Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES - ELASTICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Interaction of a Rectangular Jet with a Flat-Plate Placed Parallel to the Flow

An experimental study is carried out addressing the flowfield and radiated noise from the interaction of a large aspect ratio rectangular jet with a flat plate placed parallel to but away from the direct path of the jet. Sound pressure level spectra exhibit an increase in the noise levels for both the 'reflected' and 'shielded' sides of the plate relative to the free-jet case. Detailed cross-sectional distributions of flowfield properties obtained by hot-wire anemometry are documented for a low subsonic condition. Corresponding mean Mach number distributions obtained by Pitot-probe surveys are presented for high subsonic conditions. In the latter flow regime and for certain relative locations of the plate, a flow resonance accompanied by audible tones is encountered. Under the resonant condition the jet cross-section experiences an 'axis-switching' and flow visualization indicates the presence of an organized 'vortex street'. The trends of the resonant frequency variation with flow parameters exhibit some similarities to, but also marked differences with, corresponding trends of the well-known edgetone phenomenon.

Zaman, K. B. M. Q.↗

Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

Yu, Lingyu↗

Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

radiometry↗

Comparison of Mixing Characteristics for Several Fuel Injectors on an Open Plate and in a Ducted Flowpath Configuration at Hypervelocity Flow Conditions

In order to reduce the cost and complexity associated with fuel injection and mixing experiments for high-speed flows, and to further enable optical access to the test section for nonintrusive diagnostics, the Enhanced Injection and Mixing Project (EIMP) utilizes an open flat plate configuration to characterize inert mixing properties of various fuel injectors for hypervelocity applications. The experiments also utilize reduced total temperature conditions to alleviate the need for hardware cooling. The use of "cold" flows and non-reacting mixtures for mixing experiments is not new, and has been extensively utilized as a screening technique for scramjet fuel injectors. The impact of reduced facility-air total temperature, and the use of inert fuel simulants, such as helium, on the mixing character of the flow has been assessed in previous numerical studies by the authors. Mixing performance was characterized for three different injectors: a strut, a ramp, and a flushwall. The present study focuses on the impact of using an open plate to approximate mixing in the duct. Toward this end, Reynolds-averaged simulations (RAS) were performed for the three fuel injectors in an open plate configuration and in a duct. The mixing parameters of interest, such as mixing efficiency and total pressure recovery, are then computed and compared for the two configurations. In addition to mixing efficiency and total pressure recovery, the combustion efficiency and thrust potential are also computed for the reacting simulations.

Drozda, Tomasz G.↗

The Effect of Electrolyte Composition on Lithium Plating During Low Temperature Charging of Li-Ion Cells

In the present work, a number of additives have been investigated for their effect on the charge characteristics of cells containing low temperature, high ester content electrolytes (1.0 M LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC) + methyl propionate (MP) 20:20:60 vol % + X additive). These experimental three-electrode cells are composed of graphite anodes, LiNiCoAlO2 cathodes, and a lithium metal reference electrode. Cells were first subjected to electrochemical characterization at various temperatures, consisting of performing Electrochemical Impedance Spectroscopy (EIS), linear micropolarization and Tafel polarization measurement to determine the kinetic parameters for both the anodes and cathodes. Following electrochemical characterization, the cells were subjected to charging at decreasing temperatures using C/5 rates to 4.10V, with a constant potential C/50 current taper. Analysis of the C/20 discharge following the charge at low temperature revealed either the presence or absence of a high voltage plateau during the initial stages of the discharge. This plateau has been linked to the presence of lithium metal on the anode previously and was used as a measure for the extent of lithium plating in the cell. Differential analysis (dV/dQ) was applied as well to more clearly visualize the position of the high voltage plateau and use the peak position (x-axis) in the dV/dQ plot as a gauge for the amount of plating which took place in the cell on the prior charge. Most additives investigated increased the resistance of the anode and decreased the resistance of the cathode, thereby leading to an overall increase in plating observed at low temperature. One additive, LiFSI, was found to be beneficial during low temperature charging, however studies of electrode kinetics from the cell containing LiFSI did not reveal significant improvements compared to the baseline.

