Search NASA⌕ Search

SEARCH · Search NASA

Results for “Constraint Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Emissions Implications of Future Natural Gas Production and Use in the U.S. and in the Rocky Mountain Region

Enhanced prospects for natural gas production raise questions about the balance of impacts on air quality, as increased emissions from production activities are considered alongside the reductions expected when natural gas is burned in place of other fossil fuels. This study explores how trends in natural gas production over the coming decades might affect emissions of greenhouse gases (GHG), volatile organic compounds (VOCs) and nitrogen oxides (NOx) for the United States and its Rocky Mountain region. The MARKAL (MARKet ALlocation) energy system optimization model is used with the U.S. Environmental Protection Agency's nine-region database to compare scenarios for natural gas supply and demand, constraints on the electricity generation mix, and GHG emissions fees. Through 2050, total energy system GHG emissions show little response to natural gas supply assumptions, due to offsetting changes across sectors. Policy-driven constraints or emissions fees are needed to achieve net reductions. In most scenarios, wind is a less expensive source of new electricity supplies in the Rocky Mountain region than natural gas. U.S. NOx emissions decline in all the scenarios considered. Increased VOC emissions from natural gas production offset part of the anticipated reductions from the transportation sector, especially in the Rocky Mountain region.

emissions↗

Limited-constraint WAAM fixture for hybrid manufacturing

This paper describes a limited-constraint alternative to the traditional over-constrained build plate clamping in metal additive manufacturing. A fixture design is presented that enables build plate thermal growth within its plane while restricting deformation perpendicular to that plane. A prototype fixture is designed, fabricated, and tested for wire arc additive manufacturing (WAAM). Experimental results are presented for depositing 1.2 mm diameter 5356 aluminum wire on a 5052 aluminum build plate. The build plate deformation is measured for various clamping torques and a 77.3% reduction in distortion is achieved using the limited-constraint approach with identical WAAM parameters.

36 MATERIALS SCIENCE↗

Emergent constraints on future methane emissions from global wetlands

Future methane (CH 4 ) emissions from natural wetlands are predicted to increase due to global warming, leading to positive feedback on climate change. However, the magnitude of this increase remains highly uncertain. Here we present novel ensemble simulations of seven state-of-the-art terrestrial biosphere models to estimate wetland CH 4 emissions (eCH 4 ) during the twenty-first century. Our estimates suggest that for every 1 °C increase in global land surface temperature, there is a 24 ± 10 Tg CH 4 yr −1 increase in eCH 4 . We also identify an emergent relationship between contemporary temperature dependence and projected eCH 4 . When constrained by 163 site-year eddy-covariance measurements of eCH 4 , we show that wetland emissions can increase by 50–60% by the 2090s relative to the 2010s under a high-warming scenario. The projected decadal increase in eCH 4 from the 2010–2019 baseline to the 2030s would very likely (90% probability) offset an amount equivalent in scale to 8–10% of anthropogenic eCH 4 at the 2020 level, comparable to the reductions committed under the Global Methane Pledge. However, the constraint is dominated by mid- and high-latitude observations, with limited tropical coverage, and uncertainties in projected wetland inundation contribute substantially to uncertainty in eCH 4 . Our findings reduce the uncertainty in projected wetland methane–climate feedback and highlight its potential impacts on methane mitigation efforts to slow global warming.

Zhang, Zhen [Chinese Academy of Sciences (CAS), Be↗

Enforcing constraints for time series prediction in supervised, unsupervised and reinforcement learning

We assume that we are given a time series of data from a dynamical system and our task is to learn the flow map of the dynamical system. We present a collection of results on how to enforce constraints coming from the dynamical system in order to accelerate the training of deep neural networks to represent the flow map of the system as well as increase their predictive ability. In particular, we provide ways to enforce constraints during training for all three major modes of learning, namely supervised, unsupervised and reinforcement learning. In general, the dynamic constraints need to include terms which are analogous to memory terms in model reduction formalisms. Such memory terms act as a restoring force which corrects the errors committed by the learned flow map during prediction. For supervised learning, the constraints are added to the objective function. For the case of unsupervised learning, in particular generative adversarial networks, the constraints are introduced by augmenting the input of the discriminator. Finally, for the case of reinforcement learning and in particular actor-critic methods, the constraints are added to the reward function. In addition, for the reinforcement learning case, we present a novel approach based on homotopy of the action-value function in order to stabilize and accelerate training. We use numerical results for the Lorenz system to illustrate the various constructions.

