Generation of a controllable TNSA deuteron beam using deuterated metal targets

This study investigated the feasibility of using deuterated titanium targets for the generation of a target normal sheath acceleration (TNSA) deuteron beam. Commercial 25-μm-thick titanium foil was cut into 500 x 500-μm 2 squares and subsequently deuterated using different approaches. The spectra and total yields of all emitted ions were measured using a Thomson parabola ion spectrometer. It was found that a 24-h exposure to 1 atm of D 2 gas at 400°C is the most-efficient deuteration method, producing yields in the mid-10 11 deuterons per shot. The deuteron energy spectra changed from an exponential shape at low ion yields to exponentially modified Gaussians at higher yields. Simulations suggest that this effect is due to increased Coulomb interactions between the ions, which suppress the low energies. Separate campaigns will utilize the presented approach to produce a TNSA triton beam. Furthermore, two such targets will be used in a pitcher/catcher configuration to study the tritium–tritium reaction T(t, 2n)α.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotopic carbon targets

Neutron-rich isotopic 14 C targets are of interest to the nuclear physics community and would be in high demand at any thickness. Applied Nanotech, Inc. (ANI) has developed freestanding nat C and 13 C carbon foils fabricated using a drawdown printing technique. Isotopic enriched 13 C targets are produced at ANI, with the 14 C targets to be fabricated at Argonne National Laboratory (ANL) using stock material available at Argonne. The 14 C target material is nominally enriched to ~73% 14 C and will contain 2.2% organic binder. The fabrication process is highly material-efficient and can be used to produce targets that are difficult to fabricate by other methods. Finally, to be developed, 12 C ( 13 C-depleted natural carbon) which could also be used in accelerators for target applications.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold-tantalum alloy films deposited by high-density-plasma magnetron sputtering

Gold-tantalum alloy films are of interest for biomedical and magnetically-assisted inertial confinement fusion applications. Here, we systematically study the effects of substrate tilt (0°–80°) and negative substrate bias (0–100 V) on properties of ≲3-μm-thick films deposited by high-power impulse magnetron sputtering (HiPIMS) from a Au–Ta alloy target (with 80 at. % of Ta). Results reveal that, for all the substrate bias values studied, an increase in substrate tilt leads to a monotonic decrease in film thickness, density, residual compressive stress, and electrical conductivity. Larger substrate bias favors the formation of a body-centered cubic phase, with films exhibiting lower column tilt and higher density, electrical conductivity, and residual compressive stress. Furthermore, these changes are attributed to metal atom ionization effects, based on the lack of correlation with distributions of landing energies and incident angles of depositing species as calculated by Monte Carlo simulations of ballistic collisions and gas phase atomic transport. By varying substrate tilt and bias in HiPIMS deposition, properties of Au–Ta alloy films can be controlled in a very wide range, including residual stress from –2 to +0.5 GPa, density from 12 to 17 g/cm 3 , and the electrical resistivity from 50 to 4500 μΩ cm, enabling optimum deposition conditions to be selected for specific applications.

36 MATERIALS SCIENCE↗

Development of New Magnetron Sputter Deposition Processes for Laser Target Fabrication

Magnetron sputter deposition is an enabling technology for laser target fabrication. Solutions are readily available for the deposition of most sub-micron-thick elemental films on planar substrates. However, major challenges still remain for the development of robust deposition processes in regimes of ultrathick (over ~10 μm) coatings and nonplanar substrates. These challenging deposition regimes are directly relevant to laser target applications, including both sphero-cylindrical hohlraums and spherical ablators for inertial confinement fusion (ICF) targets. Understanding underlying physical mechanisms for a specific material system is crucial for process development, given the overall complexity of the deposition process, its nonlinear dependence on deposition parameters, and a very large process space, often precluding conventional process optimization approaches. Here, we describe our approach to developing new deposition processes and give practical advice with examples of new results from our ongoing studies of glassy boron carbide ceramics for next-generation ICF ablators and nonequilibrium gold-tantalum alloys for hohlraums for magnetized ICF schemes. Emphasis is given to two major challenges of ultrathick coatings related to achieving process stability and reducing residual stress.

