Search NASA⌕ Search

SEARCH · Search NASA

Results for “usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Measuring and Understanding the Energy Use Signatures of a Bank Building

The Pacific Northwest National Laboratory measured and analyzed the energy end-use patterns in a bank building located in the north-eastern United States. This work was performed in collaboration with PNC Financial Service Group under the US DOE’s Commercial Building Partnerships Program. This paper presents the metering study and the results of the metered data analysis. It provides a benchmark for the energy use of different bank-related equipments. The paper also reveals the importance of metering in fully understanding building loads and indentifying opportunities for energy efficiency improvements that will have impacts across PNC’s portfolio of buildings and were crucial to reducing receptacle loads in the design of a net-zero bank branches. PNNL worked with PNC to meter a 4,000 ft2 bank branch in the state of Pennsylvania. 71 electrical circuits were monitored and 25 stand-alone watt-hour meters were installed at the bank. These meters monitored the consumption of all interior and exterior lighting, receptacle loads, service water heating, and the HVAC rooftop unit at a 5-minute sampling interval from November 2009 to November 2010. A total of over 8 million data records were generated, which were then analyzed to produce the end-use patterns, daily usage profiles, rooftop unit usage cycles, and inputs for calibrating the energy model of the building.

ASHRAE↗

Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings (Interim Final Report)

Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $\$$4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single-family homes. HESP provided cash incentives and financing opportunities to owners of one-to four-unit structures, which resulted in thousands of energy assessments and whole-house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium-sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trust’s MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR® Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building— all at no cost to the building owner. The ERP is developed by a program partner using either the Trust’s approved modeling or prescriptive tools; it provides detailed information about the current energy related conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self-sustaining, market-driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily units—such as Portland, Lewiston- Auburn, Bangor, and Augusta—MEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trust’s successful HESP for single-family residences. MEP offers significant incentives for building owners to participate in the upgrade program. Wholebuilding benchmarking services are available to most multifamily housing buildings free of charge. The service provides the building owner with an assessment of the building's current energy efficiency as compared to other multifamily buildings on a national scale, establishes a baseline to measure future improvements, and enables owners to track monthly energy consumption using the ENERGY STAR Portfolio Manager. Once the benchmarking process is complete, the program links building owners with approved program partners (e.g., energy professionals, home performance contractors) to identify and implement specific energy-saving opportunities in the building. Program partners can also provide project quotes with estimated financing incentives and payback period calculations that enable building owners to make informed decisions. What's more, the Trust provides two financial incentives for successful completion of program milestones. The first is a per-unit incentive for completion of an approved ERP (i.e., $\$$100 per unit if a prescriptive path is followed, and $\$$200 per unit for a modeled ERP). Upon final inspection of the installed project scope of work, an incentive of $\$$1,400 per unit or 50% of installed cost—whichever is less—is paid. The Trust originally established a $\$$1 million loan-loss reserve fund (LLRF) to further enhance financing opportunities for qualified multifamily building owners. This funding mechanism was designed to connect building owners with lenders that retain the mortgages for their properties and encourages the lenders to offer financing for energy efficiency improvements. However, there has been no interest in the LLRF and therefore the LLRF has been reduced. Ultimately, MEP plans to build an online tool for building owners to assess opportunities to make upgrades in their multifamily units. The tool will include a performance rating system to provide a way for building owners to more easily understand energy use in their building, and how it could be improved with energy efficiency upgrades. Prospective tenants will also be able to use the rating system to make informed decisions about where to rent. Furthermore, the rating can be incorporated into real estate listings as a way for prospective home buyers and the real estate financial community to evaluate a home's operating costs. The Trust’s MEP has identified the state's most experienced energy professionals, vendors, suppliers, and contractors that install energy efficiency equipment in the multifamily sector to be qualified program partners. To be eligible for partnership, energy assessment professionals and contractors are required to have demonstrated experience in the multifamily sector and hold associated professional certifications, such as Building Operator Certification (BOC), Certified Energy Manager (CEM), Professional Engineer (PE), or Building Performance Institute (BPI) Multifamily Building Analyst. Widespread program interest has enabled the Trust to redirect funds that might otherwise be needed for program promotion to building capacity through contractor training. In addition to boosting professional training and certification opportunities, MEP teaches its partners how to market the multifamily program to prospective multifamily homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

