Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of the MAMA Detectors for the Hubble Space Telescope Imaging Spectrograph

The development of the Multi-Anode Microchannel Array (MAMA) detector systems started in the early 1970's in order to produce multi-element detector arrays for use in spectrographs for solar studies from the Skylab-B mission. Development of the MAMA detectors for spectrographs on the Hubble Space Telescope (HST) began in the late 1970's, and reached its culmination with the successful installation of the Space Telescope Imaging Spectrograph (STIS) on the second HST servicing mission (STS-82 launched 11 February 1997). Under NASA Contract NAS5-29389 from December 1986 through June 1994 we supported the development of the MAMA detectors for STIS, including complementary sounding rocket and ground-based research programs. This final report describes the results of the MAMA detector development program for STIS.

Timothy, J. Gethyn↗

Development of Laser, Detector, and Receiver Systems for an Atmospheric CO2 Lidar Profiling System

A ground-based Differential Absorption Lidar (DIAL) is being developed with the capability to measure range-resolved and column amounts of atmospheric CO2. This system is also capable of providing high-resolution aerosol profiles and cloud distributions. It is being developed as part of the NASA Earth Science Technology Office s Instrument Incubator Program. This three year program involves the design, development, evaluation, and fielding of a ground-based CO2 profiling system. At the end of a three-year development this instrument is expected to be capable of making measurements in the lower troposphere and boundary layer where the sources and sinks of CO2 are located. It will be a valuable tool in the validation of NASA Orbiting Carbon Observatory (OCO) measurements of column CO2 and suitable for deployment in the North American Carbon Program (NACP) regional intensive field campaigns. The system can also be used as a test-bed for the evaluation of lidar technologies for space-application. This DIAL system leverages 2-micron laser technology developed under a number of NASA programs to develop new solid-state laser technology that provides high pulse energy, tunable, wavelength-stabilized, and double-pulsed lasers that are operable over pre-selected temperature insensitive strong CO2 absorption lines suitable for profiling of lower tropospheric CO2. It also incorporates new high quantum efficiency, high gain, and relatively low noise phototransistors, and a new receiver/signal processor system to achieve high precision DIAL measurements.

Ismail, Syed↗

Development of passive radiation detectors of improved sensitivity

The future development of a solid track high energy particle detector is discussed. The goal is to improve the sensitivity and lower the threshold of the detector. One most widely used material for such purpose is a plastic commercially known as CR-39. A scheme is presented which involves changing the formula of the monomer, diethylene glycol-bis-allyl carbonate. This is to be accomplished by substituting some heteroatoms for H and substituting sulfur atoms for oxygen in the ether linkages. Use of a new plasticizer to make the etched surface clearer than what has been accomplished as of today is suggested. Possible improvement in acquiring better tracks and increasing the ratio of V sub T/V sub B was planned. This is to be accomplished by changing the composition of the etchants, etching time, and etching temperature.

Chakrabarty, M. R.↗

Development of the EXITE detector - A new imaging detector for 20 - 300 keV astronomy

The development and testing of a detector to be used in the Energetic X-ray Imaging Telescope Experiment (EXITE) are reported. It consists of a 34 cm diameter NaI(Tl) crystal coupled directly to a single large image intensifier tube with associated silicon PIN diode readout. The measured spatial and energy resolutions at 122 keV are 6mm (FWHM) and 9 percent (FWHM), respectively. This energy resolution is about 50 percent better than that of any previously flown hard X-ray experiment. These resolutions decrease with the square root of the energy of the incident X-ray, indicating that they are determined by the number of photons emitted in the NaI(Tl) scintillator light flash.

Garcia, M. R.↗

Status of direct detector and array development

Programs are now underway to develop and demonstrate the detector/array technology needed for the Space Infrared Telescope Facility (SIRTF), Large Deployable Reflector (LDR), and other future NASA missions. The development goal is to achieve focal plane sensitivities, at extended integration times over the 2 to 700 microns range, limited only by the low astrophysical backgrounds encountered in cryogenic telescopes such as SIRTF. Dramatic progress has been made in the last 2 to 3 years in integrated array and detector systems for low background astronomical applications. With the broadly based developments and lab characterizations now underway for SIRTF and similar space applications, coupled with the rapidly expanding art and science of ground based astronomical imagery with arrays, the potential for effective utilization of arrays with LDR appears to be very good.

Mccreight, Craig R.↗

Development of a mercuric iodide solid state spectrometer for X-ray astronomy

Mercuric iodide detectors, experimental development for astronomical use, X ray observations of the 1980 Cygnus X-1 High State, astronomical had X ray detectors in current use, detector development, balloon flight of large area (1500 sq cm) Phoswich detectors, had X ray telescope design, shielded mercuric iodide background measurement, Monte Carlo analysis, measurements with a shielded mercuric iodide detector are discussed.

