Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIXELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical estimation of photon reabsorption process and optical crosstalk in arrays of HgCdTe photodiodes

The effect of photon reabsorption (recycling) on photoelectric parameters of non-equilibrium P{sup +}nN{sup +} photodiodes, for example the pixels of the detector array, was analyzed. We solved the system of transport equations additionally extended by two balances equations for photons. It was shown that the density of photons in photodiodes is strongly dependent on the concentration of charge carriers. This phenomenon results in a drastic reduction in the rate of radiative recombination and generation in analyzed photodiodes. Additionally, the phenomenon of optical crosstalk between the nearest pixels in the matrix was examined. The increase in the dark current caused by this phenomenon was estimated. It depends on the size of the pixel, the distance between pixels, and the value of bias voltage. The increase in the current is around 0.5% for a pixel with surface 10 × 10 µm{sup 2}, and around 1% for one with 5 × 5 µm{sup 2}, both reverse biased with 0.2 V.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subfield crop yields and temporal stability in thousands of US Midwest fields

Understanding subfield crop yields and temporal stability is critical to better manage crops. Several algorithms have proposed to study within-field temporal variability but they were mostly limited to few fields. In this study, a large dataset composed of 5520 yield maps from 768 fields provided by farmers was used to investigate the influence of subfield yield distribution skewness on temporal variability. The data are used to test two intuitive algorithms for mapping stability: one based on standard deviation and the second based on pixel ranking and percentiles. The analysis of yield monitor data indicates that yield distribution is asymmetric, and it tends to be negatively skewed (p < 0.05) for all of the four crops analyzed, meaning that low yielding areas are lower in frequency but cover a larger range of low values. The mean yield difference between the pixels classified as high-and-stable and the pixels classified as low-and-stable was 1.04 Mg ha –1 for maize, 0.39 Mg ha –1 for cotton, 0.34 Mg ha –1 for soybean, and 0.59 Mg ha —1 for wheat. The yield of the unstable zones was similar to the pixels classified as low-and-stable by the standard deviation algorithm, whereas the two-way outlier algorithm did not exhibit this bias. Furthermore, the increase in the number years of yield maps available induced a modest but significant increase in the certainty of stability classifications, and the proportion of unstable pixels increased with the precipitation heterogeneity between the years comprising the yield maps.

59 BASIC BIOLOGICAL SCIENCES↗

Lateral Diffusion Estimation in Fully Depleted Thick CCD Using Flat Field Image Analysis

In thick fully depleted CCDs charge carrier transport from the back window to the gates is accompanied by charge diffusion. Lateral diffusion smooths out density variations of the incoming photon flux by redistributing charges spatially. This creates short range positive correlations in recorded amplitudes. Pixel-to-pixel amplitude variations can also be caused by pixel size and quantum efficiency variations. Pixel size variations result in short range negative correlations. Our study shows that the characteristic diffusion width can be extracted from flat field data. The study was performed on fully depleted, thick CCDs produced in a technology study for the Large Synoptic Survey Telescope (LSST). Data were taken in the laboratory at bias voltages between -5 and -40 V. To increase statistical accuracy, images taken in identical conditions were co-added after base line subtraction and master files were produced. A flat field image simulator was developed for statistical comparison of simulated and measured images. Results on diffusion, pixel response variations, data features, analysis and modeling techniques are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Analysis of the EMCCD point-source response using x-rays

Electron Multiplying Charge Coupled Devices, EMCCD are used as x-ray detectors. The NSLS-II Soft Inelastic x-ray Scattering (SIX) beam line has two EMCCDs for x-ray detection in the spectrometer arm. The spectrometer with high resolving power disperses x-rays vertically. The x-ray vertical position on the sensor plane is related to its energy. This allows for very accurate x-ray energy measurements through x-ray coordinates. X-rays interact with silicon and create a number of electron-hole pairs proportional to the x-ray energy. Electrons drift and diffuse toward pixel gates and are collected there. The diffused electrons form a charge cloud distributed over several neighboring pixels. This charge sharing enables coordinate measurements with accuracy better than the pixel pitch. The charge distribution shape has to be taken into account to achieve ultimate accuracy in coordinate measurements. In this paper, we present a method of the charge distribution shape analysis and demonstrate its applications. The drift and diffusion of electrons ftom the point of generation to pixel gates results in the bell-shaped electron cloud usually approximated by Gaussian shape. The number of electrons collected under a pixel is proportional to the shape function integral. These electron packets get transferred to the sense node of the output amplifier. The transfer process could introduce distortions to the original charge distribution. For example, during transfers, electrons in the packet could be exposed to traps if they are present in the sensor. The trapping and later the release processes distort the apparent shape of the charge distribution. Therefore, deviations of the charge distribution shape ftom the originally symmetrical form can indicate the presence of trap centers in the sensor and can be used for sensor diagnostics.

