Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

H–J–B Equations of Optimal Consumption-Investment and Verification Theorems

We consider a consumption-investment problem on infinite time horizon maximizing discounted expected HARA utility for a general incomplete market model. Based on dynamic programming approach we derive the relevant H–J–B equation and study the existence and uniqueness of the solution to the nonlinear partial differential equation. By using the smooth solution we construct the optimal consumption rate and portfolio strategy and then prove the verification theorems under certain general settings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research and Experiment on the Key Technologies of the Spent Fuel Storage in HTR-PM - 18486

High Temperature Reactor demonstration project of China (HTR-PM) is one of the major national science and technology projects, some key technologies for the design and operation of the demonstration project are formed to research according to the main technology. The spent fuel storage system is one of the main systems of the HTR-PM. In order to solve the technical problems related to the operation of spent fuel, several experiments have been conducted, including: spent fuel loading, getting back, spent fuel canister hoisting, storage well cover hoisting, storage canister drop and so on. In the study process, the test facility has been set up to carry on the operation and the experiment verification to ensure the reliability and safety of the spent fuel storage system. Spent fuel storage system undertakes spent fuel receiving, spent fuel canister transfer, storage, lifting and other functions in HTR-PM, the project research need to solve several major technical problems related to the spent fuel operation, which mainly include: Develop the transportable spent fuel canister for HTR-PM, the canister is corrosion resistance, impact resistance, and is in subcritical condition when loaded with fuel. Develop the spent fuel canister hoister, which could hoist the spent fuel canister safely and reliably. Develop the spent fuel storage well cover hoister, which could hoist the well cover safely and reliably. Study the small probability of the spent fuel canister in extreme condition of canister hoist falling accidents, to ensure the radiation protect safety and residual heat removal safety of the canister in case of the canister drop when lifting. Develop the spent fuel charging device and return device, which could load the spent fuel elements into the spent fuel canister, and could take out the fuel elements from the canister. The key technology and equipment of the spent fuel storage system in HTR-PM would be solved through the research of the project. Project research is very important for the implementation and safe operation of the HTR-PM project. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation

Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose volume histograms (DVHs) for single-shot irradiations of the Gamma Knife (GK) unit were used to investigate the effects of the presence of inhomogeneities on 3D dose distribution. The head phantom was a custom-built 16 cm diameter Plexiglas sphere. Inside the phantom, there is a cubic cutout for inserting the gel vials and another cutout for inserting the inhomogeneities. Following irradiation with the GK unit, the polymer gel phantoms were scanned with a 1.5 T MRI scanner. Comparing the results of measurement in homogeneous and heterogeneous phantoms revealed that inserting inhomogeneities inside the homogeneous phantom did not cause considerable disturbances on dose distribution in irradiation with 8 mm collimator within low isodose levels (<50%), which is essential for the dose sparing of sensitive structures. The results of simulation for homogeneous and inhomogeneous phantoms in irradiation with 18 mm collimator of the GK unit showed 23.24% difference in DVH within 90%-100% relative isodose level and also revealed that a significant part of the target (28.56%) received relative doses higher than the maximum dose, which exceeds the acceptance criterion (5%). Based on these results it is concluded that the presence of inhomogeneities inside the phantom can cause considerable errors in dose calculation within high isodose levels with respect to LGP prediction which assumes that the target is a homogeneous material. Moreover, it is demonstrated that the applied MC code is an accurate and stand-alone tool for 3D evaluation of dose distribution in irradiation with the GK unit, which can provide important, 3D plan evaluation criteria used in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Galaxy populations in massive galaxy clusters to $z$ = 1.1: Color distribution, concentration, halo occupation number and red sequence fraction

