Search NASA⌕ Search

SEARCH · Search NASA

Results for “FUELING STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities "Shore to Store" Project (Final Project Report)

The City of Los Angeles Harbor Department (Harbor Department, POLA) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota) and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme (POH), United Parcel Service (UPS), Total Transportation Services Inc. (TTSI), Southern Counties Express (SCE), Toyota Logistics Services (TLS), Air Liquide, National Renewable Energy Laboratory (NREL), Coalition For A Safe Environment, and the South Coast Air Quality Management District (South Coast AQMD) to introduce hydrogen (H 2 ) fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty H 2 fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The "Shore to Store" (S2S) project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota's fuel cell drive technology, were operated by UPS, TTSI, SCE, and TLS in revenue service. The demonstration fleet fueled at the S2S hydrogen fueling stations that were built in Ontario, California and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission (CEC) and South Coast AQMD and used as match funding for the S2S project. POH demonstrated two battery-electric yard tractors, and TLS demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating on zero-emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Electrochemical Hydrogen Compressor

U.S. automakers have invested significant resources in the research and development of hydrogen fuel cell electric vehicles (FCEVs). However, to enable the widespread deployment of FCEVs, an additional major investment is required to achieve an infrastructure for compressing hydrogen in hydrogen fueling stations. In order to dispense hydrogen to FCEV tanks quickly, the hydrogen must be compressed above a pressure of 875 bar (12,687 psi) at the fueling station. Mechanical compressors currently in use have high maintenance costs, poor reliability, and are noisy. To eliminate the need for mechanical compressors, Plug Power is extending its extensive experience in high-pressure proton-exchange-membrane (PEM), to develop an electrochemical hydrogen compressor (EHC) system for refueling applications that can deliver hydrogen at pressures greater than 875 bar. The work performed during this project was a collaboration between the Nation Renewable Energy Laboratory (NREL), Rensselaer Polytechnic Institute (RPI), and Gaia Energy Research Institute LLC (GAIA).

08 HYDROGEN↗

Diffusion Bonded Hydrogen Pre-Cooler Pressure Testing

Diffusion bonded heat exchangers, also known as printed circuit heat exchangers (PCHEs), have numerous benefits over traditional shell and tube heat exchangers including high pressure containment, a compact size with 1000 to 5000 m 2 of surface area per unit volume, and lower costs. One emerging application is in hydrogen vehicle fueling stations as a hydrogen pre-cooler (H2PC™) where the hydrogen is cooled at pressures up to 900 bar. These pre-coolers must be able to withstand pressure cycling over 10 5 cycles during the fueling station lifetime without degradation of their pressure vessel integrity that could result in hydrogen leakage.

08 HYDROGEN↗

Preliminary Assessment of Spatial Competition in the Market for E85: Presentation Supplement

The Preliminary Assessment of Spatial Competition in the Market for E85 presentation and supplementary report from the U.S. Department of Energy’s National Renewable Energy Laboratory examine how the spacing of E85 fueling stations impacts E85 retail pricing. The analysis finds an inverse correlation between station density and E85 prices, with local competition putting downward pressure on E85 prices. A gas station with E85 whose nearest competitor is within a 0.5 mile radius is associated with a lower E85 price per gallon than an otherwise identical station with E85 whose nearest competitor is farther away. The analysis also finds a higher level of correlation between E85 and both E10 and wholesale gasoline prices than with ethanol costs. This indicates that E85 may, in fact, be priced with respect to its substitute fuel, and not based on the cost of its inputs. These findings help identify key trends and barriers in E85 markets and highlight data gaps that, if addressed, could help enable competitive E85 markets. The analysis was released in February 2017 and uses national and Minnesota-specific price data.

09 BIOMASS FUELS↗

Results from an analytical investigation of small-scale releases from liquid hydrogen storage systems.

A need exists for developing codes and standards to support the wide-spread delivery of liquid hydrogen bulk fuel and fueling station storage. To develop these codes and standards the consequences of planned and unplanned hydrogen releases must be understood. The systems under consideration are mainly those used in supplying hydrogen for transportation. These systems include production storage tanks, tanker trucks and tanks located at vehicle fueling stations. Typically these systems store hydrogen in the saturated state at approximately 11 atmospheres. Storage vessels are heavily insulated and sometimes actively cooled to minimize the rate of hydrogen boil-off (intended hydrogen release).

