Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Calibrating Historical IR Sensors Using GEO, and AVHRR Infrared Tropical Mean Calibration Models

Long-term, remote-sensing-based climate data records (CDRs) are highly dependent on having consistent, wellcalibrated satellite instrument measurements of the Earth's radiant energy. Therefore, by making historical satellite calibrations consistent with those of today's imagers, the Earth-observing community can benefit from a CDR that spans a minimum of 30 years. Most operational meteorological satellites rely on an onboard blackbody and space looks to provide on-orbit IR calibration, but neither target is traceable to absolute standards. The IR channels can also be affected by ice on the detector window, angle dependency of the scan mirror emissivity, stray-light, and detector-to-detector striping. Being able to quantify and correct such degradations would mean IR data from any satellite imager could contribute to a CDR. Recent efforts have focused on utilizing well-calibrated modern hyper-spectral sensors to intercalibrate concurrent operational IR imagers to a single reference. In order to consistently calibrate both historical and current IR imagers to the same reference, however, another strategy is needed. Large, well-characterized tropical-domain Earth targets have the potential of providing an Earth-view reference accuracy of within 0.5 K. To that effort, NASA Langley is developing an IR tropical mean calibration model in order to calibrate historical Advanced Very High Resolution Radiometer (AVHRR) instruments. Using Meteosat-9 (Met-9) as a reference, empirical models are built based on spatially/temporally binned Met-9 and AVHRR tropical IR brightness temperatures. By demonstrating the stability of the Met-9 tropical models, NOAA-18 AVHRR can be calibrated to Met-9 by matching the AVHRR monthly histogram averages with the Met-9 model. This method is validated with ray-matched AVHRR and Met-9 biasdifference time series. Establishing the validity of this empirical model will allow for the calibration of historical AVHRR sensors to within 0.5 K, and thereby establish a climate-quality IR data record.

Scarino, Benjamin↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Developing a Framework for Reference Cell Standards for PV Resource Applications

Quantifying and predicting electricity production from photovoltaic (PV) systems is based on measured or modeled irradiance data. These solar resource data consist of global horizontal irradiance, global tilted irradiance, direct normal irradiance, and diffuse horizontal irradiance, which are either derived from satellite observations validated against ground-based measurements or directly obtained from ground-based measurements. The ground-based measurements are made using thermopile or photodiode radiometers. For a PV plant, the efficiency of the energy production is verified by comparing measured output with the modeled production, which is computed using either modeled or measured irradiance data. Thus, plant performance assessments typically include the uncertainty of the transposition and, in some cases, decomposition of a given irradiance to convert to the appropriate plane-of-array (POA) irradiance corresponding to the orientation of the PV installation. Additionally, the various types of uncertainty in radiometric measurements or the modeled irradiance and the PV module specifications influence the model results and thereby further increase the uncertainty. An alternative method of assessing the PV system performance has been to use reference cells to measure the "PV resource." When used to calculate PV performance ratios, there are inherent systematic differences between radiometers and reference cells, such as spectral, directional, temperature, time responses, nonstability, and nonlinearity differences. Reference cells tend to mimic the performance and characteristics of a PV module more closely. In this report, a framework is proposed to develop standards that will better quantify and characterize the use of reference cells for PV resource measurements. The measurement from an appropriate reference cell in the POA correlates closely with the plant performance, reduces the number of modeling steps needed to simulate PV performance, and hence reduces the uncertainties of the comparisons. Because technologically matched reference cells and PV modules respond similarly to each wavelength of light that composes the incident solar radiation, the uncertainty associated with the changing spectral distribution of incident radiation during the day and year can be greatly reduced. This will reduce the overall uncertainty in estimated PV performance. The same can be said for the angle-of-incidence effects because the reference cells are deployed in the same POA as the PV module. At that point, the main sources of uncertainty are in modeling the temperature effect differences between the reference cells and the PV module and accounting for the difference between the short-circuit current monitored by the reference cells and max power point current and voltage at which the PV module operates. These sources of uncertainty are also associated with typical irradiance measurements made by pyranometers and pyrheliometers; however, typical irradiance measurements also include uncertainties associated with the spectral mismatch between thermopile or photodiode pyranometers and the PV module, which are minimized with the use of reference cells. To enhance the use of reference cells for resource assessment, we identify the necessary data, characteristics, and calibration methodologies of reference cells and how to standardize the use of these data and methods. Further, as we develop this framework, the classification of reference cells will be essential to provide guidance for selecting PV reference cells appropriate for a specific application. As we address the calibration and sources of uncertainties of reference cells, classification schemes and expected limits of performance with respect to certain parameters become important.

14 SOLAR ENERGY↗

Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources

The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.

