Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Wavelength Dependence of Activity-induced Photometric Variations for Young Cool Stars in Hyades

We investigate photometric variations due to stellar activity that induce systematic radial-velocity errors (so-called “jitter”) for the four targets in the Hyades open cluster observed by the K2 mission (EPIC 210721261, EPIC 210923016, EPIC 247122957, and EPIC 247783757). Applying Gaussian process regressions to the K2 light curves and the near-infrared (NIR) light curves observed with the IRSF 1.4 m telescope, we derive the wavelength dependences of the photometric signals due to stellar activity. To estimate the temporal variations in the photometric variability amplitudes between the two observation periods of K2 and IRSF, separated by more than 2 yr, we analyze a number of K2 targets in Hyades that have also been observed in Campaigns 4 and 13 and find a representative variation rate over 2 yr of 38% ± 71%. Taking this temporal variation into account, we constrain projected sizes and temperature contrast properties of the starspots in the stellar photosphere to be approximately 10% and 0.95%, respectively. These starspot properties can induce relatively large differences in the variability amplitude over different observational passbands, and we find that radial-velocity jitter may be more suppressed in the NIR than previously expected. Our result supports profits of ongoing exoplanet search projects that are attempting to detect or confirm young planets in open clusters via radial-velocity measurements in the NIR.

47 OTHER INSTRUMENTATION↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Divertor heat flux challenge and mitigation in SPARC

Owing to its high magnetic field, high power, and compact size, the SPARC experiment will operate with divertor conditions at or above those expected in reactor-class tokamaks. Power exhaust at this scale remains one of the key challenges for practical fusion energy. Based on empirical scalings, the peak unmitigated divertor parallel heat flux is projected to be greater than 10 GW m -2 . This is nearly an order of magnitude higher than has been demonstrated to date. Furthermore, the divertor parallel Edge-Localized Mode (ELM) energy fluence projections (~11–34 MJ m -2 ) are comparable with those for ITER. However, the relatively short pulse length (~25 s pulse, with a ~10 s flat top) provides the opportunity to consider mitigation schemes unsuited to long-pulse devices including ITER and reactors. The baseline scenario for SPARC employs a ~1 Hz strike point sweep to spread the heat flux over a large divertor target surface area to keep tile surface temperatures within tolerable levels without the use of active divertor cooling systems. In addition, SPARC operation presents a unique opportunity to study divertor heat exhaust mitigation at reactor-level plasma densities and power fluxes. Not only will SPARC test the limits of current experimental scalings and serve for benchmarking theoretical models in reactor regimes, it is also being designed to enable the assessment of long-legged and X-point target advanced divertor magnetic configurations. Experimental results from SPARC will be crucial to reducing risk for a fusion pilot plant divertor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carnegie Supernova Project II: The Slowest Rising Type Ia Supernova LSQ14fmg and Clues to the Origin of Super-Chandrasekhar/03fg-like Events

The Type Ia supernova (SN Ia) LSQ14fmg exhibits exaggerated properties that may help to reveal the origin of the "super-Chandrasekhar"(or 03fg-like) group. The optical spectrum is typical of a 03fg-like SN Ia, but the light curves are unlike those of any SNe Ia observed. The light curves of LSQ14fmg rise extremely slowly. At -23 rest-frame days relative to B-band maximum, LSQ14fmg is already brighter than M V = -19 mag before host extinction correction. Here, the observed color curves show a flat evolution from the earliest observation to approximately 1 week after maximum. The near-infrared light curves peak brighter than -20.5 mag in the J and H bands, far more luminous than any 03fg-like SNe Ia with near-infrared observations. At 1 month past maximum, the optical light curves decline rapidly. The early, slow rise and flat color evolution are interpreted to result from an additional excess flux from a power source other than the radioactive decay of the synthesized 56 Ni. The excess flux matches the interaction with a typical superwind of an asymptotic giant branch (AGB) star in density structure, mass-loss rate, and duration. The rapid decline starting at around 1 month past B-band maximum may be an indication of rapid cooling by active carbon monoxide (CO) formation, which requires a low-temperature and high-density environment. These peculiarities point to an AGB progenitor near the end of its evolution and the core degenerate scenario as the likely explosion mechanism for LSQ14fmg.

