Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated circuits.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

3D design activities at Fermilab: Opportunities for physics

Fermilab began exploring the technologies for vertically integrated circuits (also commonly known as 3D circuits) in 2006. These technologies include through silicon vias (TSV), circuit thinning, and bonding techniques to replace conventional bump bonds. Since then, the interest within the High Energy Physics community has grown considerably. This paper will present an overview of the activities at Fermilab over the last 3 years which have helped spark this interest.

43 PARTICLE ACCELERATORS↗

Student Support for EIPBN 2010 Conference

The 54 th International Conference on Electron, Ion and Photon Beam Technology and Nanofabrication, 2010, held at the Egan Convention Center and Hilton in Anchorage, Alaska, June 1 to 4, 2010 was a great success in large part because financial support allowed robust participation from students. The conference brought together 444 engineers and scientists from industries and universities from all over the world to discuss recent progress and future trends. Among the emerging technologies that are within the scope of EIPBN is Nanofabrication for Energy Sources along with nanofabrication for the realization of low power integrated circuits. Every year, EIPBN provides financial support for students to attend the conference. The students gave oral and poster presentations of their research and many published peer reviewed articles in a special conference issue of the Journal of Vacuum Science and Technology B. The Department of Energy Office of Basic Energy Sciences supported 20 students from US universities with a $\$$15,000.

36 MATERIALS SCIENCE↗

Processing Choices for Achieving Long Term IC Operation at 500° C

The prospects for beneficial infusion of integrated circuits (ICs) into previously inaccessible extreme-temperature application environments has increased with recent NASA Glenn demonstrations of 4H-SiC Junction Field Effect Transistor & Resistor (JFET-R) chips functioning for over a year at 500 °C in air ambient [1]. This paper focuses on fabrication process choices believed key to demonstrated 500 °C durability that must be considered when porting this uniquely durable IC capability into commercial foundry manufacturing.

SiC, JFET, Integrated Circuits, High-Temperature, ↗

Room Temperature Total-Ionizing Dose Testing of Glenn Research Center (GRC) 500 °C Durable 4H-SiC JFET IC Technology

The purpose of this testing was to obtain total ionizing dose (TID) information about custom-built research prototype silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) capable of prolonged operation in extremely high-temperature (500 degrees Centigrade) environments. The circuits included ring oscillators and operational amplifiers as well as individual n-channel JFETs. This technology is being considered for use in high temperature, high pressure applications such as Long-Lives Surface System Explorer (LLISSE). These devices were developed at NASA Glenn Research Center (GRC). Testing occurred from July 9th-July 13th, 2018.

Radiation↗

Magnetic measurements using array of integrated Hall sensors on the CASTOR tokamak

We have performed the first tests of 'integrated' Hall sensors (IHSs) in a tokamak in-vessel environment. IHS combines the sensing element together with the complex electronic circuitry on a single small chip. The on-chip integrated circuits provide stabilization of the supply voltage, output amplification, noise suppression, and elimination of temperature dependencies. Eight IHSs of A1322LUA type produced by Allegro MicroSystems, Inc. were mounted on a stainless steel ring symmetrically encircling the CASTOR plasmas in poloidal direction 10 mm outside the limiter radius. IHSs were oriented such that they measure the horizontal and vertical magnetic fields. We found out that these sensors qualify for in-vessel use of small to middle sized fusion devices where the radiation is not an issue and the temperature below 150 deg. C can be guaranteed. The main advantages over the traditional pickup coils are the smaller size and more straightforward interpretation of output without the need of rather cumbersome integration and drift removal procedure associated with the use of inductive loops. We successfully exploited the sensors for determination of vertical plasma displacement on CASTOR. This new diagnostic helped us to shed more light into long term observed discrepancy on CASTOR between vertical plasma displacement as deduced by standard magnetic and by nonmagnetic diagnostics (Langmuir probes, bolometers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medium power amplifiers covering 90 - 130 GHz for telescope local oscillators

This paper describes a set of power amplifier (PA) modules containing InP High Electron Mobility Transistor (HEMT) Monolithic Millimeter-wave Integrated Circuit (MMIC) chips. The chips were designed and optimized for local oscillator sources in the 90-130 GHz band for the Atacama Large Millimeter Array telescope. The modules feature 20-45 mW of output power, to date the highest power from solid state HEMT MMIC modules above 110 GHz.

