Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A Thin Alumina Film as a Tritium Adsorption Inhibitor for Stainless Steel 316

The effect of a thin alumina coating on stainless-steel 316 (SS316) samples on tritium adsorption and transport are discussed. Compact films of alumina were produced on the surfaces of pristine SS316 samples using an atomic layer deposition (ALD) technique. Subsequently, these samples were exposed for 24 hours to a deuterium-tritium gas mixture (P T =0.5 atm, 25°C). A combination of methods including selective-etching and programmed thermal desorption were employed to assess both, the depth profile of the tritium concentration in the sample and the total quantity of tritium absorbed respectively. Tritium was quantitatively determined through the measurement of beta radioactivity using liquid-scintillation counting techniques. Data suggest that SS316 with a thin film of alumina reduces the total tritium uptake by ~25% relative to uncoated samples. Significantly, such films appear to reduce, by a factor of 200, tritium diffusion into SS316 and therefore constitute an effective barrier against tritium transport. This observation is of practical importance for tritium and, generally, reactive gas handling.

36 MATERIALS SCIENCE↗

Application of a novel TPR EXAFS/XANES method using a multi-sample holder to characterize promoted iron and cobalt fFischer-Tropsch synthesis catalysts.

Coal-to-liquids. Iron-based Fischer-Tropsch synthesis catalysts are not only used commercially for high temperature Fischer-Tropsch synthesis, but are increasingly becoming the focus for converting low H{sub 2}/CO ratio synthesis gas at lower temperature. Such low temperature processing yields hydrocarbon distributions with higher {alpha} values, and as a consequence, much less light hydrocarbon gas production (and especially, less methane). Another benefit to the use of iron-based catalysts is that the product slate is richer in {alpha}-olefinic products, which are more valuable than the paraffinic products produced using cobalt-based catalysts. Iron-based catalysts are often used to convert low H{sub 2}/CO ratio syngas, because the catalysts can intrinsically adjust the syngas ratio upward by converting a fraction of CO by reaction with H{sub 2}O to produce H{sub 2} and CO{sub 2} via the water-gas shift reaction.

01 COAL, LIGNITE, AND PEAT↗

Stainless Steel to Titanium Bimetallic Transitions

In order to use stainless steel piping in an LCLS-II (Linac Coherent Light Source Upgrade) cryomodule, stainless steel to titanium bimetallic transitions are needed to connect the stainless steel piping to the titanium cavity helium vessel. Explosion bonded stainless steel to titanium transition pieces and bimetallic transition material samples have been tested. A sample transition tube was subjected to tests and x-ray examinations between tests. Samples of the bonded joint material were impact and tensile tested at room temperature as well as liquid helium temperature. The joint has been used successfully in horizontal tests of LCLS-II cavity helium vessels and is planned to be used in LCLS-II cryomodules. Results of material sample and transition tube tests will be presented.

43 PARTICLE ACCELERATORS↗

Synthesis of flower-like Boehmite (γ-AlOOH) via a one-step ionic liquid-assisted hydrothermal route

A simple and novel synthesis process, one-step ionic liquid-assisted hydrothermal synthesis route, has been developed in the work to synthesize Bohemithe (γ-AlOOH) with flower-like structure. The samples were characterized by X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FT-IR) and Scanning Electron Microscope (SEM). Ionic liquid [Omim]{sup +}Cl{sup −}, as a template, plays an important role in the morphology and pore structure of the products due to its strong interactions with reaction particles. With the increase in the dosage of ionic liquid [Omim]{sup +}Cl{sup −}, the morphology of the γ-AlOOH was changed from initial bundles of nanosheets (without ionic liquid) into final well-developed monodispersed 3D flower-like architectures ([Omim]{sup +}Cl{sup −}=72 mmol). The pore structure was also altered gradually from initial disordered slit-like pore into final relatively ordered ink-bottle pore. Furthermore, the proposed formation mechanism and other influencing factors such as reaction temperature and urea on formation and morphology of the γ-AlOOH have also been investigated. - Graphical abstract: The flower-like γ-AlOOH architectures composed by nanosheets with narrow size distribution (1.6–2.2 μm) and uniform pore size (6.92 nm) have been synthesized via a one-step ionic liquid-assisted hydrothermal route. - Highlights: • The γ-AlOOH microflowers were synthesized via an ionic liquid-assisted hydrothermal route. • Ionic liquid plays an important role on the morphology and porous structure of the products. • Ionic liquid can be easily removed from the products and reused in recycling experiments. • A “aggregation–recrystallization–Ostwald Ripening“formation mechanism may occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Helium gas bubble trapped in liquid helium in high magnetic field

