Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Imaging the behavior of molecules in biological systems: Breaking the 3D speed barrier with 3D multi-resolution microscopy

Here, the overwhelming effort in the development of new microscopy methods has been focused on increasing the spatial and temporal resolution in all three dimensions to enable the measurement of the molecular scale phenomena at the heart of biological processes. However, there exists a significant speed barrier to existing 3D imaging methods, which is associated with the overhead required to image large volumes. This overhead can be overcome to provide nearly unlimited temporal precision by simply focusing on a single molecule or particle via real-time 3D single-particle tracking and the newly developed 3D Multi-resolution Microscopy (3D-MM). Here, we investigate the optical and mechanical limits of real-time 3D single-particle tracking in the context of other methods. In particular, we investigate the use of an optical cantilever for position sensitive detection, finding that this method yields system magnifications of over 3000×. We also investigate the ideal PID control parameters and their effect on the power spectrum of simulated trajectories. Taken together, these data suggest that the speed limit in real-time 3D single particle-tracking is a result of slow piezoelectric stage response as opposed to optical sensitivity or PID control.

3D Multi-resolution microscopy↗

Fourier amplitude sensitivity test applied to dynamic combined finite-discrete element methods-based simulations

Fracture propagation plays a key role for a number of applications of interest to the scientific community, from dynamic fracture processes like spallation and fragmentation in metals to failure of ceramics, airplane wings, etc. Simulations of material deformation and fracture propagation rely on accurate knowledge of material characteristics such as material strength and the amount of energy being dissipated during the fracture process. Within the combined finite-discrete element method (FDEM) framework material fracture behavior is typically described through a parametrized softening curve, which defines a stress-strain relationship unique to each material. We apply the Fourier amplitude sensitivity test to explore how each of these parameters influences the simulated damage processes and to determine the key input parameters that have the most impact on the model response. We present several sensitivity numerical experiments for the simulation of a split Hopkinson pressure bar (SHPB) test for weathered granite samples using different combinations of model parameters. We validate the obtained results against SHPB experimental data. The experiments show that the model is mostly sensitive to parameters related to tensile and shear strengths, even in the presence of other parameter perturbations. Lastly, the results suggest that the specification of tensile and shear strengths at the interfaces dominate the stress-time history of the FDEM simulation of SHPB test.

36 MATERIALS SCIENCE↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Poisson equation method for prescribing fully developed non-Newtonian inlet conditions for computational fluid dynamics simulations in models of arbitrary cross-section

Prescribing inlet boundary conditions for computational fluid dynamics (CFD) simulations of internal flow in complex geometries such as anatomical vascular models is challenging. In the absence of patient-specific inlet velocity data, a common approach for long blood vessels is to assume that the inlet flow is fully developed. In vessels of irregular cross section, however, prescribing fully developed conditions is complicated due to the lack of a general closed-form analytical solution. In this study, we develop a simple Poisson equation method for prescribing fully developed inlet conditions for the flow of either Newtonian or non-Newtonian fluids in CFD models of arbitrary cross-section. We first derive the generalized Poisson equation for fully developed flow of a non-Newtonian fluid and we then develop and verify a methodology for numerically computing the solution on any planar boundary domain. In addition, we develop a simple extension of the method for prescribing a non-orthogonal inlet velocity that represents fully developed flow from an upstream tube that is connected to the CFD inlet at a non-orthogonal angle. This may be used to investigate a common source of uncertainty in CFD simulations of internal flow that is due to a lack of information concerning the exact streamwise flow direction at the inlets. Comparison to several Newtonian and non-Newtonian benchmark verification solutions shows the method to be extremely accurate. As a practical demonstration case, we use the method to prescribe fully developed conditions on multiple non-circular inlets for the non-Newtonian flow of blood in a patient-specific model of the inferior vena cava (IVC). Finally, we further demonstrate the utility of the method by performing a sensitivity study using the patient-specific IVC model, wherein we investigate the influence of inlet velocity flow direction on the non-Newtonian IVC hemodynamics. Given its simplicity and computational efficiency, the method is shown to be far superior to alternative approaches for prescribing fully developed inlet conditions in such complicated geometries. In conclusion, to facilitate the adoption of our Poisson equation method, we have distributed our OpenFOAM source code and the associated test cases from this study as open-source software.