36 MATERIALS SCIENCE↗

THE HERSCHEL DIGIT SURVEY OF WEAK-LINE T TAURI STARS: IMPLICATIONS FOR DISK EVOLUTION AND DISSIPATION

As part of the 'Dust, Ice, and Gas In Time (DIGIT)' Herschel Open Time Key Program, we present Herschel photometry (at 70, 160, 250, 350, and 500 {mu}m) of 31 weak-line T Tauri star (WTTS) candidates in order to investigate the evolutionary status of their circumstellar disks. Of the stars in our sample, 13 had circumstellar disks previously known from infrared observations at shorter wavelengths, while 18 of them had no previous evidence for a disk. We detect a total of 15 disks as all previously known disks are detected at one or more Herschel wavelengths and two additional disks are identified for the first time. The spectral energy distributions (SEDs) of our targets seem to trace the dissipation of the primordial disk and the transition to the debris disk regime. Of the 15 disks, 7 appear to be optically thick primordial disks, including 2 objects with SEDs indistinguishable from those of typical Classical T Tauri stars, 4 objects that have significant deficit of excess emission at all IR wavelengths, and 1 'pre-transitional' object with a known gap in the disk. Despite their previous WTTS classification, we find that the seven targets in our sample with optically thick disks show evidence for accretion. The remaining eight disks have weaker IR excesses similar to those of optically thin debris disks. Six of them are warm and show significant 24 {mu}m Spitzer excesses, while the last two are newly identified cold debris-like disks with photospheric 24 {mu}m fluxes, but significant excess emission at longer wavelengths. The Herschel photometry also places strong constraints on the non-detections, where systems with F {sub 70}/F {sub 70,*} {approx}> 5-15 and L {sub disk}/L {sub *} {approx}> 10{sup -3} to 10{sup -4} can be ruled out. We present preliminary models for both the optically thick and optically thin disks and discuss our results in the context of the evolution and dissipation of circumstellar disks.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian Edge radiosurgery 6DOF-based system, can perform 2D/3D image registration with high accuracy for target localization in image-guided stereotactic radiosurgery. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

Mass and Size Frequency Distribution of the Impact Debris from Disruption of Chondritic Meteorites

Since direct observation of the collision of asteroids in space is not always convenient for earthbound observers, we have undertaken simulations of these collisions using the NASA Ames Vertical Gun Range (AVGR). To simulate the collision of asteroids in space, and aluminum projectiles with velocities ranging from approx.1 to approx.6 km/sec were fired at 70g to approx.200 g fragments of chondritic meteorites. The target meteorite was placed in an evacuated chamber at the AVGR. Detectors, usually four, were set up around the target meteorite. These detectors consisted of aerogel and aluminum foil of varying thickness. The aerogel's purpose was to catch debris after the collision, and the aluminum foil.s purpose was to show the size of the debris particles through the size of the holes in the aluminum foil. Outside the chamber, a camera was set up to record high-speed film of the collision. This camera recorded at either 500 frames per second or 1000 frames per second. Three different types of targets were used for these tests. The first were actual meteorites, which varied in mineralogical composition, density, and porosity. The second type of target was a Hawaiian basalt, consisting of olivine phenocrysts in a porous matrix, which we thought might be similar to the chondritic meteorites, thus providing data for comparison. The final type was made out of Styrofoam. The Styrofoam was thought to simulate very low-density asteroids and comets.

VanVeghten, T. W.↗

Heavy-ion fragmentation studies in thick water absorbers

Proposed long-term space missions could expose crewmembers to significant fluxes of galactic cosmic radiation (GCR) particles and secondary particles created from nuclear collisions. An assessment of radiobiological risks is dependent upon an accurate description of the charged-particle radiation field inside the human body. As shield thickness increases and the incident ions are slowed, the production of secondary particles contributes an increasingly significant fraction of the total dose until eventually secondary particles become more important than the primary particles. The nuclear mean free path of the GCR ions (which usually have nuclear charge between 1 (protons) and 26 (iron), both inclusive) are comparable with thicknesses typical of spacecraft structures and the human body. Collisions in these media will create projectile and target fragments with charge less than that of the primary particle, and each interaction event can have a multiplicity of more than one emerging interaction product. Projectile fragments usually continue on with very nearly the velocity of the primary ion (the so-called straightahead approximation). Having sufficient energy, the fragments may collide with atomic nuclei in thick shields and create a second generation of fragments, and so on. Target fragments are emitted from a struck nucleus, usually with much lower energy than projectile fragments and nearly isotropically in the rest frame of the absorbing medium. The resulting spectrum of particles and their energy loss rates will be very different from that in the unshielded environment, will determine the radiobiological impact on exposed living tissues -- whether in space or in ground-based radiobiology experiments -- and will play an important role in radiation effects on microelectronics.