High magnetic field magnets are used widely in the area of the condensed matter physics, material science, chemistry, geochemistry, and biology at the National High Magnetic Field Laboratory. New high field magnets of state-of-the-art are being pursued and developed at the lab, such as the current developing 32 T, 32 mm bore fully superconducting magnet. Liquid Helium (LHe) is used as the coolant for superconducting magnets or samples tested in a high magnetic field. When the magnetic field reaches a relatively high value the boil-off helium gas bubble generated by heat losses in the cryostat can be trapped in the LHe bath in the region where BzdBz/dz is less than negative 2100 T{sup 2}/m, instead of floating up to the top of LHe. Then the magnet or sample in the trapped bubble region may lose efficient cooling. In the development of the 32 T magnet, a prototype Yttrium Barium Copper Oxide coil of 6 double pancakes with an inner diameter of 40 mm and an outer diameter of 140 mm was fabricated and tested in a resistive magnet providing a background field of 15 T. The trapped gas bubble was observed in the tests when the prototype coil was ramped up to 7.5 T at a current of 200 A. This letter reports the test results on the trapped gas bubble and the comparison with the analytical results which shows they are in a good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Protein-based forensic identification using genetically variant peptides in human bone

Bone tissue contains organic material that is useful for forensic investigations and may contain preserved endogenous protein that can persist in the environment for extended periods of time over a range of conditions. Single amino acid polymorphisms in these proteins reflect genetic information since they result from non-synonymous single nucleotide polymorphisms (SNPs) in DNA. Detection of genetically variant peptides (GVPs) — those peptides that contain amino acid polymorphisms — in digests of bone proteins allows for the corresponding SNP alleles to be inferred. Resulting genetic profiles can be used to calculate statistical measures of association between a bone sample and an individual. In this study proteomic analysis on rib cortical bone samples from 10 recently deceased individuals demonstrates this concept. A straight-forward acidic demineralization protocol yielded proteins that were digested with trypsin. Tryptic digests were analyzed by liquid chromatography mass spectrometry. A total of 1736 different proteins were identified across all resulting datasets. On average, individual samples contained 454 ± 121 ($\bar{x}$ ± σ) proteins. Thirty-five genetically variant peptides were identified from 15 observed proteins. Overall, 134 SNP inferences were made based on proteomically detected GVPs, which were confirmed by sequencing of subject DNA. Inferred individual SNP genetic profiles ranged in random match probability (RMP) from 1/6 to 1/42,472 when calculated with European population frequencies in the 1000 Genomes Project, Phase 3. Similarly, RMPs based on African population frequencies were calculated for each SNP genetic profile and likelihood ratios (LR) were obtained by dividing each European RMP by the corresponding African RMP. In conclusion, resulting LR values ranged from 1.4 to 825 with a median value of 16. GVP markers offer a basis for the identification of compromised skeletal remains independent of the presence of DNA template.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid, Untargeted Chemical Profiling of Single Cells in Their Native Environment