Stinis, Panagiotis↗

Chameleon fragmentation

A scalar field dark energy candidate could couple to ordinary matter and photons, enabling its detection in laboratory experiments. Here we study the quantum properties of the chameleon field, one such dark energy candidate, in an ''afterglow'' experiment designed to produce, trap, and detect chameleon particles. In particular, we investigate the possible fragmentation of a beam of chameleon particles into multiple particle states due to the highly non-linear interaction terms in the chameleon Lagrangian. Fragmentation could weaken the constraints of an afterglow experiment by reducing the energy of the regenerated photons, but this energy reduction also provides a unique signature which could be detected by a properly-designed experiment. We show that constraints from the CHASE experiment are essentially unaffected by fragmentation for φ{sup 4} and 1/φ potentials, but are weakened for steeper potentials, and we discuss possible future afterglow experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing green infrastructure placement under precipitation uncertainty

Increased urbanization, infrastructure degradation, and climate change threaten to overwhelm stormwater systems across the nation, rendering them ineffective. Green Infrastructure (GI) practices are low cost, low regret strategies that can contribute to urban runoff management. However, questions remain as to how to best distribute GI practices through urban watersheds given precipitation uncertainty and the variable hydrological responses to them. We develop stochastic programming models to determine the optimal placement of GI practices across a set of candidate locations in a watershed to minimize the total expected runoff under medium-term precipitation uncertainties. Specifically, we first develop a two-stage stochastic programming model. Next, we reformulate this model using perturbed parameters to reduce the requisite computational time and extend it to multi-stage. In addition, we introduce constraints that allow for incorporating sub-catchment-level runoff reduction considerations. Furthermore, we account for hydrological connectivity in the watershed using an underlying acyclic connectivity graph of sub-catchments and incorporate various practical considerations into the models. In addition, we develop a systemic approach to downscale the existing daily precipitation projections into hourly units and efficiently estimate the corresponding hydrological responses. These advancements are brought together in a case study for an urban watershed in a mid-sized city in the U.S., where we perform sensitivity analyses, evaluate the importance of the considered constraints, and provide insights.

54 ENVIRONMENTAL SCIENCES↗

Survey of techniques for reduction of wind turbine blade trailing edge noise.

Aerodynamic noise from wind turbine rotors leads to constraints in both rotor design and turbine siting. The primary source of aerodynamic noise on wind turbine rotors is the interaction of turbulent boundary layers on the blades with the blade trailing edges. This report surveys concepts that have been proposed for trailing edge noise reduction, with emphasis on concepts that have been tested at either sub-scale or full-scale. These concepts include trailing edge serrations, low-noise airfoil designs, trailing edge brushes, and porous trailing edges. The demonstrated noise reductions of these concepts are cited, along with their impacts on aerodynamic performance. An assessment is made of future research opportunities in trailing edge noise reduction for wind turbine rotors.

