Advanced Photovoltaic Module Characterization: Using Image Transformers for Current–Voltage Curve Prediction From Electroluminescence Images

Individual photovoltaic (PV) module health monitoring can be a daunting task for operation and maintenance of solar farms. Modules can be inspected through luminescence, thermal imaging, and current–voltage (I–V) curve analyzes for identification of damage and power loss. I–V curves provide easily interpretable data to determine module health as they directly provide electrical performance metrics. However, in order to obtain these curves, modules must be disconnected from the array and either removed to a solar simulator or characterized in situ with corrections for module temperature, the incident solar spectrum, and intensity. Luminescence or thermal images of a module are relatively easy to acquire in situ. Electroluminescence (EL) images highlight physical defects in the modules but do not provide easily interpretable features to correlate with electrical performance. This work presents a SWin transformer network to predict I–V curves for PV modules from their corresponding EL images. The predicted I–V curves allow the accurate prediction of the maximum power point (MPP), short-circuit current I sc , and open-circuit voltage V oc with a mean error less of than 1%. Comparing single diode model (SDM) parameters extracted from the predicted curves to those extracted from the true curves, the series resistance R s demonstrates a mean error of 5.19%, and the photocurrent I a mean error of 0.197%. The shunt resistance R sh and dark current Io parameters are predicted with larger errors because of their sensitivity to small changes in the I–V curve.

Byford, Brandon K. [New Mexico State Univ., Las Cr

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE

Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (medium-voltage) level may also become common as a means for improving distribution reliability and resilience.

24 POWER TRANSMISSION AND DISTRIBUTION

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory

Energy-Transit Nexus Tools for Bus Fleet Electrification (NEXTBUS)

NEXTBUS is an open-source software project that integrates NLR's bus energy modeling and simulation tools with multi-objective optimization for fleet operations. NLR is collaborating with a transit technology startup, ReVolt, to commercialize these capabilities by deploying NEXTBUS in ReVolt's software platform. The goal is to manage the added complexities of running a heterogeneous fleet, encompassing battery electric and diesel buses, across a large, multi-depot transit network.

33 ADVANCED PROPULSION SYSTEMS

On-chip frequency-bin quantum photonics

Abstract Frequency-bin encoding furnishes a compelling pathway for quantum information processing systems compatible with established lightwave infrastructures based on fiber-optic transmission and wavelength-division multiplexing. Yet although significant progress has been realized in proof-of-principle tabletop demonstrations, ranging from arbitrary single-qubit gates to controllable multiphoton interference, challenges in scaling frequency-bin processors to larger systems remain. In this Perspective, we highlight recent advances at the intersection of frequency-bin encoding and integrated photonics that are fundamentally transforming the outlook for scalable frequency-based quantum information. Focusing specifically on results on sources, state manipulation, and hyperentanglement, we envision a possible future in which on-chip frequency-bin circuits fulfill critical roles in quantum information processing, particularly in communications and networking.

electro-optic modulators

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION

Visualizing Organizational Influence on Energy Infrastructure

Energy Infrastructure components depend on an evolving, interdependent business ecosystem exposed to long-term, legal, adversarial tactics. An INL-Naval Postgraduate School partnership was designed to support INL Lab Directed Research and Development, NPS graduate research projects, and joint publications. The Technology, Organization, and Person of interest Graph Extraction, Analysis, and Reporting (TOP GEAR) enumerates networks of organizations and people that own, operate, and maintain regional infrastructure assets. TOP GEAR allows analysts to model current and future state what-if scenarios that include technological and policy mitigations.

29 - ENERGY PLANNING, POLICY AND ECONOMY

Role of mechanical stress localizations on the radiation hardness of AlGaN/GaN high electron mobility transistors

Multi-material, multi-layered systems such as AlGaN/GaN high electron mobility transistors (HEMTs) contain residual mechanical stresses that arise from sharp contrasts in device geometry and materials parameters. These stresses, which can be either tensile or compressive, are difficult to detect and eliminate because of their highly localized nature. We propose that their high-stored internal energy makes potential sites for defect nucleation sites under radiation, particularly if their locations coincide with the electrically sensitive regions of a transistor. In this study, we validate this hypothesis with molecular dynamic simulation and experiments exposing both pristine and annealed HEMTS to 2.8 MeV Au +3 irradiation. Our unique annealing process uses mechanical momentum of electrons, also known as the electron wind force (EWF) to mitigate the residual stress at room temperature. High-resolution transmission electron microscopy and cathodoluminescence spectra reveal the reduction of point defects and dislocations near the two-dimensional electron gas region of EWF-treated devices compared to pristine devices. The EWF-treated HEMTs showed relatively higher resilience with approximately 10% less degradation of drain saturation current and ON-resistance and 5% less degradation of peak transconductance. Both mobility and carrier concentration of the EWF-treated devices were less impacted compared to the pristine devices. Our results suggest that the lower density of nanoscale stress localization contributed to the improved radiation tolerance of the EWF-treated devices. Intriguingly, the EWF is found to modulate the defect distribution by moving the defects to electrically less sensitive regions in the form of dislocation networks, which act as sinks for the radiation induced defects and this assisted faster dynamic annealing.

