Search NASA⌕ Search

SEARCH · Search NASA

Results for “Event detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Waste heat recovery system for recapturing energy after engine aftertreatment systems

The disclosure provides a waste heat recovery (WHR) system including a Rankine cycle (RC) subsystem for converting heat of exhaust gas from an internal combustion engine, and an internal combustion engine including the same. The WHR system includes an exhaust gas heat exchanger that is fluidly coupled downstream of an exhaust aftertreatment system and is adapted to transfer heat from the exhaust gas to a working fluid of the RC subsystem. An energy conversion device is fluidly coupled to the exhaust gas heat exchanger and is adapted to receive the vaporized working fluid and convert the energy of the transferred heat. The WHR system includes a control module adapted to control at least one parameter of the RC subsystem based on a detected aftertreatment event of a predetermined thermal management strategy of the aftertreatment system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Drug development and manufacturing

X-ray fluorescence (XRF) spectrometry has been used for detecting binding events and measuring binding selectivities between chemicals and receptors. XRF may also be used for estimating the therapeutic index of a chemical, for estimating the binding selectivity of a chemical versus chemical analogs, for measuring post-translational modifications of proteins, and for drug manufacturing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced drug development and manufacturing

X-ray fluorescence (XRF) spectrometry has been used for detecting binding events and measuring binding selectivities between chemicals and receptors. XRF may also be used for estimating the therapeutic index of a chemical. For estimating the binding selectivities of a chemical versus chemical analogs, for measuring post translational modification of proteins, and for drug manufacturing.

Birnbaum, Eva R.↗

Preemptive signal integrity control

Techniques are provided herein for pre-emptively reinforcing one or more buses of a computing device against the effects of signal noise that could cause a reduction in signal integrity. The techniques generally include detecting an event (or “trigger”) that would tend to indicate that a reduction in signal integrity will occur, examining a reinforcement action policy and system status to determine what reinforcement action to take, and performing the reinforcement action.

Roberts, David A.↗

Environmental sampling at Amchitka and Adak Islands, Alaska - 15317

Amchitka Island is near the western end of the Aleutian Islands, approximately 2157 km (1340 miles) west-southwest of Anchorage, Alaska. The US government conducted three underground nuclear tests on Amchitka between 1965 and 1971 and has conducted biological monitoring on the island since before 1965; the most recent monitoring occurred in the summer of 2011. A working group of stakeholders collected samples of marine biota, sediment, and sea water for analysis of test-related radionuclides to determine if subsistence- and commercial-catch seafood in the ocean near Amchitka and Adak Island (a reference area) is safe to eat. Dietary intake information for the risk estimates used a range of diets based on published surveys of four Aleut villages and a composite diet. The risk estimates indicated that seafood harvested at Amchitka and Adak is considered safe for consumption at the intake levels for each of five diets evaluated. Although increased cesium concentrations (Cs-134) possibly related to the Fukushima Dai-ichi event were detected in certain samples; the increased levels have not resulted in unacceptable risk from the ingestion of these seafoods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Persistent Acoustic Sensing for Monitoring A Reactor Facility - Oral Presentation

Measurements over the past few years, taking place within the Multi-Informatics for Nuclear Operations Scenarios (MINOS) project, show that infrasound and low-frequency acoustic monitoring can detect, and often quantify, activities that occur on-site at a large research reactor. Observable activities include: crane translation, lifting, and lowering; differentiation between loaded and unloaded crane operations; access door opening and closing; vehicle operations; and cooling tower fan operation. Advanced data analytic and spectral feature extraction methods can be used to interpret selected signatures to reach a deeper understanding of different reactor activities. These measurements are being conducted using a network of smartphones that continuously operate in conjunction with cloud-based architectures. A recent addition to the system is the development and deployment of a real-time, cloud-based analytic framework that supports near-real-time alarming which can facilitate tip-and-cue protocols. This paper will present recent research advances in this area including studies to explore the transferability of learned parameters from one smartphone to another, the detectability of events from multiple sensors at different locations simultaneously, and the feasibility of porting analytical tools directly to the smartphones to allow edge computing with optimized configurations.