17 WIND ENERGY↗

A novel conditional formulation of the Vlasov–Ampère equations: a conservative, positivity, asymptotic and Gauss law preserving scheme

We propose a novel reformulation of the Vlasov–Ampère equations for plasmas that reveals discrete symmetries that enables simultaneous conservation of mass, momentum and energy; preservation of Gauss’s law; positivity of the distribution function; and consistency with quasi-neutral asymptotics. The approach employs variable and coordinate transformations to yield a coupled system comprising a modified Vlasov equation and associated moment–field equations. The modified Vlasov equation advances a conditional distribution function that excludes mass, momentum and energy densities, which are instead evolved through moment equations enforcing the relevant symmetries, conservation laws and involution constraints. This reformulation aligns naturally with a recent slow-manifold reduction technique, which separates fast electron time scales and simplifies the treatment of the quasi-neutral limit within the reduced moment–field subsystem. Using this framework, we develop a numerical method for the reduced 1D1V subsystem that, for the first time in the literature, satisfies all key physical constraints while maintaining a quasi-neutral asymptotic behaviour. The advantages of the method are demonstrated on canonical electrostatic test problems, including the multiscale ion acoustic shock wave.

1D1V↗

Compensator models for fluence field modulated computed tomography

Purpose: Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This work aims to compare the relative effectiveness of FFMCT applied to different thoracic imaging tasks (routine diagnostic CT, lung cancer screening, and cardiac CT) when the modulator is subject to limiting constraints, such as might be present in realistic implementations.Methods: An image quality plan was defined for a simulated anthropomorphic chest slice, including regions of high and low image quality, for each of the thoracic imaging tasks. Modulated fluence patterns were generated using a simulated annealing optimization script, which attempts to achieve the image quality plan under a global dosimetric constraint. Optimization was repeated under different types of modulation constraints (e.g., fixed or gantry angle dependent patterns, continuous or comprised of discrete apertures) with the most limiting case being a fixed conventional bowtie filter. For each thoracic imaging task, an image quality map (IQM{sub sd}) representing the regionally varying standard deviation is predicted for each modulation method and compared to the prescribed image quality plan as well as against results from uniform fluence fields. Relative integral dose measures were also compared.Results: Each IQM{sub sd} resulting from FFMCT showed improved agreement with planned objectives compared to those from uniform fluence fields for all cases. Dynamically changing modulation patterns yielded better uniformity, improved image quality, and lower dose compared to fixed filter patterns with optimized tube current. For the latter fixed filter cases, the optimal choice of tube current modulation was found to depend heavily on the task. Average integral dose reduction compared to a uniform fluence field ranged from 10% using a bowtie filter to 40% or greater using an idealized modulator.Conclusions: The results support that FFMCT may achieve regionally varying image quality distributions in good agreement with user-prescribed values, while limiting dose. The imposition of constraints inhibits dose reduction capacity and agreement with image quality plans but still yields significant improvement over what is afforded by conventional dose minimization techniques. These results suggest that FFMCT can be implemented effectively even when the modulator has limited modulation capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical Application of High-Dose, Image-Guided Intensity-Modulated Radiotherapy in High-Risk Prostate Cancer

Purpose: To report the feasibility and early toxicity of dose-escalated image-guided IMRT to the pelvic lymph nodes (LN), prostate (P), and seminal vesicles (SV). Methods and Materials: A total of 103 high-risk prostate cancer patients received two-phase, dose-escalated, image-guided IMRT with 3 years of androgen deprivation therapy. Clinical target volumes (CTVs) were delineated using computed tomography/magnetic resonance co-registration and included the prostate, portions of the SV, and the LN. Planning target volume margins (PTV) used were as follows: P (10 mm, 7 mm posteriorly), SV (10 mm), and LN (5 mm). Organs at risk (OaR) were the rectal and bladder walls, femoral heads, and large and small bowel. The IMRT was planned with an intended dose of 55.1 Gy in 29 fractions to all CTVs (Phase 1), with P+SV consecutive boost of 24.7 Gy in 13 fractions. Daily online image guidance was performed using bony landmarks and intraprostatic markers. Feasibility criteria included delivery of intended doses in 80% of patients, 95% of CTV displacements incorporated within PTV during Phase 1, and acute toxicity rate comparable to that of lower-dose pelvic techniques. Results: A total of 91 patients (88%) received the total prescription dose. All patients received at least 72 Gy. In Phase 1, 63 patients (61%) received the intended 55.1 Gy, whereas 87% of patients received at least 50 Gy. Dose reductions were caused by small bowel and rectal wall constraints. All CTVs received the planned dose in >95% of treatment fractions. There were no Radiation Therapy Oncology Group acute toxicities greater than Grade 3, although there were five incidences equivalent to Grade 3 within a median follow-up of 23 months. Conclusion: These results suggest that dose escalation to the PLN+P+SV using IMRT is feasible, with acceptable rates of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy for Prostate Cancer: A Comparison of Four Consensus Guidelines and Dosimetric Evaluation of 3D-CRT Versus Tomotherapy IMRT

