A Data-Driven Nonparametric Approach for Probabilistic Load-Margin Assessment Considering Wind Power Penetration

A modern power system is characterized by an increasing penetration of wind power, which results in large uncertainties in its states. These uncertainties must be quantified properly; otherwise, the system security may be threatened. Facing this challenge, here we propose a cost-effective, data-driven approach to assessing a power system's load margin probabilistically. Using actual wind data, a kernel density estimator is applied to infer the nonparametric wind speed distributions, which are further merged into the framework of a vine copula. The latter enables us to simulate complex multivariate and highly dependent model inputs with a variety of bivariate copulae that precisely represent the tail dependence in the correlated samples. Furthermore, to reduce the prohibitive computational time of traditional Monte-Carlo simulations that process a large amount of samples, we propose to use a nonparametric, Gaussian-process-emulator-based reduced-order model to replace the original complicated continuation power-flow model through a Bayesian-learning framework. To accelerate the convergence rate of this Bayesian algorithm, a truncated polynomial chaos surrogate, which serves as a highly efficient, parametric Bayesian prior, is developed. This emulator allows us to execute the time-consuming continuation power-flow solver at the sampled values with a negligible computational cost. Results of simulations that are performed on several test systems reveal the impressive performance of the proposed method in the probabilistic load-margin assessment.

17 WIND ENERGY↗

Fully integrated safeguards and security for reprocessing plant monitoring.

Nuclear fuel reprocessing plants contain a wealth of plant monitoring data including material measurements, process monitoring, administrative procedures, and physical protection elements. Future facilities are moving in the direction of highly-integrated plant monitoring systems that make efficient use of the plant data to improve monitoring and reduce costs. The Separations and Safeguards Performance Model (SSPM) is an analysis tool that is used for modeling advanced monitoring systems and to determine system response under diversion scenarios. This report both describes the architecture for such a future monitoring system and present results under various diversion scenarios. Improvements made in the past year include the development of statistical tests for detecting material loss, the integration of material balance alarms to improve physical protection, and the integration of administrative procedures. The SSPM has been used to demonstrate how advanced instrumentation (as developed in the Material Protection, Accounting, and Control Technologies campaign) can benefit the overall safeguards system as well as how all instrumentation is tied into the physical protection system. This concept has the potential to greatly improve the probability of detection for both abrupt and protracted diversion of nuclear material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TH-A-12A-01: Medical Physicist's Role in Digital Information Security: Threats, Vulnerabilities and Best Practices

I. Information Security Background (Speaker = Kevin McDonald) Evolution of Medical Devices Living and Working in a Hostile Environment Attack Motivations Attack Vectors Simple Safety Strategies Medical Device Security in the News Medical Devices and Vendors Summary II. Keeping Radiation Oncology IT Systems Secure (Speaker = Bruce Curran) Hardware Security Double-lock Requirements “Foreign” computer systems Portable Device Encryption Patient Data Storage System Requirements Network Configuration Isolating Critical Devices Isolating Clinical Networks Remote Access Considerations Software Applications / Configuration Passwords / Screen Savers Restricted Services / access Software Configuration Restriction Use of DNS to restrict accesse. Patches / Upgrades Awareness Intrusion Prevention Intrusion Detection Threat Risk Analysis Conclusion Learning Objectives: Understanding how Hospital IT Requirements affect Radiation Oncology IT Systems. Illustrating sample practices for hardware, network, and software security. Discussing implementation of good IT security practices in radiation oncology. Understand overall risk and threats scenario in a networked environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nevada National Security Site Environmental Report 2010

This NNSSER was prepared to satisfy DOE Order DOE O 231.1B, “Environment, Safety and Health Reporting.” Its purpose is to (1) report compliance status with environmental standards and requirements, (2) present results of environmental monitoring of radiological and nonradiological effluents, (3) report estimated radiological doses to the public from releases of radioactive material, (4) summarize environmental incidents of noncompliance and actions taken in response to them, (5) describe the NNSA/NSO Environmental Management System and characterize its performance, and (6) highlight significant environmental programs and efforts. This NNSSER summarizes data and compliance status for calendar year 2010 at the Nevada National Security Site (NNSS) (formerly the Nevada Test Site) and its two support facilities, the North Las Vegas Facility (NLVF) and the Remote Sensing Laboratory–Nellis (RSL-Nellis). It also addresses environmental restoration (ER) projects conducted at the Tonopah Test Range (TTR). Through a Memorandum of Agreement, NNSA/NSO is responsible for the oversight of TTR ER projects, and the Sandia Site Office of NNSA (NNSA/SSO) has oversight of all other TTR activities. NNSA/SSO produces the TTR annual environmental report available at http://www.sandia.gov/news/publications/environmental/index.html.

