Search NASA⌕ Search

SEARCH · Search NASA

Results for “EPA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of Oil and Gas Ethane and Methane Emissions in the Southcentral and Eastern United States Using Four Seasons of Continuous Aircraft Ethane Measurements

In the last decade, much work has been done to better understand methane (CH 4 ) emissions from the oil and gas (O&G) industry in the United States. Ethane (C 2 H 6 ), a gas that is co-emitted with thermogenic sources of CH 4 , is emitted in the US predominantly by the O&G sector. Here, in this study, we perform an inverse analysis on 200 h of atmospheric boundary layer C 2 H 6 measurements to estimate C 2 H 6 emissions from the US O&G sector. Measurements were collected from 2017 to 2019 as part of the Atmospheric Carbon and Transport (ACT) America aircraft campaign and encompass much of the central and eastern United States. We find that for the fall, winter, and spring campaigns, C 2 H 6 data consistently exceeds values that would be expected based on EPA O&G leak rate estimates by more than 50%. C 2 H 6 observations from the summer 2019 data set show significantly lower C 2 H 6 enhancements in the southcentral region that cannot be reconciled with data from the other three seasons, either due to complex meteorological conditions or a temporal shift in the emissions. Combining the fall, winter, and spring C 2 H 6 posterior emissions estimate to an inventory of O&G CH 4 emissions, we estimate that O&G CH 4 emissions are larger than EPA inventory values by 48%–76%. Uncertainties in the gas composition data limit the accuracy of using C 2 H 6 as a proxy for O&G CH 4 emissions. These limits could be resolved retroactively by increasing the availability of industry-collected gas composition data.

54 ENVIRONMENTAL SCIENCES↗

Examining Daily Temporal Characteristics of Oil and Gas Methane Emissions in the Delaware Basin Using Continuous Tower Observations

Top-down studies have found consistent underestimations in the United States Environmental Protection Agency (EPA) methane emissions inventory from the oil and gas (O&G) sector. Many of these studies use observations that bias toward hours when worktime activity occurs. In this study, we analyze over 2 years of methane measurements from a tower network in the Delaware basin to analyze hourly temporal emission patterns. Inversion results suggest a range in emissions from 137 Mg/hr at night to 197 Mg/hr during the day, present during both weekdays and weekends. If these results are applicable to other basins, daytime-influenced methodologies may overestimate daily emission rates by up to 27%. This bias does not reconcile the more than 200% difference between the EPA inventory and top-down estimates in the Delaware basin. This study demonstrates how continuous measurement networks can be combined with detailed activity data to improve bottom-up inventories.

54 ENVIRONMENTAL SCIENCES↗

The effectiveness of TRIS and ammonium buffers in glass dissolution studies: a comparative analysis

Abstract Selecting appropriate buffers is crucial for evaluating the chemical durability of glass under controlled conditions such as in the EPA 1313 test designed to measure elemental release as a function of pH. The efficacy of two alkali-metal free buffers, TRIS (NH 2 C(CH 2 OH) 3 ) and ammonium chloride—ammonia (NH 3 /NH 4 Cl), was investigated during EPA 1313 testing of a simulated Hanford low-activity waste borosilicate glass in the alkaline regime (pH 8.5–10.5) at varying temperatures (RT, 40 °C, and 60 °C). While both buffers maintained the desired pH at room temperature, and up to 40 °C, the effectiveness of TRIS decreased at elevated temperatures, particularly at pH 10.5. Although 11 B NMR showed evidence of TRIS-B complexation, its effect on the rate of elemental release was found to be negligible under the test conditions. With ammonium buffer, the release of alkali cations was slightly elevated when compared to the same conditions with TRIS at early time points.