Purpose: Despite the benefits of adjuvant radiotherapy after radical prostatectomy, approximately one-half of patients relapse. Four consensus guidelines have been published (European Organization for Research and Treatment of Cancer, Faculty of Radiation Oncology Genito-Urinary Group, Princess Margaret Hospital, Radiation Therapy Oncology Group) with the aim of standardizing the clinical target volume (CTV) delineation and improve outcomes. To date, no attempt has been made to compare these guidelines in terms of treatment volumes or organ at risk (OAR) irradiation. The extent to which the guideline-derived plans meet the dosimetric constraints of present trials or of the Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) trial is also unknown. Our study also explored the dosimetric benefits of intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients treated with postoperative RT were included. The three-dimensional conformal radiotherapy (3D-CRT) plans were applied to cover the guideline-generated planning target volumes (66 Gy in 33 fractions). Dose-volume histograms (DVHs) were analyzed for CTV/planning target volume coverage and to evaluate OAR irradiation. The OAR DVHs were compared with the constraints proposed in the QUANTEC and Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trials. 3D-CRT plans were compared with the tomotherapy plans for the Radiation Therapy Oncology Group planning target volume to evaluate the advantages of IMRT. Results: The CTV differed significantly between guidelines (p < 0.001). The European Organization for Research and Treatment of Cancer-CTVs were significantly smaller than the other CTVs (p < 0.001). Differences in prostate bed coverage superiorly accounted for the major volumetric differences between the guidelines. Using 3D-CRT, the DVHs rarely met the QUANTEC or RADICALS rectal constraints, independent of the guideline used. The RADICALS bladder constraints were met most often by the European Organization for Research and Treatment of Cancer consensus guideline (14 of 20). The tomotherapy IMRT plans resulted in significant OAR sparing compared with the 3D-CRT plans; however, the RADICALS and QUANTEC criteria were still missed in a large percentage of cases. Conclusion: Treatment volumes using the current consensus guidelines differ significantly. For the four CTV guidelines, the rectal and bladder DVH constraints proposed in the QUANTEC and RADICALS trials are rarely met with 3D-CRT. IMRT results in significant OAR sparing; however, the RADICALS dose constraints are still missed for a large percentage of cases. The rectal and bladder constraints of RADICALS should be modified to avoid a reduction in the CTVs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DETECTION OF SIGNALS FROM COSMIC REIONIZATION USING RADIO INTERFEROMETRIC SIGNAL PROCESSING

Observations of the H I 21 cm transition line promises to be an important probe into the cosmic dark ages and epoch of reionization. One of the challenges for the detection of this signal is the accuracy of the foreground source removal. This paper investigates the extragalactic point source contamination and how accurately the bright sources (approx>1 Jy) should be removed in order to reach the desired rms noise and be able to detect the 21 cm transition line. Here, we consider position and flux errors in the global sky model for these bright sources as well as the frequency independent residual calibration errors. The synthesized beam is the only frequency dependent term included here. This work determines the level of accuracy for the calibration and source removal schemes and puts forward constraints for the design of the cosmic reionization data reduction scheme for the upcoming low frequency arrays such as, Murchison Widefield Array, Precision Array to Probe Epoch of Reionization, etc. We show that in order to detect the reionization signal the bright sources need to be removed from the data sets with a positional accuracy of approx0.1 arcsec. Our results also demonstrate that the efficient foreground source removal strategies can only tolerate a frequency independent antenna based mean residual calibration error of approx<0.2% in amplitude or approx<0.{sup 0}2 in phase, if they are constant over each days of observations (6 hr). In future papers, we will extend this analysis to the power-spectral domain and also include the frequency-dependent calibration errors and direction-dependent errors (ionosphere, primary beam, etc.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology for Clustering High-Resolution Spatiotemporal Solar Resource Data

