Search NASA⌕ Search

SEARCH · Search NASA

Results for “Well Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Active Matrix OLED Test Report

This report focuses on the limited environmental testing of the AMOLED display performed as an engineering evaluation by The NASA Johnson Space Center (JSC)-specifically. EMI. Thermal Vac, and radiation tests. The AMOLED display is an active-matrix Organic Light Emitting Diode (OLED) technology. The testing provided an initial understanding of the technology and its suitability for space applications. Relative to light emitting diode (LED) displays or liquid crystal displays (LCDs), AMOLED displays provide a superior viewing experience even though they are much lighter and smaller, produce higher contrast ratio and richer colors, and require less power to operate than LCDs. However, AMOLED technology has not been demonstrated in a space environment. Therefore, some risks with the technology must be addressed before they can be seriously considered for human spaceflight. The environmental tests provided preliminary performance data on the ability of the display technology to handle some of the simulated induced space/spacecraft environments that an AMOLED display will see during a spacecraft certification test program. This engineering evaluation is part of a Space Act Agreement (SM) between The NASA/JSC and Honeywell International (HI) as a collaborative effort to evaluate the potential use of AMOLED technology for future human spaceflight missions- both government-led and commercial. Under this SM, HI is responsible for doing optical performance evaluation, as well as temperature and touch screen studies. The NASA/JSC is responsible for performing environmental testing comprised of EMI, Thermal Vac, and radiation tests. Additionally, as part of the testing, limited optical data was acquired to assess performance as the display was subjected to the induced environments. The NASA will benefit from this engineering evaluation by understanding AMOLED suitability for future use in space as well as becoming a smarter buyer (or developer) of the technology. HI benefits from the environmental testing results by understanding its performance limitations/shortcomings to improve subsequent generations of AMOLED technology. Note that the AMOLED used in this test was not deSigned for the space environment but rather for commercial/industrial terrestrial applications.

Salazar, George↗

Active Matrix Organic Light Emitting Diode (AMOLED) Environmental Test Report

This report focuses on the limited environmental testing of the AMOLED display performed as an engineering evaluation by The NASA Johnson Space Center (JSC)-specifically. EMI. Thermal Vac, and radiation tests. The AMOLED display is an active-matrix Organic Light Emitting Diode (OLED) technology. The testing provided an initial understanding of the technology and its suitability for space applications. Relative to light emitting diode (LED) displays or liquid crystal displays (LCDs), AMOLED displays provide a superior viewing experience even though they are much lighter and smaller, produce higher contrast ratio and richer colors, and require less power to operate than LCDs. However, AMOLED technology has not been demonstrated in a space environment. Therefore, some risks with the technology must be addressed before they can be seriously considered for human spaceflight. The environmental tests provided preliminary performance data on the ability of the display technology to handle some of the simulated induced space/spacecraft environments that an AMOLED display will see during a spacecraft certification test program. This engineering evaluation is part of a Space Act Agreement (SM) between The NASA/JSC and Honeywell International (HI) as a collaborative effort to evaluate the potential use of AMOLED technology for future human spaceflight missions- both government-led and commercial. Under this SM, HI is responsible for doing optical performance evaluation, as well as temperature and touch screen studies. The NASA/JSC is responsible for performing environmental testing comprised of EMI, Thermal Vac, and radiation tests. Additionally, as part of the testing, limited optical data was acquired to assess performance as the display was subjected to the induced environments. The NASA will benefit from this engineering evaluation by understanding AMOLED suitability for future use in space as well as becoming a smarter buyer (or developer) of the technology. HI benefits from the environmental testing results by understanding its performance limitations/shortcomings to improve subsequent generations of AMOLED technology. Note that the AMOLED used in this test was not deSigned for the space environment but rather for commercial/industrial terrestrial applications.

