Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRICAL CIRCUITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ground-based instrumentation for measurements of atmospheric conduction current and electric field at the South Pole

Attention is given to instruments constructed to measure the atmospheric conduction current and the atmospheric electric field - two fundamental parameters of the global-electric circuit. The instruments were deployed at the Amundsen-Scott South Pole Station in January 1991 and are designed to operate continuously for up to one year without operator intervention. The atmospheric current flows into one hemisphere, through the electronics where it is measured, and out the other hemisphere. The electric field is measured by a field mill of the rotating dipole type. Sample data from the first days of operation at the South Pole indicate variations in the global circuit over time scales from minutes to hours to days.

Byrne, G. J.↗

Damping of structural vibrations with piezoelectric materials and passive electrical networks

The possibility of dissipating mechanical energy with piezoelectric material shunted with passive electrical circuits is investigated. The effective mechanical impedance for the piezoelectric element shunted by an arbitrary circuit is derived. The shunted piezoelectric is shown to possess frequency dependent stiffness and loss factor which are also dependent on the shunting circuit. The generally shunted model is specialized for two shunting circuits: the case of a resistor alone and that of a resistor and inductor. For resistive shunting, the material properties exhibit frequency dependence similar to viscoelastic materials, but are much stiffer and more independent of temperature. Shunting with a resistor and inductor introduces an electrical resonance, which can be optimally tuned to structural resonances in a manner analogous to a mechanical vibration arsorber. Techniques for analyzing systems which incorporate these shunting cases are presented and applied to a cantilevered beam experiment. The experimental results for both the resistive and resonant shunting circuits validate the shunted piezoelectric damping models.

Hagood, N. W.↗

Simplified Theory of the Magneto

This paper contains part of the results of ignition investigations being made for the National Advisory Committee for Aeronautics at the Bureau of Standards, and describes a type of circuit which has been found useful for representing the action of high-tension magneto. While this equivalent circuit is relatively simple, and consequently can be used as a basis for deriving definite mathematical formulas for induced voltages and similar quantities, it has been found experimentally to correspond quite closely in its performance with the highly complicated electrical circuits of an actual magneto. In the paper formulas are given for the voltage induced in the secondary under various conditions of operation, and a number of numerical examples are worked out showing the application of the equations to a variety of practical problems.

Silsbee, F B↗

Electromagnetic compatibility and the all-electric airplane

NASA is studying the feasibility of installing 'all-electric' controls in future commercial aircraft, replacing the current hydraulic and pneumatic systems. Planes utilizing such equipment should weigh less and be cheaper to maintain, but might also be susceptible to interference from undesired external electromagnetic fields. Possible sources of these extraneous signals include radio and television broadcasters, two-way communications stations, and radar installations of all kinds. One way to reduce the hazard would be to use fiber-optic cables to carry signals from the cockpit to the various points of use, a concept known as 'fly-by-light' or FBL. However, electrical circuits (PBW, or 'power-by-wire') would still be required at both ends of the cables to perform control functions, so the possibility of harmful interference would remain. Computer models for two different antennas were created in order to find the magnitude of the electric fields which would be generated in the airspace around them while in the transmit mode. The first antenna was a horizontal 'rhombic' used by the Voice of America (VOA) for long-distance short-wave broadcasting. The second antenna was a multi-element 'log-periodic dipole array' (LPDA) of a type often used for two-way radio communications. For each case, a specified amount of power was applied in the computer model, and the resulting electric field intensity was predicted at a variety of locations surrounding the antenna. This information will then be used to calculate the levels of interference which could occur inside an airplane flying in the vicinity of these radiation emitters.

Christman, Al↗

A general method for the analysis of compact multifluid heat exchangers.

An analytical method of treating the complex heat-transfer processes involved in compact multifluid heat exchangers is described. The method is based on representing the heat transfer by means of the analogy between heat-transfer paths and electrical circuits. For plate-fin configurations, it includes the effects of heat exchange among nonadjacent fluids due to conduction through the fins of intervening passages. The application of the developed solution procedures to the design and analysis of multifluid heat exchangers is also discussed. Results obtained in using the electrical-analog method to examine the effects of conduction on performance are presented graphically in parametric form for a number of three-fluid plate-fin configurations. The discussion of the data presented includes a comparison with results given by alternative analytical procedures which neglect direct transfer between nonadjacent fluids.