Shavers, M. R.↗

WEAK HARD X-RAY EMISSION FROM TWO BROAD ABSORPTION LINE QUASARS OBSERVED WITH NuSTAR: COMPTON-THICK ABSORPTION OR INTRINSIC X-RAY WEAKNESS?

We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain Almost-Equal-To 400-600 hard X-ray ({approx}> 10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed (N{sub H} {approx}< 10{sup 24} cm{sup -2}). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be N{sub H} Almost-Equal-To 7 Multiplication-Sign 10{sup 24} cm{sup -2} if the weak hard X-ray emission is caused by obscuration from the shielding gas. We discuss a few possibilities for how PG 1004+130 could have Compton-thick shielding gas without strong Fe K{alpha} line emission; dilution from jet-linked X-ray emission is one likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place statistical constraints upon the fraction of intrinsically X-ray weak BAL quasars; this fraction is likely 17%-40%.

79 ASTRONOMY AND ASTROPHYSICS↗

Weak Hard X-Ray Emission from Two Broad Absorption Line Quasars Observed with NuStar: Compton-Thick Absorption or Intrinsic X-Ray Weakness?

We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain approx. or equal to 400-600 hard X-ray (is greater than or equal to 10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed N(sub H) is less than or equal to 10(exp24) cm(exp-2). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be N(sub H) 7 × 10(exp 24) cm(exp-2) if the weak hard X-ray emission is caused by obscuration from the shielding gas. We discuss a few possibilities for how PG 1004+130 could have Compton-thick shielding gas without strong Fe Kα line emission; dilution from jet-linked X-ray emission is one likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place statistical constraints upon the fraction of intrinsically X-ray weak BAL quasars; this fraction is likely 17%-40%.

nuclei↗

SU-E-T-461: Validation of Planning Algorithms in Dynamic Conformal Arc in IPlan Using ArcCHECK and 3DVH

Purpose: To study the effect of limited angular resolution of pencil beam calculation (PBC) on dynamic conformal arc plan (DCAP) in iPlan (BrainLab) using the ArcCHECK sytem and 3DVH software (Sun Nuclear Corporation). Methods: Four DCAPs were generated in iPlan RT Dose 4.5 treatment planning system on the ArcCHECK cylindrical phantom with central planning target volume (PTV). A cylindrical shell structure (SHELL) 2.85cm from phantom surface and 1.5 mm thickness was created to simulate the ArcCHECK diode array. Planned doses were calculated using both Monte Carlo calculation (MCC) and PBC algorithms, and exported to 3DVH software for global and target based comparisons using the 3Dgamma index. Four additional DCAPs were created and calculated on patient CT images and mapped onto the ArcCHECK phantom for measurement using a Varian TrueBeam STx. The measurements were compared against both MC and PB calculation using gamma index analysis. Results: For the ArcCHECK phantom, the dose distribution agreement quantified with 3D-gamma index is better (average-gamma (<γ>)=99.9%vs.79.1% and 96.8%vs45.7%, p=0.0294, 0.0286 for gamma (2mm,2%) and (1mm,1%) criteria respectively using Mann-Whitney U test) in the PTV than in the SHELL. The measurements show better agreement with MCC than the PB (<γ>=100%vs.86.7%, 99.6%vs.72.3%, 85.5%vs.50.8%, p=0.021, 0.026, 0.029 for gamma (3mm,3%), (2mm,2%) and (1mm,1%) criteria using Mann-Whitney U test respectively). The effect due to limited (10 degree) angular resolution of the PBC was observed, and it can be one of the possible reasons for poor agreement between measurement and PB calculation. Conclusion: The PBC of iPlan shows poor peripheral dose calculation accuracy for dynamic conformal arc plans due to limited angular resolution, but it performs well in the area close to target volume without considering heterogeneity. Since the user cannot change the 10 degree angular resolution of PBC, MCC is more appropriate for dynamic conformal arc plans.