54 ENVIRONMENTAL SCIENCES↗

Procedure for Performing Security Camera Optical Performance Analysis Tests

Digital security camera technologies proliferate the security marketplace with manufacturers extoling the functions, features, specifications and virtues of their cameras. A process to comparatively analyze security camera technologies using international camera analysis standards and methods provides a defensible means to assess camera image quality on a technically comparable basis. The procedures in this document use ISO standard camera test charts and camera image analysis software to perform test chart image analysis for comparative camera assessment. Step-by-step procedures for acquiring test chart images in the laboratory and producing analysis data using analysis software GUI controls and interfaces for comparative analysis of security camera image quality are detailed in this document. The procedures have been validated through the test and analysis of fixed box and 180 degree field of view multi-imager cameras as well as, fixed and varifocal lenses and analog-to-digital video encoder image quality performance attributes.

42 ENGINEERING↗

Joint Analysis of Surface Deformation Data for Reservoir Management Final Report CRADA No. TC02107.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Chevron North America Exploration and Production Company, a division of Chevron U.S.A. Inc. (Chevron), to develop an operational tool to carry out joint inversion of global positioning system (GPS), Interferometric Synthetic Aperture Radar (InSAR) and tilt, temperature, and electrical resistivity data to monitor the temporal and spatial evolution of fluid volume and temperature in a thermal diatomite oilfield.

15 GEOTHERMAL ENERGY↗

Validation Data for Benchmarking Wire Arc Additive Manufacturing Process Simulations

Residual stresses cause geometric distortion and affect mechanical performance of additively manufactured structures, yet they are notoriously difficult to assess and predict. Distortion (warpage) can drive parts outside dimensional tolerance limits, leading to part rejection or rework. For parts that meet tolerance, locked-in residual stress fields can affect structural integrity during operation, particularly subcritical cracking by fatigue, creep, or corrosion. This work develops benchmark data for a common additive manufacturing process (Wire Arc Additive Manufacturing) that can be applied for calibration and validation of physical process models that predict residual stress fields. The work includes design of two different samples of differing geometry, detailed manufacturing records for a set of physical samples, and an extensive set of residual stress measurement data developed using two diverse techniques (the contour method and neutron diffraction). An initial application of the work is also reported, where a modeling challenge was issued to secure residual stress model predictions from two independent laboratories that were blind to residual stress measurement data. These initial blind residual stress predictions show significant discrepancies relative to the measurement data, illustrating the potential value of the underlying validation data. An open repository for this work, including the sample designs, manufacturing process records, and the residual stress data, is also provided for future application in non-blind validation efforts.

36 MATERIALS SCIENCE↗

Toward Real Time Data Analysis for Smart Grids

This paper describes the architecture and design of a novel system for supporting large-scale real-time data analysis for future power grid systems. The widespread deployment of renewable generation, smart grid controls, energy storage, plug-in hybrids, and new conducting materials will require fundamental changes in the operational concepts and principal components of the grid. As a result, the whole system becomes highly dynamic and requires constant adjusting based on real time data. Even though millions of sensors such as phase measurement units (PMU) and smart meters are being widely deployed, a data layer that can analyze this amount of data in real time is needed. Unlike the data fabric in other cloud services, the data layer for smart grids has some unique design requirements. First, this layer must provide real time guarantees. Second, this layer must be scalable to allow a large number of applications to access the data from millions of sensors in real time. Third, reliability is critical and this layer must be able to continue to provide service in face of failures. Fourth, this layer must be secure. We address these challenges though a scalable system architecture that integrates the I/O and data processing capability in a devise set of devices. Data process operations can be placed anywhere from sensors, data storage devices, to control centers. We further employ compression to improve performance. We design a lightweight compression customized for power grid data. Our system can reduce end-to-end response time by reduce I/O overhead through compression and overlap compression operations with I/O. The initial prototype of our system was demonstrated with several use cases from PNNL’s FPGI and show that our system can provide real time guarantees to a diverse set of applications.