III-Nitride Nanowire Lasers

In recent years there has been a tremendous interest in nanoscale optoelectronic devices. Among these devices are semiconductor nanowires whose diameters range from 10-100 nm. To date, nanowires have been grown using many semiconducting material systems and have been utilized as light emitting diodes, photodetectors, and solar cells. Nanowires possess a relatively large index contrast relative to their dielectric environment and can be used as lasers. A key gure of merit that allows for nanowire lasing is the relatively high optical con nement factor. In this work, I discuss the optical characterization of 3 types of III-nitride nanowire laser devices. Two devices were designed to reduce the number of lasing modes to achieve singlemode operation. The third device implements low-group velocity mode lasing with a photonic crystal constructed of an array of nanowires. Single-mode operation is necessary in any application where high beam quality and single frequency operation is required. III-Nitride nanowire lasers typically operate in a combined multi-longitudinal and multi-transverse mode state. Two schemes are introduced here for controlling the optical modes and achieving single-mode op eration. The rst method involves reducing the diameter of individual nanowires to the cut-o condition, where only one optical mode propagates in the wire. The second method employs distributed feedback (DFB) to achieve single-mode lasing by placing individual GaN nanowires onto substrates with etched gratings. The nanowire-grating substrate acted as a distributed feedback mirror producing single mode operation at 370 nm with a mode suppression ratio (MSR) of 17 dB. The usage of lasers for solid state lighting has the potential to further reduce U.S. lighting energy usage through an increase in emitter e ciency. Advances in nanowire fabrication, speci cally a two-step top-down approach, have allowed for the demonstration of a multi-color array of lasers on a single chip that emit vertically. By tuning the geometrical properties of the individual lasers across the array, each individual nanowire laser produced a di erent emission wavelength yielding a near continuum of laser wavelengths. I successfully fabricated an array of emitters spanning a bandwidth of 60 nm on a single chip. This was achieved in the blue-violet using III-nitride photonic crystal nanowire lasers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Existing Whole-House Solutions Case Study: Evaluating Energy Savings in All-Electric Public Housing in the Pacific Northwest

This project analyzes the cost effectiveness of energy-saving measures installed by a large public housing authority in Salishan, and evaluates those solutions to improve efficiency of affordable housing for new and existing homes. Research focuses on the modeled and measured energy usage of the first six phases of construction, and compares the energy usage of those phases to phase 7.

BA-PIRC↗

Climate Science Performance, Data and Productivity on Titan

Climate Science models are flagship codes for the largest of high performance computing (HPC) resources, both in visibility, with the newly launched Department of Energy (DOE) Accelerated Climate Model for Energy (ACME) effort, and in terms of significant fractions of system usage. The performance of the DOE ACME model is captured with application level timers and examined through a sizeable run archive. Performance and variability of compute, queue time and ancillary services are examined. As Climate Science advances in the use of HPC resources there has been an increase in the required human and data systems to achieve programs goals. A description of current workflow processes (hardware, software, human) and planned automation of the workflow, along with historical and projected data in motion and at rest data usage, are detailed. The combination of these two topics motivates a description of future systems requirements for DOE Climate Modeling efforts, focusing on the growth of data storage and network and disk bandwidth required to handle data at an acceptable rate.

Mayer, Benjamin W↗

Achieving Actionable Results from Available Inputs: Metamodels Take Building Energy Simulations One Step Further

Modeling commercial building energy usage can be a difficult and time-consuming task. The increasing prevalence of optimization algorithms provides one path for reducing the time and difficulty. Many use cases remain, however, where information regarding whole-building energy usage is valuable, but the time and expertise required to run and post-process a large number of building energy simulations is intractable. A relatively underutilized option to accurately estimate building energy consumption in real time is to pre-compute large datasets of potential building energy models, and use the set of results to quickly and efficiently provide highly accurate data. This process is called metamodeling. In this paper, two case studies are presented demonstrating the successful applications of metamodeling using the open-source OpenStudio Analysis Framework. The first case study involves the U.S. Department of Energy's Asset Score Tool, specifically the Preview Asset Score Tool, which is designed to give nontechnical users a near-instantaneous estimated range of expected results based on building system-level inputs. The second case study involves estimating the potential demand response capabilities of retail buildings in Colorado. The metamodel developed in this second application not only allows for estimation of a single building's expected performance, but also can be combined with public data to estimate the aggregate DR potential across various geographic (county and state) scales. In both case studies, the unique advantages of pre-computation allow building energy models to take the place of topdown actuarial evaluations. This paper ends by exploring the benefits of using metamodels and then examines the cost-effectiveness of this approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring

Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report by Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.