60 APPLIED LIFE SCIENCES↗

Target Optimization Study: Tolerance Sensitivity

A Work Package was initiated to investigate the potential for target optimization. The current design is made up of 82 disks 0.5 mm thick spaced 0.25 mm apart for helium coolant flow. This disk thickness and gap width are a result of continual increases is beam power and hence volumetric heating rate. Thickening the disks would mean higher disk temperatures, but this would be weighed against the prospect of fewer, thicker disks and wider coolant gap spaces, and the relaxed tolerances that would result. Fabrication of the target holder would be easier and less expensive, and target assembly would also be easier.

43 PARTICLE ACCELERATORS↗

Two Complementary Strategies for New Physics Searches at Lepton Colliders

In this thesis I present two complementary strategies for probing beyond-the-Standard Model physics using data collected in e + e - collisions at lepton colliders. One strategy involves searching for effects at low energy mediated by new particles at the TeV mass scale, at which new physics is expected to manifest. Several new physics scenarios, including Supersymmetry and models with leptoquarks or compositeness, may lead to observable rates for charged lepton-flavor violating processes, which are forbidden in the Standard Model. I present a search for lepton-flavor violating decays of the Υ(3S) using data collected with the BABAR detector. This study establishes the 90% confidence level upper limits BF(Υ(3S) → eτ) < 5.0 x 10 -6 and BF(Υ(3S) → μτ) < 4.1 x 10 -6 which are used to place constraints on new physics contributing to lepton-flavor violation at the TeV mass scale. An alternative strategy is to increase the collision energy above the threshold for new particles and produce them directly. I discuss research and development efforts aimed at producing a vertex tracker which achieves the physics performance required of a high energy lepton collider. A small-scale vertex tracker prototype is constructed using Silicon sensors of 50 μm thickness and tested using charged particle beams. This tracker achieves the targeted impact parameter resolution of σ LP = (5⊕10 GeV/p T ) as well as a longitudinal vertex resolution of (260 ± 10) μm, which is consistent with the requirements of a TeV-scale lepton collider. This detector research and development effort must be motivated and directed by simulation studies of physics processes. Investigation of a dark matter-motivated Supersymmetry scenario is presented, in which the dark matter is composed of Supersymmetric neutralinos. In this scenario, studies of the e + e - → H 0 A 0 production process allow for precise measurements of the properties of the A 0 Supersymmetric Higgs boson, which improve the achievable precision on the neutralino dark matter candidate relic density to 8%. Comparison between this quantity and the dark matter density determined from cosmological observations will further our understanding of dark matter by allowing us to determine if it is of Supersymmetric origin.

43 PARTICLE ACCELERATORS↗

SU-F-T-570: Comparison of Synthetic Diamond, Microionization Chamber, and Radiochromic Film for Absolute Dosimetry of VMAT Radiosurgery

Purpose: Patient specific quality assurance of stereotactic radiosurgery (SRS) plans is challenging because of small target sizes and high dose gradients. We compared three detectors for dosimetry of VMAT SRS plans. Methods: The dose at the center of seventeen targets was measured using a synthetic diamond detector (2.2 mm diameter, 1 µm thickness), a 0.007 cm{sup 3} ionization chamber, and radiochromic film. Measurements were made in a PMMA phantom in the clinical geometry – all gantry and table angles were delivered as planned. The diamond and chamber positions were offset by 1 cm from the film plane, so the isocenter was shifted accordingly to place the center of the target at the detector of interest. To ensure accurate detector placement, the phantom was positioned using kV images. To account for the shift-induced difference in geometry and differing prescription doses between plans, the measurements were normalized to the expected dose calculated by the treatment planning system. Results: The target sizes ranged from 2.8 mm to 34.8 mm (median 14.8 mm). The mean measurement-to-plan ratios were 1.054, 1.076, and 1.023 for RCF, diamond, and chamber, respectively. The mean difference between the chamber and film was −3.2% and between diamond and film was 2.2%. For targets larger than 15 mm, the mean difference relative to film was −0.8% and 0.1% for chamber and diamond, respectively, whereas for targets smaller than 15 mm, the difference was −5.3% and 4.2% for chamber and diamond, respectively. The difference was significant (p=0.005) using the two-sample Kolmogorov-Smirnov test. Conclusion: The detectors agree for target sizes larger than 15 mm. Relative to film, for smaller targets the diamond detector over-responds, whereas the ionization chamber under-responds. Further work is needed to characterize detector response in modulated SRS fields.