We study the galaxy populations in 74 Sunyaev–Zeldovich effect selected clusters from the South Pole Telescope survey, which have been imaged in the science verification phase of the Dark Energy Survey. The sample extends up to z ~ 1.1 with 4 × 10 14 M⊙ ≤ M200 ≤ 3 × 10 15 M⊙. Using the band containing the 4000 Å break and its redward neighbour, we study the colour–magnitude distributions of cluster galaxies to ~m* + 2, finding that: (1)The intrinsic rest frame g – r colour width of the red sequence (RS) population is ~0.03 out to z ~ 0.85 with a preference for an increase to ~0.07 at z = 1, and (2) the prominence of the RS declines beyond z ~ 0.6. The spatial distribution of cluster galaxies is well described by the NFW profile out to 4R200 with a concentration of c g = 3.59$+0.20\atop{–0.18}$, 5.37$+0.27\atop{-0.24}$ and 1.38$+0.21\atop{-0.19}$ for the full, the RS and the blue non-RS populations, respectively, but with ~40 per cent to 55 per cent cluster to cluster variation and no statistically significant redshift or mass trends. The number of galaxies within the virial region N200 exhibits a mass trend indicating that the number of galaxies per unit total mass is lower in the most massive clusters, and shows no significant redshift trend. The RS fraction within R200 is (68 ± 3) per cent at z = 0.46, varies from ~55 per cent at z = 1 to ~80 per cent at z = 0.1 and exhibits intrinsic variation among clusters of ~14 per cent. Finally, we discuss a model that suggests that the observed redshift trend in RS fraction favours a transformation time-scale for infalling field galaxies to become RS galaxies of 2–3 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array

Purpose: The purpose of this study was to determine whether a two-dimensional (2D) ion chamber array detector quickly and accurately measures patient-specific dose distributions in treatment with passively scattered and spot scanning proton beams. Methods: The 2D ion chamber array detector MatriXX was used to measure the dose distributions in plastic water phantom from passively scattered and spot scanning proton beam fields planned for patient treatment. Planar dose distributions were measured using MatriXX, and the distributions were compared to those calculated using a treatment-planning system. The dose distributions generated by the treatment-planning system and a film dosimetry system were similarly compared. Results: For passively scattered proton beams, the gamma index for the dose-distribution comparison for treatment fields for three patients with prostate cancer and for one patient with lung cancer was less than 1.0 for 99% and 100% of pixels for a 3% dose tolerance and 3 mm distance-to-dose agreement, respectively. For spot scanning beams, the mean ({+-} standard deviation) percentages of pixels with gamma indices meeting the passing criteria were 97.1%{+-}1.4% and 98.8%{+-}1.4% for MatriXX and film dosimetry, respectively, for 20 fields used to treat patients with prostate cancer. Conclusions: Unlike film dosimetry, MatriXX provides not only 2D dose-distribution information but also absolute dosimetry in fractions of minutes with acceptable accuracy. The results of this study indicate that MatriXX can be used to verify patient-field specific dose distributions in proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

redMaGiC: Selecting luminous red galaxies from the DES Science Verification data

Here, we introduce redMaGiC, an automated algorithm for selecting luminous red galaxies (LRGs). The algorithm was specifically developed to minimize photometric redshift uncertainties in photometric large-scale structure studies. redMaGiC achieves this by self-training the colour cuts necessary to produce a luminosity-thresholded LRG sample of constant comoving density. We demonstrate that redMaGiC photo-zs are very nearly as accurate as the best machine learning-based methods, yet they require minimal spectroscopic training, do not suffer from extrapolation biases, and are very nearly Gaussian. We apply our algorithm to Dark Energy Survey (DES) Science Verification (SV) data to produce a redMaGiC catalogue sampling the redshift range z ϵ [0.2, 0.8]. Our fiducial sample has a comoving space density of 10 –3 (h –1 Mpc) –3 , and a median photo-z bias (zspec – zphoto) and scatter (σz/(1 + z)) of 0.005 and 0.017, respectively. The corresponding 5σ outlier fraction is 1.4 per cent. We also test our algorithm with Sloan Digital Sky Survey Data Release 8 and Stripe 82 data, and discuss how spectroscopic training can be used to control photo-z biases at the 0.1 per cent level.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements to the New CTH Code Verification & Validation Test Suite (FY2020)

The CTH multiphysics hydrocode, which is used for a wide range of important calculations, has undertaken in recent years to overhaul its software quality and testing processes. A key part of this effort entailed building a new, robust V&V test suite made up of traditional hydrocode verification problems, such as those listed in the ASC Tri-Lab Test Suite and the Enhanced Tri-Lab Test Suite, as well as validation problems for some of CTHs most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards this goal was made in FY19. In FY20, this test suite has been expanded to include verification and validation tests of the Sesame and JWL equation of state models as well as the Mader verification problem from the Tri-Lab Test Suite and the Blake verification problem - a linear elastic analog to the Hunter problem from the Enhanced Tri-Lab Test Suite. This report documents CTH performance on the new test suite problems. Verification test results are compared to analytic solutions and, for most tests, convergence results are presented. Validation test results are compared to experimental data and mesh refinement studies are included. CTH performs well overall on the new test problems. Convergence rates for the Blake and Mader problems are comparable to those for similar ASC codes. The JWL and Sesame verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data for the Sesame and JWL equations of state for the materials tested. Future V&V work will focus on adding tests for other key capabilities like fracture and high explosive models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical Prediction and Experimental Verification of IrO x Supported on Titanium Nitride for Acidic Oxygen Evolution Reaction