Hernandez Jimenez, Jarilyn M↗

Impact of Active Climate Control Seats on Energy Use, Fuel Use, and CO2 Emissions

A project was developed through collaboration between Gentherm and NREL to determine the impact of climate control seats for light-duty vehicles in the United States. The project used a combination of experimentation and analysis, with experimental results providing critical input to the analysis process. First, outdoor stationary vehicle testing was performed at NREL's facility in Golden, CO using multiple occupants. Two pre-production Ford Focus electric vehicles were used for testing; one containing a standard inactive seat and the second vehicle containing a Gentherm climate control seat. Multiple maximum cool-down and steady-state cooling tests were performed in late summer conditions. The two vehicles were used to determine the increase in cabin temperature when using the climate control seat in comparison to the baseline vehicle cabin temperature with a standard seat at the equivalent occupant whole-body sensation. The experiments estimated that on average, the climate control seats allowed for a 2.61 degrees Celsius increase in vehicle cabin temperature at equivalent occupant body sensation compared to the baseline vehicle. The increased cabin air temperature along with their measured energy usage were then used as inputs to the national analysis process. The national analysis process was constructed from full vehicle cabin, HVAC, and propulsion models previously developed by NREL. In addition, three representative vehicle platforms, vehicle usage patterns, and vehicle registration weighted environmental data were integrated into the analysis process. Both the baseline vehicle and the vehicle with climate control seats were simulated, using the experimentally determined cabin temperature offset of 2.61degrees Celsius and added seat energy as inputs to the climate control seat vehicle model. The U.S. composite annual fuel use savings for the climate control seats over the baseline A/C system was determined to be 5.1 gallons of gasoline per year per vehicle, corresponding to 4.0 grams of CO2/mile savings. Finally, the potential impact of 100 percent adoption of climate control seats on U.S. light-duty fleet A/C fuel use was calculated to be 1.3 billion gallons of gasoline annually with a corresponding CO2 emissions reduction of 12.7 million tons. Direct comparison of the impact of the CCS to the ventilated seat off-cycle credit was not possible because the NREL analysis calculated a combined car/truck savings and the baseline A/C CO2 emissions were higher than EPA. To enable comparison, the CCS national A/C CO2 emissions were split into car/truck components and the ventilated seat credit was scaled up. The split CO2 emissions savings due to the CCS were 3.5 g/mi for a car and 4.4 g/mi for a truck. The CCS saved an additional 2.0 g/mi and 2.5 g/mi over the adjusted ventilated seat credit for a car and truck, respectively.

30 DIRECT ENERGY CONVERSION↗

QoS aware balancing in data centers

One embodiment of the present invention provides a system for balancing loads between two physical resources. During operation, for each physical resource, the system establishes resource-usage models for a plurality of jobs that share the physical resource, identifies quality-of-service (QoS) levels associated with the jobs, and computes a QoS balance point for the physical resource based on the resource-usage models and the QoS ratings. The QoS balance point indicates a rating of QoS, above which substantial resource provisioning is required. In response to detecting a difference between a first QoS balance point associated with a first physical resource and a second QoS balance point associated with a second physical resource, the system identifies one or more jobs to be moved between the first and second physical resources such that the difference between the first and the second QoS balance points is reduced.

Greene, Daniel H.↗

System and method for energy reduction based on history of reliability of a system

A system and method for managing operating parameters within a system for optimal power and reliability are described. A device includes a functional unit and a corresponding reliability evaluator. The functional unit provides reliability information to one or more reliability monitors, which translate the information to reliability values. The reliability evaluator determines an overall reliability level for the system based on the reliability values. The reliability monitor compares the actual usage values and the expected usage values. When system has maintained a relatively high level of reliability for a given time interval, the reliability evaluator sends an indication to update operating parameters to reduce reliability of the system, which also reduces power consumption for the system.

