Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Spinning Reserve from Responsive Load

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparation and characterization of reactive blends of poly(lactic acid), poly(ethylene-co-vinyl alcohol), and poly(ethylene-co-glycidyl methacrylate)

The ternary blends of poly(lactic acid) (PLA), poly(ethylene-co-vinyl alcohol) (EVOH), and poly(ethylene-co-glycidyl methacrylate) (EGMA) were prepared. The role of EGMA as a compatibilizer was evaluated. The weight ratio of PLA:EVOH was 80:20 and the EGMA loadings were varied from 5-20 phr. The blends were characterized as follows: thermal properties by differential scanning calorimetry, morphology by scanning electron microscopy, and mechanical properties by pendulum impact tester, and universal testing machine. The glass transition temperature of PLA blends did not change much when compared with that of PLA. The blends of PLA/EGMA and EVOH/EGMA showed EGMA dispersed droplets where the latter led to poor impact properties. However, the tensile elongation at break and tensile toughness substantially increased upon addition of EGMA to blends of PLA and EVOH. It was noted in tensile test samples that both PLA and EVOH domains fibrillated significantly to produce toughness.

36 MATERIALS SCIENCE↗

Efficiency of Micro-fine Cement Grouting in Liquefiable Sand

In the presence of strong ground motion, liquefaction hazards are likely to occur in saturated cohesion-less soils. The risk of liquefaction and subsequent deformation can be reduced by various ground improvement methods including the cement grouting technique. The grouting method was proposed for non-disruptive mitigation of liquefaction risk at developed sites susceptible to liquefaction. In this research, a large-scale experiment was developed for assessment of micro-fine cement grouting effect on strength behavior and liquefaction potential of loose sand. Loose sand samples treated with micro-fine grout in multidirectional experimental model, were tested under cyclic and monotonic triaxial loading to investigate the influence of micro-fine grout on the deformation properties and pore pressure response. The behavior of pure sand was compared with the behavior of sand grouted with a micro-fine cement grout. The test results were shown that cement grouting with low concentrations significantly decreased the liquefaction potential of loose sand and related ground deformation.

58 GEOSCIENCES↗

Cooperation Reliability Testing of the Clipper Windpower Liberty 2.5 MW Turbine: Cooperative Research and Development Final Report

Clipper Windpower (CWP) has developed the Liberty 2.5 MW wind turbine. The development, manufacturing, and certification process depends heavily on being able to validate the full-scale system design and performance under load in both an accredited structural test facility and through accredited field testing. CWP requested that DOE/ NREL upgrade blade test capabilities to perform a scope of workincluding structural testing of the C-96 blade used on the CWP Liberty turbine. This funds-in CRADA was developed to upgrade NREL blade test capability, while enabling certification testing of the C-96 blade through the facility and equipment upgrades. NREL shared resource funds were used to develop hardware necessary to structurally attach a large wind turbine to the test stand at the NWTC.Participant funds-in monies were used for developing the test program.

17 WIND ENERGY↗

In-situ Creep Testing Capability Development for Advanced Test Reactor

Creep is the slow, time-dependent strain that occurs in a material under a constant strees (or load) at high temperature. High temperature is a relative term, dependent on the materials being evaluated. A typical creep curve is shown in Figure 1-1. In a creep test, a constant load is applied to a tensile specimen maintained at a constant temperature. Strain is then measured over a period of time. The slope of the curve, identified in the figure below, is the strain rate of the test during Stage II or the creep rate of the material. Primary creep, Stage I, is a period of decreasing creep rate due to work hardening of the material. Primary creep is a period of primarily transient creep. During this period, deformation takes place and the resistance to creep increases until Stage II, Secondary creep. Stage II creep is a period with a roughly constant creep rate. Stage II is referred to as steady-state creep because a balance is achieved between the work hardening and annealing (thermal softening) processes. Tertiary creep, Stage III, occurs when there is a reduction in cross sectional area due to necking or effective reduction in area due to internal void formation; that is, the creep rate increases due to necking of the specimen and the associated increase in local stress.