Data Analytics, Power Grid, Big Data↗

DER Cybersecurity Detection and Response Suite

SAND2024-08475O The Distributed Energy Resource (DER) Cybersecurity Detection and Response Suite is a solution for distributed energy resource (DER) systems. The DER Security Orchestration, Automation, and Response (SOAR) solution that uses alerts from signature- and behavior-based Intrusion Detection Systems are intended to be deployed as bump-in-the-wire (BITW) devices in front of DER equipment. The fielded application would use multiple intrusion detection systems that report data to SOAR to respond to cyberattacks. The suite consists of two software components: • The proactive intrusion detection and mitigation system (PIDMS) secures grid-edge photovoltaic smart inverters and other equipment in distributed energy resource systems. It is a distributed BITW solution; cyber and physical data are automatically processed using network inspection tools and custom machine learning algorithms to detect abnormal events and correlate cyber-physical events. • The Security Orchestration, Automation, and Response for Distributed Energy Resources (SOAR4DER) application ingests data from several intrusion detection systems to quickly block attacks and revert DER systems to good states. Using a collection of intrusion detection system technologies on a BITW device, it incorporates physical and cyber data to detect abnormal and potential malicious behaviors. Multiple SOAR playbooks then use the intrusion detection system data streams to automatically defend the system. SOAR4DER system testing showed detection and response times under 30 seconds for all adversary reconnaissance, denial-of-service attacks, malicious Modbus commands, brute-force logins, and machine-in-the-middle attacks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗

A Privacy First Path Analysis using Clickstream Data

In the modern digital economy, data-driven decision making is crucial for effectively meeting the ever-evolving demands of consumer engagement and satisfaction. Clickstream data has become invaluable for understanding customer behavior, yet concerns over privacy and security persist, especially with some internet service providers profiting from its sale. This article introduces an innovative methodology that blends experiential learning with advanced cryptographic techniques, including differential privacy and graph analytics. The core objective of this methodology is to estimate Customer Lifetime Value (CLV) by analyzing clickstream data, achieving an average prediction accuracy of 92.4% in user engagement levels while ensuring user anonymity through Recency, Frequency, and Monetary (RFM) analysis. Our study introduces the concept of a “data depositor” and a privacy manager, employing the composition theorem to merge non-adaptive queries effectively. Privacy budgets (? = 1.0, d = 10-5), sensitivity-specific techniques, and data partitioning were applied. Randomization and noise addition protect data integrity, with special handling for categorical values. This approach, differing from prior studies, offers a 12.6% improvement in privacy-preserving targeting accuracy while maintaining strict confidentiality, presenting a novel path forward in data-driven decision-making.

Frequency and Monetary (RFM) analysis↗

Late Breaking Results: COPPER: Computation Obfuscation by Producing Permutations for Encoding Randomly

Deployed embedded devices face security risks due to increased ease of physical access to the devices by unauthorized users. Capable adversaries can intercept a device to recover the data in memory, including results of performed sensitive computations. Device owners require data confidentiality on their physically insecure devices. To satisfy this goal we implement a novel method, COPPER (Computation Obfuscation by Producing Permutations for Encoding Randomly), to create data which never exists on the device digitally in plaintext format and which is subsequently used for computation. In this paper we utilize COPPER to calculate a moving average computation on encoded data.

embedded systems↗

OCGen Module Mooring Project

Ocean Renewable Power Company's OCGen Module Mooring Project provided an extensive research, design, development, testing and data collection effort and analysis conducted with respect to a positively buoyant, submerged MHK device secured to the seabed using a tensioned mooring system. Different analytic tools were evaluated for their utility in the design of submerged systems and their moorings. Deployment and testing of a prototype OCGen® system provided significant data related to mooring line loads and system attitude and station keeping. Mooring line loads were measured in situ and reported against flow speeds. The Project made a significant step in the development of designs, methodologies and practices related to floating and mooring of marine hydrokinetic (MHK) devices. Importantly for Ocean Renewable Power Company, the Project provided a sound basis for advancing a technically and commercially viable OCGen® Power System. The OCGen® Power System is unique in the MHK industry and, in itself, offers distinct advantages of MHK devices that are secured to the seabed using fixed structural frames. Foremost among these advantages are capital and operating cost reductions and increased power extraction by allowing the device to be placed at the most energetic level of the water column.

16 TIDAL AND WAVE POWER↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

Centers for Disease Control and Prevention (CDC) Radiation Hazard Scale (Expanded Data Product Feedback Report)

During radiation emergencies, it is important to communicate clearly as radiation risks are often unfamiliar to many members of the general public and emergency responders, including public health workers. To partially address this issue, the Centers for Disease Control and Prevention (CDC) developed the Radiation Hazard Scale to communicate radiation risk to the general public, community leaders, and decision makers. The simple numeric scale does not require a background in radiation physics or health effects and can be used to assist people in understanding their risk and motivate protective action compliance. Lawrence Livermore National Laboratory has assisted the US Department of Energy National Nuclear Security Administration and the CDC in the development of Radiation Hazard Scale data products. This report documents the feedback received from Federal response officials on an expanded data product set. This expanded set accounts for the effects of building protection on radiation exposure and allows for the comparison between different response actions, including sheltering in place, based on the LLNL developed Regional Shelter Analysis methodology.

54 ENVIRONMENTAL SCIENCES↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.