Search NASA⌕ Search

SEARCH · Search NASA

Results for “07 ISOTOPE AND RADIATION SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a SnO 2 -based 44 Ti/ 44 Sc generator for medical applications

Towards application of 44 Sc for diagnostic nuclear medicine, a 44 Ti/ 44 Sc generator based on an inorganic resin has been evaluated. Unlike other radionuclide generators used for medical applications, the long-term retention of the parent 44 Ti is vital due to its long half life. In this work, tin dioxide (SnO 2 ), a robust inorganic-based resin, has been synthesized and used as the stationary phase for a 44 Ti/ 44 Sc generator. The sorption behavior of 44 Ti/ 44 Sc was tested on SnO 2 with varying acids, concentrations, and times. Preliminary batch study results showed >88 % 44 Ti retention to the resin at lower acid concentrations (0.05 M HNO 3 and 0.05 M HCl). A pilot generator was evaluated for a year, demonstrating 85.3 ± 2.8 % 44 Sc elution yields and 0.71 ± 0.14 % 44 Ti breakthrough in 5 M HNO 3 . Based on capacity studies, a 7.4 MBq (200 µCi) upscaled generator system was constructed for further evaluation of the SnO 2 resin stability and the efficacy of the eluted 44 Sc for radiolabeling. 44 Sc could be regularly eluted from this generator in 5 M HNO 3 with an overall average radiochemical yield 84.7 ± 9.5 %. Post-elution processing of the 44 Sc with DGA-normal resin removed all 44 Ti present and allowed for high 44 Sc-DOTA labeling yields of 94.2 ± 0.5 %. Overall, SnO 2 has been shown to be a viable material for a 44 Ti/ 44 Sc generator.

07 ISOTOPE AND RADIATION SOURCES↗

Surrogate-driven design optimization with uncertainty constraints in Monte Carlo simulations

In multi-objective design tasks, the computational cost increases rapidly when high-fidelity simulations are used to evaluate objective functions. Surrogate models help mitigate this cost by approximating the simulation output, simplifying the design process. However, under high uncertainty, surrogate models trained on noisy data can produce inaccurate predictions, as their performance depends heavily on the quality of training data. This study investigates the impact of data uncertainty on two multi-objective design problems modelled using Monte Carlo transport simulations: a neutron moderator and an ion-to-neutron converter. For each, a grid search was performed using five different tally uncertainty levels to generate training data for neural network surrogate models. These models were then optimized using NSGA-III. The recovered Pareto-fronts were analyzed across uncertainty levels: in the moderator problem, normalized hypervolume dropped from 0.886 at 1.0% uncertainty to 0.748 at 10% uncertainty, while in the converter problem it remained near 0.50 for all cases. Average simulation times were also compared to evaluate the trade-off between accuracy and computational cost. Results show that the influence of simulation uncertainty is strongly problem-dependent. In the neutron moderator case, higher uncertainties led to exaggerated objective sensitivities and distorted Pareto-fronts, reducing normalized hypervolume. In contrast, the ion-to-neutron converter task was less affected—low-fidelity simulations produced results similar to those from high-fidelity data. These findings suggest that a fixed-fidelity approach is not optimal. Surrogate models can recover the Pareto-front under noisy conditions, and multi-fidelity studies help identify suitable uncertainty levels for each problem to balance efficiency and accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

A window into atmospheric escape on early Mars provided by argon isotopes in a Martian meteorite

Novel analytical approaches to determining the trapped 38 Ar/ 36 Ar ratio of gases contained within Martian meteorites are presented and applied to the Martian regolith breccia Northwest Africa (NWA) 7034 and paired stone NWA 11220. The resulting data indicate that extensive mass-dependent fractionation of atmospheric Ar may have occurred within 150 million years of planetary formation, ostensibly as a result of diffusion-limited hydrodynamic escape. The inferred fractional loss of Ar and lighter atmospheric constituents exceeds 50%. In conclusion, these data suggest that volatiles derived from planetary outgassing and/or impactors may dominate the present abundance of atmospheric Ar.