AlGaN/GaN HEMTs

Resilience Assessment for Distribution Systems during Hurricanes: A Learning-Based Framework

This paper presents a proactive strategy for hurricane-resilient distribution systems. It proposes a Bayesian Neural Network-based outage prediction model considering various parameters, including electrical components, and weather and environmental factors. Addressing challenges in imbalanced outage datasets, a Bias-Variance Tradeoff method is proposed. A resilience assessment model quantifies resilience indices, providing insights into system weaknesses. The approach identifies weak points and serves as a planning benchmark. Numerical results on the modified IEEE 123-node test system demonstrate effectiveness in realistic hurricane scenarios.

Vahedi, Soroush

ChargeX OCPI Recommendations

The Open Charge Point Interface (OCPI) is an open protocol that enables electric vehicle (EV) charging systems to work together across networks. It supports communication and data sharing between Charge Point Operators (CPOs), who manage charging stations, and e-Mobility Service Providers (eMSPs), who provide charging services to EV drivers. OCPI facilitates functions like user authorization, remote charge point control, charging session data exchange, and billing through Charge Detail Records (CDRs). This allows EV roaming, so drivers can charge at different networks without multiple accounts. As the EV market grows due to increased adoption and technological advancements, OCPI faces higher demands. This has revealed issues with CDR format consistency, timestamp standardization across regions, transmission of EV-side error codes for troubleshooting, and support for new use cases. These challenges can affect operations and user experience, particularly as the industry starts considering Vehicle-to-Grid (V2G) systems, where EVs supply energy to the grid, and Vehicle-to-Everything (V2X) technologies for broader energy interactions. Using feedback from the ChargeX Diagnostics taskforce discussions, industry 1-on-1 meetings, technical standards, and OCPI’s evolution through versions (e.g., OCPI 2.1.1, 2.2, and 2.2.1), this report identifies these issues and suggests practical recommendations. These aim to improve interoperability, streamline operations, and prepare OCPI for future trends in the EV charging ecosystem.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA

Overview of High-Power Wireless Charging Systems and Analysis of Polyphase Wireless Charging System Phase Winding and Resonant Tuning Network Connection Configurations

In spite of the high energy efficiency and environmental benefits of electric vehicles (EVs), adoption rates are increasing at a relatively slow pace, primarily because of EVs’ limited range and long charging durations. To reduce EV charging times to be comparable to refueling times of conventional vehicles, extreme fast charging systems are required. Such charging systems would reduce drivers’ range anxiety and enable long-distance interstate travel with EVs. Here, this substantial target in charging rates with 15–20 minutes of recharging times, requires research and development from grid to batteries with advanced charging systems. Wireless power transfer systems for EV charging applications are flexible, convenient, and highly efficient, and they allow automated charging. This paper reviews the power electronics and winding and resonant tuning network configurations for polyphase wireless power transfer systems for high-power wireless charging applications.

24 POWER TRANSMISSION AND DISTRIBUTION

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY

Mapping Critical Vulnerabilities in Natural Gas Pipeline Systems through Network Centrality and GIS Analytics

Natural gas plays a central role in the US energy landscape, providing 43% of electricity generation in 2023. Its exclusive recovery ability on pipelines for transmission underscores the importance of understanding the disruption recovery ability of this infrastructure. This study employs a network-based analytical framework integrating geographic information systems (GIS) with multiple centrality measures—betweenness, closeness, degree, and eigenvector—to pinpoint key segments and evaluate the structural robustness of the national pipeline network. Pipelines are grouped by System ID and Operator ID to capture variations across organizational and physical structures. The analysis reveals uneven patterns of network influence, where certain pipelines function as critical connectors or dominant hubs. Spatial mapping highlights geographic dependencies and potential chokepoints, offering a clear view of where targeted risk prevention measures would be most effective. The findings provide practical guidance for prioritizing maintenance, enhancing system robustness, and mitigating risks to ensure a stable and secure energy supply. Future research will expand the framework to incorporate dynamic operational data and real-time network behavior.