Sadowski, Greg↗

WLCG Web Proxy Auto Discovery for Dynamically Created Web Proxies

The WLCG Web Proxy Auto Discovery (WPAD) service provides a convenient mechanism for jobs running anywhere on the WLCG to dynamically discover web proxy cache servers that are nearby. The web proxy caches are general purpose for a number of different http applications, but different applications have different usage characteristics and not all proxy caches are engineered to work with the heaviest loads. For this reason, the initial sources of information for WLCG WPAD were the static configurations that ATLAS and CMS maintain for the Conditions data that they read through the Frontier Distributed Database system, which is the most demanding popular WLCG application for web proxy caches. That works well for use at traditional statically defined WLCG sites, but now that usage of commercial clouds is increasing, there is also a need for web proxy caches to dynamically register themselves as they are created. A package called Shoal had already been created to manage dynamically created web proxy caches. This paper describes the integration of the Shoal package into the WLCG WPAD system, such that both statically and dynamically created web proxy caches can be located from a single source. It also describes other improvements to the WLCG WPAD system since the last CHEP publication.

Dykstra, Dave↗

Quantifying Technical Diversity Benefits of Wind as a Distributed Energy Resource

Distributed energy resources are increasingly used in power distribution systems and microgrids to supply cost competitive power, improve resilience, and provide a host of grid services. Diversifying variable renewable resources (e.g., by combining wind with solar) can increase energy usage efficiency and improve system resilience. However, when grid optimization and resilience studies consider multiple renewable resources, diversity benefits are usually captured only implicitly in the results of location-specific economic optimization. In this paper, metrics are introduced to express the technical value of resource diversity independent of jurisdiction-specific market structures. Specifically, marginal energy usage efficiency metrics are developed to quantify the ability of new distributed generation to produce useful energy and an incremental sustainable ride through metric is developed to express improvement in grid outage ride through capability. While there are economic implications for each of these metrics, the metrics themselves are technically-driven and could be used as components of a technical figure of merit that could be used to inform policy actions, such as development of resource-specific incentives and time-of-use tariff designs. Each of these metrics is demonstrated using balance-of-energy simulations that highlight the benefits of improving resource diversity.

Reiman, Andrew P.↗

Engineering an increase in ethanol production by altering cofactor specificity

The present invention provides for the manipulation of cofactor usage in a recombinant host cell to increase the formation of desirable products. In some embodiments, the invention provides for a recombinant microorganism comprising a mutation in one or more native enzymes such that their cofactor specificity is altered in such a way that overall cofactor usage in the cell is balanced for a specified pathway and there is an increase in a specific product formation within the cell. In some embodiments, endogenous enzymes are replaced by enzymes with an alternate cofactor specificity from a different species.

09 BIOMASS FUELS↗

Predictive valve control system

A pressure control system may include a plurality of inflatable objects, each of the inflatable objects having a respective pressure sensor and a respective inflation valve, wherein each of the inflation valves has a behavior profile predictive of an amount of current used by the valve when operated. A valve controller of the system may have a pressure management circuit that receives information from the pressure sensors and is configured to automatically maintain a respective selected pressure in each of the inflatable objects by issuing commands to operate the inflation valves. An electrical current management circuit of the valve controller may be configured to predict, based on the valve behavior profiles, what effect the command would have on a total current usage, when executed, and automatically prevent any command that would cause the total current usage to exceed a maximum allowable current.

Piraner, Alexander↗

Improving scalability of electronic structure code for molecular simulations in the presence of environment

A scalable density functional electronic code with Gaussian basis set, called UTEP-NRLMOL, is developed to perform simulations of molecular systems in the presence of the environment with particular attention to the memory requirements. In the electronic structure calculations, the memory and computation time are proportional to the number of atoms. Memory requirements for density functional calculations scale as N*N, where N is the number of atoms. While the recent advances in HPC offer platforms with large numbers of cores, the limited amount of memory available on a given node and poor scalability of the electronic structure codes hinder their efficient usage of these platforms. We have introduced new scaling and parallelization paradigms using MPI-3 shared-memory functionality combined with usage of sparse algebra and storage of matrices in sparse format. This extends the range of applicability of the UTEP-NRLMOL code to large systems over 10,000 atoms, or using up to 67,000 basis functions, and making use of HPC architectures using over 6,000 processors utilizing all available cores. We have also interfaced code with effective fragment potential and polarizable continuum model libraries. The code was used in simulations of several applications which are published in reputed scientific journals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