79 ASTRONOMY AND ASTROPHYSICS↗

The new ITER baseline, research plan and open R&D issues

A new baseline (NB) has been proposed by the ITER Project to ensure a robust achievement of the Projects’ goals, in view of past challenges including delays incurred due to the Covid-19 pandemic, technical challenges in completing first-of-a-kind components and in nuclear licensing. The NB includes modifications to the configuration of the ITER device and its ancillaries (e.g. change from beryllium to tungsten as first wall material, modification of the heating and current drive mix, etc.) as well as additional testing of components (e.g. toroidal field coils) or phased installation (start with inertially cooled first wall before later installation of the final actively water-cooled components) to minimise operational risks. In the NB, the ITER research plan (IRP) will be divided into three main phases: (a) start of research operation, with 40 MW of ECH and 10 MW of ICH, which will focus on the demonstration of 15 MA operation in L-mode, commissioning of all required systems, including disruption mitigation, and the demonstration of H-mode plasma operation in deuterium; (b) DT-1, with 60–67 MW of ECH, 33 MW of neutral beam injection (NBI) and 10–20 MW of ICH, which will demonstrate robust operation in high confinement H-mode plasmas in DT up to Q ⩾ 10 and for burn durations of 300–500 s within an accumulated neutron fluence of ∼1% of the ITER machine’s lifetime total, and; (c) DT-2, with up to 67 MW of ECH, up to 49.5 MW of NBI and up to 20 MW of ICH, with the ITER tokamak and ancillaries in their final configuration to demonstrate routine operation in DT plasmas at high Q and the Q ⩾ 5 long-pulse and steady-state scenarios to the final neutron fluence and to perform R&D on nuclear fusion reactor issues. The logic, physics basis, modelling and experimental evaluations carried out to support the NB and the associated IRP are described. These include the impact of the tungsten wall on plasma scenarios and associated risk mitigation measures, as well as the optimisation of the tokamak components and ancillaries to minimise Project risks. Open R&D issues related to these evaluations and mitigation measures are also described together with experimental, modelling and validation activities required to address them.

ITER↗

Activation mechanism of the mouse cold-sensing TRPM8 channel by cooling agonist and PIP 2

The transient receptor potential melastatin 8 (TRPM8) channel is the primary molecular transducer responsible for the cool sensation elicited by menthol and cold in mammals. TRPM8 activation is controlled by cooling compounds together with the membrane lipid phosphatidylinositol 4,5-bisphosphate (PIP 2 ). Our knowledge of cold sensation and the therapeutic potential of TRPM8 for neuroinflammatory diseases and pain will be enhanced by understanding the structural basis of cooling agonist- and PIP 2 -dependent TRPM8 activation. We present cryo–electron microscopy structures of mouse TRPM8 in closed, intermediate, and open states along the ligand- and PIP 2 -dependent gating pathway. Our results uncover two discrete agonist sites, state-dependent rearrangements in the gate positions, and a disordered-to-ordered transition of the gate-forming S6—elucidating the molecular basis of chemically induced cool sensation in mammals.

