Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Vapor and Liquid ( p –ρ– T–x ) Measurements of Binary Refrigerant Blends Containing R-32, R-152a, R-227ea, R-1234yf, and R-1234ze(E)

In this article, The pressure–density–temperature–composition (p–ρ–T–x) data of binary refrigerant mixtures containing R-32 (difluoromethane), R-152a (1,1,-difluoroethane), R-227ea (1,1,1,2,3,3,3-heptafluoropropane), R-1234yf (2,3,3,3-tetrafluoropropene), and R-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) were measured in both the vapor and liquid phases using a two-sinker, magnetic suspension densimeter. The specific samples in this study comprised two compositions of approximately (0.3/0.7) and (0.7/0.3) mole fraction for each of the following four binary refrigerant blends: R-32 + R-1234yf, R-32 + R-1234ze(E), R-1234yf + R-152a, and R-1234ze(E) + R-227ea. Single-phase vapor densities were measured over a temperature range of approximately 253 to 293 K and pressures from 0.05 to 0.98 MPa. Single-phase liquid and supercritical densities were measured over a temperature range of approximately 230 to 400 K and pressures up to 22 MPa; for refrigerant blends containing R-1234yf, the maximum pressure was limited to 14 MPa. Overall relative combined, expanded (k = 2) uncertainties in density ranged from 0.025 to 0.191%, with an average uncertainty of approximately 0.05%. Here, we present measurement results, along with comparisons to available literature data and to default equations of state and mixture models included in REFPROP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Installation and testing of a focusing mirror at beamline X28C for high flux x-ray radiolysis of biological macromolecules

The NSLS X28C white-light beamline has been upgraded with a focusing mirror in order to provide increased x-ray density and a wide selection of beam shapes at the sample position. The cylindrical single crystal silicon mirror uses an Indalloy 51 liquid support bath as both a mechanism for heat transfer and a buoyant support to counter the effects of gravity and correct for minor parabolic slope errors. Calorimetric measurements were performed to verify that the calculated more than 200-fold increase in flux density is delivered by the mirror at the smallest beam spot. The properties of the focused beam relevant to radiolytic footprinting, namely, the physical dimensions of the beam, the effective hydroxyl radical dose delivered to the sample, and sample heating upon irradiation, have been studied at several mirror angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Conformer Sampling for Property Prediction Using the Conductor-like Screening Model for Real Solvents

The valorization of lignocellulose-derived bioproducts requires effective separation from excessive water. Liquid–liquid extraction is a promising low-energy separation technology, but effective extraction requires solvent selection based on the thermodynamic properties of the bioproduct and solvent components. We propose a computational framework for predicting such properties by developing an adaptive conformer selection approach for use with COSMO-RS (conductor-like screening model for real solvents) calculations. In this framework, molecular dynamics simulations are used to generate many molecular structures (conformers) at representative temperatures in varying solvent environments. Conformers are then clustered based on structural metrics in a low-dimensional space and selected using a mixed-integer quadratic programming problem to iteratively insert a sampled conformer. At each iteration, we determine bioproduct properties using COSMO-RS. Here, we demonstrate the capability of the proposed framework on representative bioproducts to show convergence of the adaptive sampling toward experimentally measured properties with fewer calculations than required by random conformer sampling, enabling the improved screening of solvent systems for liquid-phase separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic system for transmission electron microscopy

We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

99 GENERAL AND MISCELLANEOUS↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating Drizzle Parameters by Aircraft Sampling

In-cloud supersaturation is calculated from aircraft derived measurements of the in-cloud vertical gradient of liquid water content, vertical velocity, the pt and 3 rd cloud droplet radius moments and a parameter related to the heat and mass transport during condensation and evaporation of cloud droplets. The aircraft data where taken during the VOCALS 2008 study in marine stratocumulus clouds off the coast of Chile. Approximately 16000 discrete samples, 2.5 meter in length, were used in the present analysis of in-cloud supersaturation and its variability, both of which are indicative of turbulent processes within the cloud and their significant impact on drizzle formation. Two additional drizzle parameters, the eddy persistence time and the variance of fluctuations in in-cloud droplet growth rate were also estimated from this data set. These results will help to constrain parameterizations of underlying turbulent microphysical processes of clouds and thereby advance the future development of warm cloud and precipitation models for climate simulation.

