Convective Heating of the LIFE Engine Target During Injection

Target survival in the hostile, high temperature xenon environment of the proposed Laser Inertial Fusion Energy (LIFE) engine is critical. This work focuses on the flow properties and convective heat load imposed upon the surface of the indirect drive target while traveling through the xenon gas. While this rarefied flow is traditionally characterized as being within the continuum regime, it is approaching transition where conventional CFD codes reach their bounds of operation. Thus ANSYS, specifically the Navier-Stokes module CFX, will be used in parallel with direct simulation Monte Carlo code DS2V and analytically and empirically derived expressions for heat transfer to the hohlraum for validation. Comparison of the viscous and thermal boundary layers of ANSYS and DS2V were shown to be nearly identical, with the surface heat flux varying less than 8% on average. From the results herein, external baffles have been shown to reduce this heat transfer to the sensitive laser entrance hole (LEH) windows and optimize target survival independent of other reactor parameters.

42 ENGINEERING↗

Design and Integrate Improved Systems for Nuclear Facility Ventilation and Exhaust Operations

Objective: The objective of this R&D project would complete the development of three new systems and integrate them into a single experimental effort. However, each of the three systems has stand-alone applicability across the DOE complex. At US DOE nuclear facilities, indoor air is filtered and ventilated for human occupancy, and exhaust air to the outdoor environment must be regulated and monitored. At least three technical standards address these functions, and the Los Alamos National Laboratory would complete an experimental facility to answer at least three questions: (1) Can the drag coefficient of a new Los Alamos air mixer be reduced for better operation in nuclear facility exhaust stacks? (2) Is it possible to verify the accuracy of a new dilution method for HEPA filter test facilities? (3) Is there a performance-based air flow metric (volumetric flow or mass flow) for operating HEPA filters? In summary, the three new systems are: a mixer, a diluter and a performance-based metric, respectively. The results of this project would be applicable to at least four technical standards: ANSI N13.1 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities; ASTM F1471 Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air Filter System, ASME N511: In-Service Testing of Nuclear Air Treatment, Heating, Ventilating, and Air-Conditioning Systems, and ASME AG-1: Code On Nuclear Air And Gas Treatment. All of the three proposed new systems must be combined into a single experimental device (i.e. to develop a new function of the Los Alamos aerosol wind tunnel). Technical Approach: The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally (2006) designed to evaluate small air samplers (cf. US EPA 40 CFR 53.42). In 2009, the tunnel was modified for exhaust stack verifications per the ANSI N13.1 standard. In 2010, modifications were started on the wind tunnel for testing HEPA filters (cf. ASTM F1471 and ASME N511). This project involves three systems that were developed for testing the 24*24*11 (inch) HEPA filters (i.e. the already mentioned mixer, diluter and metric). Prototypes of the mixer and the diluter have been built and individually tested on a preliminary basis. However, the third system (the HEPA metric method) has not been tested, since that requires complete operability of the aerosol wind tunnel device. (The experimental wind tunnel has test aerosol injection, control and measurement capabilities, and can be heated for temperature dependent measurements.) Benefits: US DOE facilities that use HEPA filters and/or require exhaust stacks from their nuclear facility buildings will benefit from access to the new hardware (mixer and diluter) and performance-based metric (for HEPA filter air flow).

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiaxial Creep-Fatigue and Creep-Ratcheting Failures of Grade 91 and Haynes 230 Alloys Toward Addressing Design Issues of Gen IV Nuclear Power Plants

The proposed research will develop systematic sets of uniaxial and multiaxial experimental data at a very high temperature (850-950°C) for Alloy 617. The loading histories to be prescribed in the experiments will induce creep-fatigue and creep-ratcheting failure mechanisms. These experimental responses will be scrutinized in order to quantify the influences of temperature and creep on fatigue and ratcheting failures. A unified constitutive model (UCM) will be developed and validated against these experimental responses. The improved UCM will be incorporated into the widely used finite element commercial software packages ANSYS. The modified ANSYS will be validated so that it can be used for evaluating the very high temperature ASME-NH design-by-analysis methodology for Alloy 617 and thereby addressing the ASME-NH design code issues.