42 ENGINEERING↗

Combined PET/MRI scanner

A combined PET/MRI scanner generally includes a magnet for producing a magnetic field suitable for magnetic resonance imaging, a radiofrequency (RF) coil disposed within the magnetic field produced by the magnet and a ring tomograph disposed within the magnetic field produced by the magnet. The ring tomograph includes a scintillator layer for outputting at least one photon in response to an annihilation event, a detection array coupled to the scintillator layer for detecting the at least one photon outputted by the scintillator layer and for outputting a detection signal in response to the detected photon and a front-end electronic array coupled to the detection array for receiving the detection signal, wherein the front-end array has a preamplifier and a shaper network for conditioning the detection signal.

47 OTHER INSTRUMENTATION↗

Development of a HT seismic downhole tool.

Enhanced Geothermal Systems (EGS) require the stimulation of the drilled well, likely through hydraulic fracturing. Whether fracturing of the rock occurs by shear destabilization of natural fractures or by extensional failure of weaker zones, control of the fracture process will be required to create the flow paths necessary for effective heat mining. As such, microseismic monitoring provides one method for real-time mapping of the fractures created during the hydraulic fracturing process. This monitoring is necessary to help assess stimulation effectiveness and provide the information necessary to properly create the reservoir. In addition, reservoir monitoring of the microseismic activity can provide information on reservoir performance and evolution over time. To our knowledge, no seismic tool exists that will operate above 125 C for the long monitoring durations that may be necessary. Replacing failed tools is costly and introduces potential errors such as depth variance, etc. Sandia has designed a high temperature seismic tool for long-term deployment in geothermal applications. It is capable of detecting microseismic events and operating continuously at temperatures up to 240 C. This project includes the design and fabrication of two High Temperature (HT) seismic tools that will have the capability to operate in both temporary and long-term monitoring modes. To ensure the developed tool meets industry requirements for high sampling rates (>2ksps) and high resolution (24-bit Analog-to-Digital Converter) two electronic designs will be implemented. One electronic design will utilize newly developed 200 C electronic components. The other design will use qualified Silicon-on-Insulator (SOI) devices and will have a continuous operating temperature of 240 C.

15 GEOTHERMAL ENERGY↗

R-Matrix Analysis of the 236 U(n,gamma) Reaction in theResolved Resonance Energy Region

The neutron capture cross section of 236U was measured in the neutron energy range from 1 eV to 10 keV by the neutron time-of-flight method at the GELINA white pulsed neutron source of the Institute for Reference Materials and Measurements (IRMM) in Geel (Belgium). The gamma rays originating from neutron capture events were detected by two C6D6-based liquid scintillators using the pulse height weighting technique. The weighting function has been derived from Monte-Carlo simulations of the detector response to monoenergetic gamma rays. The sample under investigation with a total amount of 338 mg of 236U was located in the neutron beam at a distance of 28.6 m from the source. The shape of the neutron flux was determined by a 10B neutron counter, placed approximately 60 cm upstream in the neutron beam line. The neutron capture yield in the resolved resonance region up to 1 keV has been derived from time-of-flight spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

XMM-NEWTON SLEW SURVEY OBSERVATIONS OF THE GRAVITATIONAL WAVE EVENT GW150914

The detection of the first gravitational wave (GW) transient GW150914 prompted an extensive campaign of follow-up observations at all wavelengths. Although no dedicated XMM-Newton observations have been performed, the satellite passed through the GW150914 error region during normal operations. Here we report the analysis of the data taken during these satellite slews performed two hours and two weeks after the GW event. Our data cover 1.1 and 4.8 deg{sup 2} of the final GW localization region. No X-ray counterpart to GW150914 is found down to a sensitivity of 6 × 10{sup −13} erg cm{sup −2} s{sup −1} in the 0.2–2 keV band. Nevertheless, these observations show the great potential of XMM-Newton slew observations for searching for the electromagnetic counterparts of GW events. A series of adjacent slews performed in response to a GW trigger would take ≲1.5 days to cover most of the typical GW credible region. We discuss this scenario and its prospects for detecting the X-ray counterpart of future GW detections.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Scheduling: Target of Opportunity Observations of Gravitational Wave Events