Demetri, E. P.↗

Advanced Stirling Convertor Control Unit Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

Future NASA missions could include long-duration flyby, orbital, lander, or rover applications where generating power from sunlight may be limited. Radioisotope power systems (RPSs) provide a dependable power source for missions where inadequate sunlight or operational requirements make other power systems impractical. Over the past 16 years, NASA Glenn Research Center has been supporting the development of RPSs. The advanced Stirling radioisotope generator (ASRG) utilized a pair of advanced Stirling convertors (ASCs). Although flight development of the ASRG has been canceled, much of the technology and hardware continued development and testing to guide future activities. Specifically, a controller for the convertor(s) is an integral part of a Stirling-based RPS. For the ASRG design, the controller maintains stable operation of the convertors, regulates the alternating current produced by the linear alternator of the convertor, provides a specified direct-current output voltage for the spacecraft, and synchronizes the piston motion of the two convertors to minimize vibration as well as manage and maintain operation with a stable piston amplitude and hot-end temperature. It not only provides power to the spacecraft but also must regulate convertor operation to avoid damage to internal components and maintain safe thermal conditions after fueling. Lockheed Martin Coherent Technologies, Inc., has designed, developed, and tested an ASC control unit engineering development unit (ACU EDU) to support this effort. GRC used the ACU EDU as part of its nonnuclear representation of a RPS that also consists of a Dual advanced Stirling convertor simulator (DASCS), and associated support equipment to perform a test in the Radioisotope Power Systems System Integration Laboratory (RSIL). The RSIL was designed and built with flexibility to evaluate hardware utilizing RPS technology. The RSIL provides insight into the electrical interactions between as many as three radioisotope power generators, associated control strategies, and typical electric system loads. The first phase of testing included a DASCS that was developed by Johns Hopkins University Applied Physics Laboratory and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. Testing included the following spacecraft electrical energy storage configurations: capacitor, battery, and supercapacitor. Testing of the DASCS and ACU in each energy storage configuration included simulation of a typical mission profile and transient voltage and current data during load turnon and turnoff. Testing for these devices also included the initiation of several system faults such as short circuits, electrical bus overvoltage, undervoltage, and a "dead bus" recovery to restore normal power operations. The goal of this testing was to verify operation of the ACU(s) when connected to a spacecraft electrical bus. The results of these tests are presented here.

General↗

Advanced Stirling Convertor Control Unit Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

Future NASA missions could include establishing Lunar or Martian base camps, exploring Jupiters moons and travelling beyond where generating power from sunlight may be limited. Radioisotope Power Systems (RPS) provide a dependable power source for missions where inadequate sunlight or operational requirements make other power systems impractical. Over the past decade, NASA Glenn Research Center (GRC) has been supporting the development of RPSs. The Advanced Stirling Radioisotope Generator (ASRG) utilized a pair of Advanced Stirling Convertors (ASC). While flight development of the ASRG has been cancelled, much of the technology and hardware continued development and testing to guide future activities. Specifically, a controller for the convertor(s) is an integral part of a Stirling-based RPS. For the ASRG design, the controller maintains stable operation of the convertors, regulates the alternating current produced by the linear alternator of the convertor, provides a specified direct current output voltage for the spacecraft, synchronizes the piston motion of the two convertors in order to minimize vibration as well as manage and maintain operation with a stable piston amplitude and hot end temperature. It not only provides power to the spacecraft but also must regulate convertor operation to avoid damage to internal components and maintain safe thermal conditions after fueling. Lockheed Martin Coherent Technologies has designed, developed and tested an Engineering Development Unit (EDU) Advanced Stirling Convertor Control Unit (ACU) to support this effort. GRC used the ACU EDU as part of its non-nuclear representation of a RPS which also consists of a pair of Dual Advanced Stirling Convertor Simulator (DASCS), and associated support equipment to perform a test in the Radioisotope Power Systems System Integration Laboratory (RSIL). The RSIL was designed and built to evaluate hardware utilizing RPS technology. The RSIL provides insight into the electrical interactions between as many as 3 radioisotope power generators, associated control strategies, and typical electric system loads. The first phase of testing included a DASCS which was developed by Johns Hopkins UniversityApplied Physics Laboratory and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. Testing included the following spacecraft electrical energy storage configurations: capacitive, battery, and supercapacitor. Testing of the DASCS and ACU in each energy storage configuration included simulation of a typical mission profile, and transient voltage and current data during load turn-on/turn-off. Testing for these devices also included the initiation of several system faults such as short circuits, electrical bus over-voltage, under-voltage and a dead bus recovery to restore normal power operations. The goal of this testing was to verify operation of the ACU(s) when connected to a spacecraft electrical bus.