36 MATERIALS SCIENCE↗

Estimating biotic integrity to capture existence value of freshwater ecosystems

The US Environmental Protection Agency (EPA) uses a water quality index (WQI) to estimate benefits of proposed Clean Water Act regulations. The WQI is relevant to human use value, such as recreation, but may not fully capture aspects of nonuse value, such as existence value. Here, we identify an index of biological integrity to supplement the WQI in a forthcoming national stated preference survey that seeks to capture existence value of streams and lakes more accurately within the conterminous United States (CONUS). We used literature and focus group research to evaluate aquatic indices regularly reported by the EPA’s National Aquatic Resource Surveys. We chose an index that quantifies loss in biodiversity as the observed-to-expected (O/E) ratio of taxonomic composition because focus group participants easily understood its meaning and the environmental changes that would result in incremental improvements. However, available datasets of this index do not provide the spatial coverage to account for how conditions near survey respondents affect their willingness to pay for its improvement. Therefore, we modeled and interpolated the values of this index from sampled sites to 1.1 million stream segments and 297,071 lakes across the CONUS to provide the required coverage. The models explained 13 to 36% of the variation in O/E scores and demonstrate how modeling can provide data at the required density for benefits estimation. We close by discussing future work to improve performance of the models and to link biological condition with water quality and habitat models that will allow us to forecast changes resulting from regulatory options.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing manufacturing wastewater in the United States for the purpose of analyzing energy requirements for reuse

This paper seeks to inform an improved understanding of the energy tradeoff associated with on-site manufacturing water reuse in the United States from a lifecycle perspective, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. We survey the literature to assess the current state of reuse and its motives and barriers in the United States, before synthesizing information from publicly available EPA data on contaminants in US manufacturing wastewaters and technologies for treating them. Using the available data, we derive a set of “ubiquitous contaminants” among the top ten in terms of mass discharged in more than half of US manufacturing subsectors (NAICS 31–33) according to EPA permit data. We also present information on proven treatment trains and their energy requirements. We then compare water quality requirements for specific contaminants in reclaimed water to those characteristic of wastewater streams currently being discharged from manufacturing plants into surface waters to highlight sectors with reuse opportunities that could require little cost to realize, such as primary metals and, to a lesser extent, petroleum and coal products. We conclude by highlighting data limitations that need to be rectified before applying the framework more broadly and discussing how these data gaps could be filled. Better understanding the relationship between energy and water in the context of on-site manufacturing water reuse would allow manufacturers to improve resiliency by reducing regulatory, physical, and reputational risks while lessening their footprint on local watersheds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview and How-to Tutorial Videos for Using NEWTS Data

Overview and How-to Tutorial Videos for Using NEWTS Data Video 1: Overview of NEWTS Database Video 2: How-to tutorial for EPA Flue Gas Desulfurization (FGD) Effluent NEWTS dataset Video 3: How-to tutorial for USGS Produced Waters NEWTS dataset Video 4: How-to tutorial for EPA Ash NEWTS dataset Video 5: How-to tutorial for Quillinan, et al 2018 DOE Geothermal Technology Office REE dataset Video 6: Tutorial video on navigating the NEWTS Dashboard, with an overview of NEWTS and navigating between the NEWTS Dashboard and Datasets (https://netl-doe.maps.arcgis.com/apps/dashboards/a5fa4192f7c6478dab3d6180d9c30b84) Video 7: Additional tutorial video on navigating the NEWTS Dashboard and investigating specific data points in the Dashboard and Datasets Video 8: Re-record of recent webinar giving an overview of the NEWTS Database and Dashboard, including interacting with the NEWTS Dashboard, locating specific data points, and finding the relevant streams in the NEWTS Database and datasets on EDX. Includes overview of the datasets, case studies, and steps for taking stream data from the database and modeling stream data in OLI Studio and Geochemist's Workbench. Note: Video 3 tutorial is also applicable to the USGS Brackish Water NEWTS dataset.