In this report, we introduce a methodology to achieve multiple levels of spatial resolution reduction of solar resource data, with minimal impact on data variability, for use in energy systems modeling. The selection of an appropriate clustering algorithm, parameter selection including cluster size, methods of temporal data segmentation, and methods of cluster evaluation are explored in the context of a repeatable process. In describing this process, we illustrate the steps in creating a reduced resolution, but still viable, dataset to support energy systems modeling, e.g. capacity expansion or production cost modeling. This process is demonstrated through the use of a solar resource dataset; however, the methods are applicable to other resource data represented through spatiotemporal grids, including wind data. In addition to energy modeling, the techniques demonstrated in this paper can be used in a novel top-down approach to assess renewable resources within many other contexts that leverage variability in resource data but require reduction in spatial resolution to accommodate modeling or computing constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational and Mission Highlights A Monthly Summary of Top Achievements September 2020

In August 2020, transuranic (TRU) waste inventory onsite at TA-55 fell below 1,500 containers. Multiple groups within the Associate Laboratory Directorate for Weapons Production (ALDWP) have worked collaboratively to achieve this reduction in waste and residue inventory, all within the constraints of COVID-19 safety requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concentrated radiative cooling and its constraint from reciprocity

Concentrated radiative cooling, an analogous concept of the concentrated solar power technology, has the potential of amplifying both the cooling power and the temperature reduction. However, concentrators have not yet been systematically optimized. Moreover, a widely used theoretical approach to analyze such systems has neglected a fundamental constraint from reciprocity, which can lead to an overestimate of cooling performance and unclarified limits of amplification factors. Here we develop a theoretical framework addressing these shortcomings. Modeling suggests the optimized shape and geometric dimensions of concentrators, as well as the limiting cooling power and temperature reduction. Using an electroplated Al 2 O 3 emitter and an optimized conical concentrator, we experimentally amplify the nighttime radiative cooling by 26%.