47 OTHER INSTRUMENTATION↗

Compressive Classification for TEM-EELS

Acquiring atomic-resolution images of beam sensitive materials or under dynamic conditions (e.g. operando STEM) is very difficult and requires precise dose fractioning to minimize the dose delivered to the sample and acquire the data more rapidly than dynamics present. Typical methods of low-dose STEM imaging include adjusting the beam current, dwell-time, and probe Scanning transmission electron microscopy (STEM) is used routinely to obtain atomic-resolution images of a small selection of radiation tolerant materials under stable conditions.size. All three of these determine the dose over a spatial area in STEM. Recently, compressive sensing [1] has been applied to electron microscopy. The computational imaging method of inpainting [2] has been proposed as a method to reduce dose and increase acquisition speed for STEM. Inpainting is a technique to recover missing pixels in an image. By skipping pixels (randomly) during acquisition, a fourth dose-control mechanism is realized [3]. A few implementations of randomly-subsampled STEM exist (e.g., [4]). To make the concepts of compressive sensing accessible to the microscopy community we begin with an example using atomic resolution images of a GaAs crystal (see Figure 1). Because the crystal is periodic it has a sparse representation in reciprocal space. In fact, a sparse representation is a key component of compressive sensing. If an image is sub-sampled randomly we find that the Fourier transform remains sparse, but becomes increasing noisy as less and less data is acquired. Yet, by finding the peaks in the reciprocal image and removing the noise it is possible to recover atomic resolution images with only 1% of the pixels. Figure 1 shows the reconstruction process for GaAs sub-sampled at 50%, 10%, 5%, and 1%. Periodic images form a special class for which the optimal sampling approach (according to CS theory) is a random selection of pixels. For non-periodic images, such as those arising in in-situ STEM, methods such as dictionary learning are necessary [2,5]. The data can be compressed in time for TEM [5] or pixels can be skipped randomly for STEM. There are several issues that arise in developing a random scan for STEM [4] and a coded aperture for TEM. The remainder of the talk will address these issues. References: [1] E Candes and M Wakin. Signal Processing Magazine, IEEE. 2(25) (2008), pp. 21. [2] A Stevens, Pu Y, Sun Y, et al. Artificial Intelligence & Statistics (AISTATS), 2017. [3] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [4] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016). [5] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [6] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Hao, Weituo↗

Calibration and Characterization of Single Photon Counting Cameras for Short-Pulse Laser Experiments

The photon counting efficiency of various CCD based cameras was studied as a function of x-ray energy and exposure. A pair of Spectral Instruments Model 800 CCD cameras fitted with 16 {micro}m thick back-illuminated CCDs were calibrated at low x-ray energy using two well established histogram methods, a standard pixel for pixel histogram and the single pixel event histogram method. In addition, two new thick substrate CCDs were evaluated for use at high energy. One was a commercially available Princeton Instruments LCX1300 deep depletion CCD camera while the other was a custom designed 650 {micro}m thick partially depleted CCD fitted to a SI 800 camera body. It is shown that at high x-ray energy, only a pixel-summing algorithm was able to derive spectral data due to the spreading of x-ray events over many pixels in the thicker substrate CCDs. This paper will describe the different algorithms used to extract spectra and the absolute detection efficiencies using these algorithms. These detectors will be very useful to detect high-energy x-ray photons from high-intensity short pulse laser interactions.

42 ENGINEERING↗

A spatial light modulator for terahertz beams

Spatial light modulators that control the spatial transmission of a terahertz beam either electrically or optically, have been difficult to build due to the lack of suitable materials. Here we propose the use of active terahertz metamaterials for the construction of a multi-pixel spatial modulator for terahertz beams. Our first-generation device consists of a 4 x 4 pixel array, where each pixel is an array of sub-wavelength-sized split-ring resonator elements fabricated on a semiconductor substrate, and is independently controlled by applying an external voltage. Through terahertz transmission experiments, we show that the spatial modulator has a uniform modulation depth of around 40 percent across all pixels at the resonant frequency. Around this operating frequency, the crosstalk between pixels is negligible. This device can operate under small voltage levels, at room temperature, with low power consumption and reasonably high switching speed, and can therefore benefit future applications in terahertz imaging and communications.