Aqueous Chemistry↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a Prototype Methodology to Rank CO2-EOR Wells and Assess Their Reuse Potential for Geologic Carbon Storage

This paper presents a prototype methodology to assess the possible transition of Class II carbon dioxide-enhanced oil recovery (CO2-EOR) wells to Class VI wells. The focus is on wellbore construction materials—casing, cement, tubing, and the packer—and includes comprehensive workflows to evaluate these materials, with primary emphasis on compliance with Environmental Protection Agency (EPA) Class VI well construction and conversion guidelines. These workflows systematically assess material properties and performance criteria to ensure regulatory compliance and optimize long-term wellbore integrity and functionality. Utilizing Python scripts and JavaScript Object Notation (JSON) representations, the study automates checks on digitized Texas Railroad Commission (TRRC) data to rank wells based on workflow criteria. By emphasizing critical factors such as casing integrity, cementing techniques, tubing compatibility, and packer selection, the methodology helps well owners and operators prioritize wells for potential reuse as CO2 injection wells. Given limitations in digitized data, manual user verification is required in some sections. Future improvements include integrating non-digitized data through web scraping and machine learning techniques. This research serves as a practical guide for stakeholders, supporting environmental compliance and sustainable well operations.

geologic carbon sequestration↗

Improving cellulose attribution by selectively removing yeast glucans from grain fermentation intermediates

Abstract This article presents an industry-relevant method for quantifying cellulose in mixed substrate samples. We built upon the cellulosic glucan measurement proposed by Sluiter et al. (2021) to investigate significant cellulose loss under cold caustic conditions, which has hindered the establishment of an industrially relevant method. To overcome this issue, we used dimethyl sulfoxide (DMSO) as an alternative solvent, which avoids mercerization reactions (Budtova and Navard 2015) but may leave some resistant starch in the sample. Treatment via an enzyme mixture removed starch and conformed to US Environmental Protection Agency (EPA) guidance on cellulose measurement by establishing quantitative de-starching via nuclear magnetic resonance (EPA 2022). The selective removal of yeast beta-glucan was accomplished using a commercially available Zymolyase. Our results demonstrated excellent reproducibility, with coefficients of variance of 7.14% or less, when measuring cellulose in low cellulose content samples. The method was tested on relevant lab and plant samples, showing an average 0.9% ethanol derived from the conversion of cellulose when cellulase was added to the process and zero response when no cellulase was added. These findings indicate that a cellulose method using DMSO and pullulanase provides a complete and accurate view of cellulose content, composition, and conversion in industrial fermentation processes.

Sluiter, Justin [National Renewable Energy Laborat↗

Site 200 #1400 Block Area New Trailers Project, Soil Sampling and Analysis Plan/Quality Assurance Plan

Lawrence Livermore National Laboratory's (LLNL) Project Management Office (PMO) is proposing to install a series of modular trailers and install associated underground utilities in the 1400 Block at the Livermore Site. This Sampling and Analysis Plan (SAP) outlines the processes and procedures to collect environmental and geotechnical soil samples from the project area and to send the samples to the appropriate laboratory or laboratories for analysis or testing. The resulting environmental laboratory data will determine whether excavated soils can be reused on the project, or which type of landfill or landfills the soils may be sent for disposal. This SAP has been prepared and is organized to be consistent with LLNL's Soils Screening and Management Plan (SSMP) (LLNL, 2019), as well as the U.S. Environmental Protection Agency's (EPA) Data Quality Objectives programs (EPA, 2006).

54 ENVIRONMENTAL SCIENCES↗

NESHAPs CY19 Report: Radionuclide Air Emission Report for 2019

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) in which radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.1.17, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300. In 2019, LLNL maintained its compliance with 40 CFR 61, Subpart H. All radioactive air emissions resulted in calculated doses far below the annual 10 mrem (100 μSv) sitewide standard. The annual doses to the site-wide maximally exposed individual member of the public at the Livermore Site and Site 300 from planned and unplanned operations in 2019 are: Livermore Site: 4.3 x 10⁻³ mrem (4.3 x 10⁻² μSv); Site 300: 9.5 x 10⁻⁸ mrem (9.5 x 10⁻⁷ μSv).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Storm Water Pollution Prevention Plan Middle DP Road Recovery Effort, June 26, 2020

