Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization-based search for magnetic monopoles using the NOvA Far Detector

We report a search for highly ionizing magnetic monopoles in the cosmic-ray flux using a 2713-day dataset collected during 2015–2025 with the NOvA Far Detector, a 14-kt segmented detector located on Earth’s surface in Minnesota, United States. The search is sensitive to monopoles across a wide range of speeds, 7 × 10 −4 < 𝛽 < 0.995, and is sensitive to masses as low as 2 × 10 5 GeV for the fastest monopoles. No signal was observed. With the detector’s large surface area and minimal overburden, we achieve the strongest flux limits reported to date in several regions of speed and mass. For heavy monopoles with masses above 10 13 GeV that are able to reach the detector from above or—crossing Earth—from below, we find a flux limit 𝜙 90% < 2 × 10 −16 cm −2 s −1 sr −1 (90% confidence level) for monopoles with 0.005 < 𝛽 < 0.8. Across the same range of speeds, we report a limit 𝜙 90% < 8 × 10 −16 cm −2 s −1 sr −1 for light monopoles with masses above 10 8 GeV that can reach the detector from above.

magnetic monopoles↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

The design and construction of the Chips water Cherenkov neutrino detector

Chips (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the Chips detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