54 ENVIRONMENTAL SCIENCES↗

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical Imaging of Atmospheric Biomass Burning Particles from North American Wildfires

The effects of biomass burning aerosols (BBA) on radiative forcing and cloud formation depend on chemical composition and the internal structures of individual particles within smoke plumes. To improve our understanding of the chemical and physical properties of BBA emitted at different times of the day and their evolution during atmospheric aging, we conducted a study as a part of the Fire Influence on Regional to Global Environments and Air Quality field campaign. Particle samples were collected onboard a research aircraft from smoke plumes from a wildfire in eastern Oregon during late afternoon and nighttime flights on August 28, 2019. A time-resolved aerosol collector was used to collect samples on substrates for offline spectromicroscopic imaging to investigate the single-particle characteristics of BBA particles. Approximately 20,400 individual particles from 10 selected samples were analyzed using computer-controlled scanning electron microscopy coupled with energy-dispersive X-ray microanalysis, revealing their elemental composition, morphology, and viscosity. Elemental microanalysis indicated that aged potassium is likely found in the form of K 2 SO 4 , KNO 3 , and possible K-organic salts. Further chemical speciation and carbon bonding mapping within individual particles were conducted using synchrotron-based scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Real-time, water-soluble light absorption measurements were acquired using a particle-into-liquid sampler instrument coupled to a liquid waveguide capillary cell and total organic analyzer. In the late afternoon samples, 65% of the total particle number population consisted entirely of organic components, compared to 46% in the nighttime particles. These differences were attributed to discrepancies in composition at the time of emission and to the daytime condensation and accumulation of photochemically formed secondary organic material on existing BBA particles, a process that halts at night. Microscopy images indicated that particle viscosity was lower in the nighttime particles (<10 1 Pa·s), likely due to increased relative humidity and a higher contribution from hygroscopic inorganic components. The chemical heterogeneity of individual particles was quantified using STXM-derived mixing state parameters. The nature of carbon bonding within individual particles was inferred from the extent of carbon sp 2 hybridization derived from NEXAFS spectra. Average percentages of sp 2 hybridization range between 40% and 60%, with no noticeable differences between late afternoon and nighttime flights. These findings were compared with the online optical properties of both late afternoon and nighttime smoke plumes, providing valuable insights into the complex relationship between chemical composition and optical properties of BBA particles at different times of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MS Based Metabonomics

Metabonomics is the latest and least mature of the systems biology triad, which also includes genomics and proteomics, and has its origins in the early orthomolecular medicine work pioneered by Linus Pauling and Arthur Robinson. It was defined by Nicholson and colleagues in 1999 as the quantitative measurement of perturbations in the metabolite complement of an integrated biological system in response to internal or external stimuli, and is often used today to describe many non-global types of metabolite analyses. Applications of metabonomics are extensive and include toxicology, nutrition, pharmaceutical research and development, physiological monitoring and disease diagnosis. For example, blood samples from millions of neonates are tested routinely by mass spectrometry (MS) as a diagnostic tool for inborn errors of metabolism. The metabonome encompasses a wide range of structurally diverse metabolites; therefore, no single analytical platform will be sufficient. Specialized sample preparation and detection techniques are required, and advances in NMR and MS technologies have led to enhanced metabonome coverage, which in turn demands improved data analysis approaches. The role of MS in metabonomics is still evolving as instrumentation and software becomes more sophisticated and as researchers realize the strengths and limitations of current technology. MS offers a wide dynamic range, high sensitivity, and reproducible, quantitative analysis. These attributes are essential for addressing the challenges of metabonomics, as the range of metabolite concentrations easily exceeds nine orders of magnitude in biofluids, and the diversity of molecular species ranges from simple amino and organic acids to lipids and complex carbohydrates. Additional challenges arise in generating a comprehensive metabolite profile, downstream data processing and analysis, and structural characterization of important metabolites. A typical workflow of MS-based metabonomics is shown in Figure 1. Gas chromatography-(GC)-MS was the most commonly used MS-based method for small molecule analysis in the 1970s and 1980s. It is still used today for the detection of many metabolic disorders and plays a strong role in plant metabonomics. Liquid chromatography (LC)-MS approaches have grown in popularity for metabolite studies, due to simpler sample preparation, reduced analysis times through the introduction of ultra-high performance liquid chromatography (UPLC)-MS and the ability to observe a wider range of metabolites. This chapter will discuss the role of MS in metabonomics, the techniques involved in this exciting area, and the current and future applications of the field. The various bioinformatics tools and multivariate analysis techniques used to maximize information recovery and to aid in the interpretation of the very large data sets typically obtained in metabonomics studies will also be discussed. While there are many different MS-based approaches utilized in metabonomics studies, emphasis will be placed on more established methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Noble gas ion beams in materials science for future applications and devices