08 HYDROGEN↗

Report on General Hydrogen Safety

Hydrogen is an important resource for many different industries throughout the world, including refining, manufacturing, and as a direct energy source. Hydrogen production, through methods such as steam methane reforming, has been developed over several decades. There is a large global demand for hydrogen from these industries and safe production and distribution are paramount for hydrogen systems. Codes and standards have been developed to reduce the risk associated with hydrogen accidents to the public. These codes and standards are similar to those in other industries in which there is inherent risk to the public, such as gasoline and natural gas production and distribution. Although there will always be a risk to the public in these types of fuels, the codes and standards are developed to reduce the likelihood of an accident occurring and reduce the severity of impact, should one occur. This report reviews the current state of hydrogen in the United States and outlines the codes and standards that ensure safe operation of hydrogen systems. The total hydrogen demand and use in different industries is identified. Additionally, the current landscape of hydrogen production and fueling stations in the United States is outlined. The safety of hydrogen systems is discussed through an overview of the purpose, methods, and content included in codes and standards. As outlined in this safety overview, the risk to the public in operation of hydrogen generation facilities and fueling stations is reduced through implementation of appropriate measures. Codes, such as NFPA 2, ensure that the risk associated with a hydrogen system is no greater than the risk presented by gasoline refueling stations.

08 HYDROGEN↗

Data requirements for improving the Quantitative Risk Assessment of liquid hydrogen storage systems

Quantitative Risk Assessment (QRA) supports the development of risk-informed safety codes and standards which are employed to enable the safe deployment of hydrogen technologies essential to decarbonize the transportation sector. System reliability data is a necessary input for rigorous QRA. Here, the lack of reliability data for bulk liquid hydrogen (LH 2 ) storage systems located on site at fueling stations limits the use of QRAs. In turn, this hinders the ability to develop the necessary safety codes and standards that enable worldwide deployment of these stations. Through a QRA-based analysis of a LH 2 storage system, this work focuses on identifying relevant scenario and probability data currently available and ascertaining future data collection requirements regarding risks specific to liquid hydrogen releases. The work developed consists of the analysis of a general bulk LH 2 storage system design located at a hydrogen fueling station. Failure Mode and Effect Analysis (FMEA) and traditional QRA modeling tools such as Event Sequence Diagrams (ESD) and Fault Tree Analysis (FTA) are employed to identify, rank, and model risk scenarios related to the release of LH 2 . Based on this analysis, scenario and reliability data needs to add LH 2 -related components to QRA are identified with the purpose of improving the future safety and risk assessment of these systems.

08 HYDROGEN↗

Development of dispensing hardware for safe fueling of heavy duty vehicles

The development of safe dispensing equipment for the fueling of heavy duty (HD) vehicles is critical to the expansion of this newly and quickly expanding market. This paper discusses the development of a HD dispenser and nozzles assembly (nozzle, hose, breakaway) for these new, larger vehicles where flow rates are more than double compared to light duty (LD) vehicles. This equipment must operate at nominal pressures of 700 bar, -40o C gas temperature, and average flow rate of 5-10 kg/min at a high throughput commercial hydrogen fueling station without leaking hydrogen. The project surveyed HD vehicle manufacturers, station developers, and component suppliers to determine the basic specifications of the dispensing equipment and nozzle assembly. The team also examined existing codes and standards to determine necessary changes to accommodate HD components. From this information, the team developed a set of specifications which will be used to design the dispensing equipment. In order to meet these goals, the team performed computational fluid dynamic, pressure modelling, and temperature analysis in order to determine the necessary parameters to meet existing safety standards modified for HD fueling. The team also considered user, operational, and maintenance requirements, such as freeze lock which has been an issue which prevents the removal of the nozzle from LD vehicles. The team also performed a failure mode and effects analysis (FMEA) to identify the possible failures in the design. The dispenser and nozzle assembly will be tested separately, and then installed on an innovative, HD fueling station which will use a HD vehicle simulator to test the entire system.

08 HYDROGEN↗

Mixing and warming of cryogenic hydrogen releases

Laboratory measurements were made on the concentration and temperature fields of cryogenic hydrogen jets. Images of spontaneous Raman scattering from a pulsed planar laser sheet were used to measure the concentration and temperature fields from varied releases. Jets with up to 5 bar pressure, with near-liquid temperatures at the release point, were characterized in this work. This data is relevant for characterizing unintended leaks from piping connected to cryogenic hydrogen storage tanks, such as might be encountered at a hydrogen fuel cell vehicle fueling station. The average centerline mass fraction was observed to decay at a rate similar to room temperature hydrogen jets, while the half-width of the Gaussian profiles of mass fraction were observed to spread more slowly than for room temperature hydrogen. This suggests that the mixing and models for cryogenic hydrogen may be different than for room temperature hydrogen. Results from this work were also compared to a one-dimensional (streamwise) model. Good agreement was seen in terms of temperature and mass fraction. Furthermore, a validated version of this model will be exercised to quantitatively assess the risk at hydrogen fueling stations with cryogenic hydrogen on-site.