The simultaneous detection of electromagnetic and gravitational waves from the coalescence of two neutron stars (GW170817 and GRB170817A) has ushered in a new era of ‘multimessenger’ astronomy, with electromagnetic detections spanning from gamma to radio. This great opportunity for new scientific investigations raises the issue of how the available multimessenger tools can best be integrated to constitute a powerful method to study the transient Universe in particular. To facilitate the classification of possible optical counterparts to gravitational wave events, it is important to optimize the scheduling of observations and the filtering of transients, both key elements of the follow-up process. In this work, we describe the existing workflow whereby telescope networks such as GRANDMA and GROWTH are currently scheduled; we then present modifications we have developed for the scheduling process specifically, so as to face the relevant challenges that have appeared during the latest observing run of Advanced LIGO and Advanced Virgo. We address issues with scheduling more than one epoch for multiple fields within a skymap, especially for large and disjointed localizations. This is done in two ways: by optimizing the maximum number of fields that can be scheduled and by splitting up the lobes within the skymap by right ascension to be scheduled individually. In addition, we implement the ability to take previously observed fields into consideration when rescheduling. We show the improvements that these modifications produce in making the search for optical counterparts more efficient, and we point to areas needing further improvement.

Gravitational waves↗

Measurement of the total cross section of the reaction K{sup -}p{yields}{sigma}{sup 0}{gamma} between 514 and 750 MeV/c

We report the first measurements of the total cross section of the reaction K{sup -}p{yields}{sigma}{sup 0}{gamma} at eight beam momenta from 514 to 750 MeV/c. The data were obtained at the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory using the Crystal Ball detector consisting of 672 NaI crystals. All charged particles were vetoed by a barrel of plastic scintillators, resulting in a study of only the neutral decays of the {sigma}{sup 0}. The prompt photon and the photons from the decay products of {sigma}{sup 0} were detected for each reconstructed event; the neutron was also detected in a small fraction of the events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiochemical Sensor for Continuous and Remote Liquid Effluents Monitoring

On-line radioactivity monitoring in liquid effluents is an increasing need according to the international regulations at present. Classical activity determination procedures include the sequence of sampling, chemical treatment, measurement and data treatment. These steps are man-power consuming, generate a great amount of waste and introduce an important delay between the potential pollution event and its detection and quantification. To overcome these limitations, we have developed a radiochemical sensor for liquid effluents capable of sending information about the specific activity and volume of a contamination episode to a remote position, on line and continuously. The capabilities of the sensor developed here allow detecting and quantifying contamination pulses of alpha, beta and gamma emitters of different volumes and activity levels included in a continuous stream. Sensor receptor includes two detection systems, one addressed to determine alpha, beta and gamma events and the other to detect sample gamma emissions. Detailed sensor structure will be shown at the conference because patent is in process at this moment. Detection efficiencies (%) obtained in the alpha-beta-gamma system for the range of contamination volumes considered (2- 300 ml) are: 1.6 - 3.2%, for Pu-240; 22.2 - 58.4%, for Sr-90/Y-90 and 8.8 -17.7%, for Cs-134. In the gamma system, values for Cs-134 detection range from 0.6% to 1.3%. Prediction errors obtained show that sensor is capable to detect Sr-90/Y-90 contamination pulses of at least 2 ml and 3 Bq/ml with a relative error lower of 10% in activity and 60% in volume. When contamination pulse increases up to 7 ml, relative errors decrease to 5% for both magnitudes. For Pu-240 and Cs-134, when contamination pulses are of at least 7 ml and 300 Bq/ml, the relative errors obtained in determinations performed in the alpha-beta-gamma system are lower than 10% in activity and 20 % in volume. The same errors are obtained in the gamma system for Cs-134 when contamination pulses are higher than 7 ml and activities up to 1300 Bq/ml. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Martian seismicity

During the Viking mission to Mars, the seismometer on Lander II collected approximately 0.24 earth years of observational data, excluding periods of time dominated by wind-induced Lander vibration. The 'quiet-time' data set contains no confirmed seismic events. A proper assessment of the significance of this fact requires quantitative estimates of the expected detection rate of the Viking seismometer. The first step is to calculate the minimum magnitude event detectable at a given distance, including the effects of geometric spreading, anelastic attenuation, seismic signal duration, seismometer frequency response, and possible poor ground coupling. Assuming various numerical quantities and a Martian seismic activity comparable to that of intraplate earthquakes, the appropriate integral gives an expected annual detection rate of 10 events, nearly all of which are local. Thus only two to three events would be expected in the observational period presently on hand and the lack of observed events is not in gross contradiction to reasonable expectations. Given the same assumptions, a seismometer 20 times more sensitive than the present instrument would be expected to detect about 120 events annually.

