Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Sequential Deposition of Organic Films with Eco‐Compatible Solvents Improves Performance and Enables Over 12%‐Efficiency Nonfullerene Solar Cells

Abstract Casting of a donor:acceptor bulk‐heterojunction structure from a single ink has been the predominant fabrication method of organic photovoltaics (OPVs). Despite the success of such bulk heterojunctions, the task ofcontrolling the microstructure in a single casting process has been arduous and alternative approaches are desired. To achieve OPVs with a desirable microstructure, a facile and eco‐compatible sequential deposition approach is demonstrated for polymer/small‐molecule pairs. Using a nominally amorphous polymer as the model material, the profound influence of casting solvent is shown on the molecular ordering of the film, and thus the device performance and mesoscale morphology of sequentially deposited OPVs can be tuned. Static and in situ X‐ray scattering indicate that applying (R)‐(+)‐limonene is able to greatly promote the molecular order of weakly crystalline polymers and form the largest domain spacing exclusively, which correlates well with the best efficiency of 12.5% in sequentially deposited devices. The sequentially cast device generally outperforms its control device based on traditional single‐ink bulk‐heterojunction structure. More crucially, a simple polymer:solvent interaction parameter χ is positively correlated with domain spacing in these sequentially deposited devices. These findings shed light on innovative approaches to rationally create environmentally friendly and highly efficient electronics.

Ye, Long↗

Electrochemical Stability of Li 10 GeP 2 S 12 and Li 7 La 3 Zr 2 O 12 Solid Electrolytes

The electrochemical stability window of solid electrolyte is overestimated by the conventional experimental method using a Li/electrolyte/inert metal semiblocking electrode because of the limited contact area between solid electrolyte and inert metal. Since the battery is cycled in the overestimated stability window, the decomposition of the solid electrolyte at the interfaces occurs but has been ignored as a cause for high interfacial resistances in previous studies, limiting the performance improvement of the bulk-type solid-state battery despite the decades of research efforts. Thus, there is an urgent need to identify the intrinsic stability window of the solid electrolyte. The thermodynamic electrochemical stability window of solid electrolytes is calculated using first principles computation methods, and an experimental method is developed to measure the intrinsic electrochemical stability window of solid electrolytes using a Li/electrolyte/electrolyte-carbon cell. The most promising solid electrolytes, Li10GeP2S12 and cubic Li-garnet Li7La3Zr2O12, are chosen as the model materials for sulfide and oxide solid electrolytes, respectively. The results provide valuable insights to address the most challenging problems of the interfacial stability and resistance in high-performance solid-state batteries.

25 ENERGY STORAGE↗

An Artificial SEI Enables the Use of A LiNi0.5Mn1.5O4 5 V Cathode with Conventional Electrolytes

LiNi0.5Mn1.5O4 spinel is considered one of the most promising cathodes for advanced lithium ion batteries. However, the operation potential of LiNi0.5Mn1.5O4, ~4.75 V, is beyond the high voltage limit of the state-of-art electrolyte, ~4.3 V. Here, using thin films of LiNi0.5Mn1.5O4 as a model material, we show evidence that an artificial solid electrolyte interphase (SEI) enables the use of this 5 V cathode with conventional carbonate electrolytes. A thin coating of Lipon (lithium phosphorus oxynitride) as an artificial SEI on LiNi0.5Mn1.5O4 could remedy the decomposition of the electrolyte. The thickness of the Lipon artificial SEI is optimized by balancing the protection and additional resistance. The strategy of artificial SEI on cathodes is expected to enable the wide application of other high voltage cathodes for lithium ion batteries.

artificial SEI↗

High‐Capacity Splitting of Mono‐ and Dibranched Hexane Isomers by a Robust Zinc‐Based Metal–Organic Framework

Abstract High‐efficiency separation of C 6 alkanes, particularly the mono‐ and dibranched isomers by using porous solids, is of paramount significance in the petrochemical industry and, remains a daunting challenge. In this work, we report the complete separation of linear/monobranched hexanes from their dibranched isomers through selective size‐exclusion by a microporous MOF, Zn‐tcpt (H 3 tcpt=2,4,6‐tris(4‐carboxyphenoxy)‐1,3,5‐triazine), with a two‐fold interpenetrated structure of hms nets. Importantly, its adsorption capacity and selectivity are notably higher than those of the previously reported adsorbents that can split mono‐ and dibranched alkane isomers. Dynamic breakthrough measurements verify the excellent separation of C 6 alkane isomers by Zn‐tcpt, and the size‐exclusion based separation mechanism has been confirmed by ab initio materials modeling. The high‐efficiency separation of alkane isomers by Zn‐tcpt can be attributed to its optimal pore dimensions as well as high porosity.