97 MATHEMATICS AND COMPUTING↗

A robust and efficient approach to detect 3D rectal tubes from CT colonography

Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE FRACTAL DENSITY STRUCTURE IN SUPERSONIC ISOTHERMAL TURBULENCE: SOLENOIDAL VERSUS COMPRESSIVE ENERGY INJECTION

In a systematic study, we compare the density statistics in high-resolution numerical experiments of supersonic isothermal turbulence, driven by the usually adopted solenoidal (divergence-free) forcing and by compressive (curl-free) forcing. We find that for the same rms Mach number, compressive forcing produces much stronger density enhancements and larger voids compared to solenoidal forcing. Consequently, the Fourier spectra of density fluctuations are significantly steeper. This result is confirmed using the {delta}-variance analysis, which yields power-law exponents {beta} {approx} 3.4 for compressive forcing and {beta} {approx} 2.8 for solenoidal forcing. We obtain fractal dimension estimates from the density spectra and {delta}-variance scaling, and by using the box counting, mass size, and perimeter area methods applied to the volumetric data, projections, and slices of our turbulent density fields. Our results suggest that compressive forcing yields fractal dimensions significantly smaller compared to solenoidal forcing. However, the actual values depend sensitively on the adopted method, with the most reliable estimates based on the {delta}-variance, or equivalently, on Fourier spectra. Using these methods, we obtain D {approx} 2.3 for compressive and D {approx} 2.6 for solenoidal forcing, which is within the range of fractal dimension estimates inferred from observations (D {approx} 2.0-2.7). The velocity dispersion to size relations for both solenoidal and compressive forcings obtained from velocity spectra follow a power law with exponents in the range 0.4-0.5, in good agreement with previous studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Comparative Study of Distribution System Parameter Estimation Methods

In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

distribution system analysis↗

Identification of contact and respiratory sensitizers according to IL-4 receptor α expression and IL-2 production

Identification of allergenic chemicals is an important occupational safety issue. While several methods exist to identify contact sensitizers, there is currently no validated model to predict the potential of chemicals to act as respiratory sensitizers. Previously, we reported that cytometry analysis of the local immune responses induced in mice dermally exposed to the respiratory sensitizer trimellitic anhydride (TMA 10%) and contact sensitizer dinitrochlorobenzene (DNCB 1%) could identify divergent expression of several immune parameters. The present study confirms, first, that IgE-positive B cells, MHC class II molecules, interleukin (IL)-2, IL-4 and IL-4Rα can differentiate the allergic reactions caused by high doses of strong respiratory (TMA, phthalic anhydride and toluene diisocyanate) and contact sensitizers (DNCB, dinitrofluorobenzene and oxazolone). The second part of the study was designed to test the robustness of these markers when classing the weakly immunogenic chemicals most often encountered. Six respiratory allergens, including TMA (2.5%), five contact allergens, including DNCB (0.25%), and two irritants were compared at doses of equivalent immunogenicity. The results indicated that IL-4Rα and IL-2 can be reliably used to discriminate sensitizers. Respiratory sensitizers induced markedly higher IL-4Rα levels than contact allergens, while irritants had no effect on this parameter. Inversely, contact allergens tended to induce higher percentages of IL-2{sup +}CD8{sup +} cells than respiratory allergens. In contrast, the markers MHC-II, IgE and IL-4 were not able to classify chemicals with low immunogenic potential. In conclusion, IL-4Rα and IL-2 have the potential to be used in classifying a variety of chemical allergens. -- Highlights: ► Identification of chemical allergens is an important occupational safety issue. ► There is currently no model to predict the potential of chemicals to induce asthma. ► We analyze immune responses induced in mice by a variety of chemical sensitizers. ► IL-2 and IL-4R alpha show potential to discriminate between both types of allergens. ► This method could be applied to highly and weakly immunogenic chemicals.