Helium ion microscopy (HIM), enabled by a gas field ion source (GFIS), is an emerging imaging and nanofabrication technique compatible with many applications in materials science. The scanning electron microscope (SEM) has become ubiquitous in materials science for high-resolution imaging of materials. However, due to the fundamental limitation in focusing of electron beams, ion-beam microscopy is now being developed (e.g., at 20 kV the SEM beam diameter ranges from 0.5 to 1 nm, whereas the HIM offers 0.35 nm). The key technological advantage of the HIM is in its multipurpose design that excels in a variety of disciplines. The HIM offers higher resolution than the best available SEMs as well as the traditional gallium liquid-metal ion source (LMISs) focused ion beams (FIBs), and is capable of imaging untreated biological or other insulating samples with unprecedented resolution, depth of field, materials contrast, and image quality. GFIS FIBs also offer a direct path to defect engineering via ion implantation, three-dimensional direct write using gaseous and liquid precursors, and chemical-imaging options with secondary ion mass spectrometry. HIM covers a wide range of tasks that otherwise would require multiple tools or specialized sample preparation. In this paper, we describe the underlying technology, present materials, relevant applications, and offer an outlook for the potential of FIB technology in processing materials.

2D materials↗

Effects of SRPPF ARS Effluent Variations on Magnesium Oxysulfate Solidification

A magnesium oxysulfate (MOS) grout formulation has been identified to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO (28 wt%), anhydrous MgSO 4 (10 wt%), and dead burnt MgO (62 wt%), resulting in a grout with good mixability, acceptable density, acceptable setting times, and a leachate pH around 9.4, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. A series of tests were then designed to observe how this formula reacted to variations in the liquid effluent. Liquid effluent temperature, the caustic pH level, concentration of NaNO 3 , and the presence of neutralization products, trace metals, and/or sodium sulfate (all potential residuals found in the effluent from upstream processing), were evaluated to see how each impacts the grout mixing time, peak temperature, setting time, presence of bleed water, leachate pH, and density. The standard mix has an average mixing time of 18 minutes, peak temperature of 100.5 °C, and set time of 60 minutes. Increasing the temperature of the liquid effluent increased the reaction rate of the mix and reduced mixing and setting times. Between 30 and 40°C the change was relatively small, raising no more than 6 °C compared to the standard mix maximum temperature. Increasing the pH of the liquid effluent had no significant impact on the mix. The addition of neutralization products and trace metals had an overall impact of decreasing the reactivity of the mix. The addition of more ions in the liquid effluent, such as an increase in the concentration of NaNO 3 and the addition of Na 2 SO 4 , generally decreased the reactivity of the mix. None of the variations to the liquid effluent hindered solidification as indicated by the lack of bleed water found on all the samples. The leachate pH values for all mixes tested did not significantly vary from the expected pH of 9.4 and none of the density values fell below 1.8 g/cm 3 . Overall, changes to the liquid effluent were found to have a minimal impact on the formulation suggesting the grout's ability to properly form despite increased temperatures and the presence of residuals typically found in the liquid effluent from the ARS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Growth from Solution, Structure, and Optical Properties of Single-Crystal para-Quaterphenyl Films