07 ISOTOPE AND RADIATION SOURCES↗

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Verification of Bison fission product species conservation under TRISO reactor conditions

When assessing the reliability and predictive capabilities of a simulation tool, code verification is used to ensure that the implemented numerical algorithm is a faithful representation of its underlying mathematical model, including partial differential or integral equations, initial and boundary conditions, and auxiliary relationships. During this process, numerical results in a discrete solution are compared to the analytical solution of the mathematical model. Here, in this paper, the code verification process is applied to one-dimensional spatiotemporal problems that exercise partial differential equation governing the conservation of fission product species (or mass diffusion). Numerical experiments were performed in the Bison fuel performance code to evaluate its predictive capability under various TRISO reactor conditions such as base irradiation and safety heating test conditions for either short- or long-lived fission product species, as well as a case concerning evaporation from the outer surface of a particle. The code predictions were compared with the expected exact results obtained from the analytical expressions, and the fact that they demonstrate the correct analytical behavior provides strong evidence of proper numerical algorithm implementation.

07 ISOTOPE AND RADIATION SOURCES↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Radioarsenic: A promising theragnostic candidate for nuclear medicine

Molecular imaging is a non-invasive process that enable the visualization, characterization, and quantitation of biological processes at the molecular and cellular level. With the emergence of theragnostic agents to diagnose and treat disease for personalized medicine there is a growing need for matched pairs of isotopes. Matched pairs offer the unique opportunity to obtain patient specific information from SPECT or PET diagnostic studies to quantitate in vivo function or receptor density to inform and tailor therapeutic treatment. There are several isotopes of arsenic that have emissions suitable for either or both diagnostic imaging and radiotherapy. Their half-lives are long enough to pair them with peptides and antibodies which take longer to reach maximum uptake to facilitate improved patient pharmacokinetics and dosimetry then can be obtained with shorter lived radionuclides. Arsenic-72 even offers availability from a generator that can be shipped to remote sites and thus enhances availability. Arsenic has a long history as a diagnostic agent, but until recently has suffered from limited availability, lack of suitable chelators, and concerns about toxicity have inhibited its use in nuclear medicine. However, new production methods and novel chelators are coming online and the use of radioarsenic in the pico and nanomolar scale is well below the limits associated with toxicity. This manuscript will review the production routes, separation chemistry, radiolabeling techniques and in vitro/in vivo studies of three medically relevant isotopes of arsenic (arsenic-74, arsenic-72, and arsenic-77).

07 ISOTOPE AND RADIATION SOURCES↗

Development and biodistribution studies of 77 As-labeled trithiol RM2 bioconjugates for prostate cancer: Comparison of [ 77 As]As-trithiol-Ser-Ser-RM2 vs. [ 77 As]As-trithiol-Glu-Ser-RM2

Recent progress with the production of 72 As (2.49 Mev β + max (64%), 3.33 Mev β + max (16%), 834 keV (81%), t 1/2 : 26 h) and 77 As (0.683 Mev β- max (97%), 239 keV (1.59%), t 1/2 : 38.8 h) has facilitated their evaluation as a potential “theranostic pair” for PET imaging and radiotherapy. Our 3 rd generation trithiol chelate with two carboxylic acid groups was further developed as a bifunctional chelate for radioarsenic. The As complex with the trithiol chelate was synthesized and characterized. No carrier added (nca) [ 77 As][H 2 AsO 4 - ] was used for radiolabeling studies. Here, the trithiol chelate was conjugated to the RM2 peptide (DPhe-Gln-Trp-Ala-VaI-Gly-His-Sta-Leu-NH 2 ) via solid phase peptide synthesis with two different linkers, Ser-Ser and Glu-Ser. The trithiol chelate and its RM2 bioconjugates were radiolabeled with nca 77 As, and the RM2 bioconjugates were compared in initial biodistribution studies. The As diacid trithiol complex was characterized by 1 H NMR, 13 C NMR and HR-ESI-MS. The trithiol-RM2 precursor and As trithiol bioconjugates were characterized by HR-ESI-MS and/or LC-ESI-MS. Radiolabeling of the RM2 bioconjugates with 77 As resulted in over 85% radiochemical yield for [ 77 As]As-trithiol-Ser-Ser-RM2 ([ 77 As]8) and 90% for [ 77 As]As-trithiol-Glu-Ser-RM2 ([ 77 As]9). Both radiotracers demonstrated excellent in vitro stability (≥ 90% remaining intact through 24 h in PBS buffer) and were more hydrophilic than previous analogues based on log D 7.4 values. Biodistribution results of the two radiotracers in healthy CF-1 male mice demonstrated blockable pancreatic uptake at 1 h (82% for ([ 77 As]8 and 78% for [ 77 As]9) indicating specific gastrin-releasing peptide receptor (GRPR) uptake. The primary route of excretion was through the gastrointestinal system for both radiotracers. A new trithiol chelate with improved hydrophilicity was successfully conjugated to the RM2 peptide via two linkers, and high radiolabeling yield with nca 77 As was achieved. In vivo biodistribution studies with both radiotracers demonstrated blockable pancreatic uptake suggestive of specific receptor uptake.

