Search NASASearch

SEARCH · Search NASA

Results for “National Aeronautics and Space Administration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,540 records · Page 59

A computerized aircraft battery servicing facility

The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.

Glover, Richard D.

Integrated Computational Materials Engineering (ICME) Capability Maturity Levels for Ecosystems Enabling Digital Transformation

Digital engineering (DE) and integrated computational materials engineering (ICME) are widely recognized as critical enablers of faster, more affordable, and more reliable aerospace systems. However, many organizations have struggled to realize the promised return on investment (ROI) from digital initiatives. A primary reason is the absence of a shared, decision-focused framework that distinguishes simple digitization of existing workflows from true digital transformation that fundamentally changes how engineering decisions are made. This paper introduces an ICME capability maturity framework that fills this gap. The framework defines six cumulative ICME capability maturity levels (CMLs), explicitly tied to decision authority, engineering integration, optimization, and uncertainty management across material, process, structure, and performance scales. It is designed to complement established readiness metrics such as technology readiness levels (TRLs), manufacturing readiness levels (MRLs), and integration readiness levels (IRLs), by addressing a missing dimension: the conditions required for model-informed decision authority across scales. A unifying figure and capability table illustrate the six-level ICME Capability Maturity Framework, showing how organizations progress from digitization—with limited or negative ROI—to true digital transformation, where ICME-enabled workflows deliver measurable improvements in decision quality, cycle time, risk reduction, and reuse. The framework is intended for both technical practitioners and executive leadership, providing a common language to assess current state, guide roadmaps, align software ecosystem investments, and set realistic expectations for digital transformation outcomes. A regulatory-relevant statement clarifying the relationship between ICME capability and existing certification frameworks is provided.

ICME

Bipolar lead acid battery development

A modular bipolar battery configuration is under development at Johnson Control, Inc. (JCI) and the Jet Propulsion Laboratory (JPL). The battery design, incorporating proven lead acid electrochemistry, yields a rechargeable, high-power source that is light weight and compact. This configuration offers advantages in power capability, weight, and volume over conventional monopolar batteries and other battery chemistries. The lead acid bipolar battery operates in a sealed, maintenance-free mode allowing for maximum application flexibility. It is ideal for high-voltage and high-power applications.

Eskra, Michael

NASA Talks: Harsh Lunar Environments

NASA Talks - Exploration drives technology, and as NASA works toward sustained operations on the lunar surface for a permanent moonbase, it is critical to understand how the location drives what’s needed to accomplish these goals. This is especially important as we land on the lunar South Pole, which will be different and riskier than the previous Apollo landing sites. The thermal conditions will be much colder, the lighting environment is challenged with low sun angles, the regolith holds a charge in the plasma sheath, and the radiation is significantly higher than in low Earth orbit (LEO). Stephanie Sipila, Deputy Manager of Extravehicular Activity and Human Surface Mobility Program (EHP) Technology, Integration and Partnerships Office, provided knowledge and insight into the game-changing technologies NASA is exploring to mitigate these risks.

Stephanie Sipila

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

Computation of three-dimensional mixed convective boundary layer flow

The paper presents the numerical solution of heat and mass transfer during cross-flow (orthogonal) mixed convection. In this class of flow, a buoyancy-driven transport in the vertical direction and a forced convective flow in the horizontal direction results in a three-dimensional boundary layer structure adjacent to the plate. The rates of heat and mass transfer are determined by a combined influence of the two transport processes. The equations for the conservation of mass, momentum, energy, and species concentration were solved along with appropriate boundary conditions to determine the distributions of velocity components, temperature, and concentration across the thickness of the boundary layer at different locations on the plate. Results were expressed in dimensionless form using Reynolds number, Richardson number for heat transfer, Richardson number for mass transfer, Prandtl number, and Schmidt number as parameters. It was found that the transport is dominated by buoyancy at smaller vertical locations and at larger distances away from the forced convection leading edge. Effects of forced convection appeared to be very strong at smaller horizontal distances from the leading edge. The cross stream forced convection enhanced the rate of heat and mass transfer by a very significant amount.

Prashandt Gadepalli

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft

General Electric 20-ampere hour nickel-cadmium battery

The interaction, effect, and controllability of the performance parameters of the General Electric 20-ampere-hour, 24-cell nickel cadmium battery are investigated. The battery was cycled under simulated orbit conditions. The acquired data was analyzed and evaluated in terms of battery parameters and performance characteristics. Conclusions and tests results are presented along with recommendations for further study.

Kirsch, W. W.

Guidelines for Schlieren Systems at Langley Research Center

The original Langley Working Paper (LWP 448) published on July 27th, 1967, provided guidance to NASA Langley Research Center personnel on how to set up conventional path-integrated schlieren flow visualization systems and what pitfalls could be expected with such setups. The guidance and information contained in the document continues to be used for schlieren setups at NASA Langley Research Center to this day. The most commonly used method of flow visualization in supersonic wind tunnels is the schlieren method, or method of striae. At the Langley Research Center, this method is so commonly used that it has come to be regarded somewhat as merely another piece of instrumentation which is to be maintained by service people, and which is too mysteriously complicated to be touched by tunnel personnel. This should not be the case. High-quality results from a schlieren system can only be obtained by having personnel on the tunnel staff who are well-informed on the subject and who have the time and the interest to do a good job of adjustment. This paper is a discussion in practical terms, of some of the points to be considered and the pitfalls that may be encountered in designing, setting up and using a working schlieren system. It is directed specifically toward helping specify and install a Z-type mirror system. It is hoped that the material will be of assistance to facilities throughout the Center and NASA and that users of the schlieren method will be inspired to the point of training people in the adjustment of the systems in use at their facilities.

