Search NASA⌕ Search

SEARCH · Search NASA

Results for “VELOCITY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Flat plate models are often used in wind tunnel testing to make measurements of the boundary layer, but preclude the use of conventional focused laser differential interferometry (FLDI) measurements, particularly for measurements at the surface of the model. By instead focusing light in only one direction using cylindrical optics, as opposed to two directions using only spherical optics, FLDI measurements can be made without truncating the beam at the model edges. Measurements at discrete points along a line can also be acquired, effectively acting as many individual FLDI instruments in a single measurement. Here, a two-line FLDI system has been constructed that allows for the measurement lines to be easily oriented at any azimuthal angle about the optical axis since the optics are housed in rotation mounts. Velocity measurements at points along a line or between two lines are also possible, since the beams are split similar to the two-point FLDI instrument. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation, along with high-speed schlieren measurements for comparison. The system was then installed at the NASA Langley 20-Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel freestream.

Joshua M Weisberger↗

Particle Image Velocimetry Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle

Liquid metal fast reactor fuel assemblies using sodium as a coolant typically utilize a tightly packed triangular lattice of fuel pins enclosed in a hexagonal duct. The fuel pins are typically wrapped with a helical wire spacer. The primary function of the wire spacers is to maintain a gap between neighboring fuel pins. They also mitigate vortex-induced vibration and enhance sub-channel mixing to increase convective heat transfer. Many experiments have been performed to study thermal-hydraulic characteristics, primarily pressure drops, of the wire-wrapped fuel bundles. Novendstern developed a semi-empirical model to predict pressure losses in a hexagonal array of wire-wrapped pins in the turbulent flow regime. Rehme proposed pressure drop correlations for a wide range of geometrical parameters, such as pitch-to-diameter ratio P/D from 1.125 to 1.417, lead-to-wire diameter ratio H / dm from 6 to 45, and number of pins n from 7 to 61. Cheng and Todreas introduced their hydrodynamic models for subchannel friction factors and mixing parameters in a 37-pin fuel bundle, which covered the laminar, transition and turbulent flow regimes. Computational fluid dynamics (CFD) offers an opportunity to validate the above correlations and investigate the flow characteristics in the subchannels. Several numerical studies of the wire-wrapped fuel bundles have been performed and most of them are Reynolds-Averaged Navier-Stokes (RANS) based simulations with various turbulence models. Ahmad and Kim performed RANS simulations of 7- and 19-pin bundles using the k-omega SST turbulent model, while Gajapathy et al. performed RANS simulations on 7-pin bundles using the k-epsilons model. Recently, Fischer et al. carried out large-eddy simulation (LES) calculations on wire-wrapped fuel bundles to obtain higher-resolution numerical solutions of subchannel behavior. The geometrical complexity of the hexagonal wire-wrapped fuel bundle has limited experimental activities to pressure drop measurements. A database of pressure drops and flow-field measurements in a 61-pin wire-wrapped hexagonal fuel bundle is not available to benchmark the existing correlations and validate the CFD calculations. Texas A and M University is conducting isothermal flow experiments in a wire-wrapped 61-pin hexagonal fuel bundle to support the research on advanced nuclear fuel development sponsored by the Department of Energy (DOE). The purpose of these tests is to perform high spatial and temporal resolution measurements of the flow and pressure measurements at different locations in the fuel bundle. The experimental facility employs matched-index-of-refraction (MIR) techniques and laser diagnostic velocity measurement techniques such as particle image velocimetry (PIV) and laser Doppler velocimetry (LDV). The result of this experimental activity will be an experimental database of pressure and flow-field measurements that will be suitable for validating CFD computer codes. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rotation Measurement

In aircraft turbine engine research, certain investigations require extremely precise measurement of the position of a rotating part, such as the rotor, a disc-like part of the engine's compressor which revolves around a shaft at extremely high speeds. For example, in studies of airflow velocity within a compressor, researchers need to know-for data correlation the instantaneous position of a given spot on the rotor each time a velocity measurement is made. Earlier methods of measuring rotor shaft angle required a physical connection to the shaft, which limited the velocity of the rotating object.

Source record↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow-Field Measurements in a Wing-Fuselage Junction Using an Embedded Particle Image Velocimetry System

A novel, embedded, 2D Particle Image Velocimetry system has been developed and implemented to obtain off-body velocity measurements in the junction of an 8% wing-body configuration in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Although the initial purpose for implementing the system during this test was to evaluate system performance and identify potential risks, the system worked remarkably well and a considerable amount of data were obtained in the wing-fuselage junction near the trailing edge at a Reynolds Number of 2.4 Million and angle of attack of 5 degrees. In addition to providing notable efficiencies with regard to image acquisition and test operations, the PIV system proved to be quite capable of capturing unique details of the flow separation to complement the extensive suite of measurement techniques applied during the test. Instantaneous PIV vector fields reveal that the flow separation is not stationary but rather highly dynamic. Mean flow statistics calculated from the PIV measurements highlight where reverse flow and Reynolds stresses are concentrated in the separated region and agree well with results from the embedded Laser Doppler Velocimeter system and Computational Fluid Dynamics. The comparisons and additional insight gained during this effort will help guide system improvements for follow-on tests.