Samples of single-crystal para-quaterphenyl films up to 8 mm long and 50 μm thick have been obtained for the first time by the solvent‒antisolvent growth method. The films have been grown both on the liquid–air interface and in the solution bulk. The morphology, surface quality, and thickness of crystal films have been investigated by the optical, laser confocal, and atomic force microscopies. The structure of the para-quaterphenyl single crystal at room temperature has been refined by X-ray diffraction analysis. The formation and growth mechanisms of crystal films on the liquid–air interface have been discussed. The opticalabsorption and photoluminescence spectra of the solutions and crystal samples have been investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mining the human urine proteome for monitoring renal transplant injury

The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

Environmental Molecular Sciences Laboratory↗

Molecular-resolution imaging of ice crystallized from liquid water by cryogenic liquid-cell TEM

Despite the ubiquity of ice, a molecular-resolution image of nanoscopic defects or microstructures in ice crystallized from liquid water has never been obtained. This is mainly due to the difficulties in preparing and preserving crystalline ice samples that can survive under high-resolution imaging conditions. Here, we report the stabilization and Å-resolution electron imaging of ice Ih crystallized from liquid water by developing cryogenic liquid-cell transmission electron microscopy (CRYOLIC-TEM). We combine lattice mapping with molecular dynamics simulations to reveal that ice formation is highly tolerant to nanoscale defects such as misoriented subdomains and trapped gas bubbles, which are stabilized by molecular-scale structural motifs. Importantly, bubble surfaces adopt low-energy nanofacets and create negligible strain fields in the surrounding crystal. These bubbles can dynamically nucleate, grow, migrate, dissolve, and coalesce under electron irradiation and be monitored in situ near a steady state. This work improves our understanding of water crystallization behaviors at a molecular spatial resolution.

Materials science↗

Understanding Fracture Aperture and Permeability Evolution due to Carbonate Mineralization Utilizing 3D Printing

Caprock formations are a crucial part of subsurface-engineered systems. Composed largely of shale, caprocks act as natural barriers that prevent the upward migration of fluids, thereby ensuring the containment of stored substances in subsurface formations. Fractures in these formations are potential leakage pathways for stored fluids. Mineral precipitation reactions in these fractures, particularly calcite, can significantly restrict the fluid permeability, reducing leakage potential. However, predictive capabilities of mineral precipitation in fractures and associated permeability evolution are limited due to a lack of fundamental understanding of such reactions in natural samples, complicated by mineral heterogeneity and the complexity of the fracture structure. In this study, 3D-printed fracture samples are used to understand the impact of carbonate mineralization on fracture aperture and permeability evolution. Samples were printed using a digital light processing (DLP) 3D printer and commercial liquid resin. Calcite precipitation was first tested on printed 2D films before conducting plug flow column experiments aimed to understand fracture permeability changes due to mineral precipitation. Contact angle measurement and Fourier transform infrared (FTIR) spectroscopy on printed 2D films show evidence of a substantial amount of surface energy for calcite nucleation and precipitation. Surface topography analysis of printed fractured surfaces reveals comparable values, highlighting the high replicability of the printed samples. During the column experiments, the permeability reduces exponentially due to a decrease in fracture aperture. Reductions in fracture aperture estimated from effluent concentration and 3D X-ray computed tomography (CT) show comparable results. Moreover, 3D X-ray CT images suggest the impact of local flow velocities on precipitation. The insights gained from this research contribute to a deeper understanding of the permeability evolution due to carbonate mineralization in caprock formations.

3D printing↗

Synchrotron-based X-ray fluorescence imaging and elemental mapping from biological samples

The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of {approx}10 {mu}m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a 'step-and-repeat' mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