Reducing iridium (Ir) catalyst loading for acidic oxygen evolution reaction (OER) is a critical strategy for large-scale hydrogen production via proton exchange membrane (PEM) water electrolysis. However, simultaneously achieving high activity, long-term stability, and reduced material cost remains challenging. To address this challenge, we develop a frame-work by combining density functional theory (DFT) prediction using model surfaces and proof-of-concept experimental ver-ification using thin films and nanoparticles. DFT results predict that oxidized Ir monolayers over titanium nitride (IrO x /TiN) should display higher OER activity than IrO x while reducing Ir loading. Further, this prediction is verified by depositing Ir monolayers over TiN thin films via physical vapor deposition. The promising thin film results are then extended to commercially viable powder IrO x /TiN catalysts, which demonstrate a lower overpotential and higher mass activity than commercial IrO 2 , and a long-term stability of 250 hours to maintain a current density of 10 mA cm -2 . The superior OER performance of IrO x /TiN is further confirmed using proton exchange membrane water electrolyzer (PEMWE), which shows a lower cell voltage than commercial IrO 2 to achieve a current density of 1 A cm -2 . Both DFT and in situ X-ray absorption spectroscopy reveal that the high OER performance of IrO x /TiN strongly depends on the IrO x - TiN interaction via direct Ir-Ti bonding. This study highlights the importance of close interaction between theoretical prediction based on mechanistic understanding and experimental verification based on thin film model catalysts to facilitate the development of more practical powder IrO x /TiN catalysts with high activity and stability for acidic OER.

08 HYDROGEN↗

Spectroscopic Evidence of Phosphorous Heterocycle–DNA Interaction and its Verification by Docking Approach

In the present work, the interaction of phosphorous heterocycle (PH) with calf thymus DNA (CTDNA) has been studied using spectroscopy and verified by molecular modeling which is found to be in consonance with each other. Apparent association constant (K{sub app} = 4.77 × 10{sup 3} M{sup − 1}), calculated using UV–Vis spectra indicating an adequate complex formation between CTDNA and PH. A dynamic mode of the fluorescence quenching mechanism in case of ethidium bromide (EB) + CTDNA by PH has been observed confirming formation of DNA-PH complex. A moderate binding constants of PH with CTDNA + EB has been observed (2.74 × 10{sup 4} M{sup − 1} at 293 K) by means of fluorescence data. Calculated values of thermodynamic parameters enthalpy change (ΔH) and entropy change (ΔS), suggests weak (van der Walls like) force and hydrogen bonds playing the main role in the binding of PH to CTDNA. Furthermore, the results of circular dichroism (CD) reveal that PH does not disturb native conformation of CTDNA. As observed from absorption and fluorescence spectroscopy the binding mode of PH with DNA was indicative of a non-intercalative binding, which was supposed to be a groove binding. The molecular modeling results show that PH is capable of binding DNA having docking binding energy = -7.26 kcal × mol{sup − 1}. Above mentioned experimental results are found to be in consonance with molecular docking simulations and supports the CTDNA-PH binding. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A verification library for multibody simulation software

A multibody dynamics verification library, that maintains and manages test and validation data is proposed, based on RRC Robot arm and CASE backhoe validation and a comparitive study of DADS, DISCOS, and CONTOPS that are existing public domain and commercial multibody dynamic simulation programs. Using simple representative problems, simulation results from each program are cross checked, and the validation results are presented. Functionalities of the verification library are defined, in order to automate validation procedure.