99 GENERAL AND MISCELLANEOUS↗

CoolCab: Reducing Thermal Loads in Long-Haul Trucks (Fact Sheet)

This fact sheet describes how the National Renewable Energy Laboratory's CoolCab project tested and modeled the effects of several thermal-load reduction strategies applied to long-haul truck cabs. NREL partnered with two major truck manufacturers to evaluate three long-haul trucks at NREL's outdoor test facility in Golden, Colorado.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pelletization with Spark Plasma Sintering and Characterization of Metal Iodides: An Assessment of Long-Term Radioiodine Immobilization Options

Four promising iodine “getter” materials (Ag, Cu, Bi, and Sn) for radioiodine capture were assessed in their pure metal-iodide (MI x ) pelletized forms to compare relative chemical durabilities. To study chemical durability, commercial MI x compounds of AgI, BiI 3 , BiOI, CuI, and SnI 4 were converted to dense monolithic pellets using spark plasma sintering. Semidynamic leach testing in the form of modified ASTM C1308 tests was then performed on the pellets in two different forms including unmounted (as-pressed) specimens (i.e., “U”) and epoxy-mounted specimens (i.e., “M”) with polished surfaces. The chemical durability results and sample characterizations showed that three of the five MI x compounds tested (i.e., AgI, CuI, and BiOI) displayed moderate to high leach resistances. Further, the remaining two MI x compounds (i.e., BiI 3 and SnI 4 ), which are both desirable iodine waste forms due to their high iodine loading capacities, readily decomposed during leach testing, indicated by crystallographic changes in the specimens as well as large amounts of iodine detected in the leachate solutions. The instabilities of BiI 3 and SnI 4 raise uncertainties for using the base metals/cations (i.e., Bi 0 /Bi 3+ and Sn 0 /Sn 4+ , respectively) as viable getters for radioiodine capture due to likely poor waste form chemical durabilities after capture and consolidation into waste forms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Distribution Feeders that do not have Voltage Regulators on the number of Charged Electric Vehicles using IEEE 34 Bus Test Feeder

Voltage regulators help maintain an acceptable voltage profile for the system. This paper discusses the effect of installing voltage regulators to the system to fix the voltage drop resulting from the electrical vehicles loading increase when they are being charged. The effect will be studied in the afternoon, when the peak load occurs, using the IEEE 34 bus test feeder. First, only one spot node is used to charge the electric vehicles while a voltage regulator is present. Second, five spot nodes are loaded at the same time to charge the electric vehicles while voltage regulators are installed at each node. After that, the impact of electric vehicles on distribution feeders that do not have voltage regulators will appear.

Allehyani, Ahmed↗

EGR Control for Emisson Reduction Using Fast Response Sensors - Phase 1A

The overall objective of this project was to develop exhaust gas recirculation (EGR) control strategies using fast-response Particulate Matter (PM) sensors and NOx sensors to improve the quality of particulate and gaseous emissions from diesel engines. This project initially comprised three phases: (1) Phase IA - sensor requirements to meet PM sensor specifications, NOx sensor assessment, and initial model development for EGR control; (2) Phase IB - continue development on PM and NOx sensors, integrate the sensor signals into the control simulations, and finalize model development for control strategies; and (3) Phase II - validation testing of the control strategies. Only Phase 1A was funded by DOE and executed by Honeywell. The major objectives of Phase 1A of the project included: (1) Sensor validation and operation of fast-response PM and NOx sensors; (2) Control system modeling of low-pressure EGR controls, development of control strategies, and initial evaluation of these models and strategies for EGR control in diesel engines; (3) Sensor testing to understand applicability of fast-response PM sensors in determining loading rates of the particle trap; and (4) Model validation and sensor testing under steady-state and transient operational conditions of actual engines. In particular, specific objectives included demonstration of: (1) A PM sensor response time constant (T10 - T90) of better than 100 milliseconds (msec); (2) The ability to detect PM at concentrations from 0.2 to 2 Bosch smoke number (BSN) or equivalent; (3) PM sensor accuracy to within 20% BSN over the entire range of operation; and (4) PM sensor repeatability to within 10% over the PM entire sensor range equivalent to a BSN of 0.2 to 2.