60 APPLIED LIFE SCIENCES↗

Kerfless Silicon Precursor Wafer Formed by Rapid Solidification: October 2009 - March 2010

1366 Direct Wafer technology is an ultra-low-cost, kerfless method of producing crystalline silicon wafers compatible with the existing dominant silicon PV supply chain. By doubling utilization of silicon and simplifying the wafering process and equipment, Direct Wafers will support drastic reductions in wafer cost and enable module manufacturing costs < $1/W. This Pre-Incubator subcontractenabled us to accelerate the critical advances necessary to commercialize the technology by 2012. Starting from a promising concept that was initially demonstrated using a model material, we built custom equipment necessary to validate the process in silicon, then developed sufficient understanding of the underlying physics to successfully fabricate wafers meeting target specifications. Thesewafers, 50 mm x 50 mm x 200 ..mu..m thick, were used to make prototype solar cells via standard industrial processes as the project final deliverable. The demonstrated 10% efficiency is already impressive when compared to most thin films, but still offers considerable room for improvement when compared to typical crystalline silicon solar cells.

14 SOLAR ENERGY↗

SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embedded into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.

60 APPLIED LIFE SCIENCES↗

Non-Rare Earth Magnesium Bumper Beams

Magna will team with the Pacific Northwest National Laboratory (PNNL) to develop Shear Assisted Processing and Extrusion (ShAPE™) of rectangular and multi-zoned extrusion profiles using non-RE Mg. It is envisioned that the ShAPE™ process, developed during this project for non-circular profiles, will serve as the foundation for fabrication of full-scale bumper beams of the future where near net-shapes are extruded directly from castings in a single step, without the need for costly rare earth additives. In this project, the ShAPE™ process will be developed for a rectangular profile measuring 1” x 2” with a 0.06” wall thickness. Successful extrusion of rectangular cross sections is a critical step along the path toward profiles with multiple zones. With the process established for a rectangular profile, the project will then make advancements toward multi-zoned cross sections. A magnesium alloy bumper beam offers a 35% weight savings compared to aluminum alloys and 60% compared to high strength steels. The bumper beam was chosen as the first component to target because the geometry can have a fairly simple 0.6-0.12 inch wall/web thickness, generally compatible with PNNL’s knowledge base and equipment capability surrounding ShAPE™. The bumper component offers commercial value by providing mass reduction in the front of the vehicle along with ride and handling benefit. PNNL has demonstrated the ability to ShAPE™ process non-RE Mg tubing with high strength, ductility and energy absorption. It has been shown that ShAPE™ extruded ZK60 and Mg2Si tubing with 0.30 inch diameter and 0.03 inch wall thickness have similar energy absorption to AA6061-T6. This is due to significant grain refinement, breakdown and dispersion of second phases, and the ability to eliminate anisotropy in compressive/tensile strength by aligning texture 45 degrees to the extrusion axis. Scalability of the ShAPE™ process has been demonstrated in ZK60 by fabricating 2.0 inch diameter tubing with 0.06 and 0.12 inch wall thicknesses having concentricity as tight as 1.3%. These tubes exhibit an ultimate tensile strength of 260-300 MPa and room temperature ductility of >20% parallel, perpendicular and 45 degrees to the extrusion axis. Aluminum bumpers represent approximately 54% of the NA light vehicle market. If the research effort is successful, providing a 30% mass reduction at equal cost relative to aluminum bumpers, it is anticipated that 25% market penetration would be realized over the next 5 year and 50% market share by 2030. 100% of the aluminum automotive bumpers are sourced from the tier network, providing resourcing opportunity based on equal performance, reduced mass and cost equivalent lower than aluminum bumpers. Due to the relatively low vehicle content, magnesium components are currently shredded and 100% recycled with aluminum content in the US, presenting a positive life cycle impact.

42 ENGINEERING↗