Kim, Sung-Soo↗

The Science, Engineering, and Validation of Marine Carbon Dioxide Removal and Storage

Scenarios to stabilize global climate and meet international climate agreements require rapid reductions in human carbon dioxide (CO 2 ) emissions, often augmented by substantial carbon dioxide removal (CDR) from the atmosphere. While some ocean-based removal techniques show potential promise as part of a broader CDR and decarbonization portfolio, no marine approach is ready yet for deployment at scale because of gaps in both scientific and engineering knowledge. Marine CDR spans a wide range of biotic and abiotic methods, with both common and technique-specific limitations. Further targeted research is needed on CDR efficacy, permanence, and additionality as well as on robust validation methods—measurement, monitoring, reporting, and verification—that are essential to demonstrate the safe removal and long-term storage of CO 2 . Engineering studies are needed on constraints including scalability, costs, resource inputs, energy demands, and technical readiness. Research on possible co-benefits, ocean acidification effects, environmental and social impacts, and governance is also required.

climate mitigation↗

High-Fidelity Numerical Investigation on Elucidating Sodium Heat Transfer Characteristics for 37-Pin Wire-Wrapped Fuel Bundle in the PLANDTL Facility

This study involved a Reynolds-averaged Navier-Stokes- (RANS-) based computational fluid dynamics (CFD) analysis of the 37-pin wire-wrapped fuel bundle of the PNC Plant dynamics test loop (PLANDTL) facility. Previously, mainly the hydrodynamic phenomena of the wire-wrapped fuel bundle were analyzed, but the present study additionally included heat transfer analysis through conjugate heat transfer. The main purpose of the study was to benchmark the experimental data of the PLANDTL 37-pin wire-wrapped fuel bundle to investigate the heat transfer phenomena. In addition, the aim was to verify the accuracy of the RANS-based CFD analysis method using the STAR-CCM+ simulation software in comparison with the experimental data. The grid used for verification was an innovative grid system consisting of hexahedra using Fortran-based code. The development of the RANS-based CFD methodology included grid sensitivity analysis, turbulence model sensitivity analysis, and turbulent Prandtl number sensitivity analysis. Information on the temperature, mass flow rate, and area of the CFD results for each subchannel was provided for the top of the heated section and is expected to serve as a reference for future studies aiming to perform the validation and verification of a PLANDTL facility. In addition, the dependence of the peak temperature on the azimuth angle of each pin was analyzed.

97 MATHEMATICS AND COMPUTING↗

Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy

Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation. Methods: Proton therapy using a beam on-line PET system mounted on a rotating gantry port (BOLPs-RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs-RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs-RGp. Results: The decay curves for measured activity were able to be approximated using two or three half-life values regardless of the treatment site. The activity of half-life value of about 2 min was important for a confirmation of the proton irradiated volume. Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs-RGp. For the monitoring of the proton irradiated volume, the detection of {sup 15}O generated in a human body was important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated Algorithms for High-Throughput Examination of Covalently Labeled Biomolecules by Structural Mass Spectrometry

Mass spectrometry based structural proteomics approaches for probing protein structures are increasingly gaining in popularity. The potential for such studies is limited because of the lack of analytical techniques for the automated interpretation of resulting data. In this article, a suite of algorithms called ProtMapMS is developed, integrated, and implemented specifically for the comprehensive automatic analysis of mass spectrometry data obtained for protein structure studies using covalent labeling. The functions include data format conversion, mass spectrum interpretation, detection, and verification of all peptide species, confirmation of the modified peptide products, and quantification of the extent of peptide modification. The results thus obtained provide valuable data for use in combination with computational approaches for protein structure modeling. The structures of both monomeric and hexameric forms of insulin were investigated by oxidative protein footprinting followed by high-resolution mass spectrometry. The resultant data was analyzed both manually and using ProtMapMS without any manual intervention. The results obtained using the two methods were found to be in close agreement and overall were consistent with predictions from the crystallographic structure.

59 BASIC BIOLOGICAL SCIENCES↗

Modernization and optimization of a legacy open-source CFD code for high-performance computing architectures

Legacy codes remain a crucial element of today's simulation-based engineering ecosystem due to the extensive validation process and investment in such software. The rapid evolution of high-performance computing architectures necessitates the modernization of these codes. One approach to modernization is a complete overhaul of the code. However, this could require extensive investments, such as rewriting in modern languages, new data constructs, etc., which will necessitate systematic verification and validation to re-establish the credibility of the computational models. The current study advocates using a more incremental approach and is a culmination of several modernization efforts of the legacy code MFIX, which is an open-source computational fluid dynamics code that has evolved over several decades, widely used in multiphase flows and still being developed by the National Energy Technology Laboratory. Two different modernization approaches,‘bottom-up’ and ‘top-down’, are illustrated. Here, preliminary results show up to 8.5x improvement at the selected kernel level with the first approach, and up to 50% improvement in total simulated time with the latter were achieved for the demonstration cases and target HPC systems employed.