Ding, Leibo↗

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah↗

New Techniques to Evaluate the Incendiary Behavior of Insulators

New techniques for evaluating the incendiary behavior of insulators is presented. The onset of incendive brush discharges in air is evaluated using standard spark probe techniques for the case simulating approaches of an electrically grounded sphere to a charged insulator in the presence of a flammable atmosphere. However, this standard technique is unsuitable for the case of brush discharges that may occur during the charging-separation process for two insulator materials. We present experimental techniques to evaluate this hazard in the presence of a flammable atmosphere which is ideally suited to measure the incendiary nature of micro-discharges upon separation, a measurement never before performed. Other measurement techniques unique to this study include; surface potential measurements of insulators before, during and after contact and separation, as well as methods to verify fieldmeter calibrations using a charge insulator surface opposed to standard high voltage plates. Key words: Kapton polyimide film, incendiary discharges, brush discharges, contact and frictional electrification, ignition hazards, insulators, contact angle, surface potential measurements.

Buhler, Charles↗

SeaWiFS Technical Report Series: SeaWiFS Calibration Topics - Volume 40

For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The SeaWiFS bands, however, have nominal spectral bandwidths of 20 and 40 nm. These bandwidths effect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. The spectral shape of that radiance will not be well known on orbit. In this technical memorandum, two source spectra are examined. The first is a 12,000 K Planck function, and the second is based on the modeling results of H. Gordon at the University of Miami. By comparing these spectra, the best available corrections to the SeaWiFS measurements for source spectral shape, plus estimates of the uncertainties in these corrections, can be tabulated.

Barnes, Robert A.↗

An Inverse Chance-constrained Approach to the Calibration of Robust Models

This paper proposes a strategy to calibrate computational models according to uncertain input-output data. To this end, uncertainty in the data is first quantified by creating adversarial data sets. Samples drawn from such sets are then mapped from the input-output space to the parameter space using an inverse mapping. This mapping minimizes the collective output spread of an ensemble of point predictions while satisfying a set of individual data-matching requirements. The distribution of the resulting parameter points, which often exhibits strong parameter dependencies, is then modeled using sliced-normals. The chance-constrained formulation used to learn this distribution enables the analyst to trade-off a greater likelihood for most of the data against a lower likelihood for some of the data thereby relaxing the conservatism of the calibrated model. This formulation not only neglects the worst-performing quantiles of each adversarial distribution but also eliminates the potentially serious effects that outliers might have on the resulting model. This calibration approach not only has a considerably lower computational cost than the standard forward approach but it also allows for the identification of suitable distribution classes, which in turn yield better calibrated models.

Calibration↗

Waste Control Specialists Technical Review Team Report

1. Modeling of Drum 68660 and the WCS Drums: A calibrated model of Los Alamos National Laboratory (LANL) Drum 68660 indicates that pressurization of the drum by restriction of drum venting could have led to the thermal runaway reaction at the Waste Isolation Pilot Plant (WIPP) in 2014, supporting the hypothesis that the contents of the drum were not fundamentally different from the overall remediated nitrate salt (RNS) waste stream. 2. Nitric Acid Reactions and Aging of the Waste: The stability of the WCS RNS waste with respect to autocatalytic thermal runaway due to nitric acid chemistry should increase over time as the nitric acid is depleted from chemical reactions in the drum. However, this cannot be confirmed because of the lack of long-term experimental data on the impact of aging on the reactivity of RNS waste. The calibrated model indicates that the waste drums retain most of their reactive components, metal nitrate salts and sWheat Scoop ® , even after eight years. 3. Pressure Effects and Runaway Reactions: The calibrated model indicates that if the drums and standard waste boxes (SWBs) are not allowed to pressurize during transport or storage and they are stored at historical WIPP repository temperatures, then an autocatalytic thermal runaway event is not expected to occur. Since the cause of Drum 68660 pressurization is not known, decision makers are not able to tailor mitigating strategies to the initiating event. Consequently, mitigating strategies must consider all feasible internal and external events that could lead to the pressurization of the drums. 4. Temperature Effects and Runaway Reactions: Temperature also has a strong influence on the stability of the waste. The calibrated model indicates that cooling the drums or SWBs can reduce the possibility of autocatalytic thermal runaway reactions. Simulations suggest that for a drum with a plugged vent, the probability of thermal runaway may be reduced or eliminated if wastes are maintained at or below 43 °F through active cooling measures from the initiation of transport until emplacement at WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of factors affecting the heater wire method of calibrating fine wire thermocouples

An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.

Keshock, E. G.↗

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

SeaWiFS Technical Report Series: SeaWiFS Calibration Topics - Volume 39

For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) bands, however, have nominal spectral bandwidths of 20 and 40nm. These bandwidths affect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. Currently, SeaWiFS is calibrated such that the digital counts from each instrument band are linked to the Earth-exiting radiance at an individual center wavelength. Before launch, SeaWiFS will be recalibrated so that the digital counts from each band will be linked to the Earth-exiting radiance integrated over the spectral response of that band. In this technical memorandum, the effects of the instrument calibration and the source spectral shape on SeaWiFS measurements, including the in-band and out-of-band responses, and the center wavelengths are discussed.

