SEARCH · Search NASA
Results for “BEAM PRODUCTION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Status of the heavy ion beam probe system in the Large Helical Device
A heavy ion beam probe (HIBP) system has been installed into the Large Helical Device (LHD) to measure the spatial profile of the plasma potential and density fluctuations. The optimization of the HIBP system, especially the beam injector, is described. The negative ion beam is required for the MeV beam production in a tandem accelerator. A sputter-type heavy negative ion source has been developed as an intense Au{sup -} beam source to produce Au{sup +} beams with energy in the MeV range. The extraction electrodes and the Einzel lens system of the ion source have been designed taking into account the beam optics, and installed into the real machine. Throughout the plasma diagnostics on LHD experiments, the consumptions of vaporized caesium and gold target are being characterized for practical operations. In addition, the experimental charge fractions are compared with the theoretical fractions for understanding the charge-changing behavior of Au{sup -} ions and optimizing the fraction of Au{sup +} ions at the exit of the tandem accelerator of the HIBP system.
Development of a He{sup 0} Source for Confined Alpha Particle Measurement
A probing He{sup 0} beam for confined alpha particle measurement using a double charge exchange process is now under development. A proof of principle experiment for ground-state He{sup 0} beam production will be performed on a test stand. Several methods are developed to measure the metastable fraction of a He{sup 0} beam. A full-size strong-focusing He{sup +} source has been constructed and sufficient beam current was achieved with a beam size tolerable to be used on ITER.
Development of a He{sup -} and He{sup 0} beam source for alpha particle measurement in a burning plasma
Proof of principle experiments of neutral helium beam production for alpha particle diagnostics was carried out on a test stand. Negative helium ions were produced in the Li charge exchange cell, in which stable and long time operation was possible. He{sup -} beam was accelerated to 157 keV. Finally, He{sup 0} beam was successfully produced after the flight in the drift-tube through the auto-electron-detachment process from He{sup -} to He{sup 0}. A neutral beam detector using a pyroelectric device was also developed to measure He{sup 0} beam intensity. The metastable component in the neutral helium beam was found to be less than 2%.
Neutralized Drift Compression Experiment (NDCX) - II Quarterly Report
LBNL has received American Recovery and Reinvestment Act (ARRA) funding to construct a new accelerator at Lawrence Berkeley National Laboratory (LBNL) to significantly increase the energy on target, which will allow both the Heavy Ion Fusion (HIF) and Warm Dense Matter (WDM) research communities to explore scientific conditions that have not been available in any other device. For NDCX-II, a new induction linear accelerator (linac) will be constructed at Lawrence Berkeley National Laboratory (LBNL). NDCX-II will produce nano-second long ion beam bunches to hit thin foil targets. The final kinetic energy of the ions arriving at the target varies according to the ion mass. For atomic mass unit of 6 or 7 (Lithium ions), useful kinetic energies range from 1.5 to 5 or more MeV. The expected beam charge in the 1 ns (or shorter) pulse is about 20 nanoCoulombs. The pulse repetition rate will be about once or twice per minute (of course, target considerations will often reduce this rate). Our approach to building the NDCX-II ion accelerator is to make use of the available induction modules and 200 kV pulsers from the retired ATA electron linac at LLNL. Reusing this hardware will maximize the ion energy on target at a minimum cost. Some modification of the cells (e.g., reduce the bore diameter and replace with higher field pulsed solenoids) are needed in order to meet the requirements of this project. The NDCX-II project will include the following tasks: (1) Physics design to determine the required ion current density at the ion source, the injector beam optics, the layout of accelerator cells along the beam line, the voltage waveforms for beam acceleration and compression, the solenoid focusing, the neutralized drift compression and the final focus on target; (2) Engineering design and fabrication of the accelerator components, pulsed power system, diagnostic system, and control and data acquisition system; (3) Conventional facilities; and (4) Installation and integration. The project will be considered completed when the accelerator and pulsed power systems are in place and tested, and we begin beam production and acceleration. The period of performance for this project is July 7, 2009 to Mar 31, 2012, and the total funding, including contingency, is $11.0 M.