Salazar, George A.↗

A Simple Data-Centric Methodology for Producible Geothermal Well Determinations: Preprint

The Bureau of Land Management (BLM) has traditionally lacked a standardized methodology for determining if a newly drilled geothermal well is "producible," a designation essential for deciding whether a lease should be "held by production." This is a straightforward problem to solve in oil and gas: Demonstrate that a well is economically viable, meaning it produces sufficient oil or gas to exceed direct operating costs and lease-related expenses, such as rentals or minimum royalties. In geothermal, the problem is more complex: Geothermal wells are tightly coupled with the downstream infrastructure - specifically, the power plant, which is often not designed until well after a lease is deemed as "held by production." Although this designation is critical for advancing geothermal power plant development on BLM-managed lands, current geothermal well assessments often rely on ad hoc approaches that can be complex, operator-biased, and heavy in assumptions related to economic viability. To address this, we have developed two complementary methodologies: a minimum power requirement-based approach and a productivity index (PI)-based approach. These methods leverage key flow test data - pressure, temperature, flow rate, and specific enthalpy - to provide reliable and standardized producible well determinations. The minimum power requirement-based approach evaluates wells against specific power output thresholds informed by reservoir experts and the associated temperature requirements. The PI-based approach assesses well productivity using widely accepted reservoir engineering metrics, proposing a threshold of 2.5 kg/s/bar. Both methods are data-driven and grounded in empirical production data from operational geothermal wells, avoiding uncertain economic assumptions while maintaining decision-making accuracy. Wells falling below key performance thresholds (i.e., PI, specific power) are deemed non-producible. These methodologies aim to streamline BLM's decision-making process, reduce nontechnical barriers to geothermal energy adoption, and enable regulatory expansion into states lacking geothermal expertise. Preliminary results indicate clear trends and thresholds in production data that provide actionable insights for evaluating well producibility. Validation using well completion report (WCR) data is ongoing, with promising results demonstrating the potential for these standardized methodologies to impact geothermal development significantly.

15 GEOTHERMAL ENERGY↗

Data Reconciliation and Gross Error Detection: A Filtered Measurement Test

Measured process data commonly contain inaccuracies because the measurements are obtained using imperfect instruments. As well as random errors one can expect systematic bias caused by miscalibrated instruments or outliers caused by process peaks such as sudden power fluctuations. Data reconciliation is the adjustment of a set of process data based on a model of the process so that the derived estimates conform to natural laws. In this paper, we will explore a predictor-corrector filter based on data reconciliation, and then a modified version of the measurement test is combined with the studied filter to detect probable outliers that can affect process measurements. The strategy presented is tested using dynamic simulation of an inverted pendulum.

99 GENERAL AND MISCELLANEOUS↗

Benchmark Testing of a New 56 Fe Evaluation for Criticality Safety Applications

The SAMMY code was used to evaluate resonance parameters of the 56 Fe cross section in the resolved resonance energy range of 0–2 MeV using transmission data, capture, elastic, inelastic, and double differential elastic cross sections. The resonance analysis was performed with the code SAMMY that fits R-matrix resonance parameters using the generalized least-squares technique (Bayes’ theory). The evaluation yielded a set of resonance parameters that reproduced the experimental data very well, along with a resonance parameter covariance matrix for data uncertainty calculations. Benchmark tests were conducted to assess the evaluation performance in benchmark calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operation and design considerations for unsteady data acquisition with PC-based systems in high Reynolds number hypersonic flowfields

Operation and design considerations for personal-computer-based data acquisition are analyzed, and a system is created that is portable, inexpensive, and capable of high-frequency response. This system performed well when given an extensive analysis of the characteristics of the radio-frequency noise in the test environment. The system architecture is well-suited for support of high-frequency data acquisition from both pressure transducers and high-frequency-response thermocouple gauges. As configured, the system provides a data resolution of approximately 0.09 psia and 0.56 F. Considering the constraints placed upon this design, this data resolution is acceptable. The $5000 budget did require use of an existing PC and rental of signal-conditioning equipment.