Science & Technology - Other Topics↗

Interpretative 3D MHD modelling of deuterium SPI into a JET H-mode plasma

Abstract The pre-thermal quench (pre-TQ) dynamics of a pure deuterium ( D 2 ) shattered pellet injection (SPI) into a 3 MA / 7 MJ JET H-mode plasma is studied via 3D non-linear MHD modelling with the JOREK code. The interpretative modelling captures the overall evolution of the measured density and radiated power. The simulations also identify the importance of the drifts of ablation plasmoids towards the tokamak low field side (LFS) and the impurities in the background plasma in fragment penetration, assimilation, radiative cooling and MHD activity in D 2 SPI experiments. It is found that plasmoid drifts lead to an about 70% reduction of the central line-integrated density (compared to a simulation without drifts) in the JET D 2 SPI discharge considered. Impurities that pre-exist before the SPI as well as those from possible impurity influxes related to the SPI are shown to dominate the radiation in the considered discharge. With inputs from JOREK simulations, modelling with the Lagrangian particle-based pellet code PELOTON reproduces the deviation of the SPI fragments in the direction of the major radius as observed by the fast camera. This confirms the role of rocket effects and plasmoid drifts in the considered discharge and reinforces the validity of the JOREK modelling. The limited core density rise due to plasmoid drifts and the strong radiative cooling and MHD activity with impurities (depending on their species and concentration) could limit the effectiveness of LFS D 2 SPI in runaway electron avoidance and are worth considering in the design of the ITER disruption mitigation system.

Physics↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unlocking large compressive strains in thin active elastocaloric layers

Elastocaloric cooling attracts broad interest and rapidly growing attention due to its potential for high efficiency and low environmental impact. While it is common knowledge that triggering reversible entropy and temperature changes with stress applied in compression prevents rapid failures of materials, realizing this regime in elastocaloric systems is highly challenging because nearly all geometries suited for efficient heat transfer are prone to buckling even under modest loads. This work describes a concept of a novel composite, where an active NiTi layer is embedded into a polymer support structure such that the elastocaloric material is entirely in compression when the assembly is subjected to bending. The active layer achieves 8.1 K temperature change at 2.5% compressive strain without buckling. After 10,000 cycles at 2% compressive strain, the composite maintains mechanical integrity without degradation of the elastocaloric effect. The results demonstrate that NiTi and, potentially, other elastocalorically active materials in geometries previously thought impossible can be successfully implemented in regenerative cooling systems operating in compression.

42 ENGINEERING↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

Aging of Limestones and Silane–Siloxane-Based Protective Hydrophobics: The Impact of Heating–Cooling and Freeze–Thaw Cycles

Stones are traditionally used in construction and architectural applications as building elements due to their aesthetic and technical/structural performance. Like other environmental factors (rain, humidity, moisture, salt presence, biological activity, etc.), heating–cooling and freeze–thaw cycles significantly threaten the longevity of stone materials. Hence, considering the socio-economic and cultural value of stones, preventive actions such as hydrophobic coatings are applied to prevent or mitigate damage. The scope of this study is the performance assessment of limestones with different characteristics and the efficiency of various commercial silane/siloxane-based hydrophobic coatings when exposed to thermal variation and freeze–thaw. For that purpose, the standards EN 14066:2013 (determination of resistance to aging by thermal shock) and EN 12371:2010 (determination of frost resistance) were followed. Open porosity and static contact angles were estimated to assess the stone durability and water protection capabilities of the hydrophobics. Additionally, sound speed propagation velocity, quality of building material index, elastic modulus and flexural strength were measured to evaluate the variation of mechanical properties. Static contact angle revealed that the coatings maintained an efficient level of hydrophobicity even after thermal-shock and freeze–thaw weathering tests. The study also revealed a critical interaction between freeze–thaw cycles, hydrophobic coatings and structural integrity of the stones, mostly on more porous ones. When they are subjected to harsh environmental conditions, untreated porous limestones keep structural cohesion, allowing for the natural absorption and release of water during freezing and thawing. On the contrary, when limestones are treated, the hydrophobic coatings can moderately obstruct the water release due to the partial saturation of the porous framework by the products. It also probably resulted from the different mechanical behavior between the inner matrix and layer of stone coated, resulting in a premature breakout and mechanical damage of the stone.

Lisci, Carla (ORCID:000000032179130X)↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