Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Analysis and Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimisation of the Kaplan hydropower system via PID 2 and digital twin

Here, this paper proposes a proportional–integral-double–derivative (PID 2 ) optimisation method for the Kaplan hydropower system by building a digital twin. The study first uses one multilayer perceptron (MLP) to model the hydroturbine dynamic and then adopts three connected MLPs to model the generator dynamic, both in an open-loop fashion. Inspired by stochastic distribution control (SDC) theory, we regard the training of the turbine's neural network model as a process control problem, and we propose minimising entropy loss to update the network parameters. The next step is to build the digital twin by connecting the neural network models with a PID 2 controller and a lead-lag exciter and run the whole model in a closed-loop fashion. After that, a binary search approach is applied to optimise the PID 2 parameters based on the obtained digital twin model. The simulation results show that the proposed method can reduce the mean square tracking error by more than 90%. Furthermore, the method is extended to jointly optimise the PID 2 controller and excitation system gains through multiobjective optimisation, leveraging Pareto frontier analysis to balance active power and voltage tracking performance. Simulation results confirm the effectiveness of the proposed method, achieving a 83.46% reduction in relative mean square error of active power, a 47.13% reduction in terminal voltage tracking error, and an 82.78% improvement in the overall scalarized objective.

Hydropower system↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Simultaneous optimal system and controller design for multibody systems with joint friction using direct sensitivities

Abstract Real-world multibody systems are often subject to phenomena like friction, joint clearances, and external events. These phenomena can significantly impact the optimal design of the system and its controller. This work addresses the gradient-based optimization methodology for multibody dynamic systems with joint friction using a direct sensitivity approach. The Brown–McPhee model has been used to characterize the joint friction in the system. This model is suitable for the study due to its accuracy for dynamic simulation and its compatibility with sensitivity analysis. This novel methodology supports codesign of the multibody system and its controller, which is especially relevant for applications like robotics and servo-mechanical systems, where the actuation and design are highly dependent on each other. Numerical results are obtained using a software package written in Julia with state-of-the-art libraries for automatic differentiation and differential equations. Three case studies are provided to demonstrate the attractive properties of simultaneous optimal design and control approach for certain applications.

Verulkar, Adwait↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

Poromechanical cohesive interface element with combined Mode I-II cohesive zone elastoplasticity for simulating fracture in fluid-saturated porous media

A combined Mode I-II cohesive zone (CZ) elasto-plastic constitutive model, and a two-dimensional (2D) cohesive interface element (CIE) are formulated and implemented at small strain within an ABAQUS User Element (UEL) for simulating 2D crack nucleation and propagation in fluid-saturated porous media. Here, the CZ model mitigates problems of convergence for the global Newton-Raphson solver within ABAQUS, which when combined with a viscous stabilization procedure allows for simulation of post-peak response under load control for coupled poromechanical finite element analysis, such as concrete gravity dam stability analysis. Verification examples are presented, along with a more complex ambient limestone-concrete wedge fracture experiment, water-pressurized concrete wedge experiment, and concrete gravity dam stability analyses. A calibration procedure for estimating the CZ parameters is demonstrated with the limestone-concrete wedge fracture process. For the water-pressurized concrete wedge fracture experiment it is shown that the inherent time-dependence of the poromechanical CIE analysis provides a good match with experimental force versus displacement results at various crack mouth opening rates, yet misses the pore water pressure evolution ahead of the crack tip propagation. This is likely a result of the concrete being partially-saturated in the experiment, whereas the finite element analysis assumes fully water saturated concrete. For the concrete gravity dam analysis, it is shown that base crack opening and associated water uplift pressure leads to a reduced Factor of Safety, which is confirmed by separate analytical calculations.

97 MATHEMATICS AND COMPUTING↗

Comparison of edge turbulence characteristics between DIII-D and C-Mod simulations with XGC1

The physical processes taking place at the separatrix and scrape-off layer regions are crucial for the operation of tokamaks as they govern the interaction of hot plasma with the vessel walls. Numerical modeling of the edge with state-of-the-art codes attempts to elucidate the complex interactions between neoclassical drifts, turbulence, poloidal and parallel flows that control the physical set-up of the SOL region. Here, we present post-processing analysis of simulation results from the gyrokinetic code XGC1, comparing and contrasting edge turbulence characteristics from a simulation of the DIII-D tokamak against a simulation of the Alcator C-Mod tokamak. We find that the equilibrium ExB flux across the separatrix has a similar poloidal pattern in both discharges which can be explained by rB-drifts and trapped ion excursions. Furthermore, collisionality is noted to play a major role in the way that it prevents local charge accumulations from having more global effects in the C-Mod case. In both cases, turbulent electron heat flux is observed to be higher than the ion one and is possibly related to the need of electrons to maintain quasineutrality through the only channel available to them for exiting the confinement. By Fourier analysis, we identify turbulent frequencies and growth rates of the dominant mode in both simulations. In the case of C-Mod, these numbers point to the presence of a drift wave. In the DIII-D case, further linear simulations with the Gene code reveal a trapped electron mode. Furthermore, using a blob detection and tracking tool, we present the amplitude and size distributions of the blobs from both simulations. The amplitude distributions are in qualitative agreement with experimental observations while the size distributions are consistent with the fact that most of the blobs are not connecting to the divertor plates and suggest that they are generated by the shearing of the turbulent modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interpreting internal consistency of DES measurements

