Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

VisIO: enabling interactive visualization of ultra-scale, time-series data via high-bandwidth distributed I/O systems

Petascale simulations compute at resolutions ranging into billions of cells and write terabytes of data for visualization and analysis. Interactive visuaUzation of this time series is a desired step before starting a new run. The I/O subsystem and associated network often are a significant impediment to interactive visualization of time-varying data; as they are not configured or provisioned to provide necessary I/O read rates. In this paper, we propose a new I/O library for visualization applications: VisIO. Visualization applications commonly use N-to-N reads within their parallel enabled readers which provides an incentive for a shared-nothing approach to I/O, similar to other data-intensive approaches such as Hadoop. However, unlike other data-intensive applications, visualization requires: (1) interactive performance for large data volumes, (2) compatibility with MPI and POSIX file system semantics for compatibility with existing infrastructure, and (3) use of existing file formats and their stipulated data partitioning rules. VisIO, provides a mechanism for using a non-POSIX distributed file system to provide linear scaling of 110 bandwidth. In addition, we introduce a novel scheduling algorithm that helps to co-locate visualization processes on nodes with the requested data. Testing using VisIO integrated into Para View was conducted using the Hadoop Distributed File System (HDFS) on TACC's Longhorn cluster. A representative dataset, VPIC, across 128 nodes showed a 64.4% read performance improvement compared to the provided Lustre installation. Also tested, was a dataset representing a global ocean salinity simulation that showed a 51.4% improvement in read performance over Lustre when using our VisIO system. VisIO, provides powerful high-performance I/O services to visualization applications, allowing for interactive performance with ultra-scale, time-series data.

97 MATHEMATICS AND COMPUTING↗

Enhancing Header Shape Through Computational Fluid Dynamics for Improved Performance

Shape optimization in power plant design is crucial for maximizing efficiency and minimizing energy losses It impacts performance, cost effectiveness, and environmental sustainability Our project focuses on optimizing header pipe geometry using a method that considers temperature, flow, and pressure distributions, along with structural analysis This approach ensures structural integrity while minimizing material costs

20 FOSSIL-FUELED POWER PLANTS↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel approach to RF power coupling in Radio-Frequency Quadrupole (RFQ) structures: built-in coaxial double-loop coupling port

Efficient and reliable RF power couplers in accelerating cavities require precise impedance matching and mechanical stability to ensure optimal beam energy transfer. In radio-frequency quadrupole (RFQ) accelerators, power is commonly delivered using waveguide iris or coaxial loop couplers. Iris couplers can handle high RF power but lack tunability, while coaxial loop couplers offer tuning flexibility but are limited in power handling and thermal performance. We propose a new RFQ power coupling concept utilizing a single input coaxial center-fed double-loop antenna built into a vane in an RFQ structure . The design integrates back-to-back loops into the RFQ vanes, fed by a TEM coaxial transmission line with standard 50-Ω characteristic impedance. The configuration can allow straightforward and easy ceramic window replacement without retuning, and coupling strength is adjusted with protruding tuning rods. Numerical simulations, performed with both a simplified RFQ model and the Spallation Neutron Source RFQ, demonstrate improved RF performance and reduced dipole mode excitation. The results establish the coaxial double-loop coupler as a practical alternative for high-power RFQ coupling applications.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Dynamic Characterization and Performance Evaluation of a 10-kw Power Take-Off with Mechanical Motion Rectifier for Wave Energy Conversion

The power take-off (PTO) is a key component for wave energy converters (WECs). The dynamic properties of the PTO influence the response of the WEC and should be considered when designing the WEC and not oversimplified. In addition, the efficiency as well as the reliability can play an important role on whether the PTO can be suitable for real-world applications. In this paper, a novel compact PTO rated at 10 kW is designed and prototyped, and a comprehensive nonlinear dynamic model is established for the PTO. Through bench testing, the unknown parameters of the dynamic model are characterized and determined. Further verification shows that the model can predict the dynamic performance of the PTO well. In addition, the test results show that the mechanical motion rectifier PTO can achieve good energy transfer efficiency, especially for low-load and low-speed conditions.

bench test↗

Scaling magnetized liner inertial fusion on Z and future pulsed-power accelerators

The MagLIF (Magnetized Liner Inertial Fusion) concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] has demonstrated fusion–relevant plasma conditions [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z accelerator with a peak drive current of about 18 MA. We present 2D numerical simulations of the scaling of MagLIF on Z as a function of drive current, preheat energy, and applied magnetic field. The results indicate that deuterium-tritium (DT) fusion yields greater than 100 kJ could be possible on Z when all of these parameters are at the optimum values: i.e., peak current = 25 MA, deposited preheat energy = 5 kJ, and B{sub z} = 30 T. Much higher yields have been predicted [S. A. Slutz and R. A. Vesey, Phys. Rev. Lett. 108, 025003 (2012)] for MagLIF driven with larger peak currents. Two high performance pulsed-power accelerators (Z300 and Z800) based on linear-transformer-driver technology have been designed [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The Z300 design would provide 48 MA to a MagLIF load, while Z800 would provide 65 MA. Parameterized Thevenin-equivalent circuits were used to drive a series of 1D and 2D numerical MagLIF simulations with currents ranging from what Z can deliver now to what could be achieved by these conceptual future pulsed-power accelerators. 2D simulations of simple MagLIF targets containing just gaseous DT have yields of 18 MJ for Z300 and 440 MJ for Z800. The 2D simulated yield for Z800 is increased to 7 GJ by adding a layer of frozen DT ice to the inside of the liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics—Near-Real-Time Cyber-Physical Resiliency Through Machine Learning