07 ISOTOPE AND RADIATION SOURCES↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

Efficient Thermal Processes Using Alternating Electromagnetic Field for Methodical and Selective Release of Hydrogen Isotopes

The controlled and selective release of hydrogen isotopes from Lanthanum-Nickel-Aluminum (LANA) materials was achieved using an alternating electromagnetic field (AEMF). Here, in the presence of the AEMF, the rate of desorption for D 2 was faster than for H 2 . In a closed system, compared to control experiments with helium, hydrogen-loaded LANA samples showed a significant increase in pressure which illustrates the desorption of hydrogen from the applied AEMF. An exponential increase in the hydrogen release rate was observed with increased AEMF strength. Additionally, hydrogen release from LANA confined in a subzero environment (-78°C) using an AEMF was demonstrated. These results demonstrate that the LANA material can be heated directly using alternating electromagnetic fields rather than indirectly to rapidly and selectively desorb hydrogen isotopes. The rapid response and difference in desorption kinetics for different hydrogen isotopes in the presence of the alternating electromagnetic fields provide a promising pathway for applications requiring controlled release of hydrogen and separation of its isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Toward Rapid Actinium-225 Purification via Membrane Adsorbers with Covalently Tethered Diglycolamide Ligands

Extractive diglycolamide (DGA) resins are used in several state-of-the-art techniques for purifying 225 Ac, a promising radiometal for targeted alpha therapy. Unfortunately, separation processes that rely on resins are often limited to slow flow rates, high elution volumes, and long processing times. Membrane adsorbers functionalized with DGA ligands are an alternative separation material that may overcome these challenges. This work presents (1) the synthesis of an aminated tetrahexyldiglycolamide ligand, (2) the covalent tethering of the ligand to electrospun poly(vinylbenzyl chloride) fiber mats, and (3) the adsorption and desorption of La(III) and 225 Ac. Chemical and physical characterization supports the covalent tethering of the ligand to the fiber mat, as well as the preservation of the fiber surface area and porosity after functionalization. Equilibrium adsorption experiments were performed with stable La(III) and radioactive 225 Ac. Trends in affinity are consistent between commercial resins and the synthesized membrane adsorbers; however, the Langmuir constants and the maximum binding capacity of the membrane adsorbers were generally lower than the resins. Despite these differences, the modeled selectivity for an equimolar solution of La(III)/ 225 Ac in 10 M nitric acid is 57. Furthermore, 225 Ac is rapidly desorbed from the fibers in 10 M nitric acid (<20 min). The La(III)/ 225 Ac selectivity and rapid 225 Ac desorption indicate this class of materials is promising for rapid radioanalytical separations.

07 ISOTOPE AND RADIATION SOURCES↗

Oxygen Isotope Fractionation in U 3 O 8 during Thermal Processing in Humid Atmospheres

The incorporation of oxygen isotopes from water into uranium oxides during industrial processing presents a pathway for determining a material’s geographical origin. This study is founded on the hypothesis that oxygen isotopes from atmospheric water vapor will exchange with isotopes of oxygen in solid uranium oxides during thermal processing or calcination. Using a commonly encountered oxide, U 3 O 8 , the exchange kinetics and equilibrium fractionation with water vapor (in a concentration range of 50–55% relative humidity) were investigated using processing temperatures of 400, 600, and 800 °C. In an atmosphere containing only water vapor diluted in N 2 , oxygen isotope equilibration in U 3 O 8 occurred within 12 h at 400 °C and within 2 h at 600 and 800 °C. Fractionation factors (1000lnα, U 3 O 8 –H 2 O) between the water and oxide were –12.1, –11.0, and –8.0 at 400, 600, and 800 °C, respectively. With both humidity and O 2 present in the calcining atmosphere, isotopic equilibration is attained within 2 h at and above 400 °C. In this mixed atmosphere, which was designed to emulate Earth’s troposphere, isotopes are incorporated preferentially from water vapor at 400 °C and from O 2 at 600 and 800 °C. Rapid and temperature/species-dependent isotope exchange also elucidated the impact of retrograde exchange in humid air, showing a shift from O 2 -dependent to H 2 O-dependent fractionation as U 3 O 8 cooled from 800 °C. These results confirm that uranium oxides inherit oxygen isotopes from humidity during thermal processing, illuminating an important mechanism in the formation of this forensic signature.

07 ISOTOPE AND RADIATION SOURCES↗