Vallerga, J.↗

Technology Developments for FIR Bolometric Detector Focal Plane Assemblies

A discussion of recent technology developments for far-infrared bolometric detector focal plane assemblies is provided. Some of the developments include strategies for fabricating high filling fraction background limited-transition edge sensor bolometric detectors, impedance-matched absorber coatings, a micromachined blackbody source, and the capability to fabricate indium bumps on non-planar substrates.

Detectors↗

Fluidic hydrogen detector production prototype development

A hydrogen gas sensor that can replace catalytic combustion sensors used to detect leaks in the liquid hydrogen transfer systems at Kennedy Space Center was developed. A fluidic sensor concept, based on the principle that the frequency of a fluidic oscillator is proportional to the square root of the molecular weight of its operating fluid, was utilized. To minimize sensitivity to pressure and temperature fluctuations, and to make the sensor specific for hydrogen, two oscillators are used. One oscillator operates on sample gas containing hydrogen, while the other operates on sample gas with the hydrogen converted to steam. The conversion is accomplished with a small catalytic converter. The frequency difference is taken, and the hydrogen concentration computed with a simple digital processing circuit. The output from the sensor is an analog signal proportional to hydrogen content. The sensor is shown to be accurate and insensitive to severe environmental disturbances. It is also specific for hydrogen, even with large helium concentrations in the sample gas.

Roe, G. W.↗

Further developments of electrographic image detectors

This paper reports the current status of a program to develop far- and middle-ultraviolet-sensitive electrographic detectors. These include large-format, semitransparent-photocathode detectors and opaque-photocathode electrographic Schmidt cameras. Modifications of a previously-demonstrated far-UV large-format detector to make it suitable for possible Shuttle/Spacelab space astronomy investigations have been implemented and tested. Middle-ultraviolet-sensitive large-format and Schmidt electrographic detectors are now in the laboratory development stage. Cesium telluride photocathodes are used to provide sensitivity in the 1700-3100 A spectral range, and techniques for processing these photocathodes are discussed. The preparation and use of polyimide barrier membranes, for protecting the photocathodes from deterioration by film outgassing, are described. A new opaque-photocathode vacuum-ultraviolet-sensitive electrographic detector has been demonstrated, which is based on an oblique-focusing electron optical system similar to that used by Princeton with electron-bombarded CCD arrays. Test results and potential applications of this detector are described.

Carruthers, G. R.↗

Analysis of Measurements for Solid State Lidar Development

A Detector Characterization Facility (DCF), capable of measuring 2-micron detection devices and evaluating heterodyne receivers, was developed at the Marshall Space Flight Center. The DCF is capable of providing all the necessary detection parameters for design, development, and calibration of coherent and incoherent solid state laser radar (lidar) systems. The coherent lidars in particular require an accurate knowledge of detector heterodyne quantum efficient, nonlinearity properties, and voltage-current relationship as a function of applied optical power. At present, no detector manufacturer provides these qualities or adequately characterizes their detectors for heterodyne detection operation. In addition, the detector characterization facility measures the detectors DC and AC quantum efficiencies noise equivalent power and frequency response up to several GHz. The DCF is also capable of evaluating various heterodyne detection schemes such as balanced detectors and fiber optic interferometers. The design and analyses of measurements for the DCF were preformed over the previous year and a detailed description of its design and capabilities was provided in the NASA report NAS8-38609/DO77. It should also be noted that the DCF design was further improved to allow for the characterization of diffractive andholographical optical elements and other critical components of coherent lidar systems.

Amzajerdian, Farzin↗

Detection of long wavelength infrared at moderate temperatures

Technical approaches for the advanced development of 8-12 micrometer detectors operating at elevated temperatures were defined. The theoretical limits to performance of 8-12 micrometer quantum detectors (photoconductive and photovoltaic) and thermal detectors (pyroelectrics, bolometers etc). An analytic model of signal and noise in both quantum detectors and pyroelectric detectors was developed and candidate materials for both detector types were identified and examined. The present status of both quantum and thermal detectors was assessed as well as the parameters limiting operating temperature and detectivity. The areas of research and development likely to lead to detector performance near the theoretical limit are identified.

Tredwell, T. J.↗

Development of EXITE3, Imaging Detectors and a Long Duration Balloon Gondola

In this Report we summarize the work conducted for the EXITE program under grant NAG5-5103. This grant supported the ongoing EXITE program at Harvard for the development of imaging hard x-ray detectors and telescopes over the 3 year period 1997-2000 with a one year extension to 2001 to transition to the next SR&T grant in this program. Work was conducted in three major parts: analysis of the EXITE2 balloon flight data (from our May 1997 flight); development of pixellated imaging Cd-Zn-Te detector arrays and readout systems for the proposed EXITE3 detector and telescope; and development of systems for a Long Duration Balloon (LDB) gondola. Progress on all three major aspects of this research is summarized for each of the years of this grant.

Source record↗