Flanagan, M. J., Jr.↗

Versatile Software Package For Near Real-Time Analysis of Experimental Data

This paper provides an overview of a versatile software package developed for time- and frequency-domain analyses of experimental wind-tunnel data. This package, originally developed for analyzing data in the NASA Langley Transonic Dynamics Tunnel (TDT), is applicable for analyzing any time-domain data. A Matlab-based software package, TDT-analyzer, provides a compendium of commonly-required dynamic analysis functions in a user-friendly interactive and batch processing environment. TDT-analyzer has been used extensively to provide on-line near real-time and post-test examination and reduction of measured data acquired during wind tunnel tests of aeroelastically-scaled models of aircraft and rotorcraft as well as a flight test of the NASA High Alpha Research Vehicle (HARV) F-18. The package provides near real-time results in an informative and timely manner far exceeding prior methods of data reduction at the TDT.

Wieseman, Carol D.↗

The Atacama Cosmology Telescope: DR6 constraints on extended cosmological models

We use new cosmic microwave background (CMB) primary temperature and polarization anisotropy measurements from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) to test foundational assumptions of the standard cosmological model, ΛCDM, and set constraints on extensions to it. We derive constraints from the ACT DR6 power spectra alone, as well as in combination with legacy data from the Planck mission. To break geometric degeneracies, we include ACT and Planck CMB lensing data and baryon acoustic oscillation data from DESI Year-1. To test the dependence of our results on non-ACT data, we also explore combinations replacing Planck with WMAP and DESI with BOSS, and further add supernovae measurements from Pantheon+ for models that affect the late-time expansion history. We verify the near-scale-invariance (running of the spectral index dn s /d ln k = 0.0062 ± 0.0052) and adiabaticity of the primordial perturbations. Neutrino properties are consistent with Standard Model predictions: we find no evidence for new light, relativistic species that are free-streaming (N eff = 2.86 ± 0.13, which combined with astrophysical measurements of primordial helium and deuterium abundances becomes N eff = 2.89 ± 0.11), for non-zero neutrino masses (∑m ν < 0.089 eV at 95% CL), or for neutrino self-interactions. We also find no evidence for self-interacting dark radiation (N idr < 0.134), or for early-universe variation of fundamental constants, including the fine-structure constant (α EM /α EM,0 = 1.0043 ± 0.0017) and the electron mass (m e /m e,0 = 1.0063 ± 0.0056). Our data are consistent with standard big bang nucleosynthesis (we find Y p = 0.2312 ± 0.0092), the COBE/FIRAS-inferred CMB temperature (we find T CMB = 2.698 ± 0.016 K), a dark matter component that is collisionless and with only a small fraction allowed as axion-like particles, a cosmological constant (w = -0.986 ± 0.025), and the late-time growth rate predicted by general relativity (γ = 0.663 ± 0.052). We find no statistically significant preference for a departure from the baseline ΛCDM model. In fits to models invoking early dark energy, primordial magnetic fields, or an arbitrary modified recombination history, we find H 0 = 69.9 +0.8 -1.5 , 69.1 ± 0.5, or 69.6 ± 1.0 km/s/Mpc, respectively; using BOSS instead of DESI BAO data reduces the central values of these constraints by 1–1.5 km/s/Mpc while only slightly increasing the error bars. In general, models introduced to increase the Hubble constant or to decrease the amplitude of density fluctuations inferred from the primary CMB are not favored over ΛCDM by our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large-Scale Groundwater Monitoring in Brazil Assisted With Satellite-Based Artificial Intelligence Techniques

Here, we develop and test an artificial intelligence (AI)-based approach to monitor major Brazilian aquifers. The approach combines Gravity Recovery and Climate Experiment (GRACE) data and ground-based hydrogeological measurements from Brazil’s Integrated Groundwater Monitoring Network at hundreds of wells distributed in twelve aquifers across the country. We tested model ensembles based on three AI approaches: Extreme Gradient Boost, Light Gradient Boosting Model and CatBoost, followed by a Linear Regression (LR) step. The approach is further boosted with wavelet and seasonal decomposition processes applied to GRACE data. To determine the AI-based model’s sensitivity to data availability, we propose four experiments combining hydrogeological measurements from different aquifers. Groundwater storage estimates from the Global Land Data Assimilation System (GLDAS) are used as benchmark. A sensitivity analysis shows that the LR-based model ensemble is the best suited and to reproduce groundwater storage change in all studied Brazilian aquifers. Results show that the proposed approach outperforms GLDAS in all experiments, with an RMSE value of 2.68cm for the experiment that covers all monitored wells in Brazil. GLDAS resulted in RMSE=6.76cm. Using our AI model outputs, we quantified the groundwater storage change of two major aquifers, Urucuia and Bauru-Caiuá, over the past two decades: -31km 3 and -6km 3 , respectively. Water loss is driven by a prolonged drought across most of the country and intensification of groundwater pumping for irrigation. This study demonstrates that combining satellite data and AI can be a cost-effective alternative to monitor poorly equipped aquifers at the continental scale, with possible global replicability.