coplanar waveguides↗

Progress Towards SiC ASICs for Extreme Temperature and Radiation Environments

This presentation describes development and demonstrations of semiconductor integrated circuits (ICs) and ceramic packaging that are arguably the most environmentally durable transistor electronics ever demonstrated. Silicon carbide (SiC) junction field effect transistor-resistor (JFET-R) ICs fabricated by NASA Glenn Research Center with two-level interconnect have successfully operated for over 1 year in 500 °C air-ambient, 60 days in 460 °C and 9.3 MPa pressure caustic Venus surface environment test chamber, and radiation exposure through 7 Mrad(Si) total ionizing dose (TID) and 86 MeV-cm2/mg heavy ion strikes. Furthermore, these ICs have also demonstrated operation from -190 °C to +812 °C (over 1000 °C temperature span) without significant change in signal (input /output) or power supply voltages. While the operating frequency and functional complexity is far below silicon-based ICs, these SiC application specific ICs (ASICs) are nevertheless becoming capable of providing unique and advantageous harsh-environment circuit functionality without cooling/sheltering overhead. With modest adjustments, the SiC JFET-R fabrication process is compatible with semiconductor mass-production tools and materials. As an initial step towards manufacture, a majority of processing steps to realize the next SiC JFET-R IC prototype wafer run have been outsourced to commercial foundry. It is expected that further upscaling combined with technology transfer to commercial production will lower investment and risk barriers to useful application deployment.

high temperature↗

Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XXI

This volume contains 12 sessions, 28 papers and 26 presentations on the following topics: Photonic Integrated Circuits and Plasmonic Sensing; Advancs in CBE Signature Modeling and Sensor Algorithms I; Standoff Sensing of CBRNE Hazards I; Standoff Sensing of CBRNE Hazards II; Advances in CBE Signature Modeling and Sensor Algorithms II; Biological Hazard Sensing; Chemical Hazard Sensing; Joint Session with Conferences 11390 and 11416: Spectroscopy for CBRNE Detection and Warning; Radiological and Nuclear Sensing; Explosive Material Sensing; Poster Session.

47 OTHER INSTRUMENTATION↗

The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing

The Maia detector system is engineered for energy dispersive x-ray fluorescence spectroscopy and elemental imaging at photon rates exceeding 10{sup 7}/s, integrated scanning of samples for pixel transit times as small as 50 {micro}s and high definition images of 10{sup 8} pixels and real-time processing of detected events for spectral deconvolution and online display of pure elemental images. The system developed by CSIRO and BNL combines a planar silicon 384 detector array, application-specific integrated circuits for pulse shaping and peak detection and sampling and optical data transmission to an FPGA-based pipelined, parallel processor. This paper describes the system and the underpinning engineering solutions.

43 PARTICLE ACCELERATORS↗

Delta Modulation Technique for Improving the Sensitivity of Monobit Subsamplers in Radar and Coherent Receiver Applications

This paper introduces a technique for improving the sensitivity of RF subsamplers in radar and coherent receiver applications. The technique, referred to herein as “delta modulation” (DM), feeds the time-average output of a monobit analog-to-digital converter (ADC) back to the ADC input, but with opposite polarity. Assuming pseudo-stationary modulation statistics on the sampled RF waveform, the feedback signal corrects for aggregate DC offsets present in the ADC that otherwise degrade ADC sensitivity. Two RF integrated circuits (RFICs) are designed to demonstrate the approach. One uses analog DM to create the feedback signal; the other uses digital DM to achieve the same result. A series of tests validates the designs. The dynamic time-domain response confirms the feedback loop’s basic operation. Measured output quantization imbalance, under noise-only input drive, significantly improves with the use of the DM circuit, even for large, deliberately induced DC offsets and wide temperature variation from -55°C to +85 °C. Examination of the corrected vs. uncorrected baseband spectrum under swept input signal-tonoise ratio (SNR) conditions demonstrates the effectiveness of this approach for realistic radar and coherent receiver applications. In conclusion, two-tone testing shows no impact of the DM technique on ADC linearity.

47 OTHER INSTRUMENTATION↗

Experimentally Observed Electrical Durability of 4H-SiC JFET ICs Operating from 500 C to 700 C

Prolonged 500 degrees Celsius to 700 degrees Celsius electrical testing data from 4H-SiC junction field effect transistor (JFET) integrated circuits (ICs) are combined with post-testing microscopic studies in order to gain more comprehensive understanding of the durability limits of the present version of NASA Glenn's extreme temperature microelectronics technology. The results of this study support the hypothesis that T ≥ 500 degrees Celsius durability-limiting IC failure initiates with thermal-stress-related crack formation where dielectric passivation layers overcoat micron-scale vertical features including patterned metal traces.

high temperature↗

Correlation of the ionisation response at selected points of IC sensitive regions with SEE sensitivity parameters under pulsed laser irradiation