Jenkins, Luther N.↗

Early hydration and setting of oil well cement

A broad experimental study has been performed to characterize the early hydration and setting of cement pastes prepared with Class H oil well cement at water-to-cement ratios (w/c) from 0.25 to 0.40, cured at temperatures from 10 to 60 {sup o}C, and mixed with chemical additives. Chemical shrinkage during hydration was measured by a newly developed system, degree of hydration was determined by thermogravimetric analysis, and setting time was tested by Vicat and ultrasonic velocity measurements. A Boundary Nucleation and Growth model provides a good fit to the chemical shrinkage data. Temperature increase and accelerator additions expedite the rate of cement hydration by causing more rapid nucleation of hydration products, leading to earlier setting; conversely, retarder and viscosity modifying agents delay cement nucleation, causing later setting times. Lower w/c paste needs less hydration product to form a percolating solid network (i.e., to reach the initial setting point). However, for the systems evaluated, at a given w/c, the degree of hydration at setting is a constant, regardless of the effects of ambient temperature or the presence of additives.

36 MATERIALS SCIENCE↗

Viscosity of confined two-dimensional Yukawa liquids: A nonequilibrium method

We present a nonequilibrium method that allows one to determine the viscosity of two-dimensional dust clusters in an isotropic confinement. By applying a tangential external force to the outer parts of the cluster (e.g., with lasers), a sheared velocity profile is created. The decay of the angular velocity towards the center of the confinement potential is determined by a balance between internal (viscosity) and external friction (neutral gas damping). The viscosity can then be calculated from a fit of the measured velocity profile to a solution of the Navier-Stokes equation. Langevin dynamics simulations are used to demonstrate the feasibility of the method. We find good agreement of the measured viscosity with previous results for macroscopic Yukawa plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long, accurate time series measurements of radial velocities of solar-type stars

We have been measuring changes in the radial velocities (RV's) of solar-type stars to search for gravitational perturbations by planets. We transmit violet starlight through a Fabry-Perot etalon interferometer and sense changes in Doppler shift from changes in the fluxes of light on the slopes of stellar absorption lines. Our data now span 6 years. Our observations of the Sun showed earlier that both our technique and the profiles of solar photospheric violet absorption lines can be stable enough to reveal planetary perturbations. We now carry this validation to the spectra of other near-solar-type to reveal planetary perturbations. We now carry this validation to the spectra of other near-solar-type stars. Annual averages of our RV's of sigma Draconis and beta Virginis are stable to plus or minus 6 m/s. The slope of our five-year series of RV's of xi Bootis A is consistent with the star's well-determined visual astrometric orbit about xi Bootis B. The Fabry-Perot technique of Doppler shift measurement is fully capable of detecting perturbations due to planets with masses and orbits similar to those of Jupiter

Mcmillan, R. S.↗

An experimental and kinetic modeling study of cyclopentane and dimethyl ether blends

Cyclopentane is a suitable naphthene, or cycloalkane, in a palette for multi-component gasoline surrogate fuels due to its presence in market fuels and its relevance to alkyl substituted cyclopentanes also present. However, the previous oxidation studies of cyclopentane have primarily focused on neat mixtures. Blending cyclopentane with dimethyl ether in this work therefore serves to inform our understanding of, and improve predictive models for, multi-component mixtures. Here, the auto-ignition of cyclopentane/dimethyl ether blends was studied in a high-pressure shock tube and in a rapid compression machine. A wide range of temperatures (650 – 1350 K) and elevated pressures of 20 and 40 bar were studied at equivalence ratios of 0.5, 1.0 and 2.0 in air for two blending ratios (30/70 and 70/30 mole% cyclopentane/di-methyl ether mixtures). A detailed kinetic model for cyclopentane was revised to capture the measured ignition delay times and apparent heat release rates in this study. Literature ignition delay time, jet-stirred reactor, and laminar burning velocity measurements of neat cyclopentane were used as additional validation. Improvements to the kinetic model were based on recent literature studies related to sub-models including cyclopentene and cyclopentadiene which allowed the removal of previous local rate-constant optimizations. Low temperature reactivity of cyclopentane was found to be controlled by the branching ratio between concerted elimination of HO͘ 2 and the strained formation of Q&#775OOH radicals in agreement with previous studies. In this study, the low branching ratio of Q&#775OOH formation increases the influence of a competing consumption pathway for cyclopentyl-peroxy (CPTO͘ 2 J) radicals. The sensitivity of the simulated ignition delay times to the formation of cyclopentyl hydroperoxide (CPTO 2 H), from CPTO͘ 2 J and HO͘ 2 , is discussed. The current model is used to analyze the influence of dimethyl ether on the reactivity of cyclopentane in the context of previous literature studies of dimethyl ether binary blends with ethanol and toluene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Turbulence from Moored Acoustic Doppler Velocimeters. A Manual to Quantifying Inflow at Tidal Energy Sites