ABSTRACT Bayesian evidence ratios are widely used to quantify the statistical consistency between different experiments. However, since the evidence ratio is prior dependent, the precise translation between its value and the degree of concordance/discordance requires additional information. The most commonly adopted metric, the Jeffreys scale, can falsely suggest agreement between data sets when priors are chosen to be sufficiently wide. This work examines evidence ratios in a DES-Y1 simulated analysis, focusing on the internal consistency between weak lensing and galaxy clustering. We study two scenarios using simulated data in controlled experiments. First, we calibrate the expected evidence ratio distribution given noise realizations around the best-fitting DES-Y1 ΛCDM cosmology. Secondly, we show the behaviour of evidence ratios for noiseless fiducial data vectors simulated using a modified gravity model, which generates internal tension in the LCDM analysis. We find that the evidence ratio of noise realizations generated at all confidence levels was biased towards agreement and show, with a modified gravity model, that the choice of prior could conceal the discrepancies between weak lensing and galaxy clustering induced by prior effects in unlike cosmological models, concluding that the evidence ratio in a DES-Y1 study is, indeed, biased towards agreement. Boundary effects can also influence conclusions about the inconsistency induced by modified gravity, even in a noiseless data vector simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control-Oriented Modeling of Cycle-to-Cycle Combustion Variability at the Misfire Limit in SI Engines

A control-oriented model is presented that can capture the prior-cycle correlation of combustion cycles during conditions with high levels of exhaust gas recirculation (EGR). Combustion events are modeled in discrete time and the dynamic evolution is captured by the residual air, fuel, and inert gas trapped in the combustion chamber. The mathematical formulation of the model is presented together with the calibration procedure to emulate a particular engine operating condition. A cycle-to-cycle system identification methodology is described which allows regressing model parameters from experimental data. Simulations are presented and compared to real engine measurements to show the modeling potential for analysis and control of combustion events.

Maldonado Puente, Bryan↗

Multibody for Everybody (M4E): A Symbolic Dynamics Modeling Tool with Applications in Simulation, Control, and Optimization

Developing the analytical model of a multibody system is often the initial step in control and optimization. The analytical model (equations of motion) describes a system’s time evolution under specified forcing conditions. Although developing these equations is easy for simple systems, this process becomes more complex for systems composed of multiple bodies. Deriving equations of motion for complex multibody systems requires specialized expertise in multibody dynamics, is time-consuming, and is susceptible to error. To address this issue, this paper presents an open-source, easy-to-use, systematic framework to derive symbolic equations of motion in both Python and MATLAB using the joint coordinate formulation. This formulation results in a set of ordinary differential equations that use the minimum set of coordinates needed to model a system. The symbolic representation provides better insight into the influence of design parameters on system performance, facilitates sensitivity analysis and parameter studies, and supports direct implementation of control and optimization routines. The tool enables numerical simulation for specified parameter sets, is modular for straightforward integration with other tools and libraries, and allows incorporation of hydrodynamics, mooring, and other external forces. The result is a reproducible, extensible pipeline for modeling, simulation, and design of complex multibody systems. The proposed tool is versatile and can be applied to domains such as robotics, control, and design. In addition, we integrated external libraries that provide capabilities for modeling offshore systems such as underwater robots and marine energy converters.

16 TIDAL AND WAVE POWER↗

Report on the Atmospheric Temperature Changes and their Drivers (ATC) Activity 2025 Spring Meeting

The Atmospheric Temperature Change and their Drivers (ATC) Activity brings together experts interested in improving understanding of atmospheric temperature variability and trends and their representation in climate data records. ATC pursues this goal by fostering intercomparisons of atmospheric temperature datasets, providing and improving uncertainty information for climate data records, comparing observations with model simulations, assessing atmospheric temperature trends and their drivers, and documenting their efforts in review papers and assessment reports. The ATC activity convened at the Wegener Center for Climate and Global Change at the University of Graz in Graz, Austria over April 23 – 25. The purpose of the meeting was to provide updates on research and datasets related to atmospheric temperature change and variability, to identify areas that need further research, and to coordinate ongoing and future collaborations. Meeting themes included theoretical and simulated controls on atmospheric temperature, the development of new and improved atmospheric temperature datasets, and analysis of atmospheric temperature variability and trends. 18 activity members attended the meeting including 12 in-person attendees and 6 remote attendees. Four new early career activity members attended with support from APARC.

54 ENVIRONMENTAL SCIENCES↗

Simulation of dilatancy-controlled gas migration processes in saturated bentonite using a coupled multiphase flow and elastoplastic H 2 M model

Dilatancy-controlled gas flow in preferential pathways plays a key role in the safety analysis of radioactive waste repositories. This is particularly the case for bentonite, an often-preferred barrier material. Gas flow in preferential pathways is characterized by localization and spontaneous behavior, which is challenging to simulate in numerical models due to strong hydro-mechanical coupling. To analyze a laboratory experiment in the framework of the DECOVALEX-2023 project, this study introduced a new approach of combining continuous modelling methods with spatial material properties derived from material heterogeneities and experimental observations. The proposed model utilized hydro-mechanical spatial distributions, namely Young's modulus and gas entry pressure, and elastoplasticity combined with a linear swelling model. A conceptual strain-dependent permeability approach simulated dilatancy-controlled gas flow based on hydro-mechanical coupling. To test the effectiveness of the presented approach, a gas injection test in a compacted, saturated bentonite sample was simulated using the open-source code OpenGeoSys 5.8 and compared with experimental observations. The presented methodology is capable of simulating localized gas flow in preferential pathways. The spatial distributions of Young's modulus and gas entry pressure affect the swelling pressure, relative permeability and, in combination with the strain-dependent permeability model, also the intrinsic permeability.

42 ENGINEERING↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