Dugala, Gina M.↗

Variations in the electrical short-circuit current decay for recombination lifetime and velocity measurements

An improved measurement system for electrical short-circuit current decay is presented that extends applicability of the method to silicon solar cells having an effective lifetime as low as 1 microsec. The system uses metal/oxide/semiconductor transistors as voltage-controlled switches. Advances in theory developed here increase precision and sensitivity in the determination of the minority-carrier recombination lifetime and recombination velocity. A variation of the method, which exploits measurements made on related back-surface field and back-ohmic contact devices, further improves precision and sensitivity. The improvements are illustrated by application to 15 different silicon solar cells.

Jung, Tae-Won↗

Radiation sensitive solid state switch

A mechanically operable solid state switch suited for use in achieving a variable circuit-switching function is described. This switch is characterized by an annular array of photoresponsive switching devices, disposed in communication with an included source of radiation, and a plurality of interchangeable, mechanically operable interrupter disks. Each disk has a predetermined pattern of transparent and opaque portions. Operative displacement of each disk serves to make and break selected electrical circuits through the photo responsive devices of said array.

Hutto, R. J.↗

A probabilistic analysis of electrical equipment vulnerability to carbon fibers

The statistical problems of airborne carbon fibers falling onto electrical circuits were idealized and analyzed. The probability of making contact between randomly oriented finite length fibers and sets of parallel conductors with various spacings and lengths was developed theoretically. The probability of multiple fibers joining to bridge a single gap between conductors, or forming continuous networks is included. From these theoretical considerations, practical statistical analyses to assess the likelihood of causing electrical malfunctions was produced. The statistics obtained were confirmed by comparison with results of controlled experiments.

Elber, W.↗

Using In-Situ Deposition of Metallic Thin Films on Mars to Monitor Atmospheric H20

We describe the use of a novel sensor, designed to characterize the reactive nature of the Martian atmosphere, to also characterize the instantaneous abundance of atmospheric H,O. The sensor deposits, in situ, a thin silver film onto a sapphire substrate and monitors oxidation by measuring resistance of the Ag film during both deposition and subsequent oxidation [1,2]. . The evaporation source is placed in the center of a hollow, open-ended tube. On flash heating the source, evaporated metallic silver rapidly reacts with oxidizing gases in the tube, depositing on the tube walls as a resisitive Ag oxide film. Unoxidized silver deposits over the Ag oxides, once the oxidizing gases in the vicinity of the source have been consumed. Since the ends of the tube are open, atmospheric gases in the tube cause a time delay as the evaporated silver initially reacts with the available O2, and H2O; once oxidizing gases in the tube are significantly depleted, a silver film closes the chemiresistor circuit. In principle this operation mode provides a repeatable measure of the variable H2O abundance, since O2, levels are constant in the atmosphere. To explore the utility of the instrument as an H2O sensor, predict its behavior, and identify possible failure modes, we developed a numerical model of the instrument, and exercised it for Mars conditions. The model predicts the behavior of the electrical circuit, the temperature dependence of resistivity for each component, and the resultant Joule heating. The model balances Joule heating against radiation, sensible heat loss to ambient CO2, and, latent heat loss from sublimating Ag. The flux of Ag atoms from the source is tracked continuously. In the gas phase, the number density of Ag, O2, and H2O is calculated, along with their reaction rates on collision. The model suggests that Ag substantially depletes H2O only near the center of the tube. The model supports the hypothesis that the onset of high conductivity between the A u electrodes is a function of the H2O abundance in the ambient gas, but only to a limit; when H2O abundances are buffered at or above 240K (an H2O abundance that would not have occurred on Mars), metallic Ag never deposits in excess of Ago, and the circuit does not close. A significant difference in the Mars simulation is that the Ag source sublimates more quickly, primarily because of differences in sensible heat fluxes from the source. This allows subsequent heating of the W filament used to support the Ag source. Had the originally-designed experimental sequence been carried out on Mars, the filament might have melted, making subsequent investigations impossible.