The Situational Awareness of Grid Anomalies (SAGA) project built upon foundational power system tools developed at the National Renewable Energy Laboratory (NREL) integrated with an ever-increasing set of Gridmetrics data extracted from the cable television (CATV) broadband network infrastructure while assimilating other time-series geospatial data and information, such as weather and cyber-physical phenomena, to demonstrate a disruptive technology for power system data analytics relying on existing infrastructure. Three research thrusts supported (1) visual analytics, (2) cyber-physical power system simulation, and (3) anomaly detection. SAGA created technology that leverages, couples, and fortifies two vastly different realms - power and broadband - to increase the resiliency of the power grid in the face of increasing cyberattacks and operational challenges related to integrating DERs. The exploration of potential synergies of broadband-enabled grids resulted in identifying a mutually beneficial symbiosis that can increase the resiliency of both power and broadband services. Broadband networks perform better with reliable power and are good at providing real-time measurements that identify where the grid is under attack, is failing, or is weak. Likewise, sensor-starved distribution grids perform better and can be more reliable when their operation is buttressed with observations of broadband-detected anomalies. Future research can explore broadband's contribution to continuing to improve grid resiliency, reliability, and cost-effective operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Testing of an Integrated Magnetic Power Take-Off

A wave energy converter (WEC) and the power take-off (PTO) generator system can be represented by using a mass-spring-dampener model. By incorporating a negative stiffness spring within the PTO, the overall stiffness of the PTO can be lowered allowing the impedance of the PTO to be more closely matched with the WEC. By designing for impedance matching the WEC can greatly enhance its power generation capability. This project has involved the design, fabrication and testing of a new type of linear-stroke length and rotary stroke length adjustable negative stiffness magnetic springs for use within a wave energy converter (WEC). The magnetic springs were studied by using 3-D finite element analysis with the objective of creating high energy density and a long linear stroke length. After the construction and testing of both a proof-of-principle adjustable linear and rotary magnetic spring prototype the rotary (torsional) magnetic spring was selected for scaling up analysis. The selected scaled-up proof-of-principle magnetic spring had a peak torque of 850 Nm with a ±45 degree stroke length. By translating the inner rotor relative to the outer rotor, the stiffness could be adjusted to be either negative or positive stiffness. During this project a magnetic lead screw was also studied, and it was shown that by combining the magnetic lead screw with a linearly translating magnetic spring a very long rotary stroke length could be attained. However, as the magnetic lead screw increased complexity and reduced overall energy density relative to a rotary (torsional) spring, this design approach was not further pursed. Dynamometer testing of the variable stiffness magnetic springs was first completed by Portland State University and following this the magnetic spring performance was independently verified by Sandia National Laboratory (Sandia). A WEC analysis when using a variable stiffness magnetic spring was completed by using the WecOptTool. WecOptTool is an open-source WEC optimization software developed by Sandia that supports efficient power take-off (PTO) and control optimization. Wave condition data from the Oregon PacWave test-site was used in this study. The analysis showed that a WEC with a tunable stiffness value could consistently achieve about 80% of its maximum theoretical power production. The use of a tunable stiffness WEC, rather than zero-stiffness or a constant stiffness WEC was also shown to lead to a smaller maximum PTO force requirement. The variable stiffness magnetic spring was integrated into an experimental WEC developed by Sandia, called a Wave-Bot. Sandia successfully completed water-tank testing of the Wave-Bot at the Navy’s Carderock, Maryland, wave-basin test site. The wave-basin testing helped to experimentally demonstrate the operating capabilities and increased power generation capability of a WEC containing an integrated variable stiffness magnetic spring. A WEC capacity factor analysis was also completed. The capacity factor was defined as the ratio of annual average WEC generator power to the maximum (RMS) generated power. This capacity factor provided a means of identifying the ratio of potential revenue to cost. It was calculated that if a tunable variable stiffness magnetic spring has RMS constraints it could operate with a capacity factor above 30%. This is comparable to a wind turbine’s capacity factor.