97 MATHEMATICS AND COMPUTING↗

Structural Loads Analysis for Wave Energy Converters: Preprint

This study explores and verifies the generalized body-modes method for evaluating the structural loads on a wave energy converter (WEC). Historically, WEC design methodologies have focused primarily on accurately evaluating hydrodynamic loads, while methodologies for evaluating structural loads have yet to be fully considered and incorporated into the WEC design process. As wave energy technologies continue to advance, however, it has become increasingly evident that an accurate evaluation of the structural loads will enable an optimized structural design, as well as the potential utilization of composites and flexible materials, and hence reduce WEC costs. Although there are many computational fluid dynamics, structural analyses and fluid-structure-interaction (FSI) codes available, the application of these codes is typically too computationally intensive to be practical in the early stages of the WEC design process. The generalized body-modes method, however, is a reduced order, linearized, frequency-domain FSI approach, performed in conjunction with the linear hydrodynamic analysis, with computation times that could realistically be incorporated into the WEC design process. The objective of this study is to verify the generalized body-modes approach in comparison to high-fidelity FSI simulations to accurately predict structural deflections and stress loads in a WEC. Two verification cases are considered, a free-floating barge and a fixed-bottom column. Details for both the generalized body-modes models and FSI models are first provided. Results for each of the models are then compared and discussed. Finally, based on the verification results obtained, future plans for incorporating the generalized body-modes method into the WEC simulation tool, WEC-Sim, and the overall WEC design process are discussed.

17 WIND ENERGY↗

In aqua vivo EPID dosimetry

Purpose: At the Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the original back-projection dose-reconstruction algorithm uses water-based scatter-correction kernels and therefore does not account for tissue inhomogeneities accurately. The aim of this study was to test a new method, in aqua vivo EPID dosimetry, for fast dose verification of lung cancer irradiations during actual patient treatment. Methods: The key feature of our method is the dose reconstruction in the patient from EPID images, obtained during the actual treatment, whereby the images have been converted to a situation as if the patient consisted entirely of water; hence, the method is termed in aqua vivo. This is done by multiplying the measured in vivo EPID image with the ratio of two digitally reconstructed transmission images for the unit-density and inhomogeneous tissue situation. For dose verification, a comparison is made with the calculated dose distribution with the inhomogeneity correction switched off. IMRT treatment verification is performed for each beam in 2D using a 2D {gamma} evaluation, while for the verification of volumetric-modulated arc therapy (VMAT) treatments in 3D a 3D {gamma} evaluation is applied using the same parameters (3%, 3 mm). The method was tested using two inhomogeneous phantoms simulating a tumor in lung and measuring its sensitivity for patient positioning errors. Subsequently five IMRT and five VMAT clinical lung cancer treatments were investigated, using both the conventional back-projection algorithm and the in aqua vivo method. The verification results of the in aqua vivo method were statistically analyzed for 751 lung cancer patients treated with IMRT and 50 lung cancer patients treated with VMAT. Results: The improvements by applying the in aqua vivo approach are considerable. The percentage of {gamma} values {<=}1 increased on average from 66.2% to 93.1% and from 43.6% to 97.5% for the IMRT and VMAT cases, respectively. The corresponding mean {gamma} value decreased from 0.99 to 0.43 for the IMRT cases and from 1.71 to 0.40 for the VMAT cases, which is similar to the accepted clinical values for the verification of IMRT treatments of prostate, rectum, and head-and-neck cancers. The deviation between the reconstructed and planned dose at the isocenter diminished on average from 5.3% to 0.5% for the VMAT patients and was almost the same, within 1%, for the IMRT cases. The in aqua vivo verification results for IMRT and VMAT treatments of a large group of patients had a mean {gamma} of approximately 0.5, a percentage of {gamma} values {<=}1 larger than 89%, and a difference of the isocenter dose value less than 1%. Conclusions: With the in aqua vivo approach for the verification of lung cancer treatments (IMRT and VMAT), we can achieve results with the same accuracy as obtained during in vivo EPID dosimetry of sites without large inhomogeneities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