Yu, Liang↗

High–Capacity Splitting of Mono– and Dibranched Hexane Isomers by a Robust Zinc–Based Metal–Organic Framework

High-efficiency separation of C 6 alkanes, particularly the mono- and dibranched isomers by using porous solids, is of paramount significance in the petrochemical industry and, remains a daunting challenge. In this work, we report the complete separation of linear/monobranched hexanes from their dibranched isomers through selective size-exclusion by a microporous MOF, Zn-tcpt (H3tcpt=2,4,6-tris(4-carboxyphenoxy)-1,3,5-triazine), with a two-fold interpenetrated structure of hms nets. Importantly, its adsorption capacity and selectivity are notably higher than those of the previously reported adsorbents that can split mono- and dibranched alkane isomers. Dynamic breakthrough measurements verify the excellent separation of C 6 alkane isomers by Zn-tcpt, and the size-exclusion based separation mechanism has been confirmed by ab initio materials modeling. Furthermore, the high-efficiency separation of alkane isomers by Zn-tcpt can be attributed to its optimal pore dimensions as well as high porosity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decreased Neointimal Extracellular Matrix Formation in RAGE-Knockout Mice After Microvascular Denudation

Purpose: To evaluate in vivo the role of RAGE (receptor for advanced glycated end products) in the development of restenosis and neointimal proliferation in RAGE-deficient knockout (KO) mice compared with wild-type (WT) mice in an animal model. Materials and Methods: Sixteen WT and 15 RAGE-deficient mice underwent microvascular denudation of the common femoral artery under general anaesthesia. Contralateral arteries underwent a sham operation and served as controls. Four weeks after the intervention, all animals were killed, and paraformaldehyde-fixed specimens of the femoral artery were analysed with different stains (hematoxylin and eosin and Elastica van Gieson) and several different types of immunostaining (proliferating cell nuclear antigen, {alpha}-actin, collagen, von Willebrand factor, RAGE). Luminal area, area of the neointima, and area of the media were measured in all specimens. In addition, colony-formation assays were performed, and collagen production by WT smooth muscle cells (SMCs) and RAGE-KO SMCs was determined. For statistical analysis, P < 0.05 was considered statistically significant. Results: Four weeks after denudation, WT mice showed a 49.6% loss of luminal area compared with 14.9% loss of luminal area in RAGE-deficient mice (sham = 0% loss) (P < 0.001). The neointima was 18.2 (*1000 {mu}m{sup 2} [n = 15) in the WT group compared with only 8.4 (*1000 {mu}m{sup 2} [n = 16]) in the RAGE-KO group. RAGE-KO SMCs showed significantly decreased proliferation activity and production of extracellular matrix protein. Conclusion: RAGE may be shown to play a considerable role in the formation of neointima leading to restenosis after vascular injury.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models

IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests were performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Accumulation and Effects of Liposomal Doxorubicin in Tissues Treated by Radiofrequency Ablation and Irreversible Electroporation in Liver: In Vivo Experimental Study on Porcine Models

Purpose: To compare the accumulation and effect of liposomal doxorubicin in liver tissue treated by radiofrequency ablation (RFA) and irreversible electroporation (IRE) in in vivo porcine models. Materials and Methods: Sixteen RFA and 16 IRE procedures were performed in healthy liver of two groups of three pigs. Multi-tined RFA parameters included: 100 W, target temperature 105°C for 7 min. 100 IRE pulses were delivered using two monopolar electrodes at 2250 V, 1 Hz, for 100 µsec. For each group, two pigs received 50 mg liposomal doxorubicin (0.5 mg/kg) as a drip infusion during ablation procedure, with one pig serving as control. Samples were harvested from the central and peripheral zones of the ablation at 24 and 72 h. Immunohistochemical analysis to evaluate the degree of cellular stress, DNA damage, and degree of apoptosis was performed. These and the ablation sizes were compared. Doxorubicin concentrations were also analyzed using fluorescence photometry of homogenized tissue. Results: RFA treatment zones created with concomitant administration of doxorubicin at 24 h were significantly larger than controls (2.5 ± 0.3 cm vs. 2.2 ± 0.2 cm; p = 0.04). By contrast, IRE treatment zones were negatively influenced by chemotherapy (2.2 ± 0.4 cm vs. 2.6 ± 0.4 cm; p = 0.05). At 24 h, doxorubicin concentrations in peripheral and central zones of RFA were significantly increased in comparison with untreated parenchyma (0.431 ± 0.078 µg/g and 0.314 ± 0.055 µg/g vs. 0.18 ± 0.012 µg/g; p < 0.05). Doxorubicin concentrations in IRE zones were not significantly different from untreated liver (0.191 ± 0.049 µg/g and 0.210 ± 0.049 µg/g vs. 0.18 ± 0.012 µg/g). Conclusions: Whereas there is an increased accumulation of periprocedural doxorubicin and an associated increase in ablation zone following RFA, a contrary effect is noted with IRE. These discrepant findings suggest that different mechanisms and synergies will need to be considered in order to select optimal adjuvants for different classes of ablation devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Feasibility of Arterial Embolization with Permanent and Absorbable Suture: The FAIR-Embo Concept