The United States Environmental Protection Agency (EPA) has issued a final 2017 Construction General Permit (CGP) that covers discharges of stormwater from construction sites. The 2017 National Pollutant Discharge Elimination System (NPDES) General Permit for Storm Water Discharges from Construction Activity (Appendix D) includes the following requirements:(1) conduct a critical habitat and threatened/endangered species study; (2) develop and implement a Storm Water Pollution Prevention Plan (SWPPP) in accordance with good engineering practices; (3) submit a Notice of Intent (NOI); (4) install and maintain erosion and stormwater controls; (5) perform and document storm water inspections during construction and site stabilization; (6) amend the SWPPP as necessary; and (7) submit a Notice of Termination (NOT) following project completion and final stabilization of disturbed areas. Authorization to discharge storm water is required under this Permit for both large and small construction projects disturbing more than one (1) acre or part of a larger common plan of development that collectively disturbs more than one (1) acre. All parties that meet the definition of Operator must be permitted. Each permittee is not required to develop and implement a separate SWPP Plan. It is required that there be at least one SWPP Plan for a site that incorporates the required elements for all Operators. The 2017 CGP number for New Mexico (Region 6) is NMR100000. This Plan, which has been developed for Triad National Security, LLC (Triad), describes the nature and sequencing of construction activities, potential sources of pollution, and identifies the Best Management Practices (BMPs) to minimize the potential for erosion and storm water pollution. The Plan was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. § §1251 et seq., as amended by the Water Quality Act of 1987, P.L. 100-4), and the regulations established by the U.S. Environmental Protection Agency (EPA) for National Pollutant Discharge Elimination System (NPDES) General Permits for Storm Water Discharges From Construction Activities.

54 ENVIRONMENTAL SCIENCES↗

Storm Water Pollution Prevention Plan Middle DP Road Recovery Effort, June 26, 2020 (Copy for Informational Puproses Only)

The United States Environmental Protection Agency (EPA) has issued a final 2017 Construction General Permit (CGP) that covers discharges of stormwater from construction sites. The 2017 National Pollutant Discharge Elimination System (NPDES) General Permit for Storm Water Discharges from Construction Activity (Appendix D) includes the following requirements: (1) conduct a critical habitat and threatened/endangered species study; (2) develop and implement a Storm Water Pollution Prevention Plan (SWPPP) in accordance with good engineering practices; (3) submit a Notice of Intent (NOI); (4) install and maintain erosion and stormwater controls; (5) perform and document storm water inspections during construction and site stabilization; (6) amend the SWPPP as necessary; and (7) submit a Notice of Termination (NOT) following project completion and final stabilization of disturbed areas. Authorization to discharge storm water is required under this Permit for both large and small construction projects disturbing more than one (1) acre or part of a larger common plan of development that collectively disturbs more than one (1) acre. All parties that meet the definition of Operator must be permitted. Each permittee is not required to develop and implement a separate SWPP Plan. It is required that there be at least one SWPP Plan for a site that incorporates the required elements for all Operators. The 2017 CGP number for New Mexico (Region 6) is NMR100000. This Plan, which has been developed for Triad National Security, LLC (Triad), describes the nature and sequencing of construction activities, potential sources of pollution, and identifies the Best Management Practices (BMPs) to minimize the potential for erosion and storm water pollution. The Plan was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. § §1251 et seq., as amended by the Water Quality Act of 1987, P.L. 100-4), and the regulations established by the U.S. Environmental Protection Agency (EPA) for National Pollutant Discharge Elimination System (NPDES) General Permits for Storm Water Discharges From Construction Activities.