We report a method that enables untargeted, high throughput, and quantitative mass spectrometric analysis of single cells from cell suspension without needing additional sample preparation procedures (e.g., molecular tagging) through the combination of single-cell printer technology and liquid vortex capture–mass spectrometry (SCP-LVC-MS). The operating principle behind the SCP-LVC-MS technology is single cell isolation via small droplet piezoelectric ejection followed by capture of the droplet into an LVC-MS sampling probe. Once exposed to an appropriate solvent, the cell is lysed, extracted, and analyzed by MS. The SCP-LVC-MS approach was validated by measuring the lipid composition of microalgae, Chlamydomonas reinhardtii (ChRe) and Euglena gracilis (EuGr), and HeLa cells in their native growth media. Numerous diacylglyceryltrimethylhomo-Ser (DGTS), phosphatidylcholine (PC), monogalactosyldiacylglycerol (MGDG), and digalactosyldiacylglycerol (DGDG) lipids were observed in single cells. Continuous solvent flow ensures that cells are analyzed rapidly, and no signal carryover between cells is observed. ChRe and EuGr microalgae mixed together in the same solution were differentiated cell-by-cell in real-time based on differences between levels of diacylglyceryltrimethylhomo-Ser (DGTS) and phosphatidylcholine (PC) lipids measured in each cell. Several DGTS lipids present in ChRe were quantified with single-cell resolution by normalizing to a DGTS(32:0) internal standard added to the LVC probe solvent during analysis. Quantitative peak areas were validated by comparing to bulk lipid extracts. Furthermore, peak area distributions comprised of hundreds of cells were compared for ChRe after 5 days of nitrogen-limited and normal growth conditions, which show clear differences and the ability to resolve cellular population differences with single-cell resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization method, purge flow rate was determined to be highly correlated with increased response (p=0.023). Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. This method represents a decrease in sample handling and processing over currently standard methods and represents a more amenable method for purgeable mercury analysis in liquid nuclear waste.1 An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly Tank 50 samples. Two samples demonstrated no statistically significant difference (p=0.271, p=0.0811), with one sample biased 30% low to a statistically significant degree (p=0.0432). Large mean uncertainty was present in the results reported by both laboratories (±15% and 40% from SRNL and Eurofins), with no significant difference observed in uncertainty (p=0.934). Across all co-analyzed samples, no significantly difference was observed in precision (p=0.205) or reported values (p=0.352) between SRNL and Eurofins. These results indicate that SRNL-AD may provide data to the customer of statistically similar quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heating experiments of the Tagish Lake meteorite: Investigation of the effects of short-term heating on chondritic organics

We present in this study the effects of short-term heating on organics in the Tagish Lake meteorite and how the difference in the heating conditions can modify the organic matter (OM) in a way that complicates the interpretation of a parent body's heating extent with common cosmothermometers. The kinetics of short-term heating and its influence on the organic structure are not well understood, and any study of OM is further complicated by the complex alteration processes of the thermally metamorphosed carbonaceous chondrites—potential analogues of the target asteroid Ryugu of the Hayabusa2 mission—which had experienced posthydration, short-duration local heating. In an attempt to understand the effects of short-term heating on chondritic OM, we investigated the change in the OM contents of the experimentally heated Tagish Lake meteorite samples using Raman spectroscopy, scanning transmission X-ray microscopy utilizing X-ray absorption near edge structure spectroscopy, and ultraperformance liquid chromatography fluorescence detection and quadrupole time of flight hybrid mass spectrometry. Our experiment suggests that graphitization of OM did not take place despite the samples being heated to 900 °C for 96 h, as the OM maturity trend was influenced by the heating conditions, kinetics, and the nature of the OM precursor, such as the presence of abundant oxygenated moieties. Although both the intensity of the 1s-σ* exciton cannot be used to accurately interpret the peak metamorphic temperature of the experimentally heated Tagish Lake sample, the Raman graphite band widths of the heated products significantly differ from that of chondritic OM modified by long-term internal heating.