08 HYDROGEN↗

Characteristic of cryogenic hydrogen flames from high-aspect ratio nozzles

Unintentional leaks at hydrogen fueling stations have the potential to form hydrogen jet flames, which pose a risk to people and infrastructure. The heat flux from these jet flames are often used to develop separation distances between hydrogen components and buildings, lot-lines, etc. The heat flux and visible flame length is well understood for releases from round nozzles, but real unintended leaks would be expected to be from higher aspect-ratio cracks. Here, we measured the visible flame length and heat-flux characteristics of cryogenic hydrogen flames from high-aspect ratio nozzles. Heat flux measurements from 5 radiometers were used to assess the single-point vs the multi-point methods for interpretation of heat flux sensor data, finding the axial distance of the sensor for a single-point heat flux measurement to be important. We compare the flame length and heat flux data to flames of both cryogenic and compressed hydrogen from round nozzles. The aspect ratio of the release does not affect the flame length or heat flux significantly, for a given mass flow under the range of conditions studied. The engineering correlations presented in this work enable the prediction of flame length and heat flux which can be used to assess risk at hydrogen fueling stations with liquid hydrogen and develop science-based separation distances for these stations.

08 HYDROGEN↗

WVU Hydrogen Fuel Dispensing Station

The scope of this project was changed during the course of the project. Phase I of the project was to construct a site similar to the site at Central West Virginia Regional Airport in Charleston, WV to show that duplication of the site was a feasible method of conducting hydrogen stations. Phase II of the project was necessitated due to a lack of funding that was planned for the development of the station in Morgantown. The US Department of Energy determined that the station in Charleston would be dismantled and moved to Morgantown and reassembled at the Morgantown site. This necessitated storage of the components of the station for almost a year at the NAFTC Headquarters which caused a number of issues with the equipment that will be discussed in later portions of this report. This report will consist of PHASE I and PHASE II with discussions on each of the tasks scheduled for each phase of the project.

08 HYDROGEN↗

Regenerative fuel cell systems for space station

Regenerative fuel cell (RFC) systems are the leading energy storage candidates for Space Station. Key design features are the advanced state of technology readiness and high degree of system level design flexibility. Technology readiness was demonstrated through testing at the single cell, cell stack, mechanical ancillary component, subsystem, and breadboard levels. Design flexibility characteristics include independent sizing of power and energy storage portions of the system, integration of common reactants with other space station systems, and a wide range of various maintenance approaches. The design features led to selection of a RFC system as the sole electrochemical energy storage technology option for the space station advanced development program.

Hoberecht, M. A.↗

Retail Hydrogen Station Reliability Status and Advances

One of the most vital emerging commercial markets for hydrogen is fuel cell-powered mobility including cars, trucks, and buses. These vehicles are refueled via a network of hydrogen fueling stations, with the highest number of U.S. stations being in California. The numbers of both fuel cell electric vehicles (FCEVs) and hydrogen stations have increased in the last two years, with anecdotal information from FCEV drivers indicating that station reliability is hurting the consumer acceptability of FCEV technologies. Therefore, this study benchmarks the current state of hydrogen station reliability in practice and presents on-going research that is investigating the failures that are contribute to hydrogen station reliability issues. This is accomplished with an analysis of operation, safety, and maintenance data from hydrogen stations and fuel cell electric vehicles to benchmark the maintenance and failure of hydrogen stations and their components. This analysis, of over 5,000 station maintenance events, presents the leading maintenance categories and failure rates, and is a prerequisite to the development of data-driven reliability improvement plans. We present a reliability growth analysis and on-going research into the root causes of failure for dispensers, a particularly failure-prone subsystem.

08 HYDROGEN↗

E85 Fueling Infrastructure Trends: A Decade in Review

This report provides information on ethanol fueling infrastructure and industry trends over the last 10 years. It is informed primarily by ethanol fueling station location data collected through the U.S. Department of Energy's Alternative Fuels Data Center (AFDC) Station Locator from 2011 through 2021 (AFDC 2021a). Industry stakeholders, including the Renewable Fuels Association and Growth Energy, also provided data and additional context around trends seen in the data.

33 ADVANCED PROPULSION SYSTEMS↗

PERMITTING OF A PROJECT INVOLVING HYDROGEN: A CODE OFFICIAL’S PERSPECTIVE

Recent growth in the development of hydrogen infrastructure has led to more requests for code officials to approve hydrogen-related projects and facilities. To help expedite the review and approval process, significant efforts have been made to educate code officials on permitting hydrogen vehicle fueling stations and facilities using stationary fuel cells (e.g., backup power for telephone cell tower sites). Despite these efforts, project delays continue because of several factors, including the limited experience of code officials with these types of facilities, submittals that lack the required information (including failure to adequately address local requirements), and submission of poor quality documents. The purpose of this paper is to help project proponents overcome these potential roadblocks and obtain timely approval for a project. A case study of an actual stationary application permitting request is provided to illustrate the value of addressing these issues.

Kallman, Richard A.↗

Toyota Highlander FCHV (CRADA CRD-12-00469 Final Report)

This project relates to the loan of four Toyota Mirai FCEV-adv vehicles to NLR to provide a load (vehicles to fill with hydrogen) to our fueling station research facility to study hydrogen fueling infrastructure performance using 700 bar precooled hydrogen at ESIF’s Hydrogen Infrastructure Testing and Research Facility (HITRF) facility.

33 ADVANCED PROPULSION SYSTEMS↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