Dong, Minghao↗

Hadronic contributions to (g - 2) µ

The Muon g-2 Experiment at Fermilab, which recently started running, plans to reduce the uncertain- ties on the already very precisely measured anomalous magnetic moment of the muon by a factor of four. The goal of this effort is to probe the observed difference of more than three standard deviations between Standard-Model theory and experiment, one of the few persistent hints for physics beyond the Standard Model. The Fermilab experiment collected data from their first run last year with statistics comparable to BNL E821. They expect to release the measurement result in 2019. On the theoretical side, because the muon g - 2 arises from quantum- mechanical loop contributions in the Standard Model, it is sensitive to virtual effects of new particles, and places important constraints on Standard-Model extensions. To leverage the anticipated reduction in experimental errors, and determine unambiguously whether or not new-physics effects contribute to this quantity, the theoretical errors must be made more reliable and reduced to a commensurate precision. The Muon g-2 Theory Initiative was created to facilitate this development. The dominant sources of uncertainty in the Standard-Model prediction of the muon g -2 are from the hadronic contributions. The hadronic vacuum polarization (HVP) provides the leading correction followed by hadronic light-by-light (HLbL) scattering. There are a number of complementary theoretical efforts underway to better understand and quantify these contributions, including dispersive and data driven methods, lattice QCD, and effective field theories. Given the precision goals and the phenomenological importance, it is important to have more than one independent method for each of the two hadronic corrections, each with fully quantified uncertainties. Fostering the development of such methods is a prime goal of the initiative, as this will enable critical cross checks, and, upon combination, may yield gains in precision, to maximize the impact of E989. An important aspect of the Muon g-2 Theory Initiative’s activities are providing platforms that facilitate interactions between the different groups, as well as between the theoretical and experimental g - 2 communities. To this end, several workshops were organized in 2017 and 2018. The first meeting, held at Fermilab (June 3–6, 2017, St. Charles, IL, USA), served to kick-off the Initiative’s activities. Two meetings in early 2018 were focused respectively on the HVP and HLbL corrections. The HVP meeting was held at KEK (February 12–14, 2018, Tsukuba, Japan) and the HLbL meeting at the University of Connecticut (March 12–14, 2018, Storrs, CT, USA). The most recent workshop, which served as the second plenary meeting of the Initiative, was held at the University of Mainz (June 18–22, 2018, Mainz, Germany). An important outcome of these meetings are concrete plans for a first white paper, which is currently being written. We aim to post the white paper just prior to the release of the first E989 measurement, to present a clean theoretical prediction. The first white paper is focused on assessing and improving the reliability of the SM prediction. The purpose of the INT workshop in September 2019 is to start the next stage of the Initiative, focusing on the development of strategies to improve the theory uncertainties beyond the current level towards the E989 precision goal. We aim to accelerate theoretical developments on the hadronic contributions to the muon g - 2 so that the Standard-Model theory error can be brought to the needed precision, again in advance of the next release from E989. Hence the workshop will provide crucial theory support for a US experiment with broad impact. The Muon g-2 Theory Initiative relies on input from representatives of all the different communities that are engaged in this effort. It is therefore important that all these areas are properly represented. The funds from this grant will be used to enable more people, especially early-career scientists, to participate and make essential contributions to the workshop discussions. Since the workshop’s main goal is to kick-off the next stage of the theory initiative’s activities, support for this workshop from the DOE will help the theory community provide crucial theoretical support to the Fermilab Muon g-2 Experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-AB-303-01: A Feasibility Study for Dynamic Adaptive Therapy of Non-Small Cell Lung Cancer

Purpose: To compare plans for NSCLC optimized using Dynamic Adaptive Therapy (DAT) with conventional IMRT optimization. DAT adapts plans based on changes in the target volume by using dynamic programing techniques to consider expected changes into the optimization process. Information gathered during treatment, e.g. from CBCT, is incorporated into the optimization. Methods and materials: DAT is formulated using stochastic control formalism, which minimizes the total expected number of tumor cells at the end of a treatment course subject to uncertainty inherent in the tumor response and organs-at-risk (OAR) dose constraints. This formulation allows for non-stationary dose distribution as well as non-stationary fractional dose as needed to achieve a series of optimal plans that are conformal to tumor over time. Sixteen phantom cases with various sizes and locations of tumors, and OAR geometries were generated. Each case was planned with DAT and conventional IMRT (60Gy/30fx). Tumor volume change over time was obtained by using, daily MVCT-based, two-level cell population model. Monte Carlo simulations have been performed for each treatment course to account for uncertainty in tumor response. Same OAR dose constraints were applied for both methods. The frequency of plan modification was varied to 1, 2, 5 (weekly), and 29 (daily). The final average tumor dose and OAR doses have been compared to quantify the potential benefit of DAT. Results: The average tumor max, min, mean, and D95 resulted from DAT were 124.0–125.2%, 102.1–114.7%, 113.7–123.4%, and 102.0–115.9% (range dependent on the frequency of plan modification) of those from conventional IMRT. Cord max, esophagus max, lung mean, heart mean, and unspecified tissue D05 resulted from AT were 84–102.4%, 99.8–106.9%, 66.9–85.6%, 58.2–78.8%, and 85.2–94.0% of those from conventional IMRT. Conclusions: Significant tumor dose increase and OAR dose reduction, especially with parallel OAR with mean or dose-volume constraints, can be achieved using DAT.

60 APPLIED LIFE SCIENCES↗

Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