60 APPLIED LIFE SCIENCES↗

Structural studies of the disorder and phase transitions in the double perovskite Sr{sub 2}YTaO{sub 6}

The evolution of the crystal structure of the double perovskite Sr{sub 2}YTaO{sub 6} from room temperature to 1250 {sup o}C has been studied using powder neutron and synchrotron X-ray diffraction. At room temperature Sr{sub 2}YTaO{sub 6} crystallises in a monoclinic superstructure with the space group P2{sub 1}/n. The tilting of the octahedra evident in the room temperature structure is progressively lost on heating, resulting in a sequence of phase transitions that ultimately yields the cubic structure in space group Fm3m. The high temperature tetragonal and cubic phases are characterised by strongly anisotropic displacements of the anions. The amount of defects in the crystal structure of Sr{sub 2}YTaO{sub 6} is found to be sensitive to the preparative method. - Graphical abstract: Sr{sub 2}YTaO{sub 6} undergoes a sequence of phase transitions upon heating associated with the removal of the tilting of the octahedral. The number of defects in the structure is sensitive to the preparative conditions.

36 MATERIALS SCIENCE↗

Optimal Voltage Regulation for Unbalanced Distribution Networks Considering Distributed Energy Resources

With increasing penetration of distributed generation in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative quadratic constrained quadratic programming model to minimize voltage deviations and maximize distributed energy resource (DER) active power output in a three phase unbalanced distribution system is developed. The optimization model is based on the linearized sensitivity coefficients between controlled variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DERs). To avoid the oscillation of solution when it is close to the optimum, a golden search method is introduced to control the step size. Numerical simulations on modified IEEE 13 nodes test feeders show the efficiency of the proposed model. Compared to the results solved by heuristic search (harmony algorithm), the proposed model converges quickly to the global optimum.

distributed energy resources↗

Incorporating Quantitative Single Photon Emission Computed Tomography into Radiation Therapy Treatment Planning for Lung Cancer: Impact of Attenuation and Scatter Correction on the Single Photon Emission Computed Tomography-Weighted Mean Dose and Functional Lung Segmentation

Purpose: To assess the impact of attenuation and scatter corrections on the calculation of single photon emission computed tomography (SPECT)-weighted mean dose (SWMD) and functional volume segmentation as applied to radiation therapy treatment planning for lung cancer. Methods and Materials: Nine patients with lung cancer underwent a SPECT lung perfusion scan. For each scan, four image sets were reconstructed using the ordered subsets expectation maximization method with attenuation and scatter corrections ranging from none to a most comprehensive combination of attenuation corrections and direct scatter modeling. Functional volumes were segmented in each reconstructed image using 10%, 20%, ..., 90% of maximum SPECT intensity as a threshold. Systematic effects of SPECT reconstruction methods on treatment planning using functional volume were studied by calculating size and spatial agreements of functional volumes, and V{sub 20} for functional volume from actual treatment plans. The SWMD was calculated for radiation beams with a variety of possible gantry angles and field sizes. Results: Functional volume segmentation is sensitive to the particular method of SPECT reconstruction used. Large variations in functional volumes, as high as >50%, were observed in SPECT images reconstructed with different attenuation/scatter corrections. However, SWMD was less sensitive to the type of scatter corrections. SWMD was consistent within 2% for all reconstructions as long as computed tomography-based attenuation correction was used. Conclusion: When using perfusion SPECT images during treatment planning optimization/evaluation, the SWMD may be the preferred figure of merit, as it is less affected by reconstruction technique, compared with threshold-based functional volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unraveling the Structural Sensitivity of Metal Catalysts in Ethylene Hydroformylation: Insights from Theory and Experiments

Here, in this study, we combined experimental and theoretical methods to investigate the structural sensitivity of metal catalysts in the ethylene hydroformylation reaction. Among Rh, Pt, Ir, Ni, Au, Ag, Pd, and Cu catalysts studied using experimental and theoretical methods, Rh showed the highest selectivity toward the C-C coupling product from CO and C 2 H 5 (i.e., C 2 H 5 CHO). The results from DFT and microkinetic simulations revealed that the activation energy barrier for C-C coupling is lowest on the Rh nanocluster, which explains the experimentally observed highest C 2 H 5 CHO selectivity on the Rh catalyst. Furthermore, DFT results demonstrated that the sites located on the flat surfaces of nanoparticles primarily promote the hydrogenation reaction, leading to the formation of undesired C 2 H 6 . In contrast, undercoordinated edge and corner sites of the nanocluster promote the C-C coupling reaction. Thus, our results illustrate that the selectivity toward C 3 oxygenates in ethylene hydroformylation reaction can be steered by tuning the size of Rh nanoparticles (the best-performing catalyst) to optimize the active (edge and corner) sites that preferentially promote the C-C coupling reaction.