36 MATERIALS SCIENCE↗

Neutron Sources for Standard-Based Testing

The DHS TC Standards and the consensus ANSI Standards use 252 Cf as the neutron source for performance testing because its energy spectrum is similar to the 235 U and 239 Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

07 ISOTOPE AND RADIATION SOURCES↗

Respirators: Supervisors Self-Study #43442

This course, Respirators: Supervisors Self-Study (#43442), addresses training requirements for supervisors of respirator wearers as specified by the American National Standard Institute (ANSI) Standard for Respiratory Protection, ANSI Z88.2, and as incorporated by reference in the Department of Energy (DOE) Worker Health and Safety Rule, 10 Code of Federal Regulations (CFR) 851. This course also presents the responsibilities of supervisors of respirator wearers at Los Alamos National Laboratory (LANL).

99 GENERAL AND MISCELLANEOUS↗

Nanotechnology Standardization Activities – Support of U.S. Representation on ISO/TC 229 Nanotechnologies

In carrying out its responsibilities on behalf of the United States, ANSI provides comprehensive, administrative support and expertise on international protocols and procedures to: (1) the U.S. Technical Advisory Group (TAG) to the International Organization for Standardization’s (ISO) Technical Committee (TC) 229 Nanotechnologies, and (2) the corresponding U.S. TAG Working Groups tasked with formulating U.S. positions on topics relevant to nanotechnology standardization. Additionally, secretariat and procedural support is provided for the ISO/TC 229 WG 3 on health, safety and environment, for which the United States was assigned leadership by the participating national body members of ISO/TC 229. As the official entity that serves as the U.S. representative to ISO, ANSI provides not only expert coordination of U.S. positions and representation at ISO but also strategic direction, advice and procedural expertise to facilitate navigation of international issues to promote U.S. positions for incorporation into the ISO/TC 229 program of work necessary to support U.S. objectives.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Los Alamos National Laboratory Meteorology Monitoring Program: 2016 Data Completeness/ Quality Report

This report summarizes data completeness by tower and by instrument for 2016 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

58 GEOSCIENCES↗

Fibre Channel Development Final Report CRADA No. TC-0340-92-D

The Fibre Channel (FC) Development project was designed to enhance U.S. industrial competitiveness by accelerating the standardization and subsequent industrial acceptance of the American National Standards Institute’s (AIW) Fibre Channel Standard (now X3T1 1). It was also intended to give the principal U.S. participants a one- to two-year lead in developing heterogeneous high-speed computer networks, dktibuted computing through clustering, scientific visualization techniques, and high speed channels. The project was proposed to benefit U.S. industry as these high performance computing methods became generally available. In 1992-93, during the initial project phases, Fibre Channel PC) was emerging as a new ANSI standard. It was envisioned as becoming the mechanism for data transfer between the next generation of computers, and between these computers and their peripherals. Using this channel standard, U.S. computer vendors were expecting to be able to provide high-speed interoperability between heterogeneous computers and their storage devices, with data transfer rates greater than a GBit/sec. Our project was composed of key principal players in the FC standardization effort from both U.S. industry and the Department of Energy’s (DOES) Lawrence Liverrnore National Laboratory (LLNL). The industial participants were developing individual FC interfaces to operate with their platform products. LLNL’s role was to be a neutral testing site and a facilitator for helping to resolve conflicting interpretations of the embryonic Fibre Channel specification. LLNL anticipated that conflicts in the interpretation of such a standard would arise and require neutral resolution and that such resolutions would best be achieved in cooperation with the ANSI FC Working Group. Project plans included transferring to U.S. industry any resilient FC testing capabilities at the project conclusion.