GRACE↗

Benchmark Testing of a new {sup 56}Fe evaluation for criticality safety applications - 14451

The SAMMY code was used to evaluate resonance parameters of the {sup 56}Fe cross section in the resolved resonance energy range of 0-2 MeV using transmission data, capture, elastic, inelastic, and double differential elastic cross sections. The resonance analysis was performed with the code SAMMY that fits R-matrix resonance parameters using the generalized least-squares technique (Bayes' theory). The evaluation yielded a set of resonance parameters that reproduced the experimental data very well, along with a resonance parameter covariance matrix for data uncertainty calculations. Benchmark tests were conducted to assess the evaluation performance in benchmark calculations. (authors)

42 ENGINEERING↗

A Method of Determining Accuracy and Precision for Dosimeter Systems Using Accreditation Data

A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Green Propellant Test Capabilities of the Altitude Combustion Stand at the NASA Glenn Research Center

The NASA Glenn Research Center (GRC) is committed to providing simulated altitude rocket test capabilities to NASA programs, other government agencies, private industry partners, and academic partners. A primary facility to support those needs is the Altitude Combustion Stand (ACS). ACS provides the capability to test combustion components at a simulated altitude up to 100,000 ft. (approx.0.2 psia/10 Torr) through a nitrogen-driven ejector system. The facility is equipped with an axial thrust stand, gaseous and cryogenic liquid propellant feed systems, data acquisition system with up to 1000 Hz recording, and automated facility control system. Propellant capabilities include gaseous and liquid hydrogen, gaseous and liquid oxygen, and liquid methane. A water-cooled diffuser, exhaust spray cooling chamber, and multi-stage ejector systems can enable run times up to 180 seconds to 16 minutes. The system can accommodate engines up to 2000-lbf thrust, liquid propellant supply pressures up to 1800 psia, and test at the component level. Engines can also be fired at sea level if needed. The NASA GRC is in the process of modifying ACS capabilities to enable the testing of green propellant (GP) thrusters and components. Green propellants are actively being explored throughout government and industry as a non-toxic replacement to hydrazine monopropellants for applications such as reaction control systems or small spacecraft main propulsion systems. These propellants offer increased performance and cost savings over hydrazine. The modification of ACS is intended to enable testing of a wide range of green propellant engines for research and qualification-like testing applications. Once complete, ACS will have the capability to test green propellant engines up to 880 N in thrust, thermally condition the green propellants, provide test durations up to 60 minutes depending on thrust class, provide high speed control and data acquisition, as well as provide advanced imaging and diagnostics such as infrared (IR) imaging.

Testing↗

A math model for high velocity sensoring with a focal plane shuttered camera.

A new mathematical model is presented which describes the image produced by a focal plane shutter-equipped camera. The model is based upon the well-known collinearity condition equations and incorporates both the translational and rotational motion of the camera during the exposure interval. The first differentials of the model with respect to exposure interval, delta t, yield the general matrix expressions for image velocities which may be simplified to known cases. The exposure interval, delta t, may be replaced under certain circumstances with a function incorporating blind velocity and image position if desired. The model is tested using simulated Lunar Orbiter data and found to be computationally stable as well as providing excellent results, provided that some external information is available on the velocity parameters.