Purpose: Arterial embolization has been shown to be effective and safe for the management of bleeding, especially for postpartum and pelvic traumatic bleeding. We propose to evaluate the proof of concept of feasibility and effectiveness of arterial embolization with absorbable and non-absorbable sutures in a porcine model. Materials and Methods: In the acute setting (n = 1), several different arteries (mesenteric, splenic, pharyngeal, kidney) were embolized using non-absorbable sutures (NAS): Mersutures™ braided sutures (polyethylene terephthalate). In the chronic setting (n = 3), only lower pole renal arteries were embolized. On the right side, NAS was used, whereas on the left side embolization was realized with absorbable suture (AS): Vicryl{sup ®} braided suture (polyglactin 910). The chronic group was followed for 3 months. The pigs received contrast-enhanced CT the day before embolization (D-1), after the embolization (D0), at 1 month and 3 months after embolization (M1 and M3); digital subtraction angiography (DSA) was done at D0 and M3 and histological analysis at M3. Results: All vascular targets were effectively embolized without any pre- or postoperative complications. Both DSAs and CTs at M3 showed a 100% recanalization rate for the AS embolization and a partial reversal rate for the NAS embolization. A renal hypotrophy in the embolized region was observed during both the M1 and M3 scans for both sutures (AS and NAS) with a clear hypotrophy for the NAS embolized kidney. Conclusion: Embolization by AS and NAS (FAIR-Embo) is a feasible and effective treatment which opens up the possibility of global use of this inexpensive and widely available embolization agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Expandable Biodegradable Stents Versus Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Urethra

Purpose: To compare the degrees of stent-induced tissue hyperplasia of balloon-expandable, biodegradable stents (BEBSs) with those of self-expandable metallic stents (SEMSs) in a rat urethral model. Materials and Methods: A total of 20 rats were randomized into two groups. The BEBS group (n = 10) received a poly-l-lactic acid (PLLA) biodegradable stent. The SEMS group (n = 10) received a nitinol bare stent. All rats were killed eight weeks after stent placement. The degree of stent-induced tissue hyperplasia was assessed by comparing the results of retrograde urethrography and histologic examination between the two groups. Results: Stent placement was technically successful in all rats. Two rats in the BEBS group were excluded due to procedure-related death. The mean luminal diameter of stented urethra on urethrograms was not significantly different at 4 and 8 weeks between the two groups. On histologic analysis, the percentage of granulation tissue area (p < 0.001) and the thickness of papillary projection (p < 0.001) were significantly higher in the BEBS group compared with the SEMS group. The inflammatory cell infiltration showed a clear tendency to significance (p = 0.050). There were no statistical differences in the number of epithelial layers and the thickness of submucosal fibrosis between the two groups. Conclusion: Formation of stent-induced tissue hyperplasia was significantly evident in the rat urethra with similar degrees between the BEBS and the SEMS. The BEBS was associated with a thicker papillary projection and larger granulation tissue area resulting from higher inflammation compared with the SEMS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unveiling mechanism of surface-guided platinum nanowire growth

We report surface-guided growth of non-planar nanowires on functional substrates offers the new opportunity to precisely control their diameter, length, density and alignment, which will greatly benefit their direct integration into practical devices for large-scale applications. However, control of noble metal nanowires growth and arrangement remains a great challenge, and the mechanistic understanding is still limited. Herein, we choose Pt as a model material system to study the synthesis conditions required to control the in situ growth of aligned Pt nanowires on flat titanium substrate via a one-step and room-temperature green chemical synthesis process in aqueous solution. Most importantly, it is for the first time discovered that ordered nanoarrays and self-assembled nanoflowers can be directly grown on flat Ti substrate by merely adjusting the reaction times, without use of any soft/hard templates, surfactants and organic solvents. The proposed surface-guided growth mechanisms for nanoarray and nanoflower formation in this study may shed light on understanding of oriented arrangement/assembly of one-dimensional Pt nanowires into desirable morphologies for a variety of practical device applications.