42 ENGINEERING↗

Los Alamos National Laboratory Meteorology Monitoring Program: 2017 Data Completeness/Quality Report

This report summarizes data completeness by tower and by instrument for 2017 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

54 ENVIRONMENTAL SCIENCES↗

Los Alamos National Laboratory Meteorology Monitoring Program: 2018 Data Completeness/Quality Report

This report summarizes data completeness by tower and by instrument for 2018 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

54 ENVIRONMENTAL SCIENCES↗

Annual Performance Testing of Tracer Gas Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP0F 1 regulations is managed by the Radioactive Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniform mixing of tracer gas (sulfur hexafluoride, SF 6 ) and tracer aerosol (liquid oil droplets) in the air stream. This memorandum will specifically focus on the tracer gas portion of the ANSI Standard. For these mix tests, tracer gas is injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of the media concentration must be under 20% when evaluated over the central 2/3 area of the stack or duct.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical investigation of coal particle modeling for the inlet section of a pressurized oxy-combustion burner

Concerns over climate change have led to numerous efforts to develop low-carbon technologies, and pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in the power industry. Designing an effective burner for such technologies is vital for the development of these and other coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the pressurized oxy-combustor burner is close to or even higher than the maximum limit for commercial CFD codes (e.g., ANSYS FLUENT). At these high particle volume fractions, the interactions among particles, fluid flow and wall need to be re-evaluated. The present computational work is a first step in a systematic analysis of the influence of various parameters, like method of particle release, release location, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In the POC process, pulverized coal is burned under elevated pressure in an O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing Ansys FLUENT commercial sodtware using the Reynolds-Averaged Navier-Stokes (RANS) approach. It is revealed that for this pilot-scale, pressurized burner, velocity profiles in the near-wall region exhibit some anomalies. In order to investigate the influence of particle loading in the near-wall region, particle release location was investigated. The numerical simulations incorporate the coupling between the turbulent flow and the particles. A sensitivity investigation of particle release location found that by tuning the release location, the velocity profile can be consistent with the pure gas flow velocity profile. More importantly, the particle releasing location also affects flame stability. Particle size was also found to have a significant impact on particle trajectory, flame stability and temperature. Finally, Large Eddy Simulations (LES) were performed and compared with the results from two-dimensional RANS.

Li, Lei↗

Impact of particle size and particle-flow-wall coupling on pressurized oxy-combustion in the down-fired burner

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the burner of a pressurized oxy-combustor is close or even higher than the maximum limit that commercial CFD codes (e.g., ANSYS FLUENT) can handle. At this high particle volume fraction, the interactions among particles, fluid flow, and wall need to be re-evaluated. The present computational work is the first step of a systematic analysis of the particle influence, like releasing method, releasing locating, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing ANSYS FLUENT, using Reynolds-averaged Navier-Stokes (RANS) modeling. It is revealed that for this pilot-scale, pressurized burner, velocity profiles of the near-wall region in this POC facility exhibit some discrepancy against the near-wall turbulent flow velocity profile. In order to investigate the particle influence in the near-wall region, particle releasing location will be investigated. Numerical simulation results exhibit the coupling effect of turbulence flow and particles in this case. The particle size also demonstrates a great effect on particle trajectory, then further has an impact on flame stability and temperature.