Langley Working Papers

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Optical properties of morphologically complex black carbon aerosols: Effects of coatings

Optical properties are computed for fractal-like aggregate black carbon (BC) aerosols coated with different substances. Two models are used for these aerosols: (i) the coated aggregate model (model I), where coating is added to the voids and surroundings of BC fractal-like aggregates; and (ii) the closed-cell aggregate model (model II), where coating is added concentrically to each monomer of BC fractal-like aggregates. Our results favor choosing the coated aggregate model (model I) to simulate scattering and absorption by coated BC aerosols because this model is morphologically more realistic, and because this model yields mass absorption cross section (MAC) and backscattering linear depolarization ratio (LDR) values that are consistent with field measurements. Moreover the corresponding computed degree of linear polarization (DoLP) and LDR values are very sensitive to changes in the coating volume fraction (fvol) and the coating refractive index (m). With the same absorbing BC core, the MAC value increases steadily with increasing fvol and m values. For example, using a density of 1.8 g/cm 3 and BC refractive index 1.95 + i0.79, the calculated MAC values for uncoated BC aggregates range from 6.2 to 6.8 m 2 /g at 0.55 µm. When coating material is applied to the BC aggregates, the calculated MAC values for model I particles increase to between 9.8 and 13.2 m 2 /g (depending on m) when fvol = 87.5%. The backscattering LDR values also tend to increase with the increasing m values for the shapes and sizes considered in our study. For model I particles, the backscattering LDR values span a wide range of 4.2–27.8% at a wavelength of 0.35 µm at fvol = 87.5% when m increases from 1.33 to 1.55. Our results are relevant to analyses of polarimetric and lidar observations of smoke particles, especially when these particles undergo hygroscopic growth.

Black carbon aerosols

Thermal Design

An essential phase of the Explorer XIII development was a thermal study and design to provide an acceptable temperature environment for the electronics components and external surfaces of the satellite during ascent and in orbit. It was necessary to establish by preflight analysis and tests that tolerable temperatures could be maintained in three regimes of flight. In the first regime (from launch until release of the heat shield) the satellite was subjected to radiative and conductive heat from the shield. In the second regime, after release of the shield at 350,000 feet, the satellite was heated by free molecular flow. In the third regime - the orbit phase - it was necessary that temperatures within limits for a 1-year lifetime be established. In addition to these three regimes, a study was made to investigate the effect of elevated rocket-motor temperatures during launch and after burnout. This chapter will deal with some pertinent preflight estimates and correlation of these estimates with flight data.

Explorer XIII Satellite

South Asian Monsoon Response to Regional Aerosol Emission Reductions: Insights From RAMIP

Anthropogenic aerosol and associated precursor gas emissions are already declining in many regions and are likely to decline significantly by 2050, with major implications for regional climate. Unlike greenhouse gases, aerosol impacts are spatially heterogeneous and can influence climate both near emission sources and through remote teleconnections. This is particularly important for the South Asian monsoon system, where both local and remote aerosol changes can significantly affect precipitation patterns. Using simulations from the Regional Aerosol Model Intercomparison Project, we examine how local and remote aerosol emission reductions influence South Asian climate across both pre-monsoon and monsoon seasons, including weakening of the elevated heat pump (EHP) mechanism during pre-monsoon months. Our analysis employs 10-member ensembles from 10 CMIP6-era models to compare three experiments with global, South Asian, and East Asian aerosol reductions relative to a high-emission baseline (SSP3-7.0). This experimental design allows us to isolate and quantify the distinct impacts of regional emission changes. Results reveal that global aerosol reductions produce a larger all-India precipitation increase (+0.28 mm day −1 ) than South Asian reductions alone (+0.19 mm day −1 ), with the strongest regional responses over the northern Bay of Bengal, the Western Ghats and Indo-Gangetic Plains. East Asian reductions show uncertain but modest precipitation reductions of 0.2-0.6 mm day −1 over parts of west-central and eastern Indian regions. Pre-monsoon carbonaceous aerosol reductions systematically weaken the EHP, cooling the mid-troposphere over the Himalayan foothills by up to 0.4 K and producing localised anomalous descent that opposes the climatological pre-monsoon ascent. Substantial inter-model diversity exists in the spatial patterns and magnitudes of these responses, highlighting key uncertainties in aerosol–monsoon interactions. The South Asian precipitation response is driven by enhanced land–sea thermal contrast, while the pre-monsoon EHP weakening is attributable exclusively to local South Asian carbonaceous aerosol forcing rather than remote teleconnections. These findings have direct implications for air quality and climate adaptation planning across South Asia as regional aerosol emissions diverge under different development pathways.

cmip6