Chan, Queenie H. S.↗

Non-Isochronal Behavior of Charge Transport at Liquid–Liquid and Liquid–Glass Transition in Aprotic Ionic Liquids

A reversible, first-order transition separating two liquid phases of a single-component material is a fascinating yet poorly understood phenomenon. Here, we investigate the liquid–liquid transition (LLT) ability of two tetraalkylphosphonium ionic liquids (ILs), [P 666,14 ]Cl and [P 666,14 ][1,2,4-triazolide], using differential scanning calorimetry and dielectric spectroscopy. The latter technique also allowed us to study the LLT at elevated pressure. We found that cooling below 205 K transforms [P 666,14 ]Cl and [P 666,14 ][Trz] from one liquid state (liquid 1) to another (the self-assembled liquid 2), while the latter facilitates the charge transport decoupled from structural dynamics. In contrast to temperature, pressure was found to play an essential role in the self-organization of a liquid 2 phase, resulting in different time scales of charge transport for rapidly and slowly compressed samples. Furthermore, τ σ (P LL ) was found to be much shorter than τ σ (T LL , P=atm), which constitutes the first example of non-isochronal behavior of charge transport at LLT. In turn, dielectric studies through the liquid–glass transition revealed the non-monotonic behavior of τ σ at elevated pressure for [P 666,14 ]Cl, while for [P 666,14 ][Trz] τ σ (P g ) was almost constant. These results highlight the diversity of liquid–liquid transition features within the class of phosphonium ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges to Collection of High Quality Samples of Saltstone - 17468

The Savannah River Site (SRS) Saltstone Disposal Facility (SDF) is used to dispose of low-level radioactive liquid waste in the form of grout. The SDF is comprised of a series of concrete saltstone disposal units (SDUs) that receive the grout. The grout solidifies into a cementitious waste form known as saltstone. Properties of saltstone that influence contaminant release have been measured on simulant material but not on samples of emplaced saltstone because samples of emplaced radioactive saltstone are difficult to obtain, transport, and store in a manner that protects the properties of interest. Savannah River Remediation (SRR) initiated a project to obtain samples of emplaced saltstone such that the two critical properties, hydraulic conductivity and reduction capacity, are negligibly impacted by the sample collection effort. The sample collection project was established to manage sample collection efforts beginning with sample collection mock-up activities through field execution. The project focused on three phases: mock-up in a clean environment, development of equipment needed to maintain an inert environment during sample transport and laboratory storage, and coordination of Facility operations and support resources and schedules to support sample collection. A mock-up facility was constructed at SRS to mimic the SDU. Core drill equipment was tested, procedures developed, and operator training conducted using the mockup facility. Concurrent with mock-up activities, inert transportation and storage equipment was designed, manufactured, tested, and specific operating instruction included in the sample collection procedure. Inerting equipment minimized oxidation from the atmosphere as the samples were removed from the disposal unit, transported, and stored in the laboratory awaiting analysis. Coordination with the Saltstone Facility began during construction of the mock-up platform to collect current as-built information for platform construction. Baseline data was collected from the disposal unit vapor space to assess the potential for personnel exposure from chemical hazards associated with trapped vapors. Based on this data, mitigating actions were incorporated into the project scope. Finally, project and facility schedules were integrated to assure that facility non-processing windows, support personnel, equipment fabrication, and field preparation activities were in alignment and supportive of the overall sample collection objectives. During May 2014, 485 linear cm of approximately 5 cm diameter radioactive core material was successfully collected from three access ports in SDU Cell 2A, inerted, transported to the laboratory, and stored in an inert environment for analysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rapid Microfluidic Neptunium Extraction Using a Supported Liquid Membrane Module

Extraction of neptunium from acidic matrices is important for its quantification, but its complex redox chemistry can cause variable yields. This study develops a microfluidic redox extraction for rapidly separating neptunium from submilliliter samples, achieving up to 90% process yield in less than 10 min for samples as small as 100 μL, with over 97% steady-state yield achieved after 20 min. It uses a supported liquid membrane module loaded with 30 vol % tributyl phosphate in n-dodecane, which performs forward- and back-extractions in a single, continuous step. Neptunium is first oxidized to +6 for extraction and then reduced during stripping. Bromate was selected as an oxidant over permanganate for its greater compatibility with the organic phase, achieving complete oxidation in under 30 s. Ascorbic acid and hydrogen peroxide were both effective reductants. Finally, the system’s high yield and rapid kinetics make it promising for future separations from complex mixtures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multivariate Linear Models for In Situ Monitoring of Low-Activity Nuclear Waste Using Infrared and Raman Spectroscopy - 20218