16 TIDAL AND WAVE POWER↗

A Double-side Cooled SiC MOSFET Power Module with Sintered-silver Interposers: I. Design, Simulation, Fabrication, and Performance Characterization

Planar, double-side cooled power modules are emerging in electric-drive inverters because of their low profile, better heat extraction, and lower package parasitic inductances. However, there is still concern about their reliability due to the rigid interconnection between the device chips and two substrates of the power module. In this paper, a porous interposer made of low-temperature sintered silver is introduced to reduce the thermo-mechanical stresses in the module. A double-side cooled half-bridge module consisting of two 1200 V, 149 A SiC MOSFETs was designed, fabricated, and characterized. By using the sintered-Ag instead of solid copper interposers, our simulation results showed that at a total power loss of 200 W, the thermo-mechanical stress at the most vulnerable interfaces (interposer-attach layer) was reduced by 42 % and in the SiC MOSFET by 50 % with a trade-off of only 3.6 % increase in junction temperature. The sintered-Ag interposers were readily fabricated into desired dimensions without post-machining and did not require any surface finishing for die-bonding and substrate interconnection by silver sintering. Here, the porous interposers were also deformable under a low force or pressure, which helped to accommodate chip thickness and/or substrate-to-substrate gap variations in the planar module structure, thus simplifying module fabrication. Experimental results on the electrical performance of the fabricated SiC modules validated the success of using the porous silver interposers for fabricating planar, double-side cooled power modules.

42 ENGINEERING↗

Preliminary Cost and Performance Results for a Natural Gas-Fired Direct sCO2 Power Plant

<p class="cs5F0F80D8"><span>This study reports on a cost and performance baseline developed at NETL for a natural gas-fueled direct sCO2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS).&nbsp; The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train.&nbsp; Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE).&nbsp; Performance results yield a baseline sCO2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture).&nbsp; Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty.&nbsp; Finally, the effects of incomplete combustion on the overall plant performance are assessed.</span>

White, Chuck↗

Preliminary Cost and Performance Results for a Natural Gas-Fired Direct sCO2 Power Plant

<span>This study reports on a cost and performance baseline developed at NETL for a natural gas-fueled direct sCO2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS).&nbsp; The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train.&nbsp; Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE).&nbsp; Performance results yield a baseline sCO2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture).&nbsp; Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty.&nbsp; Finally, the effects of incomplete combustion on the overall plant performance are assessed.</span>

Weiland, Nathan↗

Frontier Job-Centric Telemetry Dataset

Comprehensive analysis of high-performance computing (HPC) systems requires linking workload execution to system behavior. This kind of analysis is vital for diagnosing performance issues, managing capacity, detecting anomalous workloads, and understanding how applications interact with system hardware. This job-centric telemetry dataset unifies scheduler job records with node-level measurements, enabling direct association between workloads and their corresponding power, thermal, and performance characteristics. It contains sanitized, scheduler related metadata for 152,400 individual jobs that ran on the Frontier supercomputer and ended on selected days throughout 2024 and 2025, a subpopulation of ~6.8% of the total number of allocated jobs with non-zero run time on the system over that same period. Each is linked with files that contain telemetry time series records of the power utilization and temperature behavior of its allocated nodes and their processors during the run time of the job. Where available, a portion of the job files also contain network performance time series. Jobs are sampled from select days that reflect normal levels of user activity and possess job size distributions with large numbers of leadership class jobs (>20% of Frontier nodes). Jobs in this dataset attempt to best represent successful user workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results of Laboratory Testing of Advanced Power Strips: Preprint

This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Suprathermal electron transport studies in radio-frequency-heated tokamak plasmas

This contribution reports on the study of suprathermal electron radial transport enhancement in the presence of electron-heating radio-frequency waves, such as electron-cyclotron waves or lower-hybrid waves. Since suprathermal electrons emit hard X-rays from Bremsstrahlung, experimental data from hard X-ray measurements are used to follow their dynamics. In particular, electron-cyclotron power modulation experiments performed in TCV show that this transport depends on the total electron-cyclotron power. These results are corroborated by experimentally constrained Fokker-Planck simulations [J. Cazabonne et al, Plasma Phys. Control. Fusion 65, 104001 (2023)]. Similar experiments have been performed in WEST with lower-hybrid waves, and are reported for the first time. Preliminary analyses show potential evidence of suprathermal electron transport, but no clear dependence on wave power nor photon energy at this stage.

Cazabonne, Jean [CEA, IRFM, Saint Paul Lez Durance↗

Investigating power capping toward energy-efficient scientific applications: Investigating Power Capping toward Energy-Efficient Scientific Applications

The emergence of power efficiency as a primary constraint in processor and system design poses new challenges concerning power and energy awareness for numerical libraries and scientific applications. Power consumption also plays a major role in the design of data centers, which may house petascale or exascale-level computing systems. At these extreme scales, understanding and improving the energy efficiency of numerical libraries and their related applications becomes a crucial part of the successful implementation and operation of the computing system. In this paper, we study and investigate the practice of controlling a compute system's power usage, and we explore how different power caps affect the performance of numerical algorithms with different computational intensities. Further, we determine the impact, in terms of performance and energy usage, that these caps have on a system running scientific applications. This analysis will enable us to characterize the types of algorithms that benefit most from these power management schemes. Our experiments are performed using a set of representative kernels and several popular scientific benchmarks. Lastly, we quantify a number of power and performance measurements and draw observations and conclusions that can be viewed as a roadmap to achieving energy efficiency in the design and execution of scientific algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