Search NASASearch

SEARCH · Search NASA

Results for “Design of Thermal Management Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,736 records · Page 6

Lake sediment heatwaves under global warming

Lake sediment heatwaves, driven by rising global temperatures, pose emerging threats to freshwater ecosystems by altering sediment thermal regimes and intensifying sediment biogeochemical processes. Here we present a global-scale assessment of lake sediment heatwaves, examining their historical patterns and projecting future trends under various climate scenarios in 41,499 representative lakes worldwide. Using daily simulated lake sediment temperatures from 1981 to 2010 and future (2071-2100) projections under three Shared Socioeconomic Pathways (SSP126, SSP370, SSP585), we investigate lake sediment heatwave characteristics, including their duration, intensity, frequency, and seasonal timing, worldwide. Our results show that lake sediment heatwaves are generally more persistent and frequent than lake surface heatwaves, with sediment heatwaves in pelagic regions experiencing a significant lag relative to surface conditions. Under future climate scenarios, sediment heatwaves are projected to intensify, with their duration and frequency increasing substantially, particularly under SSP585. These shifts could exacerbate the production of greenhouse gases like methane and increase sediment respiration rates in lakes. This study highlights the need to account for sediment heatwaves in freshwater ecosystem management and climate adaptation strategies to mitigate future impacts.

Limnology

High‐Performance Rechargeable Lithium‐Chlorine Batteries with ALD Conformal Starburst Porous Graphene Positive Electrodes

Abstract Rechargeable alkali metal‐chlorine batteries are emerging as a promising high‐energy‐density solution. However, they confront significant challenges, including the primary issue stemming from the weak binding affinity of cathode materials for Cl 2 , which leads to a sluggish and inadequate supply of Cl 2 during the redox reactions, resulting in a shortened cycle life and low Coulombic efficiency (CE), particularly when operating at ultrahigh specific capacity outputs. Herein, an Al 2 O 3 ‐skinned heterostructured starburst porous graphene with conformal metasurfaces (Al 2 O 3 @rGO) is reported, crafted from a hierarchical porous starburst graphene arranged in a unique layered structure by the PTFE microemulsion skin effect, leveraging subsequent fluidized bed atomic layer deposition (FBALD) of Al 2 O 3 groups. Al 2 O 3 @rGO features superhydrophilicity, effective adsorption, fast kinetics from stable dynamic respiratory interface, high electrical and thermal conductivity anisotropy, intelligent thermal management and safe operation over a wide temperature range. Consequently, the Li‐Cl 2 @Al 2 O 3 @rGO battery achieves an ultrahigh discharge specific capacity of 5000 mAh g −1 at ≈100% CE, and even delivers stable cycling over 200 cycles with 2000 mAh g −1 at an average CE of 99.8% under low temperature environment of ‐40 °C. The scalable heterostructure approach offers a sustainable perspective of the development of functionalized metamaterials and metasurfaces for next‐generation safe and energy‐dense batteries and broader applications.

Chemistry

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

Integral Nuclear Data and Benchmarking Needs for Fusion Energy Systems

Fusion energy systems are currently being designed and optimized using radiation transport codes. To deal with the unique environment inside a fusion-based system, many of these designs incorporate novel materials able to withstand the high radiation fields, ensure adequate cooling and thermal protection, and produce tritium. Validation plays a vital role in building trust in the predictive power of these models and computational methods. Validation of a code consists of modeling documented real-world experiments and comparing the code-predicted response to the measured response. Adequate validation requires measured responses from real-world experiments, also known as integral data, that mimic the system being designed, including materials, impinging radiation, and temperature, among other variables. The most trusted integral data are experimental responses that have been through a rigorous benchmarking process that develops a recommended computational model and evaluates all experimental uncertainties. Finally, there are a few research groups around the world that have been producing integral data for fusion applications, but a substantial investment is needed to address the unique validation needs of the fusion community.

Fusion

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY

A Perspective on the Impact of Group Delay Dispersion in Future Terahertz Wireless Systems

This article discusses the challenges and opportunities of managing group delay dispersion (GDD), and its relation to the performance standards of future sixth-generation (6G) wireless communication systems utilizing terahertz frequency waves. The unique susceptibilities of 6G systems to GDD are described, along with a quantitative description of the sources of GDD, including multipath, rough surface scattering, intelligent reflecting surfaces, and propagation through the atmosphere. An experimental case-study is presented that confirms previous models quantifying the impact of atmospheric GDD. Several GDD manipulation strategies are presented, illustrating their hindered effectiveness in the 6G context. Conversely, some benefits of leveraging GDD to enhance 6G systems, such as improved security and simplified hardware, are also discussed. Finally, a perspective on using photonic GDD control devices is provided, revealing quantitative benefits that may unburden existing equalization schemes. Here, the article argues that GDD will uniquely and significantly impact some 6G systems, but that its careful consideration along with new mitigation strategies, including photonic devices, will help optimize system performance. The conclusion provides a perspective to guide future research in this area.

Strecker, Karl [Oklahoma State University, Stillwa

A Novel Approach to Investigate Thermal Protection Systems Materials

The Koo Research Group (KRG) at The University of Texas at Austin (UT) and KAI has specialized in “Ablation Research” for more than fifteen years. Recently, the group has developed several incredibly unique capabilities that can advance “Thermal Protection Systems (TPS) Materials Research & Development” using an integrated experimental and numerical approach. The paper aims to introduce the methodology KRG has developed to solve this challenging problem. It will discuss how the KRG develops “Process-Properties-Performance” relationships of novel TPS materials in a systematical approach using (a) processing and fabrication, (b) thermal characterization of properties, (c) aerothermal testing, (d) microstructures characterization and analysis, and (e) numerical modeling. Progress and challenges of this research will also be discussed.

Engineering

Mechanical, Electrochemical & Thermal Modeling of Electric Vehicle Batteries for Crash Simulation (CRADA CRD-19-00811 Final Report)

Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Laboratory of the Rockies (NLR) will cooperate with HMC to develop mathematical models for battery cells and modules for simulating abuse response in batteries subject to the type of mechanical crushing that can occur in a full motor vehicle crash.

33 ADVANCED PROPULSION SYSTEMS

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277

Mechanical, Electrochemical & Thermal Models - Training (CRADA CRD-19-00798 Final Report)

Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Renewable Energy Laboratory (NLR) will host Dr. Jaeyoung Lim from HMC for a period of one year to jointly develop mathematical models for battery cells and modules subject to mechanical crush. NLR will assist with the development of mathematical models that Dr. Lim will incorporate into his research effort on new concepts of mobility with electric vehicles.

33 ADVANCED PROPULSION SYSTEMS

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Stabilizer Scars

Quantum many-body scars are eigenstates in nonintegrable isolated quantum systems that defy typical thermalization paradigms, violating the eigenstate thermalization hypothesis and quantum ergodicity. Here, we identify exact analytic scar solutions in a 2+1 dimensional lattice gauge theory in a quasi-1D limit as zero-magic resource stabilizer states. Our results also highlight the importance of magic resources for gauge theory thermalization, revealing a connection between computational complexity and quantum ergodicity.

eigenstate thermalization