Surface plasma source with anode layer plasma accelerator
Proposed plasma generation system can be used for high current negative ion beam production and for directed deposition by flux of sputtered neutrals and negative ions. The main mechanism of negative ion formation in surface plasma sources is the secondary emission from low work function surface bombarded by a flux of positive ion or neutrals. The emission of negative ions is enhanced significantly by introducing a small amount of cesium or other substance with low ionization potential. In the proposed source are used positive ions generated by Hall drift plasma accelerator (anode layer plasma accelerator or plasma accelerator with insulated channel, with cylindrical or race track configuration of emission slit). The target-emitter is bombarded by the ion beam accelerated in crossed ExB fields. Negative ions are extracted from the target surface with geometrical focusing and are accelerated by negative voltage applied between emitter and plasma, contacting with the plasma accelerator. Hall drift ion source has a special design with a space for passing of the emitted negative ions and sputtered particles through the positive ion source.
Neutron Imaging and Applications
Neutron Imaging and Applications offers an introduction to the basics of neutron beam production and instrumentation in addition to the wide scope of techniques that provide unique imaging capabilities over a broad and diverse range of applications. An instructional overview of neutron sources, optics and detectors, allows readers to delve more deeply into the discussions of radiography, tomography, phase contrast imaging and prospective applications using advanced neutron holography techniques and polarized beams. A section devoted to overviews in a growing range of applications describes imaging of fuel cells and hydrogen storage devices for a robust hydrogen economy; new directions in material science and engineering; the investigation of precious artifacts of cultural heritage importance; determination of plant physiology and growth processes; imaging of biological tissues and macromolecules, and the practical elements of neutron imaging for homeland security and contraband detection. Written by key experts in the field, researchers and engineers involved with imaging technologies will find Neutron Imaging and Applications a valuable reference.
Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac
Purpose: A linac delivering intensity-modulated radiotherapy (IMRT) can benefit from a flattening filter free (FFF) design which offers higher dose rates and reduced accelerator head scatter than for conventional (flattened) delivery. This reduction in scatter simplifies beam modeling, and combining a Monte Carlo dose engine with a FFF accelerator could potentially increase dose calculation accuracy. The objective of this work was to model a FFF machine using an adapted version of a previously published virtual source model (VSM) for Monte Carlo calculations and to verify its accuracy. Methods: An Elekta Synergy linear accelerator operating at 6 MV has been modified to enable irradiation both with and without the flattening filter (FF). The VSM has been incorporated into a commercially available treatment planning system (Monaco Trade-Mark-Sign v 3.1) as VSM 1.6. Dosimetric data were measured to commission the treatment planning system (TPS) and the VSM adapted to account for the lack of angular differential absorption and general beam hardening. The model was then tested using standard water phantom measurements and also by creating IMRT plans for a range of clinical cases. Results: The results show that the VSM implementation handles the FFF beams very well, with an uncertainty between measurement and calculation of <1% which is comparable to conventional flattened beams. All IMRT beams passed standard quality assurance tests with >95% of all points passing gamma analysis ({gamma} < 1) using a 3%/3 mm tolerance. Conclusions: The virtual source model for flattened beams was successfully adapted to a flattening filter free beam production. Water phantom and patient specific QA measurements show excellent results, and comparisons of IMRT plans generated in conventional and FFF mode are underway to assess dosimetric uncertainties and possible improvements in dose calculation and delivery.
Operational Experience with the Nb/Pb SRF Photoelectron Gun
SRF photoelectron guns offer the promise of high brightness, high average current beam production for the next generation of accelerator driven light sources such as free electron lasers, THz radiation sources or energy-recovery linac driven synchrotron radiation sources. In a first step a fully superconducting RF (SRF) photoelectron gun is under development by a collaboration between HZB, DESY, JLAB, BNL and NCBJ. The aim of the experiment is to understand and improve the performance of a Nb SRF gun cavity coated with a small metallic Pb cathode film on the cavity backplane. This paper describes the highlights from the commissioning and beam parameter measurements. The main focus is on lessons learned from operation of the SRF gun.