33 ADVANCED PROPULSION SYSTEMS↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.

expansion plug test↗

A mobile test facility based on a magnetic cumulative generator to study the stability of the power plants under impact of lightning currents

The report presents the results of the development and field testing of a mobile test facility based on a helical magnetic cumulative generator (MCGTF). The system is designed for full-scale modeling of lightning currents to study the safety of power plants of any type, including nuclear power plants. Advanced technologies of high-energy physics for solving both engineering and applied problems underlie this pilot project. The energy from the magnetic cumulative generator (MCG) is transferred to a high-impedance load with high efficiency of more than 50% using pulse transformer coupling. Modeling of the dynamics of the MEG that operates in a circuit with lumped parameters allows one to apply the law of inductance output during operation of the MCG, thus providing the required front of the current pulse in the load without using any switches. The results of field testing of the MCGTF are presented for both the ground loop and the model load. The ground loop generates a load resistance of 2–4 Ω. In the tests, the ohmic resistance of the model load is 10 Ω. It is shown that the current pulse parameters recorded in the resistive-inductive load are close to the calculated values.

42 ENGINEERING↗

A general nonlinear magnetomechanical model for ferromagnetic materials under a constant weak magnetic field

Weak magnetic nondestructive testing (e.g., metal magnetic memory method) concerns the magnetization variation of ferromagnetic materials due to its applied load and a weak magnetic surrounding them. One key issue on these nondestructive technologies is the magnetomechanical effect for quantitative evaluation of magnetization state from stress–strain condition. A representative phenomenological model has been proposed to explain the magnetomechanical effect by Jiles in 1995. However, the Jiles' model has some deficiencies in quantification, for instance, there is a visible difference between theoretical prediction and experimental measurements on stress–magnetization curve, especially in the compression case. Based on the thermodynamic relations and the approach law of irreversible magnetization, a nonlinear coupled model is proposed to improve the quantitative evaluation of the magnetomechanical effect. Excellent agreement has been achieved between the predictions from the present model and previous experimental results. In comparison with Jiles' model, the prediction accuracy is improved greatly by the present model, particularly for the compression case. A detailed study has also been performed to reveal the effects of initial magnetization status, cyclic loading, and demagnetization factor on the magnetomechanical effect. Our theoretical model reveals that the stable weak magnetic signals of nondestructive testing after multiple cyclic loads are attributed to the first few cycles eliminating most of the irreversible magnetization. Remarkably, the existence of demagnetization field can weaken magnetomechanical effect, therefore, significantly reduces the testing capability. This theoretical model can be adopted to quantitatively analyze magnetic memory signals, and then can be applied in weak magnetic nondestructive testing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Drop Analysis of Department of Energy Standard Canister with Fort Saint Vrain SNF