The statistics of the ionisation response amplitude measured at selected points and their surroundings within sensitive regions of integrated circuits (ICs) under focused femtosecond laser irradiation is obtained for samples chosen from large batches of two types of ICs. A correlation between these data and the results of full-chip scanning is found for each type. The criteria for express validation of IC single-event effect (SEE) hardness based on ionisation response measurements at selected points are discussed. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Gbps Fiber-Optic Wavefront Sensing Coherent Optical Receiver

We report recent progress on technology developments at the NASA Glenn Research Center using photonic lanterns for coherent optical communications applications. In particular, the development of a spatial mode-diversity optical receiver using a photonic lantern combined with a photonic integrated circuit (PIC). The PIC is designed for compatibility with the NASA Laser Communication Relay Demonstration’s (LCRD) differential phase-shift keying signaling format. We report on the PIC design and future characterization and packaging efforts. Additionally, we report on the development of a 19-channel photonic lantern and provide updates on efforts to use the photonic lantern as a wavefront sensing device. The photonic lantern insertion loss, and spatial-mode transfer characteristics are detailed, as well as the development of a predictive framework in which the intensities in the 19 single-mode output channels are used to reconstruct the wavefront of the light entering the multi-moded input side of the lantern. Finally, we discuss concepts for potential future systems using photonic lanterns and PICs that combine both wavefront sensing and coherent communications onto a single integrated platform.

Optical Communications↗

Growth and characterization of high-density mats of single-walled carbon nanotubes for interconnects

We grow high-density, aligned single wall carbon nanotube mats for use as interconnects in integrated circuits by remote plasma chemical vapor deposition from a Fe-Al{sub 2}O{sub 3} thin film catalyst. We carry out extensive Raman characterization of the resulting mats, and find that this catalyst system gives rise to a broad range of nanotube diameters, with no preferential selectivity of semiconducting tubes, but with at least 1/3 of metallic tubes.

36 MATERIALS SCIENCE↗

Electronics System for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing eighteen position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper gives an overview of the electronics system we have designed for this instrument. We use specialized application-specific integrated circuits to preprocess the outputs of each CdZnTe crystal. A low-power microprocessor running Windows CE drives the user interface and implements the isotope identification and directionality computations. Finally, we use a field-programmable gate array to perform the computationally intensive imaging tasks in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable voltage source for Penning trap experiments

A voltage reference has been developed to bias ring electrodes of two Penning traps between -90 and 0 V. For output voltages near -90 V, the Allan deviation of the system's voltage instability is less than 1 part in 10{sup 8} over all time scales shorter than 10{sup 4} s. For averaging times longer than several seconds, the system's stability is determined almost completely by the noise, drift, and aging of the zener diodes in the array of voltage reference integrated circuits. For shorter averaging times, active filters built into the new system significantly reduce the intrinsic noise of the zener diodes. The system makes it possible to continuously adjust the ring voltages for frequency locking the axial motion in the two Penning traps. By keeping electrical noise highly correlated between the two traps, measurement uncertainty should be reduced for precision experiments such as Penning trap mass spectrometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thickness measurement system for transparent plates using dual digital versatile disc (DVD) pickups

A low-cost high-precision thickness measurement system for transparent plates that uses dual digital versatile disc (DVD) pickups is proposed. The two DVD pickups are used as the transmitter and the receiver in the measurement system, respectively. One of the DVD pickups emits a laser to the other DVD pickup (receiver) and projects on the photodiode integrated circuit of the receiver. The transparent plate is placed in the optical path to change the focused point that will affect the focusing error signal (FES) of the receiver. Using the FES, a mathematical model for thickness measurement based on the geometric optical method is developed. The experimental results show that the accuracy is 1.5 {mu}m, and the uncertainty is estimated to be {+-}1.37 {mu}m for the measured thickness of 150{mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE SNS VACUUM CONTROL SYSTEM UPGRADE FOR THE SUPERCONDUCTING LINAC

The superconducting linac of the Spallation Neutron Source (SNS) has 23 cryomodules whose vacuum system is monitored and controlled by custom built hardware. The original control hardware was provided by Thomas Jefferson National Accelerator Facility (JLab) and contained a variety of custom boards utilizing integrated circuits to perform logic. The need for control logic changes, a desire to increase maintainability, and a desire to increase flexibility to adapt for the future has led to a Programmable Logic Controller (PLC) based upgrade. This paper provides an overview of the commercial off-the-shelf (COTS) hardware being used in the superconducting vacuum control system. Details of the design and challenges to convert a control system during small windows of maintenance periods without disrupting beam operation will be covered in this paper.

43 PARTICLE ACCELERATORS↗