Li, Lei↗

HANFORD DOUBLE SHELL TANK THERMAL AND SEISMIC PROJECT SEISMIC ANALYSIS OF HANFORD DOUBLE SHELL TANKS

M&D Professional Services, Inc. (M&D) is under subcontract to Pacific Northwest National Laboratories (PNNL) to perform seismic analysis of the Hanford Site Double-Shell Tanks (DSTs) in support of a project entitled Double-Shell Tank (DST) Integrity Project - DST Thermal and Seismic Analyses. The original scope of the project was to complete an up-to-date comprehensive analysis of record of the DST System at Hanford in support of Tri-Party Agreement Milestone M-48-14. The work described herein was performed in support of the seismic analysis of the DSTs. The thermal and operating loads analysis of the DSTs is documented in Rinker et al. (2004). Although Milestone M-48-14 has been met, Revision I is being issued to address external review comments with emphasis on changes in the modeling of anchor bolts connecting the concrete dome and the steel primary tank. The work statement provided to M&D (PNNL 2003) required that a nonlinear soil structure interaction (SSI) analysis be performed on the DSTs. The analysis is required to include the effects of sliding interfaces and fluid sloshing (fluid-structure interaction). SSI analysis has traditionally been treated by frequency domain computer codes such as SHAKE (Schnabel, et al. 1972) and SASSI (Lysmer et al. 1999a). Such frequency domain programs are limited to the analysis of linear systems. Because of the contact surfaces, the response of the DSTs to a seismic event is inherently nonlinear and consequently outside the range of applicability of the linear frequency domain programs. That is, the nonlinear response of the DSTs to seismic excitation requires the use of a time domain code. The capabilities and limitations of the commercial time domain codes ANSYS{reg_sign} and MSC Dytran{reg_sign} for performing seismic SSI analysis of the DSTs and the methodology required to perform the detailed seismic analysis of the DSTs has been addressed in Rinker et al (2006a). On the basis of the results reported in Rinker et al. (2006a), it is concluded that time-domain SSI analysis using ANSYS{reg_sign} is justified for predicting the global response of the DSTs. The most significant difference between the current revision (Revision 1) of this report and the original issue (Revision 0) is the treatment of the anchor bolts that tie the steel dome of the primary tank to the concrete tank dome.

36 MATERIALS SCIENCE↗

ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assesment Neutronics Analysis using the ATTILA Discrete Ordinates Code

Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frequency agile laser safety & hazard analysis for the Sandia Remote Sensing System LIDAR.

A laser safety and hazard analysis was performed for the Raytheon Frequency Agile Laser (FAL) to be used with the Sandia Remote Sensing System (SRSS) B-70 Trailer based on the 2007 version of the American National Standards Institute's (ANSI) Standard 136.1, for Safe Use of Lasers and the 2005 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The B-70 SRSS LIDAR system is a portable platform, which is used to perform laser interaction experiments and tests at various national test sites.

99 GENERAL AND MISCELLANEOUS↗

Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure

A catastrophic failure of the RHIC magnet cooling lines, similar to the LHC superconducting bus failure incident, would pressurize the insulating vacuum in the magnet and transfer line cryostats. Insufficient relief valves on the cryostats could cause a structural failure. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the vacuum cryostat and discharging via the reliefs into the RHIC tunnel, had been developed to calculate the helium pressure inside the cryostat. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces were included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Existing relief valve sizes were reviewed to make sure that the maximum stresses, caused by the calculated maximum pressures inside the cryostats, did not exceed the allowable stresses, based on the ASME Code B31.3 and ANSYS results. The conclusions are as follows: (1) The S/F simulation results show that the highest internal pressure in the cryostats, due to the magnet line failure, is {approx}37 psig (255115 Pa); (2) Based on the simulation, the temperature on the cryostat chamber, INJ Q8-Q9, could drop to 228 K, which is lower than the material minimum design temperature allowed by the Code; (3) Based on the ASME Code and ANSYS results, the reliefs on all the cryostats inside the RHIC tunnel are adequate to protect the vacuum chambers when the magnet cooling lines fail; and (4) In addition to the pressure loading, the thermal deformations, due to the temperature decrease on the cryostat chambers, could also cause a high stress on the chamber, if not properly supported.

43 PARTICLE ACCELERATORS↗

Addressing Control of Hazardous Energy (COHE) Requirements in a Laser Safety Program

OSHA regulation 29CFR1910.147 specifies control of hazardous energy requirements for 'the servicing and maintenance of machines and equipment in which the unexpected energization or start up of the machines or equipment, or release of stored energy could cause injury to employees.' Class 3B and Class 4 laser beams must be considered hazardous energy sources because of the potential for serious eye injury; careful consideration is therefore needed to safely de-energize these lasers. This paper discusses and evaluates control of hazardous energy principles in this OSHA regulation, in ANSI Z136.1 ''Safe Use of Lasers,'' and in ANSI Z244.1 ''Control of Hazardous Energy, Lockout/Tagout and Alternative Methods.'' Recommendations are made for updating and improving CoHE (control of hazardous energy) requirements in these standards for their applicability to safe laser operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