36 MATERIALS SCIENCE↗

Nano-optical observation of cascade switching in a parallel superconducting nanowire single photon detector

The device physics of parallel-wire superconducting nanowire single photon detectors is based on a cascade process. Using nano-optical techniques and a parallel wire device with spatially separate pixels, we explicitly demonstrate the single- and multi-photon triggering regimes. We develop a model for describing efficiency of a detector operating in the arm-trigger regime. We investigate the timing response of the detector when illuminating a single pixel and two pixels. We see a change in the active area of the detector between the two regimes and find the two-pixel trigger regime to have a faster timing response than the one-pixel regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fluctuation spectroscopy: a new probe of old stellar populations

We introduce a new method to determine the relative contributions of different types of stars to the integrated light of nearby early-type galaxies. As is well known, the surface brightness of these galaxies shows pixel-to-pixel fluctuations due to Poisson variations in the number of giant stars. Differential spectroscopy of pixels as a function of fluctuation strength ({sup f}luctuation spectroscopy{sup )} effectively measures the spectral variation of stars as a function of their luminosity, information that is otherwise difficult to obtain for individual stars outside of the Local Group. We apply this technique to the elliptical galaxy NGC 4472, using Hubble Space Telescope/Advanced Camera for Surveys imaging in six narrow-band ramp filters tuned to spectral features in the range 0.8 μm-1.0 μm. Pixels with ±5% broad-band variations show differential color variations of 0.1%-1.0% in the narrow-band filters. These variations are primarily due to the systematic increase in TiO absorption strength with increasing luminosity on the upper giant branch. The data are very well reproduced by the same Conroy and van Dokkum stellar population synthesis model that is the best fit to the integrated light, with residuals in the range 0.03%-0.09%. Models with ages or metallicities that are significantly different from the integrated-light values do not yield good fits. We can also rule out several modifications to the underlying model, including the presence of a significant (>3% of the light) population of late M giants. The current observations constitute a powerful test of the expected luminosities and temperatures of metal-rich giants in massive early-type galaxies. Studies of pixels with much larger (negative) fluctuations will provide unique information on main sequence stars and the stellar initial mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

On the regularity of the covariance matrix of a discretized scalar field on the sphere

We present a comprehensive study of the regularity of the covariance matrix of a discretized field on the sphere. In a particular situation, the rank of the matrix depends on the number of pixels, the number of spherical harmonics, the symmetries of the pixelization scheme and the presence of a mask. Taking into account the above mentioned components, we provide analytical expressions that constrain the rank of the matrix. They are obtained by expanding the determinant of the covariance matrix as a sum of determinants of matrices made up of spherical harmonics. We investigate these constraints for five different pixelizations that have been used in the context of Cosmic Microwave Background (CMB) data analysis: Cube, Icosahedron, Igloo, GLESP and HEALPix, finding that, at least in the considered cases, the HEALPix pixelization tends to provide a covariance matrix with a rank closer to the maximum expected theoretical value than the other pixelizations. The effect of the propagation of numerical errors in the regularity of the covariance matrix is also studied for different computational precisions, as well as the effect of adding a certain level of noise in order to regularize the matrix. In addition, we investigate the application of the previous results to a particular example that requires the inversion of the covariance matrix: the estimation of the CMB temperature power spectrum through the Quadratic Maximum Likelihood algorithm. Finally, some general considerations in order to achieve a regular covariance matrix are also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-ray Spectrometer

The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.

79 ASTRONOMY AND ASTROPHYSICS↗

A method based on moving least squares for XRII image distortion correction

This paper presents a novel integrated method to correct geometric distortions of XRII (x-ray image intensifier) images. The method has been compared, in terms of mean-squared residual error measured at control and intermediate points, with two traditional local methods and a traditional global methods. The proposed method is based on the methods of moving least squares (MLS) and polynomial fitting. Extensive experiments were performed on simulated and real XRII images. In simulation, the effect of pincushion distortion, sigmoidal distortion, local distortion, noise, and the number of control points was tested. The traditional local methods were sensitive to pincushion and sigmoidal distortion. The traditional global method was only sensitive to sigmoidal distortion. The proposed method was found neither sensitive to pincushion distortion nor sensitive to sigmoidal distortion. The sensitivity of the proposed method to local distortion was lower than or comparable with that of the traditional global method. The sensitivity of the proposed method to noise was higher than that of all three traditional methods. Nevertheless, provided the standard deviation of noise was not greater than 0.1 pixels, accuracy of the proposed method is still higher than the traditional methods. The sensitivity of the proposed method to the number of control points was greatly lower than that of the traditional methods. Provided that a proper cutoff radius is chosen, accuracy of the proposed method is higher than that of the traditional methods. Experiments on real images, carried out by using a 9 in. XRII, showed that residual error of the proposed method (0.2544{+-}0.2479 pixels) is lower than that of the traditional global method (0.4223{+-}0.3879 pixels) and local methods (0.4555{+-}0.3518 pixels and 0.3696{+-}0.4019 pixels, respectively)

62 RADIOLOGY AND NUCLEAR MEDICINE↗