Peterson, Steven [ORNL] (ORCID:0000000287672998)

VRN3P: Variational Recurrent Neural Network Based Net-Load Prediction under High Solar Penetration

This is the final technical report for the SETO-funded VRN3P project (PNNL# 76914). The goal of this project, led by Pacific Northwest National Laboratory (PNNL), in collaboration with Lawrence Livermore National Laboratory (LLNL) and Portland General Electric (PGE), was to develop and validate a deep variational recurrent neural network-based net-load prediction (VRN3P) framework for probabilistic time-series forecasting of day-ahead net-load under high solar penetration scenarios. The project team reports successful design of a novel probabilistic net-load forecasting architecture, comprising of a variational autoencoder and a recurrent neural network, which demonstrates 30% improvement in forecast performance, 60% improvement in training time, and consumes 44% less memory, when compared with conventional baseline models. The team tested the VRN3P model performance on GridLAB-D test-cases representing varying BTM solar penetration levels of 20%, 30%, and 50%, with integrated time-series net-load profiles provided by the utility partner (PGE). The VRN3P model demonstrate <2% hourly MAPE (averaged over the year) for day- ahead net-load forecast on the test scenario with 20% BTM solar. Transfer learning extension of the VRN3P model has demonstrated 8.33× speed-up in training, while still achieving acceptable forecast performance of 2.24% hourly MAPE on the 30% BTM solar penetration test-scenario. A preliminary version of the VRN3P GridAPPS-D™has been developed, along with a web-based interactive user-interface (named ‘Forte’) which has made available on GitHub for public use.

24 POWER TRANSMISSION AND DISTRIBUTION

Simulation Evaluation of a Large-Scale Implementation of Virtual-Phase Link-Based Model Predictive Control

Traffic congestion is a serious problem in the US, and traffic signal control is one of the effective solutions to congestion. Previous research on model predictive control (MPC)-based traffic signal control showed substantial benefits over conventional methods. This study focused on implementing MPC over a large-scale network with complex intersections and the impact of cycle length, network size, and imperfect state estimation on performances. This study implemented a virtual phase link (VPL)-based model predictive control method which used the number of vehicles in each VPL as input state variables and was suitable for National Electrical Manufacturing Association (NEMA) ring-barrier control. To test the impact of network size, the performance of distributed MPC (36 intersections in the network are divided into five subnetworks) was compared with that of MPC over the full network for a set of cycle lengths. To test the impact of imperfect state estimation, we synthetically infused estimation error and developed two scenarios, MPC-error and MPC-error narrow, which had higher and lower estimation errors, respectively. The performance of these MPC methods was compared with that of the existing time-of-day (TOD) method and an offline method that used Webster's method for split and MULTIBAND for cycle length and offset optimization. Trajectory and linkwise signal performance measures were collected from the simulation to evaluate performance. The distributed MPC method with perfect state estimation had the lowest delay and highest energy efficiency of all the methods. The performance of MPC decreased as the prediction inaccuracy increased. MPC-error had 7% and 11% more delay than MPC-error narrow in the morning and evening peaks, respectively. Overall, simulation results suggest that even with imperfect state estimation, MPC methods will outperform offline methods significantly.

large-scale simulation

Powered By CADET

The Capacity Expansion Decision Support for Distribution Networks (CADET) is a Python-based library and framework for creating electrical distribution system capacity planning tools for cost-effective, reliable power delivery. It enables the creation of modular, scalable, and extensible distribution capacity planning tools by providing a high-level optimization interface, parameter and options data managers, optimization constraint and objective libraries, generalized nomenclature, a system for tracking and modifying distribution network changes, optimization solution validation, and other capabilities. This webinar will describe 1) the motivation for creating CADET, 2) key designs, and 3) several use cases.

24 POWER TRANSMISSION AND DISTRIBUTION

Machine learning based reconstruction of intracardiac electrical behavior based on electrocardiograms

A computer-based system and process are disclosed for reconstructing the internal electrical behavior of a patient's heart based partly or wholly on the patient's electrocardiogram (ECG). The output of the process may include, for example, a cardiac activation map, and/or a representation of transmembrane potentials over time. The process advantageously does not require any medical imaging of the patient, and does not require any special medical equipment. For example, the patient's activation map and transmembrane potentials may be reconstructed based solely on a preexisting or newly-obtained 12-lead cardiac ECG of the patient. The process makes use of a machine learning model, such as a neural network based model, trained with actual and/or simulated ECGs and intracardiac electrical data (typically transmembrane potentials) of many thousands of patients. Because an insufficient quantity of such data exists for actual patients, model training may be performed using ECGs and intracardiac electrical data obtained through computer simulations.

Blake, Robert