Pt nanoflower↗

Ultrasonic Attenuation Due to Grain Boundary Scattering in Pure Niobium

Experimental confirmation of various grain scattering theories exist but there are still outstanding questions concerning the characterization of microstructure using ultrasound. In this study, high purity niobium serves as a model material devoid of extrinsic scattering centers (e.g., voids, precipitates, second phase particles etc.) A range of microstructures were obtained by annealing in ultrahigh vacuum at different temperatures (600–800°C) after routine cold-rolling and recrystallization heat treatment. Ultrasonic attenuation is measured as a function of a frequency for each sample. For the samples with an intermediate grain size (typically ∼50 μm), attenuation follows a power law dependence on frequency with an exponent of n∼1.6, which is close to the prediction, n=2, of classical Stochastic scattering theory. However, quantitative comparison shows that the observed attenuation is higher than predicted by the classical theory. The Stanke-Kino unified grain scattering theory may provide an explanation for the lower frequency dependence than traditional theories predict, though it still under predicts the magnitude of the attenuation. In any event, the resulting empirical relations provide a useful approach for practical grain size measurement with an acceptable level of uncertainty. The effect of a layered microstructure typical of some sheets/plates is discussed.

36 MATERIALS SCIENCE↗

Effect of Fragile Speckle Patterns on Accuracy of Digital Volume Correlation

Due to challenges in generating high-quality 3D speckle patterns for Digital Volume Correlation (DVC) strain measurements, DVC experiments often utilize the intrinsic texture and contrast of composite microstructures. One common deficiency of these natural speckle patterns is their poor durability under large deformations, which can lead to decorrelation and inaccurate strain measurements. Using syntactic foams as a model material, the effects of speckle pattern degradation on the accuracy of DVC displacement and strain measurements are assessed with both experimentally-acquired and numerically-generated images. It is shown that measurement error can be classified into two regimes as a function of the percentage of markers that have disappeared from the speckle pattern. For minor levels of damage beneath a critical level of damage, displacement and strain error remained near the noise floor of less than 0.05 voxels and 100 με, respectively; above this level, error rapidly increased to unacceptable levels above 0.2 voxels and 10,000 με. This transition occurred after 30%–40% of the speckles disappeared, depending on characteristics of the speckle pattern and its degradation mechanisms. Furthermore, these results suggest that accurate DVC measurements can be obtained in many types of fragile materials despite severe damage to the speckle pattern.

42 ENGINEERING↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

Building Toward the Future in Chemical and Materials Simulation with Accessible and Intelligently Designed Web Applications

Over the last few decades, significant progress has been made in the development and use of electronic structure and other molecular simulation methods. As these methods become more mature and are able to simulate larger and more complex chemical simulations, the need for improvement in scientific visualization, molecular builders, simplified input to simulation methods, and the development of new approaches and languages to describe simulations, along with workflows to carry them out, becomes more apparent. In this chapter, we describe our recent efforts in developing a prototype open-source computational tool called Arrows that combines NWChem, SQL and NoSQL databases, email, web APIs, and web applications in a way that make molecular and materials modeling accessible to all scientists and engineers. At the same time, because of its simplified input, it provides a framework for expert users to carry out large numbers of calculations and run complex workflows.

Achieving high strength and ductility in traditionally brittle soft magnetic intermetallics via additive manufacturing

Intermetallic alloys possess exceptional soft magnetic properties, including high permeability, low coercivity, and high saturation induction, but exhibit poor mechanical properties that make them impractical to bulk process and use at ideal compositions. We used laser-based Additive Manufacturing to process traditionally brittle Fe–Co and Fe–Si alloys in bulk form without macroscopic defects and at near-ideal compositions for electromagnetic applications. The binary Fe–50Co, as a model material, demonstrated simultaneous high strength (600–700 MPa) and high ductility (35%) in tension, corresponding to a ~300% increase in strength and an order-of-magnitude improvement in ductility relative to conventionally processed material. Atomic-scale toughening and strengthening mechanisms, based on engineered multiscale microstructures, are proposed to explain the unusual combination of mechanical properties. Here, this work presents an instance in which metal Additive Manufacturing processes are enabling, rather than limiting, the development of higher-performance alloys.

36 MATERIALS SCIENCE↗

An additive manufacturing design approach to achieving high strength and ductility in traditionally brittle alloys via laser powder bed fusion

Additive Manufacturing (AM) presents unprecedented opportunities to enable design freedom in parts that are unachievable via conventional manufacturing. However, AM-processed components generally lack the necessary performance metrics for widespread commercial adoption. We present a novel AM processing and design approach using removable heat sink artifacts to tailor the mechanical properties of traditionally low strength and low ductility alloys. The design approach is demonstrated with the Fe-50 at.% Co alloy, as a model material of interest for electromagnetic applications. AM-processed components exhibited unprecedented performance, with a 300 % increase in strength and an order-of-magnitude improvement in ductility relative to conventional wrought material. These results are discussed in the context of product performance, production yield, and manufacturing implications toward enabling the design and processing of high-performance, next-generation components, and alloys.

36 MATERIALS SCIENCE↗