Search NASASearch

SEARCH · Search NASA

Results for “Electric Power Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

928 records · Page 6

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This paper describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

electrified aircraft propulsion

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This presentation describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

electrified aircraft propulsion

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This paper describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

Electrified powertrain

How Distributed Energy Resources Can Support Resilience in Utility Distribution Networks

The goal of this webinar is to engage with electric utilities in the Midwest, particularly small public utilities, to understand the industry's needs for science tools to plan for winter resilience in the future, designing tools that will benefit electric power resilience in all communities. Michigan Tech leads this project with partners from multiple academic, government, and industry groups and asked NLR to present on DERs and laboratory tools and resources.

24 POWER TRANSMISSION AND DISTRIBUTION

Solar Array Automation Limitations

Significant progress in the automation of the spacecraft electrical power systems has been made within the past few years. This is especially important with the development of the space station and the increasing demand on the electrical power systems for future satellites. The key element of the spacecraft power system, the solar arrays which supply the power, will have to grow to supply many tens of kilowatts of power within the next twenty years. This growth will be accompanied by the problems associated with large distributed power systems. The growth of the arrays, the on-array management problems and potential solutions to array degradation or failure are discussed. Multilowatt arrays for unmanned spacecraft with comments on the implications of array degradation for manned spacecraft are discussed.

Terry M Trumble

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Physical Modeling and Design of a Nonvolatile Optically Gated High‐Power Diamond Transistor

In this work, we present the theory and modeling framework of a diamond optically gated junction field‐effect transistor (DOGFET). The device utilizes nitrogen substitutional centers in type‐1b diamond to optically modulate a p‐ boron doped diamond channel. Using sub‐gap lasers with intensities as low as 100 W/cm 2 , electrons are optically excited from substitutional nitrogen sites to the conduction band of the diamond substrate, thus enabling the optical gate to exercise control on modulating the space‐charge region at the junction and therefore the channel conductivity. We show that the device can deliver a current of 7 μA/μm, or equivalently 1750 A/cm 2 , while switching at a frequency greater than 100 kHz, in a form factor of 5 μm 2 . The breakdown voltage is found to be greater than 1850 V, with a breakdown field strength of ~13 MV/cm. Moreover, the device supports nonvolatile operation with a “memory effect” enabling single transistor state retention. The presented simulation framework provides a physically grounded insight into the limits and opportunities of optoelectronic diamond systems.

Engineering - Electronic and electrical engineerin

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)

Intrinsically Conductive {pi}‑d Conjugated Layers with Co–N4 Active Sites for Efficient Nitrate Electrocatalysis and Zinc-Nitrate Batteries

Electrochemical synthesis of ammonia from nitrate has been extensively investigated as a potential alternative to the energy-intensive Haber-Bosch process. This approach not only operates under ambient conditions but also simultaneously removes nitrate contaminants while producing ammonia as a value-added product. However, the ongoing quest lies in designing an efficient electrocatalyst that achieves a high ammonia yield rate, high selectivity, and long-term stability. Herein, we report the outstanding performance of a Co–N4 coordinated π-d layered Co3(HITP)2 (HITP = 2,3,6,7,10,11-hexaiminotriphenylene) in nitrate electrocatalysis. The unique combination of abundant Co–N4 active sites and superior electrical conductivity enables significant electrocatalytic activity, delivering a maximum ammonia yield rate of 56.8 mg cm–2 h–1 at −0.8 V vs RHE and a Faradaic efficiency of ∼91% at −0.4 V vs RHE. Mechanistic analysis reveals that alkaline conditions accelerate water dissociation to generate adsorbed hydrogen intermediates (H*), which are utilized by Co–N4 sites to drive the stepwise hydrogenation of nitrate to ammonia while suppressing competing hydrogen evolution reaction (HER) pathways. Furthermore, integration of this catalyst into a zinc-nitrate battery resulted in a maximum power density of 5.3 mW cm–2 and an open-circuit potential of ∼1.45 V. These results highlight the potential of π-d conjugated Co–N4 materials as an efficient catalyst for both environmental remediation and energy conversion.