54 ENVIRONMENTAL SCIENCES↗

Catalina Repower Feasibility Study: NREL Phases I & II Summary Report

Engineers at the National Renewable Energy Laboratory (NREL) supported Southern California Edison (SCE) and the United States Environmental Protection Agency (EPA) by conducting technical and economic analyses for energy systems at Santa Catalina (Catalina) Island, which is located 22 miles off the coast of Long Beach, California. This effort was part of a broader Repower Catalina Feasibility Study that was also supported by NV5, an engineering consulting firm and project partner to NREL for this analysis. This document describes NREL’s techno-economic modeling and optimization analysis for the first two phases of this project which focus on supply-side generation and energy storage options for Catalina. SCE’s goal for this analysis is to determine a strategy for electricity generation on Catalina Island that results in lower energy costs, improved energy resiliency, and reduced air emissions. EPA goals for this effort are to reduce emissions of air pollution and encourage renewable energy development on contaminated and formerly contaminated lands when such development is aligned with the community’s vision for the site. Currently, an on-island SCE power plant serves the Catalina Island electrical load with 6 reciprocating diesel generators totaling 9.4 MW; 23 propane-fueled microturbines totaling 1.5 MW; and a 1-MW, 7.2-MWh sodium sulfur battery energy storage system (BESS). In 2017, the electricity consumption on the island was 29.1 GWh, with an average load of 3.3 MW and peak load of approximately 5.5 MW. Considering new environmental standards on diesel generator emissions from California’s South Coast Air Quality Management District, a 60% renewable energy target for 2030 laid out in California’s Senate Bill 100, SCE’s Clean Power Electrification Pathway, and the characteristics of the island’s existing diesel generators, SCE is seeking to evaluate the technical and economic implications of different energy technology options to determine a path forward. Phases I and II of the Repower Catalina Feasibility Study, summarized in this document, evaluated the following: Interconnection with the mainland via an undersea cable; On-island fossil fuel generation, including diesel, propane, and/or liquified natural gas (LNG); On-island renewable energy (RE) technologies, including solar photovoltaics (PV), wind turbines, and wave energy devices; BESS to support the above generation technologies; Initial analysis of the potential impacts of implementing energy efficiency measures. Results indicate strong techno-economic potential for a mix of on-island diesel and/or propane generators, solar PV, BESS, and energy efficiency measures to help SCE and Catalina achieve their goals compliant with California’s emissions and clean energy standards while minimizing electricity life cycle costs (LCC) over the 30-year analysis period. This document summarizes the considerations and findings of Phases I and II, focusing on high-level takeaways from Phase I and more detailed results from Phase II, and discusses a potential path forward for Phase III.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2020 NEPA Polychlorinated Biphenyl (PCB) Risk Assessment

The Waste Isolation Pilot Plant (WIPP) facility is a U.S. Department of Energy (DOE) operating repository 654 m below the surface in a thick salt formation in southeastern New Mexico. The DOE disposes transuranic (TRU) waste produced from atomic energy defense activities at the WIPP facility. A portion of the waste shipped to the WIPP facility contains TRU radionuclides co-mingled with polychlorinated biphenyls (PCBs), which fall under U.S. Environmental Protection Agency (EPA) regulations implementing the Toxic Substances Control Act (TSCA). This report documents the risks of PCBs co-mingled with TRU waste (hereafter designated as PCB/TRU waste) designated for disposal at the WIPP facility. This analysis is input to the National Environmental Policy Act (NEPA) assessment by the DOE Carlsbad Field Office (CBFO) for the proposed increase of the WIPP facility disposal area to include additional waste panels (but not to increase the legislated WIPP volume). This analysis is not a compliance calculation to support a certification renewal nor does it support a planned change request (PCR) or planned change notice (PCN) to be submitted to the EPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Location of HENC 1 TA-63 TRU Waste Facility

This video will replace an onsite visit by the EPA. The EPA will not be able to come on site due to a COVID -19 related travel restriction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acceptable Knowledge Technologist Procedure

Process acceptable knowledge (AK) is a waste stream characterization method that can be used to meet all or part of the waste analysis requirements appropriate for the waste. The method may include documented knowledge of process (KOP), additional characterization data, and/or facility records of analysis. LANL will use process AK to ensure chemical compatibility; assign matrix parameter categories and Environmental Protection Agency (EPA) hazardous waste numbers (HWNs) commonly referred to as EPA codes to waste streams; and determine the waste material parameters and radionuclides present in waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