Goins, N. R.↗

Effect of Baseline Period on Quantification of Climate Extremes over the United States

Extreme weather events, including heatwaves, heavy precipitation, and drought, have a large impact on society through human health, destruction of infrastructure, ecological change, and economic losses. Reanalyses such as NASA’s Modern Era Retrospective Analysis, version 2 (MERRA-2) are a valuable tool for analyzing past extreme events to determine their underlying causes and how extremes have changed over the past four decades. The detection of extreme events relies on a threshold for precipitation or temperature that is derived using a reference period, which can then be used to determine how extreme an event was or what the return period is. Operational centers typically use a 30-year climatology period that shifts in time every ten years, while the World Meteorological Organization suggests that the maximum amount of data should be included for the detection of extreme events due to their rare occurrence. As global and regional climate continues to change, the interpretation of extreme events is reliant on the baseline period that is used for the underlying thresholds and can be a source of uncertainty for the policy making community. Three baseline periods – 1981-2010, 1991-2020, and 1981-2020 – will be used to compute percentiles of temperature and precipitation across the contiguous United States and will then by employed to determine monthly indices representing heatwaves, cold spells, and extreme precipitation events. A spatial and temporal analysis of the resulting extreme weather indices will demonstrate the appropriateness for each baseline period for the evaluation of extreme events.

Extremes↗

Applying Waveform Correlation to Reduce Seismic Analyst Workload Due to Repeating Mining Blasts

Agencies that monitor for underground nuclear tests are interested in techniques that automatically characterize mining blasts to reduce the human analyst effort required to produce high–quality event bulletins. Waveform correlation is effective in finding similar waveforms from repeating seismic events, including mining blasts. We report the results of an experiment to detect and identify mining blasts for two regions, Wyoming (U.S.A.) and Scandinavia, using waveform templates recorded by multiple International Monitoring System stations of the Preparatory Commission for the Comprehensive Nuclear–Test–Ban Treaty Organization (CTBTO PrepCom) for up to 10 yr prior to the time of interest. We discuss approaches for template selection, threshold setting, and event detection that are specialized for characterizing mining blasts using a sparse, global network. We apply the approaches to one week of data for each of the two regions to evaluate the potential for establishing a set of standards for waveform correlation processing of mining blasts that can be generally applied to operational monitoring systems with a sparse network. Here, we compare candidate events detected with our processing methods to the Reviewed Event Bulletin of the International Data Centre to assess potential reduction in analyst workload.

58 GEOSCIENCES↗

Detection Limits and Near‐Field Ground Motions of Fast and Slow Earthquakes

Abstract We investigate theoretical limits to detection of fast and slow seismic events, and spatial variations of ground motion expected from M 6 earthquakes at short epicentral distances. The analyses are based on synthetic velocity seismograms calculated with the discrete wavenumber method assuming seismic velocities and attenuation properties of the crust in Southern California. The examined source properties include different magnitudes ( M −1.0 to M 6.0), static stress drops (0.1–10 MPa), and slow and fast ruptures (0.1–0.9 of shear wave velocity). For the M 6 events we also consider variations in rise times producing crack‐ and pulse‐type events and different rupture directivities. Slow events produce ground motion with considerably lower amplitude than corresponding regular fast earthquakes with the same magnitude, and hence are significantly more difficult to detect. The static stress drop and slip rise time also affect the maximum radiated seismic motion, and hence event detectability. Apart from geometrical factors, the saturation and depletion of seismic ground motion at short epicentral distances stem from radiation pattern, earthquake size (magnitude, stress drop), and rupture directivity. The rupture velocity, rise time, and directivity affect significantly the spatial pattern of the ground motions. The results can help optimizing detection of slow and fast small earthquakes and understand the spatial distribution of ground motion generated by large events.

58 GEOSCIENCES↗