DOE manages over 300 types of SNF, most of which are located at the INL site. The Idaho Cleanup Project and INL are collaborating on the Road-Ready Capability Demonstration Project, which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF at the INL site for ?road-ready dry storage?. ?Road-ready dry storage? is a SNF management concept where SNF is packaged into dry and sealed canisters, which are then placed in on-site storage in anticipation of later transportation. The forward-looking goal of the Demonstration is establishing the foundation for a large-scale road-ready dry storage program at the INL site. The Demonstration will first package Fort Saint Vrain SNF currently stored at INL into several DOE Standard Canisters. These Standard Canisters will then be loaded into another commercial transportation or storage containment system (e.g., storage cask or transportation package). The Standard Canister is a class of standardized canisters designed for containing the large variety of DOE-managed SNF during interim storage, transportation and/or disposal at a geological repository. One critical aspect of road-ready dry storage is the ability to license the DOE Standard Canisters and its associated transportation package to 10 CFR 71. Depending on the SNF and transportation strategy, the Standard Canisters may have to maintain structural integrity under normal conditions of transport and hypothetical accident scenarios (i.e., drop events). The Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs. However, no analysis has been completed to support the recent Demonstration. This analysis will consider the Ø0.5 m × 5.1 m Standard Canister under drop scenario(s) considered in previous INL tests and analyses, including the 9 m drop at 80 degree off vertical. However, this analysis will consider the more recent Fort Saint Vrain loading configurations proposed for the Demonstration. This analysis will performed using strain-based acceptance criteria established by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, Division 3. It will be compared to previous analyses and form the foundation of further formal calculations that will be used to support licensing efforts of the road-ready dry storage system at INL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distributed fiber optic strain sensing of bending deformation of a well mockup in the laboratory

Well integrity is critical to the safety and success of subsurface energy exploration and management, as leakage of fluids from subsurface reservoirs is often induced by compromised wells. This study investigates bending deformation of a mockup of an oil/gas well that is subjected to loads expected in deviated wells under reservoir compaction and assesses the feasibility of utilizing distributed fiber optic strain sensing to monitor the deformation. Here, a well mockup, which consists of outer and inner steel pipes with a cemented annulus, is tested under three-point bending loading and its strain and curvature development is monitored by Brillouin optical time domain reflectometry/analysis (BOTDR/A) as well as optical frequency domain reflectometry (OFDR). The primary objective of this research is to assess the strain sensing performance of newly fabricated fiber optic cables and to identify key cable characteristics which could improve the quality of distributed strain measurements with BOTDR/A. Results show that the tight-buffered cable is best suited for strain sensing as its maximum errors in the strain measurement were -36% and -24% against conventional sensors at the maximum elastic and plastic bending loads, respectively, whereas those of the non-tight-buffered cable were -45% and -71%, respectively. Similar trends were obtained in the bending curvature measurement. The detailed design of the tight-buffered cable is presented to elucidate key characteristics of such a cable, which will facilitate accurate distributed strain sensing in oil and gas wells.

42 ENGINEERING↗

1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scale-up Testing—Foam as A Remedial Amendment Carrier - 11029

This paper describes results from intermediate-scale, two-dimensional testing of foam injection into sedimentary materials collected from the U.S. Department of Energy (DOE) Hanford Site area. The testing was performed to evaluate the transport of new, more robust, foam generation formulas developed by PNNL on field applicability. The mechanisms of transport , foam stability, delivery pressure, foam migration and the ability of foam to deliver remedial amendments for stabilization of uranium contamination were evaluated. Testing was accomplished in a test bed that is designed to focus on two-dimensional flow, in the form of two, thin rectangular boxes. Each of the boxes holds approximately 135 liters (255 kilograms) of sediment. A total of six sets of tests have been conducted, the last two of which will be described here. During the fifth and sixth tests, foam, generated by means of mechanical blending, was injected into the central screened segment of the left side of each box while air was extracted from multiple screened segments along the right side of each box. During these two tests both of the boxes were loaded to contain a rectangular zones of fine material and a rectangular zone of coarse material . Portions of the sediment were augmented with uranium-rich calcite to produce known concentrations of uranium. The foam generating formulas used in both tests contained sodium phosphate and sodium tripolyphosphate as a remedial amendment. Subsequent to each of the two tests, the test beds were disassembled, and samples of the sediments were taken and analyzed for a number of parameters, depending on the specific test. The data indicated that uranium contamination may be successfully immobilized and that that directional movement of the injected foam can be controlled.

Foam↗