Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Low-light-level integrating video system

System consists of television camera using 25 mm SEC vidicon, low dispersion spectrograph, and digital video image system used for buffer storage of video data during tube readout scanning. Six-bit ADC converts video to digital data which are stored on magnetic tape for future evaluation.

Duncan, B. J.↗

High-Visibility Data Display

Data-monitoring system continuously senses output voltages from transducers and provides large, easy-to-read displays of quantities represented by voltages. Measurements of power-supply voltages and currents, pressures, temperatures, strains, and masses displayed. System intended to operate 24 hours a day, producing uninterrupted readouts of critical parameters.

Slusser, K.↗

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

CRADA: Data Acquisition and Tomographic Software Development

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

97 MATHEMATICS AND COMPUTING↗

Assembly of the Dark Energy Survey CCD Imager

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO.This instrument is a 2.2 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k × 4k CCDs and 12 2k × 2kCCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. DECam includes thevessel shell, the optical window cell, the CCDs with their readout electronics and vacuum interface, the focal planesupport plate and its mounts, and the cooling system and thermal controls. Assembly of the imager, alignment of thefocal plane and installation of the CCDs are described. During DECam development a full scale prototype was used formulti-CCD readout tests. This test vessel went through several stages as the CCDs and related hardware progressedfrom early prototypes to final production designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Science data systems

Digital generation of acceleration voltage for mass spectrometer, and development of low power, nondestructive readout, plated-wire memory

Source record↗

End-to-End Workflow for Machine-Learning-Based Qubit Readout With QICK and hls4ml

In this article, we present an end-to-end workflow for superconducting qubit readout that embeds codesigned neural networks into the quantum instrumentation control kit (QICK). Capitalizing on the custom firmware and software of the QICK platform, which is built on Xilinx radiofrequency system-on-chip field-programmable gate arrays (FPGAs), we aim to leverage machine learning (ML) to address critical challenges in qubit readout accuracy and scalability. The workflow utilizes the hls4ml package and employs quantization-aware training to translate ML models into hardware-efficient FPGA implementations via user-friendly Python application programming interfaces. We experimentally demonstrate the design, optimization, and integration of an ML algorithm for single transmon qubit readout, achieving 96% single-shot fidelity with a latency of 32.25 ns and less than 16% FPGA lookup table resource utilization. Our results offer the community an accessible workflow to advance ML-driven readout and adaptive control in quantum information processing applications.

42 ENGINEERING↗

Progress on the upgrade of the CMS Hadron Calorimeter Front-End electronics

We present a scheme to upgrade the CMS HCAL front-end electronics in the second long shutdown to upgrade the LHC (LS2), which is expected to occur around 2018. The HCAL electronics upgrade is required to handle the major instantaneous luminosity increase (up to 5 * 10{sup 34} cm{sup -2} s{sup -1}) and an expected integrated luminosity of {approx}3000 fb{sup -1}. A key aspect of the HCAL upgrade is to read out longitudinal segmentation information to improve background rejection, energy resolution, and electron isolation at the L1 trigger. This paper focuses on the requirements for the new electronics and on the proposed solutions. The requirements include increased channel count, additional timing capabilities, and additional redundancy. The electronics are required to operate in a harsh environment and are constrained by the existing infrastructure. The proposed solutions span from chip level to system level. They include the development of a new ASIC ADC, the design and testing of higher speed transmitters to handle the increased data volume, the evaluation and use of circuits from other developments, evaluation of commercial FPGAs, better thermal design, and improvements in the overall readout architecture. We will report on the progress of the designs for these upgraded systems, along with performance requirements and initial design studies.

43 PARTICLE ACCELERATORS↗

Electronic systems for the new multichannel spectrometer at Sacramento Peak.

Description of the design features and operation of a new multichannel solar spectrometer to be used for ground-based observations of active regions whose X-ray and EUV emissions are studied by the OSO-H and other satellites. The electronic systems associated with the instrument include (1) an electrooptical guider controlled by a punched paper tape capable of making raster scans of selected portions of the solar disk, (2) a programmer unit that applies paper-tape commands to various portions of the instrument, (3) a closed-loop servosystem for the vacuum heliostat, (4) stepping motor controls for spectral scans, (5) a 40-channel photomultiplier readout, and (6) a magnetometer. Preliminary solar observations indicate satisfactory performance of the system.

Hobbs, R. W.↗

Impedance-matched cavity quantum memory

We consider an atomic frequency comb based quantum memory inside an asymmetric optical cavity. In this configuration it is possible to absorb the input light completely in a system with an effective optical depth of one, provided that the absorption per cavity round trip exactly matches the transmission of the coupling mirror (''impedance matching''). We show that the impedance matching results in a readout efficiency only limited by irreversible atomic dephasing, whose effect can be made very small in systems with large inhomogeneous broadening. Our proposal opens up an attractive route toward quantum memories with close to unit efficiency.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Synchronization of the 14 kTon NO$\nu$A neutrino detector with the Fermilab NuMI beam

The NOνA experiment is a neutrino oscillation experiment designed to measure parameters related to the neutrino mixing matrix, mass hierarchy and CP violation. The experiment measures neutrino and anti-neutrino interactions from the NuMI beam line at Fermilab in a Near Detector and a Far Detector located 810 kilometers away. Making these measurements requires precise synchronization of 344,064 channels in the Far Detector to an absolute wall time with a channel to channel variation of less then 10 ns. The experiment must correlate the presence of the relatively narrow neutrino beam in the detector with data readout. This paper will discuss the performance of the NOνA timing system during the first few months of operation at the Far Detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile telemonitoring system

Small scale versatile multichannel telemonitoring can be installed economically with considerable expansion capabilities. This system contains a data transmitter, control transmitter, control receiver, display of readout units, a sync generator, and some remote control features.

Fergus, R. W.↗

Gas chromatographic column for the storage of sample profiles

The concept of a sample retention column that preserves the true time profile of an analyte of interest is studied. This storage system allows for the detection to be done at convenient times, as opposed to the nearly continuous monitoring that is required by other systems to preserve a sample time profile. The sample storage column is essentially a gas chromatography column, although its use is not the separation of sample components. The functions of the storage column are the selective isolation of the component of interest from the rest of the components present in the sample and the storage of this component as a function of time. Using octane as a test substance, the sample storage system was optimized with respect to such parameters as storage and readout temperature, flow rate through the storage column, column efficiency and storage time. A 3-h sample profile was collected and stored at 30 degrees C for 20 h. The profile was then retrieved, essentially intact, in 5 min at 130 degrees C.

NASA Program Exobiology↗