Namvar, shahrirar

ELECTRIC PROPULSION- A NEW TECHNOLOGY

Within the past 3 years, electric thrust devices have passed from the first exploratory feasibility experiments to the flight-engineered hardware phase. This rapid surge of development has been punctuated by equally rapid improvements in the performance figures of electrical thrust devices. The most spectacular advances were made in ion engine technology. Total energy expenditure per ion pair has gone from 35,000 ev in 1958 to about 600 ev at the present time leading to power utilization efficiencies of up to 80 per cent, depending upon the specific impulse. The percentage of the particles intercepting the accelerating and focusing electrodes has been reduced from more than 50 per cent in 1958 to less than 0.01 per cent at the present time. Great improvements in ion current per unit area have also been realized, leading to greater thrust "pressures."

ELECTRIC PROPULSION

Manufacturing Process Development of a Carbon Fiber Reinforced Polymer Composite Shaft for Electric Motors

Electric aircraft applications require electric motors with increased specific power and efficiency. Composite structural components in motors are a potential solution for reducing motor mass, reducing magnetic losses, and limiting undesired conduction paths for fault, electromagnetic interference, or common-mode currents. In this report, manufacturing trials for a high-speed carbon fiber reinforced polymer composite motor shaft are presented. Four prototype shafts were produced using a hybrid biaxial/triaxial fabric that was circumferentially wrapped onto an additively manufactured high-temperature washout mandrel. An additional traditional overbraid approach was also evaluated and shows promise for high-rate, high-performance parts using automated manufacturing. This paper discusses the shaft design, manufacturing methods explored, material selection, the manufacturing trials, and the lessons learned. The results of this manufacturing investigation show feasibility for manufacturing composite shafts for electric motors.

Electric moto shaft

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

A Unified Scaling Framework for Comparative Analysis of Major Electrical Machine Topologies

This paper presents a unified framework for comparing major electrical machine topologies under identical output and thermal constraints, with emphasis on supply-chain-aware selection among rare-earth-intensive, reduced-rare-earth, and rare-earth-free solutions. Using power factor and air-gap flux density as the principal descriptors, the framework links topology choice to relative size, copper demand, magnet dependence, cost sensitivity, and inertia. To support robust early-stage screening, the deterministic scaling model is combined with uncertainty representation, Monte Carlo scenario propagation, and hesitationaware ranking. The results show that rare-earth-rich machines remain compact and dense, whereas reduced-rare-earth and rare-earth-free alternatives become more attractive under specific material-risk and cost scenarios.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)

Green Era Anaerobic Digester

Green Era Educational NFP constructed and commissioned the Green Era Renewable Energy & Urban Farming Campus in Chicago’s Auburn Gresham neighborhood. The project transformed a long-vacant brownfield site into a commercial-scale anaerobic digestion facility that converts food waste into renewable natural gas and nutrient-rich material for agricultural use. The facility can process up to 80,000 wet tons of food waste annually and supports approximately 15 permanent jobs while advancing food waste diversion, renewable energy production, nutrient recovery and community revitalization.

03 NATURAL GAS

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY

Helmholtz Motor: A Novel Electric Machine That Enables High Temperature Superconducting Armatures

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Cryogenic electric machines are a promising technology for multi megawatt electric aircraft drivetrains. Second generation high temperature superconductors (HTS) are the ideal conductor for the field winding (typically the rotor) of superconducting machines, and they have attractive features for the armature winding (typically the stator) of these machines. However, their use in armature windings has been severely limited due to excessive AC losses in conventional electric machines. This presentation will present the working principle, design, and a performance trade study of a novel electric machine – termed a Helmholtz machine – that enables HTS armatures by significantly reducing AC losses. The working principle of the patent pending Helmholtz motor is to optimize the rotor-produced magnetic field (i.e., the field winding) so that it produces a magnetic field almost purely in the plane of the HTS. This is accomplished using 2 rotors that contain a set of matched Helmholtz coil pairs (or matched permanent magnet Halbach arrays). The armature (stator) HTS coils are positioned between the rotors and oriented to minimize the out of plane magnetic field. The armature HTS coils are also designed to minimize the out of plane component of their self field. The presentation will include the lessons learned in the sizing and design of this motor, including equations for how to match the magnet arrays. A performance trade study will be presented for a partially superconducting, radial flux version of the motor. The trade study involved an optimization of a motor design code based on analytical calculations (electromagnetic, AC loss, thermofluid, mechanical, and motor sizing) that determine the motor’s total efficiency and total specific power. The design code will be described in the presentation, with an emphasis on the calculation of magnetic fields, AC loss, and temperature distribution.

Superconducting electric machines