Zent, A. P.↗

Solar modulation of atmospheric electrification through variation of the conductivity over thunderstorms

Variations of the current in the global atmospheric electrical circuit can be produced through regulation of the resistance between the tops of thunderclouds and the ionosphere. Long-and short-term changes in the conductivity of this region occur due to changes in the ionization rate resulting from solar activity. Previous suggestions that the phenomena might be due to conductivity variations in the fair weather part of the world or an influx of space charge to the upper atmosphere are considered unlikely. It might be possible to test the proposed mechanism by measuring the temporal variation of the ionospheric potential during disturbed solar periods. Another approach would be to measure simultaneously the variation in ionization rate and electric current over thunder-storms. Several ways in which changes in atmospheric electrification might influence other meteorological phenomena are mentioned.

Markson, R.↗

Solar modulation of atmospheric electrification through variation of the conductivity over thunderstorms

It is suggested that variations of the current in the global atmospheric electrical circuit can be produced through regulation of the resistance between the tops of thunderclouds and the ionosphere. Long- and short-term changes in the conductivity of this region occur due to changes in the ionization rate resulting from solar activity. Previous suggestions that the phenomena might be due to conductivity variations in the fair weather part of the world or an influx of space charge to the upper atmosphere are discussed and considered unlikely. It might be possible to test the proposed mechanism by measuring the temporal variation of the ionospheric potential during distributed solar periods. Another approach would be to measure simultaneously the variation in ionization rate and electric current over thunderstorms. Several ways in which changes in atmospheric electrification might influence other meteorological phenomena are mentioned.

Markson, R.↗

Dst Index in the 2008 GEM Modeling Challenge - Model Performance for Moderate and Strong Magnetic Storms

The GEM 2008 modeling challenge efforts are expanding beyond comparing in-situ measurements in the magnetosphere and ionosphere to include the computation of indices to be compared. The Dst index measures the largest deviations of the horizontal magnetic field at 4 equatorial magnetometers from the quiet-time background field and is commonly used to track the strength of the magnetic disturbance of the magnetosphere during storms. Models can calculate a proxy Dst index in various ways, including using the Dessler-Parker Sckopke relation and the energy of the ring current and Biot-Savart integration of electric currents in the magnetosphere. The GEM modeling challenge investigates 4 space weather events and we compare models available at CCMC against each other and the observed values of Ost. Models used include SWMF/BATSRUS, OpenGGCM, LFM, GUMICS (3D magnetosphere MHD models), Fok-RC, CRCM, RAM-SCB (kinetic drift models of the ring current), WINDMI (magnetosphere-ionosphere electric circuit model), and predictions based on an impulse response function (IRF) model and analytic coupling functions with inputs of solar wind data. In addition to the analysis of model-observation comparisons we look at the way Dst is computed in global magnetosphere models. The default value of Dst computed by the SWMF model is for Bz the Earth's center. In addition to this, we present results obtained at different locations on the Earth's surface. We choose equatorial locations at local noon, dusk (18:00 hours), midnight and dawn (6:00 hours). The different virtual observatory locations reveal the variation around the earth-centered Dst value resulting from the distribution of electric currents in the magnetosphere during different phases of a storm.

Rastaetter, Lutz↗

Particle Acceleration in Dissipative Pulsar Magnetospheres

Pulsar magnetospheres represent unipolar inductor-type electrical circuits at which an EM potential across the polar cap (due to the rotation of their magnetic field) drives currents that run in and out of the polar cap and close at infinity. An estimate ofthe magnitude of this current can be obtained by dividing the potential induced across the polar cap V approx = B(sub O) R(sub O)(Omega R(sub O)/c)(exp 2) by the impedance of free space Z approx eq 4 pi/c; the resulting polar cap current density is close to $n {GJ} c$ where $n_{GJ}$ is the Goldreich-Julian (GJ) charge density. This argument suggests that even at current densities close to the GJ one, pulsar magnetospheres have a significant component of electric field $E_{parallel}$, parallel to the magnetic field, a condition necessary for particle acceleration and the production of radiation. We present the magnetic and electric field structures as well as the currents, charge densities, spin down rates and potential drops along the magnetic field lines of pulsar magnetospheres which do not obey the ideal MHD condition $E cdot B = 0$. By relating the current density along the poloidal field lines to the parallel electric field via a kind of Ohm's law $J = sigma E_{parallel}$ we study the structure of these magnetospheres as a function of the conductivity $sigma$. We find that for $sigma gg OmegaS the solution tends to the (ideal) Force-Free one and to the Vacuum one for $sigma 11 OmegaS. Finally, we present dissipative magnetospheric solutions with spatially variable $sigma$ that supports various microphysical properties and are compatible with the observations.