This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 22 Supernate Sample Characterization for Select Radionuclides

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR), through a Technical Assistance Request (G-TAR-H-00007) to provide additional sample characterization on unfiltered Tank 22 supernate identified as sample HTF-22-18-117, which was delivered to SRNL Shielded Cells on December 14, 2018. A summary of the average analytical results for this unfiltered Tank 22 supernate liquid follows. The density of the unfiltered Tank 22 supernate is 1.008 g/mL, 0.2%RSD. The Tank 22 supernate sample was analyzed for a total of 45 radionuclide species, with 15 of these radionuclides showing activity levels above minimum detectable activity of at least one replicate. Cesium-137 showed the highest activity at 2.90E+07 dpm/mL, 2.35 %RSD (1.30E-02 Ci/ L) with U-235 showing the lowest measurable activity at an average of 1.66E-01 dpm/mL, 6.26 %RSD (7.49E-11 Ci/L). The primary beta emitting radionuclides in the unfiltered Tank 22 supernate sample include Sr-90, Y-90 and Cs-137 at average activity concentrations of 1.10E-05, 1.10E-05 and 1.30E-02 Ci/L, respectively. The primary gamma emitting radionuclide is Ba-137 m at an average activity concentration of 1.23E-02 Ci/L (note that the activity concentration for Ba-137 m was calculated as 94.7% the Cs-137 activity concentration).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 24 keV liquid-metal-jet x-ray source for biomedical applications

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 {mu}m full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K{sub {alpha}} line is 3 x 10{sup 9} photons/(s x mm{sup 2}x mrad{sup 2}x 0.1% BW) at 30 W electron-beam power. The high photon energy compared to existing liquid-metal-jet sources increases the penetration depth and allows imaging of thicker samples. The applicability of the source in the biomedical field is demonstrated by high-resolution imaging of a mammography phantom and a phase-contrast angiography phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic characterization of Au clusters in vapor-liquid-solid grown silicon nanowires

By correlating atom probe tomography with other conventional microscope techniques (scanning electron microscope, scanning transmission electron microscope, and scanning tunneling microscopy), the distribution and composition of Au clusters in individual vapor-liquid-solid grown Si nanowires is investigated. Taking advantage of the characteristics of atom probe tomography, we have developed a sample preparation method by inclining the sample at certain angle to characterize the nanowire sidewall without using focused ion beam. With three-dimensional atomic scale reconstruction, we provide direct evidence of Au clusters tending to remain on the nanowire sidewall rather than being incorporated into the Si nanowires. Based on the composition measurement of Au clusters (28% ± 1%), we have demonstrated the supersaturation of Si atoms in Au clusters, which supports the hypothesis that Au clusters are formed simultaneously during nanowire growth rather than during the cooling process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Urinary Virome Perturbations in Kidney Transplantation

The human microbiome is important for health and plays a role in essential metabolic functions and protection from certain pathogens. Conversely, dysbiosis of the microbiome is seen in the context of various diseases. Recent studies have highlighted that a complex microbial community containing hundreds of bacteria colonizes the healthy urinary tract, but little is known about the human urinary viruses in health and disease. To evaluate the human urinary virome in the context of kidney transplantation (tx), variations in the composition of the urinary virome were evaluated in urine samples from normal healthy volunteers as well as patients with kidney disease after they had undergone kidney tx. Liquid chromatography-mass spectrometry/mass spectrometry analysis was undertaken on a selected cohort of 142 kidney tx patients and normal healthy controls, from a larger biobank of 770 kidney biopsy matched urine samples. The cohort of kidney tx patients had biopsy confirmed phenotype classification, coincident with the urine sample analyzed, of stable grafts (STA), acute rejection (AR), BK virus nephritis (BKVN) and chronic allograft nephropathy (CAN). 37 unique viruses were identified across all samples. Some viruses can co-exist as commensals in healthy patients and the virome composition alters with IS exposure and kidney injury. 29 viruses have not been previously described in any human studies, and may originate from environmental exposure of pesticides and intake of non-organic human diets.

Sigdel, Tara K.↗