Jones, John-Paul↗

The Intermediate Wake of a Thick Flat Plate with a Circular Trailing Edge

The intermediate wake region of a thick flat plate with a circular trailing edge (TE) is investigated with a direct numerical simulation (DNS). The upper and lower separating boundary layers are both turbulent and are statistically identical; the resulting wake is symmetric in the mean. Earlier research dealt with the near/very-near wake of the same plate (x/D < 13.0, x is the streamwise distance from the center of the circular TE and D is the plate-thickness/TE-diameter). In the present investigation the emphasis is on the evolution of shed-vortex structure and turbulence intensity distributions with increasing x; the focus is on the region 20.0 < x/D < 40.0. Profile similarity in wake velocity statistics is explored.

Rai, Man Mohan↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data was obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (on the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report. The rest of the data will be published in a future report, Part II, along with planned CFD predictions of the complex cooling film flow. The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Nozzle↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

1- by 1-Foot Supersonic Wind Tunnel Sidewall Flowfield Compression Plate Study

A method for locally increasing the dynamic pressure in the test section of a supersonic wind tunnel is investigated from a theoretical, computational and experimental perspective, culminating in a reduced-scale, proof-of-concept test at Mach 3.44. Symmetric, variable-angle compression plates along the test section sidewalls generate oblique shockwaves to elevate the test section dynamic pressure (q). The experimental effort utilizes boundary-layer pitot rakes to sample the incoming flow near the floor, pitot and static rakes to measure the high-q core flow and numerous surface taps to map out the static pressure distribution along the floor, ceiling and sidewalls. A reliable and robust starting procedure is developed to establish supersonic flow in the test section and behind the compression plates. A characterization of the incoming floor boundary layer reveals previously documented features (such as a bulge toward the centerline) and an unexpected (and as-yet-unexplained) thickening of the boundary layer with increasing Reynolds number around total pressures of 40–60 psia. The high-q core flow is characterized for eight compression plate angles (4.0–8.0°), eight tunnel total pressures (20–139 psia) and three axial stations (24.95–27.35 inches). The peak dynamic pressure rise exceeds expectations. At conditions relevant to full-scale testing (6.0° and 139 psia), the dynamic pressure increases by a factor of 1.73, the Mach number becomes 2.85 and the total pressure drops imperceptibly. Basic distortion metrics show transverse non-uniformity of less than 5 %. Limited spatial resolution in the static rake measurements warrants additional, higher fidelity testing or computational analysis. Surface-mounted, fast-response instrumentation suggests minimal unsteadiness in the flow, less than a few percent of the mean (comparable to the sensor accuracy).

Wind tunnel testing, test techniques/methods, dyna↗

Multiphysics Computational Analysis of a Perforated Plate Cooling Flow

A multiphysics analysis of a film cooling flow was conducted using a computational fluid dynamics (CFD) solver in conjunction with a conjugate heat transfer (CHT) solver. The film cooling problem consisted of a square nozzle producing a heated subsonic jet over a perforated plate with three sections of 45 cooling holes each. Results from the multiphysics analysis were compared to a CFD-only approach and experimental results. Reynolds-averaged Navier-Stokes (RANS) computations were employed first, with and without the CHT solver. The multiphysics approach provided much closer agreement with experimentally measured plate temperatures than the CFD-only approach. Comparisons of computed velocities and temperatures were also made with experimental data. Hybrid RANS-large eddy simulation calculations employing the Delayed Detached Eddy Simulation (DDES) approach were also conducted within the multiphysics framework. The DDES approach was unable to resolve turbulent structures in the near wall regions. Hence, the RANS part of the DDES model was used in near wall regions, and produced surface temperatures along with velocity and temperature profiles close to the wall that were very similar to the RANS results. The DDES approach did resolve structures in the outer portion of the boundary layer especially near the end of the plate where the boundary layer was thicker. The key result was the improved surface temperatures produced by the multiphysics approach employing CHT over the fluid-only approach.

Computational Fluid Dynamics↗

Computational Study of Low-Speed Boundary-Layer Laminar-Turbulent Transition over a 30º Swept Plate in a Channel