First results of the 2.45 GHz Oshima electron cyclotron resonance ion source
A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.
Observation of impurity free monoenergetic proton beams from the interaction of a CO{sub 2} laser with a gaseous target
A monoenergetic proton beam is observed from the interaction of a short-pulse infrared ({lambda} = 10.6 {mu}m) laser at intensity I = 6 x 10{sup 15} W cm{sup -2} with a gas jet target. The proton beam is found to have narrow energy spread ({approx} 4% ), high spectral brightness ({approx} 10{sup 12} protons/MeV/sr), low normalized emittance ({epsilon}{sub n{approx_equal}} 8 nm rad), and high contrast (> 200 x over noise). The narrow energy spread and low levels of impurity makes this method an interesting route for high-repetition rate high quality proton beam production.
Range, resolution and power of THz systems for remote detection of concealed radioactive materials
This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.
A status report of the multipurpose superconducting electron cyclotron resonance ion source (invited)
Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 10{sup 13} cm{sup -3} and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate plasma trap, with a B-minimum shape, according to the high B mode concept [S. Gammino and G. Ciavola, Plasma Sources Sci. Technol. 5, 19 (1996)]. The MS-ECRIS ion source has been designed following this concept and its construction is underway at GSI, Darmstadt. The project is the result of the cooperation of nine European institutions with the partial funding of EU through the sixth Framework Programme. The contribution of different institutions has permitted to build in 2006-2007 each component at high level of expertise. The description of the major components will be given in the following with a view on the planning of the assembly and commissioning phase to be carried out in fall 2007. An outline of the experiments to be done with the MS-ECRIS source in the next two years will be presented.
Secondary particle production from laser accelerated beams
3-MeV protons and fusion neutrons are generated by focused radiation of the 3-TW Prague Asterix Laser System (PALS). 30-mA current of 3-MeV protons is detected behind the target in the forward direction when a hydrogenated silicon foil is used. The co-occurrence of bursts in the emission of ions and fusion neutrons from CD{sub 2} plasma is observed. The energy of produced deuteron bursts is high enough to drive deuterium fusion in CD{sub 2} catcher targets.
Improved ion containment using a ring-cusp ion thruster
A 30-centimeter diameter ring-cusp ion thruster is described which operates at inert gas ion beam currents up to about 7 ampere, with significant improvements in discharge chamber performance over conventional divergent-field thrusters. The thruster has strong boundary ring-cusp magnetic fields, a diverging field on the cathode region, and a nearly field-free volume upstream of the ion extraction system. Minimum ion beam production costs of 90 to 100 watts per beam ampere (W/A) were obtained for argon, krypton and xenon. Propellant efficiencies in excess of 0.90 were achieved at 100 to 120 W/A for the three inert gases. The ion beam charge-state was documented with a collimating mass spectrometer probe to allow evaluation of overall thruster efficiencies.
CHARACTERIZATION OF RADIATION DAMAGES TO POSITRON SOURCE MATERIALS
The secondary beam production target at future positron sources at the Continuous Electron Beam Accelerator Facility (CEBAF), the International Linear Collider (ILC) or the Future Circular Collider (FCC), features unprecedented mechanical and thermal stresses which may compromise sustainable and reliable operation. Candidate materials are required to possess high melting temperature together with excellent thermal conductivity, elasticity and radiation hardness properties. In order to substantiate the material choice for the CEBAF and ILC positron sources, the response of candidate materials such as titanium alloys, tungsten, and tantalum to electron beam irradiation was experimentally investigated. CEBAF and ILC expected operating conditions were mimicked using the 3.5 MeV electron beam of the MAMI facility injector. The material degradations were precisely analyzed via high energy X-ray diffraction at the HEMS beamline operated by the Helmholtz-Zentrum Hereon at the PETRA III synchrotron facility. This work reports the results of these measurements and their interpretation.
Status and Plans for the Accelerator Working Group of the International Design Study of the Neutrino Factory
The purpose of the International Design Study of the Neutrino Factory (IDS-NF) is to produce a design report for a neutrino factory in 2013. I report the status of the accelerator design and plans for future studies.