Hooker, Stanford B.↗

An Altitude Chamber for the Study and Calibration of Aeronautical Instruments

The design and construction of an altitude chamber, in which both pressure and temperature can be varied independently, was carried out by the NACA at the Langley Memorial Aeronautical Laboratory for the purpose of studying the effects of temperature and pressure on aeronautical research instruments. Temperatures from +20c to -50c are obtained by the expansion of CO2from standard containers. The chamber can be used for the calibration of research instruments under altitude conditions simulating those up to 45,000 feet. Results obtained with this chamber have a direct application in the design and calibration of instruments used in free flight research.

Reid, J E↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

Toward Complete Characterization: Prospects for Directly Imaging Transiting Exoplanets

High-contrast direct imaging of exoplanets can provide many important observables, including measurements of the orbit, spectra that probe the lower layers of the atmosphere, and phase variations of the planet, but cannot directly measure planet radius or mass. Our future understanding of directly imaged exoplanets will therefore rely on extrapolated models of planetary atmospheres and bulk composition, which need robust calibration. We estimate the population of extrasolar planets that could serve as calibrators for these models. Critically, this population of “standard planets” must be accessible to both direct imaging and the transit method, allowing for radius measurement. We show that the search volume of a direct imaging mission eventually overcomes the transit probability falloff with semimajor axis, so that as long as cold planets are not exceedingly rare, the population of transiting planets and directly imageable planets overlaps. Using current extrapolations of Kepler occurrence rates, we estimate that ∼8 standard planets could be characterized shortward of 800 nm with an ambitious future direct imaging mission like LUVOIR-A and several dozen could be detected at the V band. We show the design space that would expand the sample size and discuss the extent to which ground- and space-based surveys could detect this small but crucial population of planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of VIIRS on-orbit polarization sensitivity and its impact on CLARREO pathfinder inter-calibration

The primary objective of the CLARREO Pathfinder (CPF) mission is to demonstrate essential measurement technologies to enable highly accurate decadal change observations traceable on-orbit to SI standards. Another important objective of the CPF is to demonstrate inter-calibration with the VIIRS sensor and to show that such high-accuracy reference inter-calibration is achievable. To satisfy this requirement, it is important to understand and quantify uncertainties in VIIRS sensor measurements. Based on prelaunch test results, the reflective solar bands of both SNPP and NOAA-20 VIIRS have exhibited polarization sensitivities in the shortest wavelength bands, with an unexpectedly larger sensitivity observed for NOAA-20 VIIRS, particularly in bands M1 to M4. In this study, we use VIIRS Level-1B reflectance data collected over the Pseudo-Invariant Calibration Sites over North African desert region to examine the polarization associated uncertainty for these four bands. Impact due to BRDF on the reflectance data is considered by comparing baseline results obtained from the same viewing and solar zenith angles under relatively low polarization sensitivity. Impact due to detector relative difference in polarization sensitivity is examined by normalizing reflectances by the value of the middle detector. Results of this study provide useful information on VIIRS uncertainty contribution due to polarization when conducting CPF and VIIRS inter-calibration.

VIIRS↗

Model-Form Epistemic Uncertainty Quantification for Modeling with Differential Equations: Application to Epidemiology

Modeling real-world phenomena to any degree of accuracy is a challenge that the scientific research community has navigated since its foundation. Lack of information and limited computational and observational resources necessitate modeling assumptions which, when invalid, lead to model-form error (MFE). The work reported herein explored a novel method to represent model-form uncertainty (MFU) that combines Bayesian statistics with the emerging field of universal differential equations (UDEs). The fundamental principle behind UDEs is simple: use known equational forms that govern a dynamical system when you have them; then incorporate data-driven approaches – in this case neural networks (NNs) – embedded within the governing equations to learn the interacting terms that were underrepresented. Utilizing epidemiology as our motivating exemplar, this report will highlight the challenges of modeling novel infectious diseases while introducing ways to incorporate NN approximations to MFE. Prior to embarking on a Bayesian calibration, we first explored methods to augment the standard (non-Bayesian) UDE training procedure to account for uncertainty and increase robustness of training. In addition, it is often the case that uncertainty in observations is significant; this may be due to randomness or lack of precision in the measurement process. This uncertainty typically manifests as “noisy” observations which deviate from a true underlying signal. To account for such variability, the NN approximation to MFE is endowed with a probabilistic representation and is updated using available observational data in a Bayesian framework. By representing the MFU explicitly and deploying an embedded, data-driven model, this approach enables an agile, expressive, and interpretable method for representing MFU. In this report we will provide evidence that Bayesian UDEs show promise as a novel framework for any science-based, data-driven MFU representation; while emphasizing that significant advances must be made in the calibration of Bayesian NNs to ensure a robust calibration procedure.

97 MATHEMATICS AND COMPUTING↗

Binary pseudorandom test standard to determine the modulation transfer function of optical microscopes

This work reports on the development of a binary pseudo-random test sample optimized to calibrate the MTF of optical microscopes. The sample consists of a number of 1-D and 2-D patterns, with different minimum sizes of spatial artifacts from 300 nm to 2 microns. We describe the mathematical background, fabrication process, data acquisition and analysis procedure to return spatial frequency based instrument calibration. We show that the developed samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