Kazanas, Z.↗

Verification of thermal analysis codes for modeling solid rocket nozzles

One of the objectives of the Solid Propulsion Integrity Program (SPIP) at Marshall Space Flight Center (MSFC) is development of thermal analysis codes capable of accurately predicting the temperature field, pore pressure field and the surface recession experienced by decomposing polymers which are used as thermal barriers in solid rocket nozzles. The objective of this study is to provide means for verifications of thermal analysis codes developed for modeling of flow and heat transfer in solid rocket nozzles. In order to meet the stated objective, a test facility was designed and constructed for measurement of the transient temperature field in a sample composite subjected to a constant heat flux boundary condition. The heating was provided via a steel thin-foil with a thickness of 0.025 mm. The designed electrical circuit can provide a heating rate of 1800 W. The heater was sandwiched between two identical samples, and thus ensure equal power distribution between them. The samples were fitted with Type K thermocouples, and the exact location of the thermocouples were determined via X-rays. The experiments were modeled via a one-dimensional code (UT1D) as a conduction and phase change heat transfer process. Since the pyrolysis gas flow was in the direction normal to the heat flow, the numerical model could not account for the convection cooling effect of the pyrolysis gas flow. Therefore, the predicted values in the decomposition zone are considered to be an upper estimate of the temperature. From the analysis of the experimental and the numerical results the following are concluded: (1) The virgin and char specific heat data for FM 5055 as reported by SoRI can not be used to obtain any reasonable agreement between the measured temperatures and the predictions. However, use of virgin and char specific heat data given in Acurex report produced good agreement for most of the measured temperatures. (2) Constant heat flux heating process can produce a much higher heating rate than the radiative heating process. The results show that heating rates of 125 C/s (225 F/s) can be achieved. (3) The electrical resistance of the FM 5055 samples were about 150 Omega in the virgin state, and decreased to about 35 Omega when charred. A reliable scheme must be developed to electrically insulate the composite from the heater foil in order to prevent any current leakage into the sample which can result in volumetric heating of the char zone of the composite.

Keyhani, M.↗

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00↗

SansEC: A New Dimension to Sensing Electrical Sensors with No Electrical Connections

This DVD contains an introduction to SansEC, a new electrical sensor technology without electrical connections. This new class of sensors represents a stand-alone 2-dimensional geometric pattern of electrically open circuits without electrical connections. The sensor is powered with an external, harmonic magnetic field and as the property being sensed changes, responds to frequency, amplitude or bandwidth changes. This response is interrogated using an external antenna, a single electrical component having no electrical connections. The sensor can be encased in any nonconductive material to provide protection from its environment. If the container is nonconductive, the sensor can be placed external to the container without contacting it, making installation very simple. An encased sensor can also be placed inside a container for measuring the level of any fluid or material, including acids. Any readout device can be used with the sensor, including standard or digital gauges. SansEC sensors can be used to measure real-time fluid slosh to determine if a fuel tank's internal structural isogrid can be used to replace some of the baffles surface, thus reducing the overall baffle weight and giving a better understanding of the effect that isogrids have on fluid motion. Any SansEC sensor can also be used for damage or tamper detection. When damaged, torn or tampered with, the measured response shift in frequency is commensurate to the detected damage, with the response frequency increasing with rising damage. The unique sensor design allows it to function even if damaged, because unlike other circuits, there is no single point on the sensor that, if damaged, renders it non-functional. The broad metallic coverage of the array allows the array to be one of many thermal insulation layers. Two such arrays were tested to understand the effects of high velocity damage. Each test article was targeted with metal projectiles emulating micrometeorite or orbital debris impact. Even with the damage that the sensors received every sensor was still functional with the new response baseline, and remained capable of detecting even more damage.

Source record↗