58 GEOSCIENCES↗

Photoluminescence Probes Ion Insertion into Amorphous and Crystalline Regions of Organic Mixed Conductors

Abstract Organic mixed ionic‐electronic conductors (OMIECs) have emerged as promising materials for a wide range of next‐generation technologies, including bioelectronics and neuromorphic computing. The performance of these materials depends on the transport of ions through the polycrystalline polymer matrix as well as how the distribution of ions and polarons in crystalline and amorphous regions impacts electronic transport. However, it is often challenging to distinguish whether ions enter crystalline or amorphous regions. In this work, steady‐state and time‐resolved photoluminescence (PL) spectroelectrochemistry is used to probe initial ion insertion in crystalline and amorphous regions of the OMIEC material poly(3‐[2‐[2‐(2‐methoxyethoxy)ethoxy]ethyl]thiophene ‐2,5‐diyl) (P3MEEET) as a function of applied voltage. It is found that PL spectroelectrochemistry reports on the initial stages of electrochemical doping through the quenching of PL emission. By distinguishing between amorphous and crystalline contributions to the PL spectrum, ion insertion in crystalline and amorphous regions as a function of voltage is tracked. It is found that PL spectroelectrochemistry is much more sensitive to the initial injection of ions than complementary methods, highlighting its potential as a sensitive tool for interrogating ion injection in OMIECs.

Collins, Garrett W.↗

Effects of the method of active site characterization for determining structure-sensitivity in Ag-catalyzed ethylene epoxidation

We report catalysts have been prepared on a low surface area α-Al 2 O 3 support used commercially for previous generation olefin epoxidation catalysts. Prescreening of the low surface area alumina (0.73 m 2 /g) indicated the absence of acid catalyzed isomerization of EO at an evaluation temperature of 210 °C. A 0.1 wt% Ag base material synthesized by incipient wetness impregnation of AgNO 3 was used as a base material for electroless deposition (ED) of additional Ag to increase particle sizes by controlled reduction of Ag + directly onto the preexisting Ag surface to form weight loadings between 0.3 and 5.0 wt% metal. A 12 wt% Ag/α-Al 2 O 3 using Ag 2 C 2 O 4 as the Ag precursor was also prepared to compare performance of the ED samples with a catalyst more typical of industrial formulations. Characterization by SEM, STEM, and hydrogen titration of oxygen precovered Ag characterized before and after catalytic evaluation indicated that microscopy is required to accurately represent distributions of Ag particle sizes, but H 2 titration of O-precovered Ag gives the best representation of active sites since it directly counts the number of Ag surface sites. Larger particles >100 nm are resistant to both Ag sintering and carbon foulant; TOF values were relatively insensitive to particle size with only a 2.2 × difference between the best and worst performing samples. Selectivity, which is not a function of TOF, shows the most significant structure sensitivity effect where particle sizes follow the trend 67 nm ≈ 92 nm (58% EO) < 157 nm (67% EO) < 211–542 nm (73% EO). The lower EO selectivities were also correlated with increased fouling for the smaller Ag sizes, suggesting that more strongly bound EO precursor(s) leads to combustion and CO 2 /H 2 O formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity of the Properties of Ruthenium “Blue Dimer” to Method, Basis Set, and Continuum Model

The ruthenium “blue dimer” [(bpy)2RuIIIOH2]2O4+ is best known as the first well-defined molecular catalyst for water oxidation. It has been subject to numerous computational studies primarily employing density functional theory. However, those studies have been limited in the functionals, basis sets, and continuum models employed. The controversy in the calculated electronic structure and the reaction energetics of this catalyst highlights the necessity of benchmark calculations that explore the role of density functionals, basis sets, and continuum models upon the essential features of blue-dimer reactivity. In this paper, we report Kohn-Sham complete basis set (KS-CBS) limit extrapolations of the electronic structure of “blue dimer” using GGA (BPW91 and BP86), hybrid-GGA (B3LYP), and meta-GGA (M06-L) density functionals. The dependence of solvation free energy corrections on the different cavity types (UFF, UA0, UAHF, UAKS, Bondi, and Pauling) within polarizable and conductor-like polarizable continuum model has also been investigated. The most common basis sets of double-zeta quality are shown to yield results close to the KS-CBS limit; however, large variations are observed in the reaction energetics as a function of density functional and continuum cavity model employed.

Environmental Molecular Sciences Laboratory↗