Morgan, P.↗

Noise Spectra and Directivity For a Scale-Model Landing Gear

An extensive experimental study has been conducted to acquire detailed noise spectra and directivity data for a high-fidelity, 6.3%-scale, Boeing 777 main landing gear. The measurements were conducted in the NASA Langley Quiet Flow Facility using a 41-microphone directional array system positioned at a range of polar and azimuthal observer angles with respect to the model. DAMAS (Deconvolution Approach for the Mapping of Acoustic Sources) array processing as well as straightforward individual microphone processing were employed to compile unique flyover and sideline directivity databases for a range of freestream Mach numbers (0.11 - 0.17) covering typical approach conditions. Comprehensive corrections were applied to the test data to account for shear layer ray path and amplitude variations. This allowed proper beamforming at different measurement orientations, as well as directivity presentation in free-field emission coordinates. Four different configurations of the landing gear were tested: a baseline configuration with and without an attached side door, and a noise reduction concept "toboggan" truck fairing with and without side door. DAMAS noise source distributions were determined. Spectral analyses demonstrated that individual microphones could establish model spectra. This finding permitted the determination of unique, spatially-detailed directivity contours of spectral band levels over a hemispherical surface. Spectral scaling for the baseline model confirmed that the acoustic intensity scaled with the expected sixth-power of the Mach number. Finally, comparison of spectra and directivity between the baseline gear and the gear with an attached toboggan indicated that the toboggan fairing may be of some value in reducing gear noise over particular frequency ranges.

Humphreys, William M., Jr.↗

Thematic mapper flight model preshipment review data package. Volume 3, part A: System data

Results of vibration, acoustical noise, and thermal vacuum are described as well as tests studies of EMI/EMC and mass properties conducted for thematic mapper systems integration. Liens are summarized and the engineering change proposal status is presented. Requests for deviation/waiver are included along with failure and nonforming material reports.

Source record↗

Detection of Low Volatility Organic Analytes on Soils Using Infrared Reflection Spectroscopy

Previous work on detection of low-volatility liquid organic (and organophosphorus) analytes on soil indicated strong signal in FTIR spectra in the 2966–2855 cm-1 range attributed to C–H vibrational stretching modes. This range is the focus of detection strategies examined here as an anticipated prelude to subsequent detection and classification approaches utilizing additional spectral bands. This laboratory study is being used to test detection algorithms that may be useful for rapid standoff detection of organics compounds on soil. Six signal processing methods (designed to minimize irrelevant variability in the recorded soil reflection-absorption spectra while enhancing signal from analyte compounds possibly present on soil) were studied. These included Savitzky-Golay second derivatives, extended multiplicative scatter correction (EMSC), and a novel alternative to piece-wise EMSC. The preprocessed signal was then used for detection. Previous work utilized principal components analysis (PCA) based multivariate statistical process control methodologies for detection. Six alternative anomaly detection statistics were examined here that were based on the preprocessed signal, weighted signal, and generalized weighted signal. The latter statistic can be considered easier than PCA with many of the same benefits. Two tests corresponding to different monitoring strategies were examined: test data ‘local’ and ‘non-local’ to the calibration data. Although the results are expected to be optimistic, the generalized weighted approach worked extremely well for the ‘local’ detection test, but was less successful for ‘non-local’ test. Results suggest that good characterization of analyte-free soil prior to monitoring will lead to the best detection performance. Second derivative preprocessing showed the best results on receiver operator characteristic curves and it’s ease of application is a distinct advantage. However, it may not be universally successful for all bands to be considered in the future. Both EMSC and the novel ‘piece-wise’ EMSC methodology showed promise, but some improvements may be necessary.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of CFD as a Surrogate for Wind-Tunnel Testing: Experimental Uncertainty Quantification for the UPWT Flow Survey Test

A series of wind tunnel tests are being performed at the Unitary Plan Wind Tunnel (UPWT)at NASA Langley Research Center to assess the validity of using computational fluid dynamics(CFD) as a surrogate for wind tunnel testing. In order to make proper comparisons, uncertainties in CFD results and experimental data must be well understood. The material presented highlights the methods, assumptions, and inputs used to achieve experimental uncertainty estimates. Results for a small subset of tunnel conditions and variables of interest from the first test in the series, the Flow Survey Test, are highlighted and sample CFD comparisons are shown. The bulk of the results from this work are used for comparisons in other AIAA conference papers related to this test series.

Erin P Hubbard↗