow in the core indicated that the cooling provided by flow in the bypass gaps had a significant effect on temperature and flow distributions for normal operating conditions. However, the flow and heat transports in the core are changed significantly after a Loss of Flow Accident (LOFA). This study aims to study the effect and role of the bypass flow after a LOFA in terms of the temperature and flow distributions and for the heat transport out of the core by natural convection of the coolant for a 1/12 symmetric section of the active core which is composed of images and mirror images of two sub-region models. The two sub-region models, 9 x 1/12 and 15 x 1/12 symmetric sectors of the active core, are employed as the CFD flow models using computational grid systems of 70.2 million and 117 million nodes, respectively. It is concluded that the effect of bypass flow is significant for the initial conditions and the beginning of LOFA, but the bypass flow has little effect after a long period of time in the transient computation of natural circulation.

99 GENERAL AND MISCELLANEOUS↗