This work details a methodology for measuring hub height inflow turbulence using moored acoustic Doppler velocimiters (ADVs). This approach is motivated by the shortcomings of alternatives. For example, remote velocity measurements (i.e., from acoustic Doppler profilers) lack sufficient precision for device simulation, and rigid tower-mounted measurements are very expensive and technically challenging in the tidal environment. Moorings offer a low-cost, site-adaptable and robust deployment platform, and ADVs provide the necessary precision to accurately quantify turbulence.

16 TIDAL AND WAVE POWER↗

Optical measurement systems

Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

Lesco, Daniel J.↗

Navigation Doppler Lidar Performance at High Speed and Long Range

NASA is developing a Navigational Doppler LiDAR (NDL) for use in missions involving robotic and human landing scenarios on solar system bodies. The NDL provides unprecedented accuracy in position and velocity measurement for the guidance, navigation and control (GNC) subsystem of a spacecraft. NDL performance has been characterized over different phases of its development through ground tests, helicopter flight tests, and onboard rocket-powered test vehicles, however, none of these tests provided measurements over its full performance envelope. For this reason, a high speed rocket sled test was recently conducted to resolve both range and velocity up to the maximum limits of the NDL. This test campaign was performed at the Supersonic Naval Ordnance Research Tracks (SNORT) facility, Naval Air Weapons Station China Lake, as part of the Safe & Precise Landing and Integrated Capabilities Evolution (SPLICE) project.

Aram Gragossian↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

CAN A LONG NANOFLARE STORM EXPLAIN THE OBSERVED EMISSION MEASURE DISTRIBUTIONS IN ACTIVE REGION CORES?

All theories that attempt to explain the heating of the high-temperature plasma observed in the solar corona are based on short bursts of energy. The intensities and velocities measured in the cores of quiescent active regions, however, can be steady over many hours of observation. One heating scenario that has been proposed to reconcile such observations with impulsive heating models is the 'long nanoflare storm', where short-duration heating events occur infrequently on many sub-resolution strands; the emission of the strands is then averaged together to explain the observed steady structures. In this Letter, we examine the emission measure distribution predicted for such a long nanoflare storm by modeling an arcade of strands in an active region core. Comparisons of the computed emission measure distributions with recent observations indicate that the long nanoflare storm scenario implies greater than five times more 1 MK emission than is actually observed for all plausible combinations of loop lengths, heating rates, and abundances. We conjecture that if the plasma had 'super coronal' abundances, the model may be able to match the observations at low temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-lapse VSP integration and calibration of subsurface stress field utilizing machine learning approaches: A case study of the morrow B formation, FWU

This study aims to develop a methodology for calibrating subsurface stress changes through time-lapse vertical seismic profiling (VSP) integration. The selected study site is a region around the injector well located within Farnsworth field unit (FWU), where there is an ongoing CO 2 -enhanced oil recovery (EOR) operation. In our study, a site-specific rock physics model was created from extensive geological, geophysical, and geomechanical characterization through 3D seismic data, well logs, and core assessed as part of the 1D MEM conducted on the characterization well within the study area. Here, the Biot-Gassmann workflow was utilized to combine the rock physics and reservoir simulation outputs to determine the seismic velocity change due to fluid substitution. Modeled seismic velocities attributed to mean effective stress were determined from the geomechanical simulation outputs, and the stress-velocity relationship developed from ultrasonic seismic velocity measurements. A machine learning-assisted workflow comprised of an artificial neural network and a particle swarm optimizer (PSO) was utilized to minimize a penalty function created between the modeled seismic velocities and the observed time-lapse VSP dataset. The successful execution of this workflow has affirmed the suitability of acoustic time-lapse measurements for 4D-VSP geomechanical stress calibration pending measurable stress sensitivities within the anticipated effective stress changes and the availability of suitable and reliable datasets for petroelastic modeling. © 2023 Society of Chemical Industry and John Wiley & Sons, Ltd.

58 GEOSCIENCES↗