Reliable boundary-layer laminar-turbulent transition predictions are critical for the design of aircraft that use natural or controlled laminar flow to achieve low drag and better fuel efficiency. During cruise flight through low turbulence, the three-dimensional boundary layer over swept surfaces can transition prematurely due to stationary crossflow instabilities induced by surface roughness. Parabolized stability equations analyses have been successfully used to explain the different phases of the transition process under well controlled perturbations such as steps or discrete roughness elements. However, methodologies are still lacking to model the boundary layer receptivity to distributed random roughness, and the following non-linear instability stages leading to transition. For engineering applications, several semi-empirical methods based on linear amplification factors or local helicity have found growing adoption, but their reliability is limited by their level of simplification and the sparsity of data they are based on. To address this gap, a new study of the effect of distributed random surface roughness on crossflow transition was started, using a 30◦ swept plate as a test vehicle. The plate, which is mounted in the 2 Foot × 3 Foot Low-Speed Boundary-Layer Channel at the NASA Langley Research Center, has been tested with micro-scale roughness of varied geometry near the leading edge. In order to analyze the flow in the test section and prepare Direct Numerical Simulations with resolved roughness, Reynolds-Averaged Navier-Stokes (RANS) simulations of the flow over the plate installed in the wind tunnel test section were performed using the Langtry-Menter transition model with stationary crossflow extension. This paper presents the results of these simulations, with comparison to the experiment.

ARMD↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

Short-Transverse Tensile Fracture Behavior of Thick AA2219 Plate - Effects of Theta (Al2Cu) Particle Size and Distribution

An investigation was conducted to obtain a better understanding on the microstructural characteristics of 5-inch-thick AA2219-T87 plate material and the mechanism that led to the unexpected low ductility in the short-transverse (ST) orientation. Materials characterization techniques were utilized to observe the microstructure of fractured tensile specimens and remnant plate material. The mechanism and cause of low ST ductility in the thick plate material is presented and discussed in this report.

Short-Transverse Orientation↗

Shutdown-induced tensile stress in monolithic miniplates as a possible cause of plate pillowing at very high burnup

Post-irradiation examination of Reduced Enrichment for Research and Test Reactors (RERTR)-12 miniplates showed that in-reactor pillowing occurred in at least 4 plates, rendering performance of these plates unacceptable. To address in-reactor failures, efforts are underway to define the mechanisms responsible for in-reactor pillowing, and to suggest improvements to the fuel plate design and operational conditions. To achieve these objectives, the mechanical response of monolithic fuel to fission and thermally-induced stresses was modeled using a commercial finite element analysis code. Calculations of stresses and deformations in monolithic miniplates during irradiation and after the shutdown revealed that the tensile stress generated in the fuel increased from 2 MPa to 100 MPa at shutdown. The increase in tensile stress at shutdown possibly explains in-reactor pillowing of several RERTR-12 miniplates irradiated to the peak local burnup of up to 1.11x1022 fissions/cm3 . This paper presents the modeling approach and calculation results, and compares results with post-irradiation examinations and mechanical testing of irradiated fuel. The implications for the safe use of the monolithic fuel in research reactors are discussed, including the influence of fuel burnup and power on the magnitude of the shutdown-induced tensile stress.

rertr↗

Testing Single Phase IGBT H-Bridge Switch Plates for the High Voltage Converter Modulator at the Spallation Neutron Source

Three IGBT H-bridge switching networks are used in each High Voltage Converter Modulator (HVCM) system at the Spallation Neutron Source (SNS) to generate drive currents to three boost transformer primaries switching between positive and negative bus voltages at 20 kHz. Every switch plate assembly is tested before installing it into an operational HVCM. A Single Phase Test Stand has been built for this purpose, and it is used for adjustment, measurement and testing of different configurations of switch plates. This paper will present a description of the Test Stand configuration and discuss the results of testing switch plates with two different types of IGBT gate drivers currently in use on the HVCM systems. Comparison of timing characteristics of the original and new drivers and the resulting performance reinforces the necessity to replace the original H-bridge network drivers with the upgraded units.

Gate Driver↗

Effusion plate using additive manufacturing methods

Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

33 ADVANCED PROPULSION SYSTEMS↗

Systems and methods for forming microchannel plate (MCP) photodetector assemblies

A MCP photodetector assembly includes an anode plate including a plurality of electrical traces positioned thereon, a plurality of MCPs and a plurality of grid spacers. The MCPs are positioned between the grid spacers. The grid spacers have a grid spacer shape defining at least one aperture. A plurality of shims are positioned between the grid spacers and the MCPs so as to form a stack positioned on the anode plate. Each of the plurality of shims have a shim shape which is the same as the grid spacer shape such that each of the plurality of shims and each of the plurality of grid spacers overlap so as to define at least one MCP aperture. At least a portion of the plurality of MCPs are positioned within the MCP aperture. The shims are structured to electrically couple the MCPs to the anode plate.

47 OTHER INSTRUMENTATION↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